Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 73 - 73
4 Apr 2023
Tolgyesi A Huang C Akens M Hardisty M Whyne C
Full Access

Bone turnover and microdamage are impacted by skeletal metastases which can contribute to increased fracture risk. Treatments for metastatic disease may further impact bone quality. This study aimed to establish an understanding of microdamage accumulation and load to failure in healthy and osteolytic vertebrae following cancer treatment (stereotactic body radiotherapy (SBRT), zoledronic acid (ZA), or docetaxel (DTX)). Forty-two 6-week old athymic female rats (Hsd:RH-Foxn1rnu, Envigo) were studied; 22 were inoculated with HeLa cervical cancer cells through intracardiac injection (day 0). Animals were randomly assigned to four groups: untreated (healthy=5, osteolytic=6), SBRT on day 14 (healthy=6, osteolytic=6), ZA on day 7 (healthy=4, osteolytic=5), and DTX on day 14 (healthy=5, osteolytic=5). Animals were euthanized on day 21. L1-L3 motion segments were compression loaded to failure and force-displacement data recorded. T13 vertebrae were stained with BaSO. 4. and µCT imaged (90kVp, 44uA, 4.9µm) to visualize microdamage location and volume. Damage volume fraction (DV/BV) was calculated as the ratio of BaSO. 4. to bone volume. Differences in mean load-to-failure were compared using three-way ANOVA (disease status, treatment, cells injected). Differences in mean DV/BV between treatment groups were compared using one-way ANOVA. Treatment had a significant effect on load-to-failure (p=0.004) with ZA strengthening the healthy and osteolytic vertebrae. Reduced strength post SBRT seen in the metastatic (but not the healthy) group may be explained by greater tumor involvement secondary to higher cell injection concentrations. Untreated metastatic samples had higher DV/BV (16.25±2.54%) compared to all treatment groups (p<0.05) suggesting a benefit of treatment to bone quality. Focal and systemic cancer treatments were shown to effect load-to-failure and microdamage accumulation in healthy and osteolytic vertebrae. Developing a better understanding of how treatments effect bone quality and mechanical stability is critical for effective management of patients with spinal metastases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 67 - 67
11 Apr 2023
Britton M Schiavi J Vaughan T
Full Access

Type-2 Diabetic (T2D) patients experience up to a 3-fold increase in bone fracture risk[1]. Paradoxically, T2D-patients have a normal or increased bone mineral density when compared to non-diabetic patients. This implies that T2D has a deleterious effect on bone quality, whereby the intrinsic material properties of the bone matrix are altered. Creating clinical challenges as current diagnostic techniques are unable to accurately predict the fracture probability in T2D-patients. To date, the relationship between cyclic fatigue loading, mechanical properties and microdamage accumulation of T2D-bone tissue has not yet been examined and thus our objective is to investigate this relationship. Ethically approved femoral heads were obtained from patients, with (n=8) and without (n=8) T2D. To obtain the mechanical properties of the sample, one core underwent a monotonic compression test to 10% strain, the other core underwent a cyclic compression test at a normalized stress ratio between 0.0035mm/mm and 0.016mm/mm to a maximum strain of 3%. Microdamage was evaluated by staining the tissue with barium sulfate precipitate [2] and conducting microcomputed tomography scanning with a voxel size of 10μm. The monotonically tested T2D-group showed no statistical difference in mechanical properties to the non-T2D-group, even when normalised against BV/TV. There was also no difference in BV/TV. For the cyclic test, the T2D-group had a significantly higher initial modulus (p<0.01) and final modulus (p<0.05). There was no difference in microdamage accumulation. Previous population-level studies have found that T2D-patients have been shown to have an increased fracture risk when compared to non-T2D-patients. This research indicates that T2D does not impair the mechanical properties of trabecular bone from the femoral heads of T2D-patients, suggesting that other mechanisms may be responsible for the increased fracture risk seen in T2D-patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 93 - 93
1 Nov 2021
Schiavi J Remo A McNamara L Vaughan T
Full Access

Introduction and Objective. Bone remodelling is a continuous process whereby osteocytes regulate the activity of osteoblasts and osteoclasts to repair loading-induced microdamage. While many in vitro studies have established the role of paracrine factors (e.g., RANKL/OPG) and cellular pathways involved in bone homeostasis, these techniques are generally limited to two-dimensional cell culture, which neglects the role of the native extracellular matrix in maintaining the phenotype of osteocyte. Recently, ex vivo models have been used to understand cell physiology and mechanobiology in the presence of the native matrix. Such approaches could be applicable to study the mechanisms of bone repair, whilst also enabling exploration of biomechanical cues. However, to date an ex vivo model of bone remodelling in cortical bone has not been developed. In this study, the objective was to develop an ex vivo model where cortical bone was subjected to cyclic strains to study the remodelling of bone. Materials and Methods. Ex vivo model of bone remodelling induced by cyclic loading: At the day of culling, beam-shape bovine bone samples were cut and preserved in PBS + 5% Pen/Strep + 2 mM L-Glut overnight at 37°C. Cyclic strains were applied with a three-point bend system to induce damage with a regime at 16.66 mm/min for 5,000 cycles in sterile PBS in Evolve® bags (maximum strain 6%). A control group was cultured under static conditions. Metabolic activity: Alamar Blue assays were performed after 1 and 7 days of ex vivo culture for each group (Static, Loaded) and normalized to weight. Bone remodelling: ALP activity was assessed in the media at day 1 and 7. After 24 hours cell culture conditioned media (CM) was collected from each group and stored at −80°C. RAW264.7 cells were cultured with CM for 6 days, after which the samples were stained for TRAP, to determine osteoclastogenesis, and imaged. Histomorphometry: Samples were cultured with calcein for 3 days to label bone formation between day 4 and 7. Fluorescent images were captured at day 7. μCT scanning was performed at 3 μm resolution after labelling samples with BaSO. 4. precipitate to quantify bone damage. Results. Bone was sectioned and cultured to maintain live osteoblasts and osteocytes. CM that was obtained 24 hours after cyclic loading and added to RAW264.7 cells cultures, resulted in significantly increased osteoclastogenic potential compared to that from static samples (4.245±1.65% vs 0.88±0.48%, p<0.001). Calcein and HE staining indicated the presence of structures similar to bone remodelling cones in both groups after 7 days of culture. Also, 7 days post-loading, matrix microdamage in the stimulated area, detected with the BaSO. 4. precipitate, were not significantly increased under the load point in loaded samples (0.11±0.05% of bone volume), while at the support areas it was significantly higher (0.2387±0.06%, p<0.001) compared to the static (0.062±0.02%). Conclusions. This study demonstrates that (1) cyclic strains applied on ex vivo bovine cortical bone successfully induced remodelling as characterized by the formation of bone resorption cones, along with an increase of osteoclast formation, and (2) there was an induction of microdamage post loading as shown by the significant increases in microdamage labelled. This supports previous in vivo studies with an increase in osteoclastogenesis up to 7 days post loading. This is the first evidence of the development of an ex vivo model to study osteon remodelling that could be applied to study bone physiology and repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 109 - 109
11 Apr 2023
Amado I Hodgkinson T Mathavan N Murphy C Kennedy O
Full Access

Post-traumatic osteoarthritis (PTOA) is a subset of osteoarthritis, which occurs secondary to traumatic joint injury which is known to cause pathological changes to the osteochondral unit. Articular cartilage degradation is a primary hallmark of OA, and is normally associated with end-stage disease. However, subchondral bone marrow lesions are associated with joint injury, and may represent localized bone microdamage. Changes in the osteochondral unit have been traditionally studied using explant models, of which the femoral-head model is the most common. However, the bone damage caused during harvest can confound studies of microdamage. Thus, we used a novel patellar explant model to study osteochondral tissue dynamics and mechanistic changes in bone-cartilage crosstalk. Firstly, we characterized explants by comparing patella with femoral head models. Then, the patellar explants (n=269) were subjected to either mechanical or inflammatory stimulus. For mechanical stimulus 10% strain was applied at 0.5 and 1 Hz for 10 cycles. We also studied the responses of osteochondral tissues to 10ng/ml of TNF-α or IL-1β for 24hrs. In general the findings showed that patellar explant viability compared extremely well to the femoral head explant. Following IL-1β or TNF-α treatment, MMP13, significantly increased three days post exposure, furthermore we observed a decrease in sulfate glycoaminoglycan (sGAG) content. Bone morphometric analysis showed no significant changes. Contrastingly, mechanical stimulation resulted in a significant decrease sGAG particularly at 0.5Hz, where an increase in MMP13 release 24hrs post stimulation and an upregulation of bone and cartilage matrix degradation markers was observed. Furthermore, mechanical stimulus caused increases in TNF-α, MMP-8, VEGF expression. In summary, this study demonstrates that our novel patella explant model is an excellent system for studying bone-cartilage crosstalk, which responds well to both mechanical and inflammatory stimulus and is thus of great utility in the study of PTOA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 13 - 13
1 Nov 2018
Kennedy OD
Full Access

Osteoarthritis (OA) is the most common musculoskeletal disease in the EU and is characterized by cartilage degeneration, pain and restricted movement. Post-Traumatic OA (PTOA) is a specific disease subset that occurs subsequent to traumatic injury, such as ACL rupture and makes up 12% of the overall disease burden. Our current understanding PTOA is that initial injury affects multiple tissues, and many/all contribute to overall ‘joint failure.’ MRI scans show that subchondral bone marrow lesions (BMLs) are present in 80% of ACL rupture cases in the immediate aftermath of joint injury. Their presence indicates an acute consequence in subchondral bone. It has also been suggested that BMLs overlap with, or directly represent, bone microdamage. Microdamage is known to induce osteoclast-mediated remodelling in bone. Therefore, the inhibition of subchondral bone remodelling, particularly in the early phase post-injury, may be a candidate therapeutic approach for preventing PTOA. Finally, the contiguous link between subchondral bone and articular cartilage, can allow transport of small molecules across this boundary, this suggests that bone/cartilage crosstalk is likely to be a key factor in PTOA development after injury. This presentation will summarize recent advances in our understanding these phenomena in both animal and human studies


Bone & Joint Research
Vol. 6, Issue 10 | Pages 602 - 609
1 Oct 2017
Jin A Cobb J Hansen U Bhattacharya R Reinhard C Vo N Atwood R Li J Karunaratne A Wiles C Abel R

Objectives

Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the mechanical strength of bone treated with BP (oral alendronate), and correlate data with the microarchitecture and density of microcracks in comparison with untreated controls.

Methods

Trabecular bone from hip fracture patients treated with BP (n = 10) was compared with naïve fractured (n = 14) and non-fractured controls (n = 6). Trabecular cores were synchrotron scanned and micro-CT scanned for microstructural analysis, including quantification of bone volume fraction, microarchitecture and microcracks. The specimens were then mechanically tested in compression.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.