The radiological and MRI appearances of 24 knees with patellar tendonitis resistant to conservative therapy were analysed to identify the characteristic MRI appearance and to determine if the patellar morphology was abnormal. A significant thickening of the tendon was found in all cases; this was a more reliable diagnostic feature than a high signal within the superior posterior and central aspect of the tendon at its proximal attachment The site of the lesion shown by MRI is more compatible with impingement of the inferior pole of the patella against the patellar tendon than a stress overload of the tendon. There were no significant differences in the length of the patella, inferior pole or length of the articular surface when the patellar morphology was compared with that of a matched control group.
The purpose of this study was to determine the accuracy of MRI scan for the detection of meniscal pathology in our unit. There are published data which show that both sensitivity and specificity can approach 90% when compared to arthroscopic findings. We retrospectively analysed a single surgeon series of 240 scopes for all indications The arthroscopic reports included an outline diagram of the meniscus upon which the surgeon recorded operative findings. 112 of these patients had also had recent MRI. We looked at whether the MRI report showed a tear, and this was graded Y/N. The arthroscopic report was graded for tear: Y/N. 66 patients had a positive scan. 64 of these were found to have a tear at surgery. 37 scans were reported as “no tear”, of which 4 were found to have a tear at surgery. Nine scans were not easy to classify as they were descriptive. In our series of 112 knees, MRI was 90.5% sensitive, 89.5% specific and 90.1% accurate. When a definite diagnosis of “tear”, or “no tear” was made at scan, there were two false positives and four false negatives. False positives may be unnecessarily exposed to the risks of surgery. Patients with negative scans had a mean delay to surgery of 33 weeks compared to 18 weeks for patients with positive scans. False negatives may wait longer for their surgery. Two of the false negative scans clearly showed meniscus tears which were missed by the reporting radiographer. In our series the scan itself was more accurate than the reporting. It is important to have an experienced musculoskeletal radiologist to minimise the number of missed tears. It is also important for surgeon to check the scan as well as the report.
A feasibility study of the use of an MRI based patient specific knee arthroplasty system within the NHS. Introducing new technologies within a public funded health system can be challenging. We assess the use and potential benefit of customised jigs for knee arthroplasty. Outcomes assessed were safety and accuracy of implantation. Eight knee replacements using custom jigs were compared to 11 conventionally instrumented replacements matched to surgeon and operative day. Parameters measured include tourniquet time; drain output; hospital stay; adjusted change in haemoglobin; complications; and component position on post-operative long-leg alignment films None of the parameters observed demonstrated a statistically significant difference from the conventional arthroplasty group. No complications were seen in either group. No significant differences were seen in alignment. Our early experiences show that this technology appears safe and allows accurate implantation of the prosthesis. There was a trend for decreased stay and blood loss. The health economic benefits of navigational arthroplasty have been demonstrated in other studies and come from the lack of instrumentation of the intramedullary canal. MRI based patient specific instrumentation is considered technically easier and more convenient than intra-operative navigation. A larger study is planned to assess the health economic implications of adopting this new technology.
Abstract. Introduction. Previous research has demonstrated no clinically significant benefit of arthroscopic meniscectomy in patients with a meniscal tear, however, patients included in these studies would not meet current treatment recommendations. Prior to further randomised controlled trials (RCTs) research is needed to understand a younger population in more detail. Aim. To describe the baseline characteristics of patients with a meniscal tear and explore any association between baseline characteristics and outcome. Methodology. A prospective, national multicentre cohort study was performed recruiting patients aged 18 to 55 presenting to secondary care. MRI analysis of arthritis was performed using Whole Organ
Patient specific cutting guides generated by
preoperative
The Oswestry-Bristol Classification (OBC) was recently described as an MRI-based classification tool for the femoral trochlear. The authors demonstrated better inter- and intraobserver agreement compared to the Dejour classification. As the OBC could potentially provide a very useful MRI-based grading system for trochlear dysplasia, it was the aim to determine the inter- and intraobserver reliability of the classification system from the perspective of the non-founder. Two orthopaedic surgeons independently assessed 50 MRI scans for trochlear dysplasia and classified each according to the OBC. Both observers repeated the assessments after six weeks. The inter- and intraobserver agreement was determined using Cohen’s kappa statistic and S-statistic nominal and linear weights.Aims
Methods