Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 54 - 54
1 Nov 2016
Birch C Blankstein M Bartlett C
Full Access

Periprosthetic femoral shaft fractures are a significant complication of total hip arthroplasty. Plate osteosynthesis with or without onlay strut allograft has been the mainstay of treatment around well-fixed stems. Nonunions are a rare, challenging complication of this fixation method. The number of published treatment strategies for periprosthetic femoral nonunions are limited. In this series, we report the outcomes of a novel orthogonal plating surgical technique for addressing nonunions in the setting of Vancouver B1 and C-type periprosthetic fractures that previously failed open reduction internal fixation (ORIF). A retrospective chart review of all patients from 2010 to 2014 with Vancouver B1/C total hip arthroplasty periprosthetic femoral nonunions was performed. All patients were treated primarily with ORIF. Nonunion was defined as no radiographic signs of fracture healing nine months post-operatively, with or without hardware failure. Exclusion criteria included open fractures and periprosthetic infections. The technique utilised a mechanobiologic strategy of atraumatic exposure, resection of necrotic tissue, bone grafting with adjuvant recombinant growth factor and revision open reduction internal fixation. Initially, compression was achieved using an articulated tensioning device and application of an anterior plate. This was followed by locked lateral plating. Patients remained non-weight bearing for eight weeks. Six Vancouver B1/C periprosthetic femoral nonunions were treated. Five patients were female with an average age of 80.3 years (range 72–91). The fractures occurred at a mean of 5.8 years (range 1–10) from their initial arthroplasty procedure. No patients underwent further revision surgery; there were no wound dehiscence, hardware failures, infections, or surgical complications. All patients had a minimum of nine months follow up (mean 16.6, range 9–36). All fractures achieved osseous union, defined as solid bridging callus over at least two cortices and pain free, independent ambulation, at an average of 24.4 weeks (range 6.1–39.7 weeks). To our knowledge, this is the first case series describing 90–90 locked compression plating using modern implants for periprosthetic femoral nonunions. This is a rare but challenging complication of total hip arthroplasty and we present a novel solution with satisfactory preliminary outcomes. Orthogonal locked compression plating utilising an articulated tensioning device and autograft with adjuvant osteoinductive allograft should be considered in periprosthetic femur fractures around a well-fixed stem. Further biomechanical and clinical research is needed to improve our treatment strategies in this population


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 28 - 28
1 Dec 2014
Naikoti KK Sylvan A WynnJones H Shah N Clayson A
Full Access

The radiological evidence of implant failure following plate fixation of traumatic pubic symphysis diastasis can be up to 75%. We report the complications following symphyseal double orthogonal plating in patients with pubic symphysis diastasis over a period of 2.5 years. Patient records and radiographs of 38 consecutive patients were reviewed with mean follow up of 12.5 months. 5 patients (13%) had radiological evidence of implant failure with one patient (2.6%) requiring revision surgery. There was no evidence of wound complications. We conclude that our lower rate of revision surgery and metal work failure is attributed to double orthogonal plating


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 89 - 89
1 Dec 2022
Kitzen J Paulson K Edwards B Bansal R Korley R Duffy P Dodd A Martin R Schneider P
Full Access

Dual plate constructs have become an increasingly common fixation technique for midshaft clavicle fractures and typically involve the use of mini-fragment plates. The goal of this technique is to reduce plate prominence and implant irritation, as these are common reasons for revision surgery. However, limited biomechanical data exist for these lower-profile constructs. The study aim was to compare dual mini-fragment orthogonal plating to traditional small-fragment clavicle plates for biomechanical non-inferiority and to determine if an optimal plate configuration could be identified, using a cadaveric model. Twenty-four cadaveric clavicles were randomized to one of six groups (n=4 per group), stratified by CT-based bone mineral content (BMC). The six different plating configurations compared were: pre-contoured superior or anterior fixation using a single 3.5-mm LC-DC plate, and four different dual-plating constructs utilizing 2.4-mm and 2.7-mm reconstruction or LC-DC plates. The clavicles were plated and then osteotomized to create an inferior butterfly fracture, which was then fixed with a single interfragmentary screw (OTA 15.2B). Axial, torsional, and bending (anterior and superior surface loading) stiffness were determined for each construct through non-destructive cyclic testing, using an MTS 858 Bionix materials testing system. This was followed by a load-to-failure test in three-point superior-surface bending. Kruskal-Wallace H and Mann-Whitney U were used to test for statistical significance. There were no significant differences in BMC (median 7.9 g, range 4.2-13.8 g) for the six groups (p=1.000). For axial stiffness, the two dual-plate constructs with a superior 2.4-mm and anterior 2.7-mm plate (either reconstruction or LC-DC) were significantly stiffer than the other four constructs (p=0.021). For both superior and anterior bending, the superior 2.4-mm and anterior 2.7-mm plate constructs were significantly stiffer when compared to the 3.5-mm superior plate (p=0.043). In addition, a 3.5-mm plate placed anterior was a stiffer construct than a superior 3.5-mm plate (p=0.043). No significant differences were found in torsional stiffness or load-to-failure between the different constructs. Dual plating using mini-fragment plates is biomechanically superior for fixation of midshaft clavicle fractures when compared to a single superior 3.5-mm plate and has similar biomechanical properties to a 3.5-mm plate placed anteriorly. With the exception of axial stiffness, no significant differences were found when different dual plating constructs were compared to each other. However, placing a 2.4-mm plate superiorly in combination with a 2.7-mm plate anteriorly might be the optimal construct, given the biomechanical superiority over the 3.5-mm plate placed superior