Introduction. The primary purpose of Total Hip Arthroplasty (THA), aside from pain relief, is to restore hip biomechanics such that the patient experiences no discernible functional deficit, while also providing an environment conducive to implant longevity. Key factors in determining a successful THA include achieving the desired pre-operative femoral offset and leg length, as well as the restoration of range of motion (ROM). Minor leg length discrepancies (LLDs), less than a centimetre, are common after THA and usually well tolerated. However, in some patients, even these small discrepancies are a source of dissatisfaction. More significant discrepancies can be a risk factor for more serious concerns such as nerve injury, abnormal gait and chronic pain. The level of the femoral neck osteotomy is a critical step in reproducing a planned femoral stem position. Frequently the femoral osteotomy is too high and can lead to an increase in leg length and varus stem positioning. If the desired implant positions are identified from preoperative 3D templating, a planned femoral osteotomy can be used as a reference to recreate the correct leg length and offset. The aim of this study was assess the accuracy of a 3D printed patient-specific guide for delivering a pre-planned femoral neck osteotomy. Methodology. A consecutive series of 33 patients, from two surgeons at a single institution, were sent for Trinity OPS pre-operative planning (Optimized Ortho, Australia). Trinity OPS is a pre-operative, dynamic, patient-specific modelling system for acetabular and femoral implant positioning. The system requires a pre-operative CT scan which allows patient specific implant sizing as well as positioning. Once the preoperative implant positioning plan was confirmed by the surgeon, a patient-specific guide was designed and printed to enable the planned
As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach. A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).Aims
Methods
Introduction. Restoration of mechanical axis is one of the main aims during Total Knee Arthroplasty (TKA) surgery. Treatment of osteoarthritis (OA) of the knee with extra-articular deformity either in femur or in tibia poses a technical challenge in achieving this aim. Insufficient correction of axis is associated with poor clinical outcome of total knee arthroplasty (TKA). Extra-articular deformity can either be addressed with compensatory intra-articular bone resection at the time of TKA or correctional osteotomy prior to or at the time of TKA. Patients & Methods & Results. We present our experience of treating 7 patients with knee arthritis (9 knees) and significant extra-articular deformity. Two patients had OA knee with severe valgus deformity in tibia from recurrent stress fractures. One was treated with one-stage corrective osteotomy and long stem modular TKA. The other had deformity correction with two
Double
Background. Dislocation is a common complication after proximal and total femur prosthesis reconstruction for primary bone sarcoma patients. Expandable prosthesis in children puts an additional challenge due to the lengthening process. Hip stability is impaired due to multiple factors: Resection of the hip stabilizers as part of the sarcoma resection: forces acts on the hip during the lengthening; and mismatch of native growing acetabulum to the metal femoral head. Surgical solutions described in literature are various with reported low rates of success. Objective. Assess a novel 3D surgical planning technology by use of 3D models (computerized and physical), 3D planning, and Patient Specific Instruments (PSI) in supporting correction of young children suffering from hip instability after expandable prosthesis reconstruction following proximal femur resection. This innovative technology creates a new dimension of visualization and customization, and could improve understanding of this complex problem and facilitate the surgical decision making and procedure. Method. Two children, both patients with Ewing Sarcoma of the left proximal femur stage-IIB, ages 3/5 years at diagnosis, were treated with conventional chemotherapy followed by proximal femur resection. Both were reconstructed with expandable prosthesis (one at resection and other 4 years after resection). Hip migration developed gradually during lengthening process in the 24m follow up period. 3D software (Mimics, Materialise, Belgium) were used to make computerized 3D models of patients' pelvises. These were used to 3D print 1:1 physical models. Custom 3D planning software (MSk Lab, Imperial College London) allowed surgeons visualizing the anatomical status and assess of problem severity. Thereafter, osteotomies planes and the desired position of acetabular roof after reduction of hip joint were planned by the surgeons. These plans were used to generate 3D printed PSIs to guide the osteotomies during shelf and triple osteotomy surgeries. Accuracy of planning and PSIs were verified with fluoroscopy and post-op X-rays, by comparing cutting planes and post-op position of the acetabulum. Results. Surgeons reported excellent experience with the 3D models (computerized and physical). It helped them in the decision process with an improved understanding of the relationship between prosthesis head and acetabulum, a clear view of the osteophytes and bone formation surrounding the pseudoacetabulum, and osteophytes inside the native acetabulum. These osteophytes were not immediately visible on 2D CT imaging slices. Surgeons reported a good fit and PSIs' simplicity of use. The hip stability was satisfactory during surgery and in the immediate post-op period. X-ray showed a good and centered position of the hip and good
Osteotomies for valgus deformity are much less frequent than those for varus deformity as evidenced by published series which are, on one hand, less numerous and on the other hand, based on far fewer cases. For genu varum deformity, it has been proved that navigation allows to reach easier the preoperative correction goal. Our hypothesis was that navigation for genu valgum could be as accurate as for genu varum deformity. The aim of this paper was to present the mid-term results of 29 computer-assisted osteotomies for genu valgum deformity performed between September 2001 and March 2013. The series was composed of 27 patients (29 knees), 20 females and 7 males, aged from 15 to 63 years (mean age: 42.4+/−14.3 years). The preoperative functional status was evaluated according to the Lyshölm-Tegner score. The mean score was of 64+/−20.5 points (18–100). The stages of osteoarthritis were evaluated according to modified Ahlbäck's criteria. We operated on 12 stage 1, 9 stage 2, 5 stage 3 and 1 stage 4. 2 female patients had no osteoarthritis but a particularly unesthetic deformity (of which one was related to an overcorrected tibial osteotomy). The pre and postoperative HKA angle was measured according to Ramadier's protocol. We measured also the medial tibial mechanical angle (MTMA) and the medial femoral mechanical angle (MFMA). The mean preoperative HKA angle was 189.3°+/−3.9° (181° to 198°); the mean MFMA was 97.2° +/− 2.6° (93° to 105°) and the mean MTMA was 90.1° +/− 2.8° (86° to 95°). The goal of the osteotomies was to obtain an HKA angle of 179° +/− 2° and a MTMA of 90°+/2° in order to avoid an oblique joint line. We performed 24 femoral osteotomies (14 medial opening wedge and 10 lateral closing wedge) and 5 double osteotomies (medial tibial closing wedge + lateral opening wedge osteotomy). The functional results were evaluated according to Lyshölm-Tegner, IKS and KOO Scores, which were obtained after revision or telephone call. We did not find any complication except a transient paralysis of the common fibular nerve. 23 patients (4 lost to follow-up) were reviewed at a mean follow-up of 50.9+/−38.8 months (6–144). The mean Lyshölm-Tegner score was 92.9+/−4 points (86–100), the mean KOO score 89.7+/−9.3 (68–100), the mean IKS ≪knee≫ score 88.7 +/−11.4 points (60 à 100) and the mean ≪function≫ score 90.6 +/−13.3 points (55–100). 22 of the 23 reviewed patients (25 knees) were very satisfied or satisfied of the result. Regarding the radiological results, the mean HKA angle was of 180.1°+/−1.9° (176° to 185°), the mean MFMA of 90.7°+/−2.5° (86°-95°) and the mean MTMA of 89.1°+/−1.9° (86°-92°). The preoperative goal was reached in 86.2% (25/29) of the cases for HKA angle and in 100% of the cases for MTMA when performing double
Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods
Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest. The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion.
We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.
Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.