Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 5 - 5
8 Feb 2024
Ablett AD McCann C Feng T Macaskill V Oliver WM Keating JF
Full Access

This study compares outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual lag screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture. Technical factors associated with mechanical failure were also identified. All adult patients (>18yrs) with a subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Included patients underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022). Cox regression analysis was used to determine the risk of mechanical failure and technical predictors of failure. The study included 587 patients, 336 in the GN group (median age 82yrs, 73% female) and 251 in the IN group (median age 82yrs, 71% female). The IN group exhibited a higher prevalence of osteoporosis (p=0.002) and CKD□3 (p=0.007). There were no other baseline differences between groups. The risk of any mechanical failure was increased two-fold in the GN group (HR 2.51, p=0.020). Mechanical failure comprising screw cut-out (p=0.040), back-out (p=0.040) and nail breakage (p=0.51) was only observed in the GN group. The risk of peri-implant fracture was similar between the groups (HR 1.10, p=0.84). Technical predictors of mechanical included varus >5° for cut-out (HR 15.61, p=0.016), TAD>25mm for back-out (HR 9.41, p=0.020) and shortening >1cm for peri-implant fracture (HR 6.50, p=<0.001). Dual lag screw designs may reduce the risk of mechanical complications for patients with subtrochanteric femoral fractures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 30 - 30
1 May 2018
Sadekar V Moulder E Hadland Y Barron E Sharma H
Full Access

Introduction. Fracture and deformity after frame removal is a known risk in 9–14.5% of patients after circular frame treatment. The aims of this study were to assess the effectiveness of our staged protocol for frame removal and risk factors for the protocol failure. Methods and materials. We identified 299 consecutive patients who underwent circular frame fixation for fracture or deformity correction in our unit from our prospective database. All 247 patients who followed the staged frame removal protocol were included in this study. We reviewed the electronic clinical record and radiographs of each patient to record demographics, risk factors for treatment failure and outcome following frame removal. We defined failure of the protocol as a re-fracture or change in bony alignment within 12 weeks of frame removal. Results underwent statistical analysis using Chi square analysis. Results. Of the 247 patients, 196 were trauma patients, of which 56 were open fractures and 48 were elective cases. There were 92 Ilizarov frames and 155 hexapods. 93 patients were smokers. The protocol failed to prevent mechanical failure after frame removal in 10 patients, of which four had refracture and six had an increase in deformity. The average increase in deformity was 7.7 in the frontal plane and 3.8 in the lateral plane. We identified risk factors for mechanical failure in eight of the ten; four were smokers, two were on steroids and two had hypophosphataemic rickets. Of the ten patients, four were for elective indications, six for trauma. Two of the six trauma patients had been treated for open fractures. ‘The type of frame and smoking history showed no statistical association with mechanical failure. Four patients went to have another frame, five were managed with plaster and one patient refused further treatment. Conclusion. Our staged reloading protocol may delay frame removal however it is a simple and effective way to confirm the timing of frame removal


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 825 - 830
1 Jun 2013
Abram SGF Pollard TCB Andrade AJMD

The Gamma nail is frequently used in unstable peri-trochanteric hip fractures. We hypothesised that mechanical failure of the Gamma nail was associated with inadequate proximal three-point fixation. We identified a consecutive series of 299 Gamma nails implanted in 299 patients over a five-year period, 223 of whom fulfilled our inclusion criteria for investigation. The series included 61 men and 162 women with a mean age of 81 years (20 to 101). Their fractures were classified according to the Modified Evans’ classification and the quality of fracture reduction was graded. The technical adequacy of three points of proximal fixation was recorded from intra-operative fluoroscopic images, and technical inadequacy for each point was defined. All patients were followed to final follow-up and mechanical failures were identified. A multivariate statistical analysis was performed, adjusting for confounders. A total of 16 failures (7.2%) were identified. The position of the lag screw relative to the lateral cortex was the most important point of proximal fixation, and when inadequate the failure rate was 25.8% (eight of 31: odds ratio 7.5 (95% confidence interval 2.5 to 22.7), p < 0.001). Mechanical failure of the Gamma nail in peri-trochanteric femoral fractures is rare (< 1%) when three-point proximal fixation is achieved. However, when proximal fixation is inadequate, failure rates increase. The strongest predictor of failure is positioning the lateral end of the lag screw short of the lateral cortex. Adherence to simple technical points minimises the risk of fixation failure in this vulnerable patient group. Cite this article: Bone Joint J 2013;95-B:825–30


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 153 - 153
1 Sep 2012
De Biase P Capanna R Campanacci D Beltrami G Scoccianti G Piccioli A
Full Access

The reconstruction of lower limb defects after oncological reconstructions is still a problem in limb salvage surgery. Large bony defects need to be treated with sound and durable reconstructions. During recent decades, the life expectancy of patients affected with cancer has improved considerably because of advances in chemotherapy, immunotherapy, hormonal treatment and radiotherapy. This improvement requires greater reliability in the reconstructive procedure in order to avoid mechanical failure during prolonged survival of the patient. The author experience with modular megaprosthesis by Link (megasystem C) allowed us to present a rapid, effective and functional solution. From June 2001 to December 2007 225 patients have been operated with a megaprosthesis C for tumoral resection. The new megaprosthesis C by Link represents a wide-ranging system that can afford a large variety of reconstructions in the inferior limb, from very short replacement of 5 cm in proximal femur, to a total femur and proximal tibia replacement. Modularity is represented by 1 cm increase in length. The different options of cemented and not cemented stem may be used with intraoperative decision. In cemented stem a rough collar seals the osteotomy and prevents polyethylene debris from entering the femoral canal by inducing a scar tissue around the stem entrance (so-called purse-string effect). Moreover in patients with solitary lesions and very good prognosis an allograft-prosthesis composite can be performed with improved clinical results on walking and function. Of the 225 patients that underwent tumoral resection and reconstruction with a modular megaprosthesis approximately 43% (97 cases) were operated for metastatic disease. Among these cases 55 cases were proximal femoral recontructions, 39 cases were distal femoral reconstructions and 3 cases were proximal tibial reconstructions. All cases were performed with cemented stems. We experienced a 7% of postoperative infections, 2% of dislocations of proximal femoral prosthesis and 3% of mechanical failures. While infections and dislocation rates were in the average for this surgery, mechanical failures were relatively high. We should consider that in patients with relatively long resections and muscle deficiency the mechanical stress exerted on the prosthesis can explain this kind of mechanical failure. However the new design of morse tapers have annulled these problems


Bone & Joint Open
Vol. 5, Issue 3 | Pages 218 - 226
15 Mar 2024
Voigt JD Potter BK Souza J Forsberg J Melton D Hsu JR Wilke B

Aims

Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients.

Methods

Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 183 - 183
1 Sep 2012
Ruggieri P Pala E Henderson E Funovics P Hornicek F Windhager R Temple T Letson D Mercuri M
Full Access

Introduction. The current investigation includes a retrospective review of the experience of five Institutions with distal femur megaprostheses for tumor over a twenty year period, to analyze the incidence and etiology of failure, using a new classification system based upon the failure modes. Methods. Between 1974 and 2008, 2174 patients underwent primary limb preservation for a benign or malignant extremity tumor using a metallic megaprosthesis at five Institutions, 951 (43.7%) were distal femur replacements. Retrospective analysis of complications according to the Letson and Ruggieri Classification was performed and Kaplan-Meier curves of implant survival were defined. Segmental megaprosthetic reconstruction failures were categorized as mechanical and non-mechanical failures. Results. A total of 951 skeletally mature patients received a segmental endoprosthesis for the treatment of an oncologic condition. Overall 261 (27%) of the primary procedures were considered failures. There were 137 mechanical failures (14.4%): 12 (1.3%) Type 1 (soft tissue failure), 65 (6.8%) Type 2 (aseptic loosening), and 60 (6.3%) Type 3 (structural failure). Non-mechanical causes accounted for 124 failures (13%): 45 (4.7%)Type 4 (tumor progression) and 79 (8.3%) Type 5 (infection). The overall implant survival to all modes of failure was 77% at 10 years and 73% at 20 years. The implant survival to aseptic loosening was over 90% at 10 years. Conclusion. Most frequent cause of failure was infection followed by aseptic loosening and structural failure. The implant survival at long term was quite satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 969 - 971
1 Nov 1997
Baumgaertner MR Solberg BD

We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on antero-posterior and lateral views. This decreased from a mean of 25 mm in the control group to 20 mm in the study group (p = 0.0001). The number of mechanical failures by cut-out of the screw from the head decreased from 16 (8%) in the control group at a mean of 13 months to none in the study group at a mean of eight months (p = 0.0015). There were significantly fewer poor reductions in the study group. Our study confirms the importance of good surgical technique in the treatment of trochanteric fractures and supports the concept of the TAD as a clinically useful way of describing the position of the screw


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 158 - 158
1 Sep 2012
Funovics P Rois S Kotz R Dominkus M Windhager R
Full Access

Background. Modular endoprostheses today represent a standard treatment option in the management of musculoskeletal tumors of the lower extremities. Long-term results of these reconstructions, however, are often limited by the course of the underlying disease. We therefore report our experiences in cancer patients with megaprostheses of the lower limb after a minimum of 15 years. Materials and Methods. 62 patients, 34 men and 28 women, with a mean age of 26 years (median, 20; range, 6–83) were included in this investigation with a mean follow-up of 230 months (median, 228; range, 180–342). Endoprosthetic reconstructions of the proximal femur (11), the distal femur (28), the total femur (2) or the proximal tibia (21) were indicated for osteosarcoma (43), chondrosarcoma (5), malignant fibrous histiocytoma (3) or other tumors (11). All patients have received either a KMFTR (22) or a HMRS (40) modular prosthesis; 23 patients had a muscle flap, 14 had a fibular transposition osteotomy and 4 have received an artificial LARS ligament for soft-tissue reconstruction. Results. 7 patients (11.3%) died throughout the follow-up period, but none succumbed to primary disease. One patient (1.6%) developed a local recurrence after 31 months that was resected. Overall, 56 patients (90.3%) underwent revision of their prosthesis; 50 (80.7%) had multiple revisions up to a maximum of 12 operations (mean, 3 per patient). The median overall prosthetic survival to first revision was 40 months; the corresponding 5-, 10- and 15-year survival rates were 35.5%, 14.5% and 12.9%, respectively. 3 patients (5.4%) had an infection, 8 (14.3%) had a soft-tissue related failure, 30 (53.6%) had a mechanical or structural failure and 15 (26.8%) had an aseptic loosening. The 15-year survival rates of these respective endpoints were 87.1% for infection, 79.0% for soft-tissue related failure, 32.3% for mechanical or structural failure and 56.5% for aseptic loosening. 59 patients (95.2%) have retained their prosthesis; 2 patients (3.2%) underwent secondary amputation due to an irresolvable complication, another one (1.6%) for a second malignancy. Conclusion. Modular prosthetic reconstructions of the lower extremities have a high revision rate in the long-term, primarily due to mechanical failures. Given that patients survive their malignant disease the rate of secondary implant removal, however, tends to be low, providing satisfactory function and body integrity. Further advances in implant design, soft tissue management and infection prophylaxis are required to reduce revision rates


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 497 - 497
1 Sep 2012
Spalazzi J Baldini T Efird C Traub S Hiza E Cook S Rioux-Forker D Mccarty E
Full Access

Summary. Strong mechanical fixation is critical to the success of rotator cuff repairs. In this comparative study in cadaveric shoulders, single-tendon full-thickness supraspinatus tears were repaired using two different types of PEEK knotless suture anchors-ReelX STT (Stryker) and Opus Magnum PI (Arthrocare)-using a single-row technique in both instances. Cyclic testing was performed followed by loading until mechanical failure. No significant difference was observed in gap formation, measured as the distance between the supraspinatus tendon and bone at the repair site, during cyclic loading. However, the maximum load was statistically higher for repairs with the ReelX anchor. Purpose. The objective of this study was to compare the gap formation during cyclic loading and maximum repair strength of single-row full thickness supraspinatus repairs performed using two different types of PEEK knotless suture anchors in a cadaveric model. Methods. Nine matched pairs of cadaveric shoulders were used in this study. All soft tissue was removed except for the supraspinatus, and a full thickness tear was formed. Single-row repairs were performed with two anchors per repair using either the Opus Magnum PI (Arthrocare) or the ReelX STT (Stryker). The specimens were mounted to an Instron at 45° to simulate an anatomic direction of load, and fiducial markers were placed on the repair in anterior and posterior positions. A 10 N preload was applied and held for 60 seconds, and then the tendon was cycled from 10 N to 90 N at 0.25 Hz for 500 cycles, followed by load to failure at 1 mm/s. A video digitizing system was used to track the markers and measure gap formation during loading. Gap formation was calculated by subtracting the distance between the markers at 10 N preload from the maximum displacement at 5 and 500 cycles. Paired t-tests were used to compare the cyclic displacement and max load. Results. One specimen from each of two matched pairs (one from each anchor group) failed during cyclic loading, leaving seven matched pairs for analysis. No significant difference was found in cyclic displacement between the two groups in either anterior or posterior positions at 5 and 500 cycles. However, maximum load to failure was significantly greater for repairs performed with the ReelX STT anchors (289N ± 57N) as compared to the OPUS anchors (178N ± 36N), with a p=0.009. Conclusions. These results suggest that the anchor type chosen for cuff repairs may affect the overall stability of the repair. Achieving stable fixation is critical for promoting healing of the tendon back to bone and to the long-term success of the repair, and using anchors that provide stronger fixation may decrease the occurrence of post-surgical tears and instability. The ReelX STT anchor outperformed the Opus Magnum PI anchor in terms of supporting significantly higher loads before failure, potentially leading to stronger repairs clinically


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 442 - 442
1 Sep 2012
Field R Alazzawi S Field M Bardakos N Pinskerova V Freeman M
Full Access

Introduction. Femorotibial malalignment exceeding ±3° is a recognised contributor of early mechanical failure after total knee replacement (TKR). The angle between the mechanical and anatomical axes of the femur remains the best guide to restore alignment. We investigated where the femoral head lies relative to the pelvis and how its position varies with respect to recognised demographic and anatomic parameters. We have tested the hypothesis of the senior author that the position of the centre of the femoral head varies very little, and if its location can be identified, it could serve to outline the mechanical axis of the femur without the need for sophisticated imaging. Patients & Methods. The anteroposterior standing, plain pelvic radiographs of 150 patients with unilateral total hip replacements were retrospectively reviewed. All patients had Tönnis grade 0 or 1 arthritis on the non-operated hip joint. All radiographs were obtained according to a standardised protocol. Using the known diameter of the prosthetic head for calibration, the perpendicular distance from the centre of the femoral head of the non-operated hip to the centre of pubic symphysis was measured with use of TraumaCad software. Anatomic parameters, including, but not limited to, the diameter of the intact femoral head, were also measured. Demographic data (gender, age, height, weight) were retrieved from our database. Results. There were 72 men and 78 women with a mean age of 67.0 years. The mean distance of the centre of the femoral head to the pubic symphysis was 89.1 mm (standard deviation [SD], 5.8 mm). This distance was higher in men (mean, 90.5 mm; SD, 5.6 mm) than in women (mean, 87.7 mm; SD, 5.8 mm) (p=0.003). No statistically significant correlations between this distance and body-mass index or age (p=0.57 and p=0.28, respectively) were revealed. However, height was strongly correlated with this distance (r=0.52, p < 0.01), as was the diameter of the femoral head (r=0.61, p < 0.01). The latter was significantly larger in men than in women (p < 0.01). Conclusion. This is the first study to demonstrate that the position of the centre of the femoral head has very little variability, irrespective of patient age or body-mass index. As expected, it varies with patient's height and gender. Although statistically significant, the difference between genders is < 3 mm and can be explained by the smaller femoral head size of females. Our findings should prove useful during TKR surgery, as they facilitate intra-operative identification of the centre of the femoral head. Based on these results, simple trigonometry shows that if a surgeon measures 9 cm from the symphysis pubis, a line from this point to the centre of the knee will be within 2° and 2.2° of the true mechanical axis in 98% (i.e. ± 3 SD of the mean) of male and female patients, respectively


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1285 - 1291
1 Oct 2019
MacKenzie SA Ng RT Snowden G Powell-Bowns MFR Duckworth AD Scott CEH

Aims

Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical femoral fracture (AFFs). This study aims to report on a series of periprosthetic femoral fractures (PFFs) that otherwise meet the criteria for AFFs. Secondary aims were to identify predictors of periprosthetic atypical femoral fractures (PAFFs) and quantify the complications of treatment.

Patients and Methods

This was a retrospective case control study of consecutive patients with periprosthetic femoral fractures between 2007 and 2017. Two observers identified 16 PAFF cases (mean age 73.9 years (44 to 88), 14 female patients) and 17 typical periprosthetic fractures in patients on bisphosphonate therapy as controls (mean age 80.7 years (60 to 86, 13 female patients). Univariate and multivariate analysis was performed to identify predictors of PAFF. Management and complications were recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1248 - 1252
1 Sep 2016
White TO Bugler KE Appleton P Will† E McQueen MM Court-Brown CM

Aims

The fundamental concept of open reduction and internal fixation (ORIF) of ankle fractures has not changed appreciably since the 1960s and, whilst widely used, is associated with complications including wound dehiscence and infection, prominent hardware and failure. Closed reduction and intramedullary fixation (CRIF) using a fibular nail, wires or screws is biomechanically stronger, requires minimal incisions, and has low-profile hardware. We hypothesised that fibular nailing in the elderly would have similar functional outcomes to standard fixation, with a reduced rate of wound and hardware problems.

Patients and Methods

A total of 100 patients (25 men, 75 women) over the age of 65 years with unstable ankle fractures were randomised to undergo standard ORIF or fibular nailing (11 men and 39 women in the ORIF group, 14 men and 36 women in the fibular nail group). The mean age was 74 years (65 to 93) and all patients had at least one medical comorbidity. Complications, patient related outcome measures and cost-effectiveness were assessed over 12 months.


Bone & Joint Research
Vol. 5, Issue 10 | Pages 512 - 519
1 Oct 2016
Mills L Tsang J Hopper G Keenan G Simpson AHRW

Objectives

A successful outcome following treatment of nonunion requires the correct identification of all of the underlying cause(s) and addressing them appropriately. The aim of this study was to assess the distribution and frequency of causative factors in a consecutive cohort of nonunion patients in order to optimise the management strategy for individual patients presenting with nonunion.

Methods

Causes of the nonunion were divided into four categories: mechanical; infection; dead bone with a gap; and host. Prospective and retrospective data of 100 consecutive patients who had undergone surgery for long bone fracture nonunion were analysed.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives

The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator.

Materials and Methods

An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation.

In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group.

Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation.

The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used.

Cite this article: Bone Joint J 2015;97-B:398–404.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions.

There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection.

The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants.

We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1065 - 1070
1 Aug 2006
Appleton P Moran M Houshian S Robinson CM

Although the use of constrained cemented arthroplasty to treat distal femoral fractures in elderly patients has some practical advantages over the use of techniques of fixation, concerns as to a high rate of loosening after implantation of these prostheses has raised doubts about their use. We evaluated the results of hinged total knee replacement in the treatment of 54 fractures in 52 patients with a mean age of 82 years (55 to 98), who were socially dependent and poorly mobile.

Within the first year after implantation 22 of the 54 patients had died, six had undergone a further operation and two required a revision of the prosthesis. The subsequent rate of further surgery and revision was low.

A constrained knee prosthesis offers a useful alternative treatment to internal fixation in selected elderly patients with these fractures, and has a high probability of surviving as long as the patient into whom it has been implanted.