Summary. Biomechanically, a 2° screw deviation from the nominal axis in the PFLCP leads to significantly earlier implant failure. Screw deviation relies on a technical error on insertion, but in our opinion cannot be controlled intraoperatively with the existing instrumentation devices. Background. Several cases of clinical failure have been reported for the Proximal Femoral
The locking compression plate (LCP), which is inserted in a minimal invasive technique, utilizing an anterolateral approach to the proximal humerus, allows adequate reduction and fixation, while minimizing the risk for complications derived from extensive exposure and poor fixation.
The patients were followed closely beginning 2 weeks post-operatively and afterwards on a bi-monthly basis. Immediate complications, radiographic and functional outcome were noted.
Functional outcome was good, patients regained 120°±25 of flexion, 112°±27 of abduction and 17°±8 of external rotation.
Introduction: Previously, we noticed loss of initial reduction with conventional palmar plate osteosynthesis for dorsally displaced distal radius fractures.
To investigate the differences of open reduction and internal
fixation (ORIF) of complex AO Type C distal radius fractures between
two different models of a single implant type. A total of 136 patients who received either a 2.4 mm (n = 61)
or 3.5 mm (n = 75) distal radius locking compression plate (LCP
DR) using a volar approach were followed over two years. The main
outcome measurements included motion, grip strength, pain, and the
scores of Gartland and Werley, the Short-Form 36 (SF-36) and the
Disabilities of the Arm, Shoulder, and Hand (DASH). Differences
between the treatment groups were evaluated using regression analysis
and the likelihood ratio test with significance based on the Bonferroni
corrected p-value of <
0.003.Objectives
Methods
Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment
Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates. Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle
Introduction and Objective. Plating of geriatric distal femoral fractures with
Introduction and Objective. Distal femoral fractures are commonly treated with a straight plate fixed to the lateral aspects of both proximal and distal fragments. However, the lateral approach may not always be desirable due to persisting soft-tissue or additional vascular injury necessitating a medial approach. These problems may be overcome by pre-contouring the plate in helically shaped fashion, allowing its distal part to be fixed to the medial aspect of the femoral condyle. The objective of this study was to investigate the biomechanical competence of medial femoral helical plating versus conventional straight lateral plating in an artificial distal femoral fracture model. Materials and Methods. Twelve left artificial femora were instrumented with a 15-hole
Introduction and Aims: Locking plates represent a major change in the way we stabilise fractures. The distal radius
New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was. to compare the stiffness and strength of a contoured
Aim: The pylon tibial fractures are a challenge for the orthopaedic surgeons. The purpose of this study was comparative analysis of different surgical methods of the pylon fractures. Methods: From 1994 to 2003 143 pylon fractures were treated. There were 87 men and 56 women from 15 to 74 years old. In 45 cases we used only external fixation (Ilizarov apparatus), in 29 open reduction and screw fixation was combined with external fixations. Sixty eight fractures were treated by ORIF according AO principles. In 51 cases “clover leaf” and 1/3 tubular plates were used, in 18 cases stable fixation was realized by LCP-plates. Follow-up results were analyzed through 9 and 12 months. Results: The good and excellent results (no pain, deformities and good function) were received in 72,7% patients, the satisfactory results – at 23,8 % cases. In 9 patients the superficial and in 4 the deep wound infection took place. The best results are received in cases of
Introduction: Standard treatment for distal tibia fractures is the fixation with locking compression plates. Locking plate fixation has revolutionized fracture treatment in the last decade and may be ideally suited for a bridging plate osteosynthesis. This technique allows some controlled axial fracture motion, what essential for secondary bone healing is. A disadvantage of the locking plate technique seems to be an unsymmetrical micro motion along the fracture gap. The micromotion at the far cortex side is much larger than at the near cortex side (near the plate). It is supposed to be that the fracture movement on the near cortex is too small. To increase the motion at the near cortex side a new kind of screws has been developed. In this study we examined the micromotion using normal locking head screws versus the new dynamic locking head screws. Materials and Methods: A simplified fracture model was created by connecting 2 plastic cylinders (POM C, EModul: 3.1GPa) with a standard 11-holes
Background: There is no consensus on the best treatment of complex intraarticular fractures and high energy diaphyseal fractures of the long bones. The
Introduction.
Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures. The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.Aims
Methods
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
Fracture-related infection (FRI) is commonly classified based on the time of onset of symptoms. Early infections (< two weeks) are treated with debridement, antibiotics, and implant retention (DAIR). For late infections (> ten weeks), guidelines recommend implant removal due to tolerant biofilms. For delayed infections (two to ten weeks), recommendations are unclear. In this study we compared infection clearance and bone healing in early and delayed FRI treated with DAIR in a rabbit model.
Aims
Methods
The aim of this study was to compare outcomes of guided growth and varus osteotomy in treating Kalamchi type II avascular necrosis (AVN) after open reduction and Pemberton acetabuloplasty for developmental dysplasia of the hip (DDH). This retrospective study reviewed patients undergoing guided growth or varus osteotomy for Kalamchi type II AVN between September 2009 and January 2019. All children who had undergone open reduction and Pemberton acetabuloplasty for DDH with a minimum two-year follow-up were enrolled in the study. Demographic and radiological data, which included the head-shaft angle (HSA), neck-shaft angle (NSA), articulotrochanteric distance (ATD), Sharp angle (SA), and lateral centre-edge angle (LCEA) at baseline, two years, and at the extended follow-up, were compared. Revision rates were evaluated. Clinical outcomes using the Harris Hip Score were assessed two years postoperatively.Aims
Methods