Advertisement for orthosearch.org.uk
Results 1 - 20 of 67
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 79 - 79
23 Jun 2023
Paprosky W Gerlinger T
Full Access

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability following these surgeries. Most reports have studied constructs using ≤28mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange. We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32mm (23%), 36mm (62%), or 40mm (15%) diameter heads. Crosslinked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow up was 3.5 (1.0–9.1) years. Statistical analyses were performed with significance set at p<0.05. Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. Following revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes. Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical or implant factors that reduced the risk of instability or other complication


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 10 - 10
1 Apr 2022
Fontalis A Hansjee S Vanhegan I Ahmad SA Ogilvie A Giebaly D Kayani B Haddad FS
Full Access

Cementless stem designs in total hip arthroplasty differ in relation to geometry and area of fixation. We utilised radiostereometric analysis (RSA) to evaluate the 2-year migration of a novel, short, proximally coated femoral stem. 30 participants undergoing primary total hip replacement for any cause (rheumatoid or inflammatory arthritis, osteoarthritis) were prospectively recruited in this study. Osteoporotic patients and cases of suspected infection were excluded. All patients received a short blade stem, proximally coated with a reduced lateral shoulder and narrow triple taper geometry to minimise bone removal. RSA radiographs were performed post-operatively and at 6 weeks, 6 months, 1- and 2 years. The Harris Hip Score (HHS), Oxford Hip Score (OHS) and EQ-5D were collected at baseline and at 2 years post-operatively. The stability of implants and complications were captured during each follow-up visit. A total of 14 female and 16 male patients were recruited with a mean age of 64.8 (range 47 to 75). At two years the mean subsidence of the stem was 0.34 mm (SD 0.62) and the total migration 0.74 mm (SD 0.60). The mean medial translation at two years was 0.059 (0.24) and the mean anterior translation 0.12 (0.59) respectively. Baseline PROM scores improved significantly at 2-years from pre-operatively (median and interquartile range): HHS from 33 (18.25) to 92 (19), EQ5D from 0.5 (0.35) to 0.94 (0.17), OHS from 21 (18.25) to 42 (4.25). P-value for all comparisons was <0.001. 2-year follow up data revealed no complications. There were no stem revisions in study participants and no heterotopic ossifications were identified on radiographs. 2-year migration results of a cementless, short blade, proximally coated tapered femoral stem using RSA, showed the stem exhibits a predictable migration pattern and achieves initial stability. This is highly likely to translate to mid and long-term stability, which needs to be corroborated by long-term outcome studies. Furthermore, participants demonstrated excellent clinical, patient reported and radiological outcomes after 2 years of follow up to support expansion in the use of this prosthesis


Bone & Joint Open
Vol. 4, Issue 12 | Pages 964 - 969
19 Dec 2023
Berwin JT Duffy SDX Gargan MF Barnes JR

Aims

We assessed the long-term outcomes of a large cohort of patients who have undergone a periacetabular osteotomy (PAO), and sought to validate a patient satisfaction questionnaire for use in a PAO cohort.

Methods

All patients who had undergone a PAO from July 1998 to February 2013 were surveyed, with several patient-reported outcome measures (PROMs) and radiological measurements of preoperative acetabular dysplasia and postoperative correction also recorded. Patients were asked to rate their level of satisfaction with their operation in achieving pain relief, restoration of activities of daily living, ability to perform recreational activity, and their overall level of satisfaction with the procedure.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 644 - 649
1 Apr 2021
Alsousou J Oragu E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S

Aims. The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA). Methods. A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported. Results. At two years, the mean subsidence of the head and tip for the TriFit stem was 0.38 mm (SD 0.32) and 0.52 mm (SD 0.36), respectively. The total migration of the head and tip was 0.55 mm (SD 0.32) and 0.71 mm (SD 0.38), respectively. There were no statistically significant differences between the three to 12 months' migration (p = 0.105) and 12 to 24 months' migration (p = 0.694). The OHS and EQ-5D showed significant improvements at two years. Conclusion. The results of this study suggest that the TriFit femoral stem achieves initial stability and is likely to be stable in the mid and long term. A long-term outcome study is required to assess late mechanisms of failure and the effects of bone mineral density (BMD) related changes. Cite this article: Bone Joint J 2021;103-B(4):644–649


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1304 - 1312
1 Dec 2022
Kim HKW Almakias R Millis MB Vakulenko-Lagun B

Aims

Perthes’ disease (PD) is a childhood hip disorder that can affect the quality of life in adulthood due to femoral head deformity and osteoarthritis. There is very little data on how PD patients function as adults, especially from the patients’ perspective. The purpose of this study was to collect treatment history, demographic details, the University of California, Los Angeles activity score (UCLA), the 36-Item Short Form survey (SF-36) score, and the Hip disability and Osteoarthritis Outcome score (HOOS) of adults who had PD using a web-based survey method and to compare their outcomes to the outcomes from an age- and sex-matched normative population.

Methods

The English REDCap-based survey was made available on a PD study group website. The survey included childhood and adult PD history, UCLA, SF-36, and HOOS. Of the 1,182 participants who completed the survey, the 921 participants who did not have a total hip arthroplasty are the focus of this study. The mean age at survey was 38 years (SD 12) and the mean duration from age at PD onset to survey participation was 30.8 years (SD 12.6).


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 783 - 791
1 Aug 2024
Tanaka S Fujii M Kawano S Ueno M Nagamine S Mawatari M

Aims

The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia.

Methods

We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 775 - 782
1 Aug 2024
Wagner M Schaller L Endstrasser F Vavron P Braito M Schmaranzer E Schmaranzer F Brunner A

Aims

Hip arthroscopy has gained prominence as a primary surgical intervention for symptomatic femoroacetabular impingement (FAI). This study aimed to identify radiological features, and their combinations, that predict the outcome of hip arthroscopy for FAI.

Methods

A prognostic cross-sectional cohort study was conducted involving patients from a single centre who underwent hip arthroscopy between January 2013 and April 2021. Radiological metrics measured on conventional radiographs and magnetic resonance arthrography were systematically assessed. The study analyzed the relationship between these metrics and complication rates, revision rates, and patient-reported outcomes.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims

Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon.

Methods

A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 53 - 59
19 Jan 2024
Bialaszewski R Gaddis J Laboret B Bergman E Mulligan EP LaCross J Stewart A Wells J

Aims

Social media is a popular resource for patients seeking medical information and sharing experiences. periacetabular osteotomy (PAO) is the gold-standard treatment for symptomatic acetabular dysplasia with good long-term outcomes. However, little is known regarding the perceived outcomes of PAO on social media. The aims of this study were to describe the perceived outcomes following PAO using three social media platforms: Facebook, Instagram, and X (formerly known as Twitter).

Methods

Facebook, Instagram, and X posts were retrospectively collected from 1 February 2023. Facebook posts were collected from the two most populated interest groups: “periacetabular osteotomy” and “PAO Australia.” Instagram and X posts were queried using the most popular hashtags: #PAOwarrior, #periacetabularosteotomy, #periacetabularosteotomyrecovery, #PAOsurgery, and #PAOrecovery. Posts were assessed for demographic data (sex, race, location), perspective (patient, physician, professional organization, industry), timing (preoperative vs postoperative), and perceived outcome (positive, negative, neutral).


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims

Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up.

Methods

We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims

To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia.

Methods

We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure.


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims

This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices.

Methods

Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 174 - 183
6 Mar 2024
Omran K Waren D Schwarzkopf R

Aims

Total hip arthroplasty (THA) is a common procedure to address pain and enhance function in hip disorders such as osteoarthritis. Despite its success, postoperative patient recovery exhibits considerable heterogeneity. This study aimed to investigate whether patients follow distinct pain trajectories following THA and identify the patient characteristics linked to suboptimal trajectories.

Methods

This retrospective cohort study analyzed THA patients at a large academic centre (NYU Langone Orthopedic Hospital, New York, USA) from January 2018 to January 2023, who completed the Patient-Reported Outcomes Measurement Information System (PROMIS) pain intensity questionnaires, collected preoperatively at one-, three-, six-, 12-, and 24-month follow-up times. Growth mixture modelling (GMM) was used to model the trajectories. Optimal model fit was determined by Bayesian information criterion (BIC), Vuong-Lo-Mendell-Rubin likelihood ratio test (VLMR-LRT), posterior probabilities, and entropy values. Association between trajectory groups and patient characteristics were measured by multinomial logistic regression using the three-step approach.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 924 - 932
23 Dec 2022
Bourget-Murray J Horton I Morris J Bureau A Garceau S Abdelbary H Grammatopoulos G

Aims

The aims of this study were to determine the incidence and factors for developing periprosthetic joint infection (PJI) following hemiarthroplasty (HA) for hip fracture, and to evaluate treatment outcome and identify factors associated with treatment outcome.

Methods

A retrospective review was performed of consecutive patients treated for HA PJI at a tertiary referral centre with a mean 4.5 years’ follow-up (1.6 weeks to 12.9 years). Surgeries performed included debridement, antibiotics, and implant retention (DAIR) and single-stage revision. The effect of different factors on developing infection and treatment outcome was determined.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 692 - 700
2 Sep 2022
Clement ND Smith KM Baron YJ McColm H Deehan DJ Holland J

Aims

The primary aim of our study was to assess the influence of age on hip-specific outcome following total hip arthroplasty (THA). Secondary aims were to assess health-related quality of life (HRQoL) and level of activity according to age.

Methods

A prospective cohort study was conducted. All patients were fitted with an Exeter stem with a 32 mm head on highly cross-linked polyethylene (X3RimFit) cemented acetabulum. Patients were recruited into three age groups: < 65 years, 65 to 74 years, and ≥ 75 years, and assessed preoperatively and at three, 12, 24, and 60 months postoperatively. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), and Hip disability and Osteoarthritis Outcome Score (HOOS), were used to assess hip-specific outcome. EuroQol five-dimension five-level questionnaire (EQ-5D-5L) and 36-Item Short Form Survey (SF-36) scores were used to assess HRQoL. The Lower Extremity Activity Scale (LEAS) and Timed Up and Go (TUG) were used to assess level of activity.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 844 - 851
1 Jul 2022
Rogmark C Nåtman J Jobory A Hailer NP Cnudde P

Aims

Patients with femoral neck fractures (FNFs) treated with total hip arthroplasty (THA) have an almost ten-fold increased risk of dislocation compared to patients undergoing elective THA. The surgical approach influences the risk of dislocation. To date, the influence of differing head sizes and dual-mobility components (DMCs) on the risk of dislocation has not been well studied.

Methods

In an observational cohort study on 8,031 FNF patients with THA between January 2005 and December 2014, Swedish Arthroplasty Register data were linked with the National Patient Register, recording the total dislocation rates at one year and revision rates at three years after surgery. The cumulative incidence of events was estimated using the Kaplan-Meier method. Cox multivariable regression models were fitted to calculate adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) for the risk of dislocation, revision, or mortality, stratified by surgical approach.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 10 - 10
1 Oct 2020
Moskal JT
Full Access

Background. The use of the direct anterior approach (DAA) for total hip arthroplasty (THA) has increased in recent years. This is in part due to the proposed benefits of a faster early recovery and a lower risk of dislocation. The purpose of this study is to understand the dislocation rate in a non-selective, consecutive cohort of patients undergoing THA via the DAA including those at high risk for instability due to spinopelvic pathology. Methods. We performed a retrospective review of a large prospectively collected single institution database assessing all patients undergoing THA via the DAA between 2011 and 2017. The primary outcome measure was dislocation at minimum two-year follow-up. We then stratified patients by known risk factors for dislocation including spinopelvic pathology and performed an in-depth analysis of those patients who had a dislocation event. Results. 2,831 hips in 2205 patients were included in the study. Mean age was 64.9 (24–96) and 1,595 (56.3%) were female. Mean BMI was 29.2 (15.1–53.8). There were 11 dislocations within one year of the index operation (0.38%) and 13 total dislocations at terminal follow-up (0.45%). Five dislocations required revision (38.4% of dislocations 0.17% overall). When stratified by experience the dislocation rate for surgeons who had completed their learning curve was 0.15% compared to 1.11% in those who hadn't. There were 666 patients with an established diagnosis of spinopelvic pathology or prior surgical instrumentation, only 2 (0.30%) dislocated and neither required revision. Conclusion. In a non-selective, consecutive cohort of patients undergoing THA via the DAA the risk of dislocation is low. Even amongst patients with lumbosacral stiffness secondary to spinal instrumentation or degenerative changes, the rate of dislocation is low following THA via the DAA. Our data suggests that utilizing the DAA in high risk patients may be protective against dislocation without the need for additional constraint or the use of newer bearing constructs that lack long term outcome studies. The inclusion of seven surgeons suggests that these results are generalizable


Bone & Joint Open
Vol. 3, Issue 3 | Pages 196 - 204
4 Mar 2022
Walker RW Whitehouse SL Howell JR Hubble MJW Timperley AJ Wilson MJ Kassam AM

Aims

The aim of this study was to assess medium-term improvements following total hip arthroplasty (THA), and to evaluate what effect different preoperative Oxford Hip Score (OHS) thresholds for treatment may have on patients’ access to THA and outcomes.

Methods

Patients undergoing primary THA at our institution with an OHS both preoperatively and at least four years postoperatively were included. Rationing thresholds were explored to identify possible deprivation of OHS improvement.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 229 - 235
11 Mar 2022
Syam K Unnikrishnan PN Lokikere NK Wilson-Theaker W Gambhir A Shah N Porter M

Aims

With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases.

Methods

A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 6 - 6
1 Jul 2020
Hall A Holt G
Full Access

Background. National hip fracture programmes are becoming widespread, but this practice is nascent and varied. The Scottish Hip Fracture Audit (SHFA) was an early adopter of this strategy and is credited with substantial systemic improvements in quality and outcomes. Objectives. To provide evidence and incentive to clinicians and administrators to adopt successful improvement strategies, and to facilitate data-driven change hip fracture care. Study Design and Methods. We reviewed the practice of seven national hip fracture improvement programmes in: Sweden, Denmark, Norway, Australia, New Zealand, UK, Scotland, and Ireland. We report our experience from the SHFA and describe: the results of our programme; challenges and learning points encountered, and successful strategies for implementing change. Results. There is variance in approach to data collection and reporting, for example: standalone programmes versus combined trauma and arthroplasty registries; annual trend reporting versus ‘snapshot’ or real-time information; population-level versus patient-level data, and the emphasis placed on service-level characteristics. The governance model also varies – some act as a passive data registry whereas others act as active agents of change and regulation. There is consensus on the key performance makers: prompt admission; early surgery and mobilisation, and a multidisciplinary approach. There have been significant challenges encountered by the SHFA with respect to funding, logistical, and political issues. Analysis of the effects of our programme have demonstrated its clinical efficacy, and has identified successful strategies for improvement. We describe this experience. Conclusions. The establishment of national audit programmes has resulted in significant improvements in quality, efficiency, and outcomes. This study of major national programmes provides evidence, incentive, and instruction to clinicians and administrators who seek to improve healthcare systems