header advert
Results 1 - 17 of 17
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 41 - 41
1 Aug 2013
Ecker T Steppacher S Haimerl M Murphy S
Full Access

Introduction. Correct postoperative leg length restoration is among the most important goals of hip arthroplasty. Therefore, we developed, validated and clinically applied a novel software algorithm based on surgical navigation, which allows the surgeon to restore a defined femur position without establishing a femoral coordinate system or the hip joint center and measure the leg length accurately and simply. Material and Methods. This new leg length algorithm was used in 154 hips (145 patients) that underwent CT-based computer-assisted THA (VectorVision Build 274 prototype; BrainLAB AG, Helmstetten, Germany) with a tissue preserving superior capsulotomy. Intraoperatively, a pelvic and a femoral dynamic reference bases (DRB) were applied and the anterior pelvic plane (APP) was set as the pelvic coordinate system. Then, the hip joint was put in a neutral position and this position, and the relative position of the femoral DRB relative to the pelvic DRB, was captured and stored by the navigation system. After implantation of the prosthesis the same above described femoral position with the same amplitude of flexion/extension, abduction/adduction and rotation was restored. Now, any resulting difference was due to linear changes. Validation of this new algorithm was performed by comparing the navigated results to measurements from calibrated antero-posterior pre- and postoperative radiographs. The radiographic results were compared to the mean leg length change measured with the navigation system. Results. No significant difference was found between radiographic leg length change and the results from the navigation system (p=0.658). The mean difference between the radiographic results and the results from the navigation system was −0.5 (1–8 mm (range, −5–4 mm). The mean registration accuracy of the navigation system was 2.04 (0.58 mm (range, 0.70–3.00 mm). Discussion. This novel tool has the potential to increase the accuracy and consistency of leg-length change measurement during hip arthroplasty. Improved methods of measuring leg length change during surgery are even more critical now, when smaller incisions are being used, because traditional mechanical measurement methods are potentially even more unreliable than they are when larger exposures are used. This current method of measuring leg length change eliminates the need to calculate the center of rotation of the arthritic hip joint, which is often not accurately possible, and eliminates the need to establish a femoral coordinate system, which can be time consuming and frustrating. Besides registration accuracy, validation with plain radiographs is another potential source of error. Nonetheless, there was a substantial agreement between the radiographic results and the results from the navigation system. This novel computer-assisted method represents an accurate and simple tool for intraoperative leg length measurement


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 49 - 49
1 Apr 2022
Birkenhead P Birkenhead P
Full Access

Introduction

Leg length discrepancy (LLD) is a common sequalae of limb reconstruction procedures. The subsequent biomechanical compensation can be directly linked to degenerative arthritis, lower back pain, scoliosis and functional impairment. It becomes particularly problematic when >2cm, established as a clinical standard. This two-arm experimental study assesses how reliable an iPhone application is in the measurement of LLD at different distances in control and LLD patients.

Materials and Methods

42 participants were included in the study, divided evenly into 21 control and 21 LLD patients. A standardised measurement technique was used to obtain TMM and iPhone application measurements, taken at a distance of 0.25m, 0.50m and 0.75m.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 16 - 16
1 Oct 2015
Memarzadeh A Arvinte D Sood M
Full Access

Introduction. Restoration of anatomy is essential in total hip arthroplasty (THA) to optimize function and stability. Leg-length discrepancy of ≥10mm is poorly tolerated and can be the subject of litigation. We use a multimodal protocol to optimize soft tissue balancing which involves pre- operative templating, leg-length measurement supine and after positioning, use of an intra-operative leg-length and offset measurement device and implants with standard and high-offset options. Methods. Radiological leg-length and femoral offset were measured in a consecutive series of 100 patients who had THA for unilateral arthritis by an independent observer pre- and post-operatively using validated methods and the contra lateral hip as a control. Results. Leg-length was restored to within 5mm of the contra lateral side in 80% of patients (mean 1.5mm (95% CI −5.7 to +8.7)). Offset was restored to within 5mm in 90% of patients (mean 0.6mm (95% CI −5.6 to +6.8)). Conclusion. We have narrowed the range of discrepancy compared to other studies. Intra-operative measurement of offset is difficult unless a specific device is utilized. We have restored the femoral offset accurately within a narrow range of the mean. We recommend a similar protocol to ensure restoration of leg-length and offset and maximize function and patient satisfaction


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 6 - 6
1 May 2021
Chatterton BD Kuiper J Williams DP
Full Access

Introduction. Circumferential periosteal release is a rarely reported procedure for paediatric limb lengthening. The technique involves circumferential excision of a strip of periosteum from the metaphysis of the distal femur, tibia and fibula. This study aims to determine the mid to long-term effectiveness of this technique. Materials and Methods. A retrospective case series was performed of all patients undergoing circumferential periosteal release of the distal femur and/or tibia between 2006 and 2017. Data collected included demographics, surgical indication, post-operative limb-lengths and complications. Data collection was stopped if a further procedure was performed that may affect limb-length (except a further release). Leg-length discrepancies were calculated as absolute values and as percentages of the longer limb-length. Final absolute and percentage discrepancies were compared to initial discrepancies using a paired t-test. Results. Eighteen patients (11 males) were identified, who underwent 25 procedures. The mean age at first surgery was 5.83 (SD 3.49). The commonest indication was congenital limb deficiency (13 patients). In 23 procedures the periosteum was released in two limb segments (distal femur and distal tibia), whereas in two patients it was released in a single limb segment. Five patients underwent repeat periosteal release, and one patient had three periosteal releases. Mean follow-up was 63.1 months (SD 33.9). Fifteen patients had sufficient data for statistical analysis. The mean initial absolute discrepancy was 2.01cm (SD 1.13), and the mean initial percentage discrepancy was 4.09% (SD 2.76). The mean final absolute discrepancy was 1.00cm (SD 1.62), and the mean percentage final discrepancy was 1.37% (SD 2.42). The mean reduction in absolute discrepancy was 0.52 cm (95%CI −0.04–1.08; p=0.068, paired t-test), and the mean reduction in percentage discrepancy was 2.00% (95% CI 1.02–2.98, p=<0.001 paired t-test). In five patients the operated limb overgrew the shorter limb. Conclusions. Circumferential periosteal release produces a modest decrease in both absolute and percentage limb-length discrepancy, although the outcome is variable and some patients may experience overgrowth of the operated limb


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 27 - 27
1 Feb 2021
Domb B Maldonado D Chen J Kyin C Bheem R Shapira J Rosinsky P Karom J
Full Access

Introduction. Primary robotic-arm assisted total hip arthroplasty (THA) yields more accurate and reproducible acetabular cup placement, nonetheless, data is scarce in terms of outcomes. The purpose of the present study was to report on patient-reported outcomes (PROMs) in a large group of patients who underwent robotic-arm assisted THA. The authors hypothesized that (1) patients who underwent robotic-arm assisted primary THA would achieve favorable and significant improvement in PROMs, (2) an accurate and reproducible acetabular cup placement with respect to the defined SafeZones would be obtained, and (3) a low rate of THA dislocation would be observed. Methods. Prospectively collected data were retrospectively reviewed between April 2012 to May 2017. Primary THA using Mako Robotic-Arm [Mako Surgical Corp. (Stryker), Fort Lauderdale, FL, USA] with minimum two-year follow-up for the Harris Hip Score (HHS) and the Forgotten Joint Score-12 (FJS-12) were included. Exclusion criteria were: bodymass index (BMI) > 40 kg/m2, age < 21-year old, worker's compensation, or unwilling to participate. Visual analog scale (VAS) for pain and patient satisfaction were obtained. Intraoperative measurements for leg-length, global offset, acetabular inclination and version were documented. Results. 501 hips were included (57.29% females), follow-up was 43.99 ± 15.59 months. Average age was 58.70 ± 9.41 years, and the BMI was 28.41 ± 4.55 kg/m2. The group reported HHS of 90.87 ± 13.45, FJS-12 of 79.97 ± 25.87, VAS of 1.20 ± 2.06, and patient satisfaction of 8.85 ± 2.08. Intraoperative values for acetabular inclination and version were 40.0° ± 2.2 ° and 20.5° ± 2.4° respectively. Revision due to instability was 0.2%. Conclusions. Patients who received primary robotic-arm assisted THA reported excellent results at 44-month follow-up for multiple PROMs. Consistency in acetabular cup placement accuracy was achieved in regard to the Lewinnek and Callanan safe-zones


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 105 - 105
1 Apr 2019
Widmer KH Ottersbach A Schroeder-Boersch H
Full Access

Introduction. Computer navigation is a highly sophisticated tool in orthopedic surgery for component placement in total hip arthroplasty (THA). A number of recommendations have been published. Although Lewinnek's safe-zone is the best-known among these its significance is questioned in recent years since it addresses the acetabular socket only ignoring the femoral stem. Modern target definitions consider both socket and stem and provide well-defined recommendations for complementary component positioning. We present a new small-sized hand-held imageless navigation system that implies these targets and supports the surgeon in realizing the concept of combined anteversion and combined Target-Zone (cTarget- Zone) in THA and to control leg length and offset without altering the standard surgical work-flow and we report initial results. Methods. The targets for positioning the components of a total hip as expressed by radiographic cup inclination (cRI) and anteversion (cRA), stem antetorsion (sAT) and neck-to-shaft angle (sNSA) are determined for a specific prosthesis system using a computerized 3D-model. The optimizing goal is maximizing the size of the cSafe-Zone providing the largest target zone for an impingement-free prosthetic range of motion (pROM) in order to minimize the risk for dislocation in physiologic and combined movements. Independent parameters like head size, head-to-neck ration and also component orientations like cRI, cRA, sAT and sNSA were varied systematically and the optimal cSafe-Zone was computed in semi-automated batch runs. These optimized prosthesis-specific results were introduced into the software of the hand-held navigation system. This system measures leg length, offset, acetabular and femoral head centers intraoperatively. Results. In contrast to Lewinnek the outline of our cSafe-Zone is not rectangular but polygonal. Its size shows prosthesis-specific maxima. The largest zones are found for optimal sNSA values at 126° +/−4°, optimal ranges for cRI depend on head size and range from 44° to 36°, best sAT range from 10° to 18°, cRA from 18° to 25°. There is a prosthesis- specific linear correlation between sAT and cRA that denotes the combined anteversion. The target value for combined anteversion is not dependent on pelvic tilt but on sNSA. The hand-held navigation system displays all these orienting parameters as well as leg-length and offsets. Furthermore, it supports a virtual reduction work-flow thus accelerating surgery. All these information provide important decision-making details for the surgeon intraoperatively in real-time for augmented quality. Conclusion. The combined Target-Zone provides the basis for patient- and implant-specific control of prosthesis implantation. It includes all important positioning parameters of both total hip components and such gives well-defined individual recommendations for the targets. The new hand-held navigation system (Naviswiss) provides a smart way to direct and control the total hip implantation according to the best combined orientation considering also the concept of combined Safe-Zone. Such it prevents outliers, provides better safety and documents the surgical workflow and the final result of the surgery


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 79 - 79
1 Feb 2017
Cooper J Koenig J Hepinstall M Rodriguez J
Full Access

Introduction. Prosthetic replacement remains the treatment of choice for displaced femoral neck fractures in the elderly population, with recent literature demonstrating significant functional benefits of total hip arthroplasty (THA) over hemiarthroplasty. Yet the fracture population also has historically high rates of early postoperative instability when treated with THA. The direct anterior approach (DAA) may offer the potential to decrease the risk of postoperative instability in this high-risk population by maintaining posterior anatomic structures. The addition of intraoperative fluoroscopy can improve precision in component placement and overcome limitations on preoperative planning due to poor preoperative radiographs performed in the emergency setting. Methods. We retrospectively reviewed clinical and radiographic outcomes of 113 consecutive patients with displaced femoral neck fractures treated by two surgeons over a five-year period. All underwent surgery via the DAA using fluoroscopic guidance, and were allowed immediate postoperative weight bearing without any hip precautions or restrictions. Charts were reviewed for relevant complications, while radiographs were reviewed for component positioning, sizing, and leg length discrepancy. Mean follow-up was 8.9 months. Results. Mean age was 79.3 years (range, 42 to 101), 73% of patients were women, and mean BMI was 22.6 kg/m. 2. Ninety patients (80%) received THA while 23 (20%) received unipolar or bipolar hemiarthroplasty. Mean acetabular anteversion was 15.0 degrees (range, 4 to 24) and mean abduction was 39.2 degrees (range, 27 to 51) with 95% of acetabular components in the combined safe zone as described by Lewinnek. Mean radiographic leg-length difference was +2.2 mm (range, −4.9 to +8.8mm). There was no femoral stem subsidence of more than 2mm. Only one patient (0.9%) dislocated postoperatively, who was eventually constrained for recurrent posterior instability 3 months following surgery. Delayed wound healing (6.1%) was the most common postoperative complication. Conclusions. The direct anterior approach allows a safe, effective, and reproducible approach for treatment of displaced femoral neck fractures, with very low rate of early postoperative instability compared to historical controls. The use of intraoperative fluoroscopy allows excellent component positioning, sizing, and restoration of leg length in spite of inconsistent preoperative radiographs


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 7 - 7
1 Mar 2014
Jawed A El Bakoury A Williams M
Full Access

There has been a trend towards operative management of pelvic injuries. Posterior pelvic integrity is more important for functional recovery. Percutaneous iliosacral screw fixation is being increasingly preferred for posterior pelvic stabilisation. Outcome reporting for this procedure remains inconsistent and un-standardised. Retrospectively, all percutaneous iliosacral screw fixations done at this institute during a 5-year period (2008–2012) were reviewed. 28 patients, who had had at least 12 months follow-up, were contacted and clinical scoring was done by postal correspondence. Radiographs were measured for displacements and leg-length discrepancy. Possible factorial associations and correlations were investigated. Mean Majeed score was 83 (median 87), mean EQ-Visual Analog Score (EQ-VAS) was 75.5 (median 80) and the two scores were correlated with statistical significance. Tile AO type C injuries produced worse outcomes and patients who'd anterior pelvic fixation did better. Our results show high patient-reported outcomes, excellent radiologically measured reductions and unions. The incidence of complications is very low. There is a significant correlation between the EQ-VAS arm of the EQ5D instrument and the Majeed score in this patient population. Incidence of non-pelvic surgical procedures in these patients was significantly associated with worse outcomes. Leg length discrepancies appeared to increase after patients were fully weight bearing


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 67 - 67
1 Jan 2016
Thomas A Murphy S Kowal JH
Full Access

Introduction. Studies show that cup malpositioning using conventional techniques occurs in 50 to 74% of cases defined. Assessment of the utility of improved methods of placing acetabular components depends upon the accuracy of the method of measuring component positioning postoperatively. The current study reports on our preliminary experience assessing the accuracy of EOS images and application specific software to assess cup orientation as compared to CT. Methods. Eighteen patients with eighteen unilateral THA had pre-operative EOS images were obtained for preoperative assessment of leg-length difference and standing pelvic tilt. All of these patients also had preoperative CT imaging for surgical navigation of cup placement. This allows us to compare cup orientation as measured by CT to cup orientation as measured using the EOS images. Application specific software modules were developed to measure cup orientation using both CT and EOS images (HipSextant Research Application 1.0.13 Surgical Planning Associates Inc., Boston, Massachusetts). Using CT, cup orientation was determined by identifying Anterior Pelvic Plane coordinate system landmarks on a 3D surface model. A multiplanar reconstruction module allows for creation of a plane parallel with the opening plane of the acetabulum and subsequent calculation of plane orientation in the AP Plane coordinate space according to Murray's definitions of operative anteversion and operative inclination. Using EOS DICOM images, spatial information from the images were used to reconstruct the fan beam projection model. Each image pair is positioned inside this projection model. Anterior Pelvic Plane coordinate points are digitized on each image and back-projected to the fan beam source. Corresponding beams are then used to compute the 3D intersection points defining the 3D position and orientation of the Anterior Pelvic Plane. Ellipses with adjustable radii were then used to define the cup border in each EOS image. By respecting the fan beam projection model, 3D planes defining the projected normal of the ellipse in each image are computed. 3D implant normal was estimated by determining 3D plane intersection lines for each image pair. Implant center points are defined by using the back-projected and intersected ellipse center beams in the image pairs (Figure 1). Results. The results are shown in Figure 2. The mean anteversion error was −0.9 degrees (SD 4.1, range −6.9 to 10.3). The mean inclination error was 1.8 (SD 2.1, range −2.9 to 8.6). All three cups with errors greater than 7 degrees were in cups with 40 or more degrees of anteversion. Discussion and Conclusion. The current study, while very preliminary, demonstrates the potential that EOS images can be used to measure cup orientation with a reasonable degree of accuracy. Accurate determination of cup orientation appears to be more challenging in cups with higher anteversion


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 137 - 137
1 May 2016
Yabuno K Sawada N Kanazawa M
Full Access

Purpose. Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires through evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. As you know Sir John Charnley is one of the first orthopaedic surgeons to address the issue of soft-tissue tensioning (STT) in the THA. Moreover leg-length discrepancy (LLD) after THA can pose a substantial problem for the orthopaedic surgeon. Such discrepancy has been associated with complications including nerve palsy, low back pain, and abnormal gait. The objective of this study is to assess hip instability of three different FOs in same patient undergoing THA during an operation. Methods. We performed 70 patients who had undergone unilateral THA using CT based navigation system at a single institution for advanced osteoarthoritis from May 2013 to May 2014. We used postero-lateral approach in all patients. After cup and stem implantation, we assessed soft tissue tensioning in THA during operation. Trial necks were categorized into one of three groups: standard femoral offset (sFO), high femoral offset (hFO, +4mm compared to sFO) and extensive high femoral offset (ehFO, +8 mm compared to sFO). We measured distance of lift-off about each of three femoral necks using CT based navigation system and a force gauge with hip flexed at 0 degrees and 30 degrees under a traction of lower extremity. Traction force was 40% of body weight. Results. Forty patients had leg length restored to within +/− 5mm of the contralateral side by post-operative CT analysis. We examined these patients. Traction force was 214±41.1Nm. The distances of lift-off were 8.8±4.5mm (sFO), 7.4±4.1mm (eFO), 5.1±3.9mm (ehFO) with 0 degrees hip flexion and neutral abduction(Abd) / adduction(Add) and neutral internal rotation(IR)/external rotation(ER). The distance of lift-off were 11.5±5.9mm (sFO), 10.5±5.5mm (eFO),ã��9.1±5.9mm (ehFO) with 30 degrees hip flexion and neutral Abd / Add and neutral IR/ER. Significant difference was observed between 0 degrees hip flexion and 30 degrees hip flexion on each FO (p<0.05). On changing the distance of lift-off, hFO to ehFO (2.2±1.6mm) was more stable than sFO to hFO (1.4±1.7mm)with 0degrees hip flexion.(p<0.05). On the other hands, hFO to ehFO (1.4±1.6mm) was more stable than sFO to hFO (1.0±1.3mm) with 30 degrees hip flexion. However, we did not find significant difference (p=0.18). Conclusion. Hip instability was found at 30 degrees hip flexion more than at 0 degrees hip flexion. We found that changing from eFO to ehFO can lead to more stability improvement of soft tissue tensioning than sFO to eFO, especially at 0 degrees hip flexion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 71 - 71
1 Oct 2012
Bäthis H Shafizadeh S Banerjee M Tjardes T Bracke B Neubauer T Bouillon B
Full Access

In order to enhance the acceptance of computer assisted surgery in joint replacement, a development-cooperation with BrainLAB, Germany was set up to develop a user-friendly handheld navigation device. A sterile draped Apple® IPod-Touch which is placed into a hardcover cradle, is used as navigation monitor and touchscreen control. Different instruments, such as navigation-pointer are attached to the cradle. In addition the workflows for TKR and THR procedures have been optimised. Therefore the main focus for TKR is navigation of femoral and tibial resection as well as leg alignment control. For the THR the system enables an intraoperative control of leg-length and femoral-offset measurement in comparison with the preoperative situation. Each step of the procedure is supported by video animations of the specific navigation workflow. Between September and December 2010 the first clinical study on the usability in TKR and THR was performed for 20 cases using a prototype system. The study was approved by the local ethic committee and the “German Federal Institute for Drugs and Medical Devices (BfArM)”. Special interest was taken to the aspects of usability and the necessary time periods for specific steps of the procedure. Usability was measured for specific time periods of the procedure assessment of the usability of the surgical team. In addition postoperative x-rays were evaluated for implant position, leg alignment for TKR and hip joint geometry for THR cases. Throughout the study for each assigned patient the procedure could be performed as planned. Several design inputs were identified for further improvement of the final system. Therefore time measurements of the first five cases were excluded. For the TKR cases the registration process of the last 5 cases was less than 3 minutes. The interval for the tibial resection was between 3 and 7 minutes (aligning tibial cutting block – end of tibial verification). The interval for the distal femur resection was between 7 and 11 minutes (aligning femoral cutting block – end of femoral verification). All 10 Patients showed a final leg alignment on the postoperative standing x-ray within the save-zone of +/− 3° from neutral alignment. For the THR cases the preoperative registration period including the femoral head resection and acetabular registration was between 7 and 12 Minutes. Each final measurement of the hip geometry was done in less than 2 minutes. The evaluation of the pelvic ap-x-ray pre- and postoperative showed equivalent measurements of the new hip geometry compared with the intraoperative measured values. No specific complications occurred throughout the study. In conclusion the BrainLAB–DASH-System has shown a high grade of usability and very short learning curve within this first clinical study. The use of a standard Apple® IPod-touch as a user interface seems to enhance the acceptance of the navigation technique. Equivalent precision compared to standard navigation systems have been demonstrated


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 75 - 75
1 Aug 2013
Marquez-Lara A Curtis D Patel R Stulberg S
Full Access

Femoral components used in total hip arthroplasty (THA) rely on good initial fixation determined by implant design, femoral morphology, and surgical technique. A higher rate of varus alignment may be of specific concern with short stem implants. Varus placement in uncemented femoral components has been proven not to be detrimental to clinical function; though long-term bone remodeling secondary to varus placement remains unknown. The goal of this study was to compare the clinical and radiographic outcomes in patients who underwent THA with one of two uncemented short stem metaphyseal engaging implants at minimum two-year follow-up. A review of 105 patients (average age 65 years; BMI 29 kg/m. 2. ) who underwent a total of 109 primary THAs using the ABG II short stem femoral implant (Stryker, Mahwah, NJ), and 160 hips in 149 patients (average age 70 years; BMI 28 kg/m. 2. ) who underwent primary THA using the Citation stem (Stryker, Mahwah, NJ). The same surgeon (SDS) performed all surgeries through a less invasive posterolateral approach. Pre-operative and post-operative Harris Hips Scores (HHS) and WOMAC scores were collected. Digital radiograph analysis was performed including measuring the stem alignment relative to the femoral shaft. A stem placed with greater than 5 degrees of varus was considered to be in varus. There was no significant difference in demographics (age, gender or BMI) or pre-operative HHS and WOMAC scores between the two groups. Follow-up HHS was 90 (range 63–100) and 94 (range 70–100) for the ABG II and Citation groups, respectively. Follow-up WOMAC scores were 10 (range 0–24) and 6 (range 0–43) for the ABG II and Citation groups, respectively. There was no statistically significant difference in any of the scores between the two groups (p>0.05). When looking at AP radiographs for postoperative intramedullary alignment, none of the ABG II implants were placed in varus (>5°), while a small number (4.9%) of Citation implants were implanted in varus alignment. No significant difference was observed in the alignment between the two groups (p>0.05). Average post-op alignment with the ABG was 1.10° (range −4.7–4.9°) and 0.88° (range −4.5–8.9°) with the Citation. The clinical results associated with the use of these stems in patients of all ages and bone types have been identical to those achieved by uncemented stems of standard length. Both implants in this study had excellent clinical and functional results in primary THA after a minimum 24-month follow up. In addition, postoperative radiographic analysis demonstrated that these stems can be reliably and reproducibly placed in neutral alignment despite their short length. The lateral flare on the Citation implant led to a greater number of implants in varus alignment, potentially affecting offset and leg-length, yet the relative increased incidence compared to the ABG II was not significant. Further research is needed in designing implants that optimize proximal femoral contact while maintaining alignment and overall hip kinematics


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1296 - 1300
1 Sep 2015
Jauregui JJ Bor N Thakral R Standard SC Paley D Herzenberg JE

External fixation is widely used in orthopaedic and trauma surgery. Infections around pin or wire sites, which are usually localised, non-invasive, and are easily managed, are common. Occasionally, more serious invasive complications such as necrotising fasciitis (NF) and toxic shock syndrome (TSS) may occur.

We retrospectively reviewed all patients who underwent external fixation between 1997 and 2012 in our limb lengthening and reconstruction programme. A total of eight patients (seven female and one male) with a mean age of 20 years (5 to 45) in which pin/wire track infections became limb- or life-threatening were identified. Of these, four were due to TSS and four to NF. Their management is described. A satisfactory outcome was obtained with early diagnosis and aggressive medical and surgical treatment.

Clinicians caring for patients who have external fixation and in whom infection has developed should be aware of the possibility of these more serious complications. Early diagnosis and aggressive treatment are required in order to obtain a satisfactory outcome.

Cite this article: Bone Joint J 2015;97-B:1296–1300.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 146 - 152
1 Jan 2010
Bilen FE Kocaoglu M Eralp L Balci HI

We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed.

The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60).

One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation.

We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1394 - 1399
1 Oct 2009
Oh C Song H Kim J Choi J Min W Park B

Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications.

Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 962 - 967
1 Jul 2009
Aston WJS Calder PR Baker D Hartley J Hill RA

We present a retrospective review of a single-surgeon series of 30 consecutive lengthenings in 27 patients with congenital short femur using the Ilizarov technique performed between 1994 and 2005.

The mean increase in length was 5.8 cm/18.65% (3.3 to 10.4, 9.7% to 48.8%), with a mean time in the frame of 223 days (75 to 363). By changing from a distal to a proximal osteotomy for lengthening, the mean range of knee movement was significantly increased from 98.1° to 124.2° (p = 0.041) and there was a trend towards a reduced requirement for quadricepsplasty, although this was not statistically significant (p = 0.07). The overall incidence of regenerate deformation or fracture requiring open reduction and internal fixation was similar in the distal and proximal osteotomy groups (56.7% and 53.8%, respectively). However, in the proximal osteotomy group, pre-placement of a Rush nail reduced this rate from 100% without a nail to 0% with a nail (p < 0.001). When comparing a distal osteotomy with a proximal one over a Rush nail for lengthening, there was a significant decrease in fracture rate from 58.8% to 0% (p = 0.043).

We recommend that in this group of patients lengthening of the femur with an Ilizarov construct be carried out through a proximal osteotomy over a Rush nail. Lengthening should also be limited to a maximum of 6 cm during one treatment, or 20% of the original length of the femur, in order to reduce the risk of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 938 - 942
1 Jul 2006
Singh S Lahiri A Iqbal M

Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest.

The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion.