The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a locking compression plate.
In the augmented group additionally 1 ml of bone cement was injected
into the screw hole before insertion of the screw. Biomechanical
testing was performed in axial sinusoidal loading. Augmentation significantly
reduced the cut-out distance in the osteoporotic models by about
67% (non-augmented mean 0.30 mm ( Cite this article:
Objectives. The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics. Methods. Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired student t-test (two tailed; p < 0.05 was considered significant). Results. Average
Introduction. Pedicle screw pullout or loosening is increased in the osteoporotic spine. Recent studies showed a significant increase of pullout forces especially for PMMA-augmentation. With application of conventional viscosity
Systemic antibiotics reduce infection in open
fractures. Local delivery of antibiotics can provide higher doses
to wounds without toxic systemic effects. This study investigated
the effect on infection of combining systemic with local antibiotics
via polymethylmethacrylate (PMMA) beads or gel delivery. An established Staphylococcus aureus contaminated
fracture model in rats was used. Wounds were debrided and irrigated
six hours after contamination and animals assigned to one of three
groups, all of which received systemic antibiotics. One group had
local delivery via antibiotic gel, another
Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections. Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).Aims
Methods
Background. Giant cell tumours of bone (GCT) are benign bone tumours with a locally aggressive character. Local recurrence is considered the main complication of surgical treatment and is described in up to 50% of patients. Intralesional curettage with the use of adjuvants like phenol or polymethylmetacrylate (PMMA) is recommended as initial treatment, significantly decreasing the risk of recurrence. However, risk factors for local recurrence in skeletal GCT have not yet been firmly established and a golden standard for local therapy remains controversial. Objective. The identification of risk factors predisposing for an increased risk of local recurrence. In addition, different surgical techniques are compared to identify the optimal surgical approach for the identified risk factors. Methods. In a retrospective study all 215 patients with bone GCT treated between 1964 and 2009 in one centre were included, of which 193 were suitable for analysis. All patients had minimal follow-up of 12 months (mean 115; range 12–445). Using a Kaplan Meier survival analysis recurrence free survival rates were calculated. Cox-regression was used to determine the influence of different types of therapy, the use of adjuvants, and various patient and tumour characteristics. Results. The mean local recurrence rate for all patients was 35.2% (n=68, 95%CI: 28.3–42.1). Recurrence rate after wide resection was 0.17 (n=6, 95%CI: 0.04–0.29), after curettage with adjuvants 0.32 (n=42, 95%CI 0.24–0.41) and after curettage alone 0.74 (n=20, 95%CI: 0.57–0.91, p < 0.001). Soft tissue extension (Hazard Ratio: 3.8, p < 0.001), localisation in radius and ulna (HR: 2.6, p=0.013), and surgical experience (HR: 2.2, p=0.022) were identified as significant general risk factors for local recurrence. For intralesional resection, Campanacci grade III (HR: 3.9, p=0.019) and location in axial skeleton (HR: 3.3, p=0.016) additionally significantly increased this risk. Comparing treatments our data showed that curettage followed by adjuvants was superior to curettage alone (p < 0.004), and the application of both phenol and
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes. A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.Aims
Methods
Introduction. Despite the routine use of irrigation, debridement and systemic antibiotics, there is a high incidence of infection in severe open fractures. The synergistic use of local and systemic antibiotics appreciably reduces infection rates although the time window within which this is effective is unknown. The aim was to determine if delaying treatment of wounds causes higher levels of infection. Methods. A defect was created in the femurs of 90 Sprague-Dawley rats and inoculated with 105CFUs Staphylococcus aureus. At 2, 6 and 24 hours following contamination, the defect was irrigated and debrided. The experimental groups had either vancomycin or tobramycin impregnated
BACKGROUND. Osteoporosis with subsequent osteoporotic vertebral compression fractures is an increasingly important disease due not only to its significant economic impact but also to the increasing age of our population. Pain reduction and stabilization are of primary importance with osteoporotic vertebral compression fractures. OBJECTIVE. To compare the efficacy and safety of balloon kyphoplasty and vertebroplasty for the treatment of vertebral compression fractures. MATERIALS & METHODS. From January 2004 to December 2009, 142 patients (32 males and 110 females), from 54 to 84 years old (mean age 67.4) were treated for 185 osteoporotic vertebral fractures of the thoracic or lumbar spine (level of fracture at Th5 or lower), with back pain for more than 8 weeks, and a visual analogue scale (VAS) score of 5 or more. Twenty-two patients (29 fractures) were lost at follow-up period and excluded. Patients were randomly allocated to percutaneous kyphoplasty (64%) or vertebroplasty (36%). All fractures were analyzed for improvement in sagittal alignment (Cobb angle, kyphotic angle, sagittal index, vertebral height). The patients were evaluated using the visual analog scale (VAS) and the Oswestry Disability Score. Radiographs were performed postoperatively, and at 1, 3, 6, and 12 months. RESULTS. The score according to pain, the patient's ability to ambulate independently and without difficulty, and the need for medications improved significantly (P < 0.001) after kyphoplasty or vertebroplasty. No significant difference could be found between both groups for the mean VAS and ODI preoperative and postoperative. Vertebral body height and kyphotic wedge angle of the T-L spine were also improved (p < 0.001); although kyphosis correction seems to be improved better in kyphoplasty than vertebroplasty. The rate of leakage was 12% for kyphoplasty and 32% for vertebroplasty; nevertheless most of the leakage was clinically asymptomatic and the rate of serious problems remained low (pulmonary embolism 0.01% kyphoplasty vs 0.6% vertebroplasty). New fractures in the next 6 months at the adjacent vertebrae were observed ∼ 15% in both groups. More
The purpose of this study was to: review the efficacy of the induced membrane technique (IMT), also known as the Masquelet technique; and investigate the relationship between patient factors and technique variations on the outcomes of the IMT. A systematic search was performed in CINAHL, The Cochrane Library, Embase, Ovid MEDLINE, and PubMed. We included articles from 1 January 1980 to 30 September 2019. Studies with a minimum sample size of five cases, where the IMT was performed primarily in adult patients (≥ 18 years old), in a long bone were included. Multivariate regression models were performed on patient-level data to determine variables associated with nonunion, postoperative infection, and the need for additional procedures.Aims
Methods
Deep bone and joint infections (DBJI) are directly intertwined with health, demographic change towards an elderly population, and wellbeing. The elderly human population is more prone to acquire infections, and the consequences such as pain, reduced quality of life, morbidity, absence from work and premature retirement due to disability place significant burdens on already strained healthcare systems and societal budgets. DBJIs are less responsive to systemic antibiotics because of poor vascular perfusion in necrotic bone, large bone defects and persistent biofilm-based infection. Emerging bacterial resistance poses a major threat and new innovative treatment modalities are urgently needed to curb its current trajectory. We present a new biphasic ceramic bone substitute consisting of hydroxyapatite and calcium sulphate for local antibiotic delivery in combination with bone regeneration. Gentamicin release was measured in four setups: 1) Objectives
Materials and Methods
Demineralised bone matrix (DBM) is rarely used for the local
delivery of prophylactic antibiotics. Our aim, in this study, was
to show that a graft with a bioactive glass and DBM combination,
which is currently available for clinical use, can be loaded with
tobramycin and release levels of antibiotic greater than the minimum
inhibitory concentration for Antibiotic was loaded into a graft and subsequently evaluated
for drug elution kinetics and the inhibition of bacterial growth.
A rat femoral condylar plug model was used to determine the effect
of the graft, loaded with antibiotic, on bone healing.Aims
Materials and Methods
The aim of this study was to investigate the effect of a posterior
malleolar fragment (PMF), with <
25% ankle joint surface, on
pressure distribution and joint-stability. There is still little
scientific evidence available to advise on the size of PMF, which
is essential to provide treatment. To date, studies show inconsistent
results and recommendations for surgical treatment date from 1940. A total of 12 cadaveric ankles were assigned to two study groups.
A trimalleolar fracture was created, followed by open reduction
and internal fixation. PMF was fixed in Group I, but not in Group
II. Intra-articular pressure was measured and cyclic loading was
performed.Aims
Materials and Methods
This study describes the use of the Masquelet technique to treat
segmental tibial bone loss in 12 patients. This retrospective case series reviewed 12 patients treated between
2010 and 2015 to determine their clinical outcome. Patients were
mostly male with a mean age of 36 years (16 to 62). The outcomes
recorded included union, infection and amputation. The mean follow-up
was 675 days (403 to 952). Aims
Patients and Methods
The purpose of this study was to refine an accepted contaminated
rat femur defect model to result in an infection rate of approximately
50%. This threshold will allow examination of treatments aimed at
reducing infection in open fractures with less risk of type II error. Defects were created in the stablised femurs of anaethetised
rats, contaminated with Objectives
Methods
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
Using human cadaver specimens, we investigated
the role of supplementary fibular plating in the treatment of distal
tibial fractures using an intramedullary nail. Fibular plating is
thought to improve stability in these situations, but has been reported
to have increased soft-tissue complications and to impair union
of the fracture. We proposed that multidirectional locking screws
provide adequate stability, making additional fibular plating unnecessary.
A distal tibiofibular osteotomy model performed on matched fresh-frozen
lower limb specimens was stabilised with reamed nails using conventional
biplanar distal locking (CDL) or multidirectional distal locking
(MDL) options with and without fibular plating. Rotational stiffness
was assessed under a constant axial force of 150 N and a superimposed
torque of ± 5 Nm. Total movement, and neutral zone and fracture
gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial
fracture site, albeit to a small degree (p = 0.013). In the MDL
group additional fibular plating did not increase the stiffness.
The MDL nail without fibular plating was significantly more stable
than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not
improve stability if a multidirectional distal locking intramedullary
nail is used, and is therefore unnecessary if not needed to aid
reduction. Cite this article: