Advertisement for orthosearch.org.uk
Results 1 - 20 of 47
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 151 - 157
1 Feb 2024
Dreyer L Bader C Flörkemeier T Wagner M

Aims. The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection. Methods. We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022. Results. Two mechanical failure patterns were identified: fractures in the area of the distal fluted profile (distal stem fracture) and failure of the modular taper (modular fracture). A failure rate of 0.07% was observed for distal stem fracture, and modular fracture rates of 1.74% for the original and 0.013% for the current taper design. Conclusion. A low risk of mechanical failure for both fracture types was observed compared to other known complications in revision hip arthroplasty. In addition, the data show that a design change did significantly reduce the risk of a modular fracture. Cite this article: Bone Joint J 2024;106-B(2):151–157


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1031 - 1037
1 Aug 2015
da Assunção RE Pollard TCB Hrycaiczuk A Curry J Glyn-Jones S Taylor A

Periprosthetic femoral fracture (PFF) is a potentially devastating complication after total hip arthroplasty, with historically high rates of complication and failure because of the technical challenges of surgery, as well as the prevalence of advanced age and comorbidity in the patients at risk. This study describes the short-term outcome after revision arthroplasty using a modular, titanium, tapered, conical stem for PFF in a series of 38 fractures in 37 patients. The mean age of the cohort was 77 years (47 to 96). A total of 27 patients had an American Society of Anesthesiologists grade of at least 3. At a mean follow-up of 35 months (4 to 66) the mean Oxford Hip Score (OHS) was 35 (15 to 48) and comorbidity was significantly associated with a poorer OHS. All fractures united and no stem needed to be revised. Three hips in three patients required further surgery for infection, recurrent PFF and recurrent dislocation and three other patients required closed manipulation for a single dislocation. One stem subsided more than 5 mm but then stabilised and required no further intervention. . In this series, a modular, tapered, conical stem provided a versatile reconstruction solution with a low rate of complications. Cite this article: Bone Joint J 2015;97-B:1031–7


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 33 - 40
1 Jul 2020
Gustafson JA Pourzal R Levine BR Jacobs JJ Lundberg HJ

Aims

The aim of this study was to develop a novel computational model for estimating head/stem taper mechanics during different simulated assembly conditions.

Methods

Finite element models of generic cobalt-chromium (CoCr) heads on a titanium stem taper were developed and driven using dynamic assembly loads collected from clinicians. To verify contact mechanics at the taper interface, comparisons of deformed microgroove characteristics (height and width of microgrooves) were made between model estimates with those measured from five retrieved implants. Additionally, these models were used to assess the role of assembly technique—one-hit versus three-hits—on the taper interlock mechanical behaviour.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 50 - 53
1 Jan 2016
Konan S Garbuz DS Masri BA Duncan CP

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that reason, and while awaiting intermediate-term results of more recently introduced designs of this junction, non-modularity has attracted attention, at least for straightforward revision cases.

We review the risks and causes of fracture of tapered titanium modular revision stems and present an argument in favour of the more selective use of modular designs.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):50–3.


Aims. Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods. A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results. One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion. The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes. Cite this article: Bone Joint J 2024;106-B(4):344–351


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 889 - 895
1 Jul 2014
Fink B Urbansky K Schuster P

We report our experience of revision total hip replacement (THR) using the Revitan curved modular titanium fluted revision stem in patients with a full spectrum of proximal femoral defects. A total of 112 patients (116 revisions) with a mean age of 73.4 years (39 to 90) were included in the study. The mean follow-up was 7.5 years (5.3 to 9.1). A total of 12 patients (12 hips) died but their data were included in the survival analysis, and four patients (4 hips) were lost to follow-up. The clinical outcome, proximal bone regeneration and subsidence were assessed for 101 hips.

The mean Harris Hip Score was 88.2 (45.8 to 100) after five years and there was an increase of the mean Barnett and Nordin-Score, a measure of the proximal bone regeneration, of 20.8 (-3.1 to 52.7). Five stems had to be revised (4.3%), three (2.9%) showed subsidence, five (4.3%) a dislocation and two of 85 aseptic revisions (2.3%) a periprosthetic infection.

At the latest follow-up, the survival with revision of the stem as the endpoint was 95.7% (95% confidence interval 91.9% to 99.4%) and with aseptic loosening as the endpoint, was 100%. Peri-prosthetic fractures were not observed.

We report excellent results with respect to subsidence, the risk of fracture, and loosening after femoral revision using a modular curved revision stem with distal cone-in-cone fixation. A successful outcome depends on careful pre-operative planning and the use of a transfemoral approach when the anatomy is distorted or a fracture is imminent, or residual cement or a partially-secured existing stem cannot be removed. The shortest appropriate stem should, in our opinion, be used and secured with > 3 cm fixation at the femoral isthmus, and distal interlocking screws should be used for additional stability when this goal cannot be realised.

Cite this article: Bone Joint J 2014;96-B:889–95.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims. United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. Methods. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up. Results. For the total cohort, stem osseointegration, fracture union, and stem subsidence were 98.6%, 98.6%, and 6.9%, respectively, at latest follow-up (mean follow-up 27.0 months (SD 22.4)). For patients with minimum one-year of follow-up, stem osseointegration, fracture union, and stem subsidence were 97.8%, 97.8%, and 6.5%, respectively. Conclusion. Monoblock fluted stems can be an acceptable modality for the management of UCS B2 periprosthetic fractures in rTHAs due to high rates of stem osseointegration and survival, and the low rates of stem subsidence, and revision. Further research on the use of this stem for UCS B3 periprosthetic fractures is warranted to determine if the same conclusion can be made for this fracture pattern. Cite this article: Bone Jt Open 2023;4(8):551–558


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 13 - 13
1 Oct 2019
Gustafson JA Levine BR Jacobs JJ Pourzal R Lundberg HJ
Full Access

Introduction. Improper seating during head/stem assembly can lead to unintended micromotion between the femoral head and stem taper—resulting in fretting corrosion and implant failure. 1. There is no consensus—either by manufacturers or by the surgical community—on what head/stem taper assembly method maximizes modular junction stability in total hip arthroplasty (THA). A 2018 clinical survey. 2. found that orthopedic surgeons prefer applying one strike or three, subsequent strikes when assembling head/stem taper. However, it has been suggested that additional strikes may lead to decreased interference strength. Additionally, the taper surface finish—micro-grooves—has been shown to affect taper interference strength and may be influenced by assembly method. The objective of this study was to employ a novel, micro-grooved finite element (FEA) model of the hip taper interface and assess the role of head/stem assembly method—one vs three strikes—on modular taper junction stability. Methods. A two-dimensional, axisymmetric FEA model representative of a CoCrMo femoral head taper and Ti6Al4V stem taper was created using median geometrical measurements taken from over 100 retrieved implants. 3. Surface finish—micro-grooves—of the head/stem taper were modeled using a sinusoidal function with amplitude and period corresponding to retrieval measurements of micro-groove height and spacing, respectively. Two stem taper micro-groove geometries— “rough” and “smooth”—were modeled corresponding to the median and 5. th. percentile height and spacing measurements from retrievals. All models had a 3' (0.05°), proximal-locked angular mismatch between the tapers. To simulate implant assembly during surgery, multiple dynamic loads (4kN, 8kN, and 12kN) were applied to the femoral head taper in a sequence of one or three strikes. The input load profile (Figure 1) used for both cases was collected from surgeons assembling an experimental setup with a three-dimensional load sensor. Models were assembled and meshed in ABAQUS Standard (v 6.17) using four-node linear hexahedral, reduced integration elements. Friction was modeled between the stem and head taper using surface-to-surface formulation with penalty contact (µ=0.2). A total of 12 implicit, dynamic simulations (3 loads × 2 assembly sequences × 2 stem taper surface finishes) were run, with 2 static simulations at 4kN for evaluating inertial effects. Outcome variables included contact area, contact pressure, equivalent plastic strain, and pull-off force. Results. As expected, increasing assembly load led to increased contact area, pressures, and plasticity for both taper finishes. Rough tapers exhibited less total contact area at each loading level as compared to the smooth taper. Contact pressures were relatively similar across the stem taper finishes, except the 3-strike smooth taper, which exhibited the lowest contact pressures (Figure 2) and pull-off forces. The models assembled with one strike exhibited the greatest contact pressures, pull-off forces, and micro-groove plastic deformation (Figure 3). Conclusion. Employing 1-strike loads led to greater contact areas, pressures, pull-off forces, and plastic deformation of the stem taper micro-grooves as compared to tapers assembled with three strikes. Residual energy may be lost with subsequent assembly strikes, suggesting that one, firm strike maximizes taper assembly mechanics. These models will be used to identify the optimal design factors and impaction method to maximize stability of modular taper junctions. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 14 - 14
1 Jan 2018
Russell R Nwelue E Schell B Huo M
Full Access

Modular tapered stems have become increasingly popular in femoral revisions and stem subsidence remains a reported clinical problem. Computer modeling and biomechanical testing demonstrated a minimum initial line-to-line fit of 25 mm was required to reduce the risk of subsidence. We examined XR imaging of 110 consecutive femoral revisions by a single surgeon using two different modular tapered stems to determine if this biomechanical threshold was of clinical relevance. 72% of the revisions were done for aseptic loosening and 28% for periprosthetic fracture or infection. Stem subsidence of any degree was observed in 24 (21.8%), while 12 (10.9%) demonstrated substantial subsidence of > 10 mm. We matched this cohort to 12 patients who had no stem subsidence. The average age of patients with subsidence was 59 years (43 to 79 years). The average of patients without subsidence was 66 years (41 to 77 years). Each group had 7 men and 5 women. Stem subsidence was observed in the first 3 months post-surgery. The demographics, bone deficiency, stem design, and stem diameter were similar between groups. 83% of patients with substantial stem subsidence had less than 25 mm of line-to-line fit compared to 17% of patients without subsidence. The 12 cases of no stem subsidence had a mean line-to-line fit of 48 mm (25 to 55 mm). 75% of patients with substantial stem subsidence had also undergone an extended trochanteric osteotomy (ETO) compared to 33% of patients without subsidence. We conclude that there is a positive correlation with the biomechanical testing parameters and substantial stem subsidence. ETO was found to be associated with higher stem subsidence


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 95 - 97
1 Nov 2013
Cross MB Paprosky WG

If a surgeon is faced with altered lesser trochanter anatomy when revising the femoral component in revision total hip replacement, a peri-prosthetic fracture, or Paprosky type IIIb or type IV femoral bone loss, a modular tapered stem offers the advantages of accurately controlling femoral version and length. The splines of the taper allow rotational control, and improve the fit in femoral canals with diaphyseal bone loss. In general, two centimetres of diaphyseal contact is all that is needed to gain stability with modular tapered stems. By allowing the proximal body trial to rotate on a well-fixed distal segment during trial reduction, appropriate anteversion can be obtained in order to improve intra-operative stability, and decrease the dislocation risk. However, modular stems should not be used for all femoral revisions, as implant fracture and corrosion at modular junctions can still occur. Cite this article: Bone Joint J 2013;95-B, Supple A:95–7


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 48 - 48
23 Jun 2023
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP
Full Access

There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems. We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m. 2. , and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized. The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up. This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI. Level of Evidence: IV


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 2 - 2
1 Jun 2017
Crainic A Callisti M Palmer M Cook R
Full Access

Metallic contacts in hip replacements are susceptible to wear and corrosion processes which lead to the release of particles and metal ions. Adverse local tissue reactions (ALTRs) and systemic manifestations to solid and soluble debris can be debilitating for the patients. It is believed that particles originating from CoCrMo taper junctions trigger more severe body reactions compared to debris from MoM hip bearings. The body's reaction is highly dependent on particle characteristics, such as size, morphology, composition and aggregation state, which can reflect the specific wear and corrosion conditions at the site of release. Here we proposed to investigate wear and corrosion flakes collected from around CoCrMo tapers at the time of revision. The particles were initially characterised with scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). This revealed the microstructure of the corrosion products, which appeared to be made of smaller metallic aggregates, entrapped in a biological matrix. The in depth characterisation of the particles released from the organo-metallic composite, was performed with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM), both fitted with EDX. The investigation revealed clusters and individual nanoparticles, as small as 3 nm, which represent the building blocks of the large corrosion flakes, reported and characterised in the past mainly with low resolution microscopy techniques. The majority of the particles consisted of Cr and O, potentially in the form of chromium oxides, with little evidence of Co and Mo. Particles size distribution (PSD) provided by STEM and TEM characterisation showed statistically different results. The STEM technique was able to resolve tiny particles found in close proximity and provided a PSD shift towards the smaller end of the size range. The study is the first to show microscopy evidence of Cr rich nanoparticles (3–60 nm) released in vivo from the modular taper interface, which can have important health implications caused by their increased potential to disseminate and corrode within the body


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 5 - 5
1 Jan 2018
Haidukewych G Shekailo P Yoon R
Full Access

There is a paucity of available literature to guide the surgeon treating postoperative fractures of the greater trochanter after femoral component revision. Between 2009 and 2016, 133 patients underwent femoral component revision by the senior author utilizing a modular tapered fluted titanium stem. 17 patients died or had inadequate follow-up. Therefore, 116 patients were included in the final analysis. There were 58 males and 58 females with a mean age of 64 (range 23 to 91 years old). Clinical and radiographic data were analyzed for postoperative greater trochanteric fracture (GTfx). Mean clinical follow up was 21 months (range 3 to 77 mos). Age, BMI, preoperative diagnosis, comorbidities, reason for revision, use of Extended Trochanteric Osteotomy (ETO), fixation method of ETO, presence of prior hardware, post-operative trauma (falls), femoral component size and offset, change in leg length were analyzed to determine potential risk factors for postoperative GT fracture. There were 7 postoperative greater trochanteric fractures in 7 patients (6%). Of these, 1 occurred as a result of a postoperative fall, 1 occurred after dislocation, and 1 occurred after a fall with a subsequent dislocation. The mean time to diagnosis of the fracture was 10.7 weeks postoperatively (range one day to 37.4 weeks). 52 of 116 patients had their revision performed through an ETO. Of those, 6 had a postoperative fracture of the GT. The use of an ETO significantly increased the likelihood of postoperative GT fx (p=0.035). Regarding femoral component size, use of a longer proximal body (+10 or greater) was associated with an increased risk of postoperative GT fx (p=0.07). Two fractures were minimally (<1cm) or non-displaced and were treated non-operatively. Of these fractures, 1 united. The other fracture further displaced and resulted in recurrent instability. This was treated with excision of the fragment and a constrained liner. 5 fractures were displaced and were treated with ORIF. 3 were fixed with a cable grip device, 1 was plated, and 1 was treated with a cable grip device and a constrained liner. Of those treated with some form of ORIF, all 5 healed. Of those that underwent surgical fixation initially, 3 reported residual trochanteric pain and 1 patient had their hardware removed (trochanteric claw). 2 of these patients have a residual limp and require a cane for use as a gait aid. The patient treated non-surgically required a cane as did the patient that failed non-surgical treatment. Post-operative greater trochanteric fractures are a rare complication of femoral component revision. The use of an ETO significantly increased the rate of post of GTfx. The mean time to diagnosis of was 11 weeks. Displaced fractures of the greater trochanter treated with ORIF all healed, both cable grip devices and plates were effective. Residual limp requiring gait aids and residual trochanteric pain were common outcomes after fixation of these fractures despite successful union


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 32 - 32
1 Jun 2016
Sharma V Shamoon R Maheson M Jones SA
Full Access

Introduction. The Corail stem is a fully HA coated tapered implant that has demonstrated long-term success. On the NJR it has become one of the most commonly used implants in the UK. The aim of our study was to document our experience of the revision of this implant together highlighting some important technical considerations. Patients/Materials & Methods. A retrospective review of a consecutive case series of revision procedures where the Corail stem was extracted. We considered time since implantation, collared or uncollared design, indication for revision, Paprosky classification of femoral deficiency, endo-femoral reconstruction or extended approach/osteotomy, subsequent reconstruction either further primary type implant (cemented or cementless) or revision femoral implant. Results. 49 patients required extraction of Corial Stem as part of revision THA. Mean time to extraction 5.2 years (range 1.1 to 10.5 years). Indication for revision in 27 cases ARMD, 7 aseptic loosening, 7 PJI, 6 Peri-prosthetic fractures and 2 instability. The only cases that utilised an extended approach were those performed for peri-prosthetic fracture (5 B2 & 1 Type C fractures) all of which were reconstructed with a Modular Taper Fluted Stem. Of the remaining 43 cases revised for other reasons femoral bone stock was Paprosky Grade 2 in 21 cases, grade 3A in 22 cases. Stems were extracted with implant specific extraction device via endo-feomral route and subsequent reconstruction utilised a primary type femoral implant in 34% of cases. Discussion. All stems, apart from those revised for peri-prosthetic fracture were reconstructed via endo-femoral route. Safe implant extraction is key in this approach and the success of this method in our series emphasizes the major importance of the implant specific extraction instrumentation. Conclusion. As a result of safe implant extraction over 1/3. rd. of patients were able to have a primary implant inserted at the time of revision surgery


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 4 - 4
1 Nov 2015
Osman K Panagiotidou A Meswania J Skinner J Hart A Haddad F Blunn G
Full Access

Introduction. Recent studies on large diameter femoral head hip replacements have implicated the modular taper junction as one of the significant sources of wear and corrosion products and this has been attributed to increased torque and bending on the taper interface. The aim of this study was to assess the effect of frictional torque and bending moment on fretting corrosion at the taper junction and to investigate whether different material combinations also had an effect. Patients/Materials & Methods. We examined 1) Cobalt Chromium (CoCr) heads on CoCr stems 2) CoCr heads on Titanium alloy (Ti) stems and 3) Ceramic heads on CoCr stems. In test 1 increasing torque was imposed by offsetting the femoral stem in the anterior posterior plane in increments of 0 mm, 4 mm, 6 mm and 8 mm where the force generated was equivalent to 0Nm, 9Nm, 14Nm and 18Nm. In Test 2 we investigated the effect of increasing bending moment by offsetting the application of axial load from the midline in the medial-lateral (ML). Offset increments equivalent to +0, +7 and +14 heads were used. For each test we used n=3 for each different material combination. Results. Significantly higher currents and amplitudes were seen with increasing frictional torque for all material combinations, however titanium alloy stems showed the highest corrosion. Increasing bending moments associated with using larger off-set heads produced more corrosion; with titanium alloy stems generally performing worse than cobalt chrome stems. Using ceramic heads did not prevent corrosion, but this was significantly reduced in all loading configurations. Discussion & Conclusion. This is the first study to quantify corrosion associated with different material combinations and loading conditions. Increasing frictional torque and bending, together with the material combination have a significant effect on the fretting corrosion at the taper modular junction. The best performing material combination was ceramic on CoCr


The early failure and revision of bimodular primary total hip arthroplasty prostheses requires the identification of the risk factors for material loss and wear at the taper junctions through taper wear analysis. Deviations in taper geometries between revised and pristine modular neck tapers were determined using high resolution tactile measurements. A new algorithm was developed and validated to allow the quantitative analysis of material loss, complementing the standard visual inspection currently used. The algorithm was applied to a sample of 27 retrievals (in situ from 2.9 to 38.1 months) of the withdrawn Rejuvenate modular prosthesis. The mean wear volumes on the flat distal neck piece taper was 3.35 mm. 3. (0.55 to 7.57), mainly occurring in a characteristic pattern in areas with high mechanical loading. Wear volume tended to increase with time to revision (r² = 0.423, p = 0.001). Implant and patient specific data (offset, stem size, patient’s mass, age and body mass index) did not correlate with the amount of material loss observed (p >  0.078). Bilaterally revised implants showed higher amounts of combined total material loss and similar wear patterns on both sides. The consistent wear pattern found in this study has not been reported previously, suggesting that the device design and materials are associated with the failure of this prosthesis. Cite this article: Bone Joint J 2015;97-B:1350–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 281 - 286
1 Feb 2012
Chana R Esposito C Campbell PA Walter WK Walter WL

We report a case of a male patient presenting with bilateral painful but apparently well-positioned and -fixed large-diameter metal-on-metal hip replacements four years post-operatively. Multiple imaging modes revealed a thick-walled, cystic expansile mass in communication with the hip joint (a pseudotumour). Implant retrieval analysis and tissue culture eliminated high bearing wear or infection as causes for the soft-tissue reaction, but noted marked corrosion of the modular neck taper adaptor and corrosion products in the tissues. Therefore, we believe corrosion products from the taper caused by mismatch of the implant components led to pseudotumour formation requiring revision


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 598 - 603
1 May 2022
Siljander MP Gausden EB Wooster BM Karczewski D Sierra RJ Trousdale RT Abdel MP

Aims

The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes.

Methods

We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m2 (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 24 - 24
1 Jan 2018
Heckmann N Sivasundaram L Stefl M Kang H Basler E Lieberman J
Full Access

The bearing surface is the critical element in determining the longevity of a total hip arthroplasty. Over the past decade problems associated with bearing surfaces and modular femoral tapers have had an impact on surgeon selection of both acetabular liners and modular femoral heads. The purpose of this study was to analyse THA bearing surface trends from 2007 through 2014 using a large national database. A retrospective review of the Nationwide Inpatient Sample (NIS) database was conducted from 2007 to 2014. All patients who underwent a primary THA were identified using International Classification of Diseases, 9th edition (ICD-9) procedure codes. Bearing surface data was extracted by identifying patients with ICD-9 procedure modifier codes. Patient and hospital characteristics were recorded for each patient. Descriptive statistics were employed to characterise bearing surface trends for the following bearing surfaces: metal on polyethylene (MoP); ceramic on polyethylene (CoP); ceramic on ceramic (CoC) and metal on metal (MoM). Univariate analysis was performed to identify differences between the bearing surface groups. During the study period, 2,460,640 primary THA discharges were identified, of which 1,059,825 (43.1%) had bearing surface data available for further analysis. The breakdown of the bearing surfaces used for these THAs were as follows: MoP − 49.1% (496,713); CoP − 29.1% (307,907); CoC − 4.2% (44,823); and MoM − 19.9% (210,381). MoM utilization peaked in 2008 with 51,033 cases representing 40.1% of THAs implanted that year. The usage steadily declined and by 2014 there were only 6,600 MoM cases representing only 4.0% of the THAs. From 2007 to 2014, the use of CoP bearing surfaces increased from 11,482 discharges (11.1% of cases) in 2007, to 83,300 discharges (50.8% of cases) in 2014. CoP utilization surpassed MoP in 2014. MoP accounted for 54.7% of discharges in 2011 and just 42.1% in 2014. During the study period, MoM bearing surface usage declined precipitously, while CoP surpassed MoP as the most prevalent bearing surface used in total hip arthroplasty patients. These changes in bearing surface usage over time were clearly influenced by concerns regarding high failure rates associated with MoM articulations and reports of taper corrosion associated with modular metal femoral heads


Bone & Joint Open
Vol. 3, Issue 3 | Pages 229 - 235
11 Mar 2022
Syam K Unnikrishnan PN Lokikere NK Wilson-Theaker W Gambhir A Shah N Porter M

Aims

With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases.

Methods

A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS).