Aims. Joint registries classify all further arthroplasty procedures to a knee with an existing
Aim. Our collaborative study aims to demonstrate that acute
Combined Partial Knee Arthroplasty (CPKA) is a promising alternative to Total Knee Arthroplasty (TKA) for the treatment of multi-compartment arthrosis. Through the simultaneous or staged implantation of multiple
Aims. There is ambiguity surrounding the degree of scaphoid union required to safely allow mobilization following scaphoid waist fracture. Premature mobilization could lead to refracture, but late mobilization may cause stiffness and delay return to normal function. This study aims to explore the risk of refracture at different stages of scaphoid waist fracture union in three common fracture patterns, using a novel finite element method. Methods. The most common anatomical variant of the scaphoid was modelled from a CT scan of a healthy hand and wrist using 3D Slicer freeware. This model was uploaded into COMSOL Multiphysics software to enable the application of physiological enhancements. Three common waist fracture patterns were produced following the Russe classification. Each fracture had differing stages of healing, ranging from 10% to 90%
A larger radial tuberosity, and therefore a smaller radioulnar space, may cause mechanical impingement of the DBT predisposing to tear. We sought to investigate anatomic factors associated with
Chronic Achilles tendinopathy is characterised by sub-acute inflammation with pro-inflammatory type 1 macrophages (M1), tissue degeneration and consequent
The primary aim of this study was to compare the knee specific functional outcome of
Aims. In elderly patients with osteoarthritis and protrusio who require arthroplasty, dislocation of the hip is difficult due to migration of the femoral head. Traditionally, neck osteotomy is performed in situ, so this is not always achieved. Therefore, the purpose of this study is to describe a
There has been a significant increase in the demand for arthroplasty as a result of the Covid 19 pandemic and lack of beds on the green pathway. The average length of in-hospital stay following knee replacements has been successfully reduced over the years following introduction and adoption of enhanced recovery protocols. Day case arthroplasty has the potential to be efficient as well as cost-effective. We present our day case pathway for elective knee arthroplasty and early results of its adoption at a district general hospital. Our pathway was developed through a multidisciplinary input from surgeons, anaesthetists, physiotherapists, nursing staff, administrative staff, surgical care practitioners and pharmacists. Inclusion criteria were defined to identify patients suitable for cay case arthroplasty. Results of 32 patients who underwent day case
Abstract. In aged trauma patients the basic prerequisite is early mobilization and full weight-bearing, as immobilization can trigger various complications such as pressure ulcers, pneumonia, urinary tract infections and others. Mortality of elderly patients increases significantly in fracture patients with
Aims. Custom-made
Aims. While medial unicompartmental knee arthroplasty (UKA) is indicated
for patients with full-thickness cartilage loss, it is occasionally
used to treat those with partial-thickness loss. The aim of this
study was to investigate the five-year outcomes in a consecutive
series of UKAs used in patients with
Rotator cuff disease encompasses a spectrum from
Pre-operative 3D glenoid planning improves component placement in terms of version, inclination, offset and orientation. Version and inclination measurements require the position of the inferior angle. As a consequence, current planning tools require a 3D model of the full scapula to accurately determine the glenoid parameters. Statistical shape models (SSMs) can be used to reconstruct the missing anatomy of bones. Therefore, the objective of this study is to develop and validate an SSM for the reconstruction of the inferior scapula, hereby reducing the irradiation exposure for patients. The training dataset for the statistical shape consisted of 110 CT images from patients without observable scapulae pathologies as judged by an experienced shoulder surgeon. 3D scapulae models were constructed from the segmented images. An open-source non-rigid B-spline-based registration algorithm was used to obtain point-to-point correspondences between the models. A statistical shape model was then constructed from the dataset using principal component analysis. Leave-one-out cross-validation was performed to evaluate the accuracy of the predicted glenoid parameters from virtual
Abstract. Aim. Excessive glenoid retroversion and posterior wear leads to technical challenges when performing anatomic shoulder replacement. Various techniques have been described to correct glenoid version, including eccentric reaming, bone graft, posterior augmentation and custom prosthesis. Clinical outcomes and survivorship of a Stemless humeral component with cemented pegged polyethylene glenoid with eccentric reaming to partially correct retroversion are presented. Patients and Methods. Between 2010– 2019, 115 Mathys Affinis Stemless Shoulder Replacements were performed. 50 patients with significant posterior wear and retroversion (Walch type B1, B2, B3 and C) were identified. Measurement of Pre-operative glenoid retroversion and Glenoid component version on a post op axillary view was performed by method as described by Matsen FA. Relative correction was correlated with clinical and radiological outcome. Results. 4 were lost to follow up. 46 patients were therefore reviewed. The mean follow up was 4 years (2–8.9 years). Walch B1, Pre op Retroversion: 12 (8–20), post op retroversion :11.8 (−4 to 19), correction= 0.2. Walch B2, Pre op Retroversion :18.4 (10–32), post op retroversion: 13.2 (1 −22), correction= 5.2. Walch B3, Pre op Retroversion: 19.1 (13–32)post op retroversion : 16.1 (9–25), correction= 3.0. Walch C, Pre op Retroversion: 33.3 (28–42) post op retroversion: 16.0 (6–27), correction= 17.3. 3 patients required revision surgery for rotator cuff failure. Conclusion.
Aim. Chronic osteomyelitis of the calcaneus is a frequent problem in a population of diabetic patients, patients with neurologic disorders or bedridden patients with ulcers.
Radial head fractures are relatively common, representing approximately one-third of all elbow fractures. Outcomes are generally inversely proportional to the amount of force involved in the mechanism of injury, with simple fractures doing better than more comminuted ones. However, the prognosis for these fractures may also be influenced by associated injuries and patient-related factors (age, body index mass, gender, tobacco habit, etc.) The purpose of this study is to evaluate which factors will affect range of motion and function in
We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a
Osteosynthesis of high-energy metaphyseal proximal tibia fractures is still challenging, especially in patients with severe soft tissue injuries and/or short stature. Although the use of external fixators is the traditional treatment of choice for open comminuted fractures, patients' acceptance is low due to the high profile and therefore the physical burden of the devices. Recently, clinical case reports have shown that supercutaneous locked plating used as definite external fixation could be an efficient alternative. Therefore, the aim of this study was to evaluate the effect of implant configuration on stability and interfragmentary motions of unstable proximal tibia fractures fixed by means of externalized locked plating. Based on a right tibia CT scan of a 48 years-old male donor, a finite element model of an unstable proximal tibia fracture was developed to compare the stability of one internal and two different externalized plate fixations. A 2-cm osteotomy gap, located 5 cm distally to the articular surface and replicating an AO/OTA 41-C2.2 fracture, was virtually fixed with a medial stainless steel LISS-DF plate. Three implant configurations (IC) with different plate elevations were modelled and virtually tested biomechanically: IC-1 with 2-mm elevation (internal locked plate fixation), IC-2 with 22-mm elevation (externalized locked plate fixation with thin soft tissue simulation) and IC-3 with 32-mm elevation (externalized locked plate fixation with thick soft tissue simulation). Axial loads of 25 kg (partial weightbearing) and 80 kg (full weightbearing) were applied to the proximal tibia end and distributed at a ratio of 80%/20% on the medial/lateral condyles. A hinge joint was simulated at the distal end of the tibia. Parameters of interest were construct stiffness, as well as interfragmentary motion and longitudinal strain at the most lateral aspect of the fracture. Construct stiffness was 655 N/mm (IC-1), 197 N/mm (IC-2) and 128 N/mm (IC-3). Interfragmentary motions under