Introduction. Correct postoperative leg length restoration is among the most important goals of hip arthroplasty. Therefore, we developed, validated and clinically applied a novel software algorithm based on surgical navigation, which allows the surgeon to restore a defined femur position without establishing a femoral coordinate system or the hip joint center and measure the leg length accurately and simply. Material and Methods. This new leg length algorithm was used in 154 hips (145 patients) that underwent CT-based computer-assisted THA (VectorVision Build 274 prototype; BrainLAB AG, Helmstetten, Germany) with a tissue preserving superior capsulotomy. Intraoperatively, a pelvic and a femoral dynamic reference bases (DRB) were applied and the anterior pelvic plane (APP) was set as the pelvic coordinate system. Then, the hip joint was put in a neutral position and this position, and the relative position of the femoral DRB relative to the pelvic DRB, was captured and stored by the navigation system. After implantation of the prosthesis the same above described femoral position with the same amplitude of flexion/extension, abduction/adduction and rotation was restored. Now, any resulting difference was due to linear changes. Validation of this new algorithm was performed by comparing the navigated results to measurements from calibrated antero-posterior pre- and postoperative radiographs. The radiographic results were compared to the mean leg length change measured with the navigation system. Results. No significant difference was found between radiographic leg length change and the results from the navigation system (p=0.658). The mean difference between the radiographic results and the results from the navigation system was −0.5 (1–8 mm (range, −5–4 mm). The mean registration accuracy of the navigation system was 2.04 (0.58 mm (range, 0.70–3.00 mm). Discussion. This novel tool has the potential to increase the accuracy and consistency of
Leg length discrepancy (LLD) is a common sequalae of limb reconstruction procedures. The subsequent biomechanical compensation can be directly linked to degenerative arthritis, lower back pain, scoliosis and functional impairment. It becomes particularly problematic when >2cm, established as a clinical standard. This two-arm experimental study assesses how reliable an iPhone application is in the measurement of LLD at different distances in control and LLD patients. 42 participants were included in the study, divided evenly into 21 control and 21 LLD patients. A standardised measurement technique was used to obtain TMM and iPhone application measurements, taken at a distance of 0.25m, 0.50m and 0.75m.Introduction
Materials and Methods
Introduction. Restoration of anatomy is essential in total hip arthroplasty (THA) to optimize function and stability.
Introduction. Circumferential periosteal release is a rarely reported procedure for paediatric limb lengthening. The technique involves circumferential excision of a strip of periosteum from the metaphysis of the distal femur, tibia and fibula. This study aims to determine the mid to long-term effectiveness of this technique. Materials and Methods. A retrospective case series was performed of all patients undergoing circumferential periosteal release of the distal femur and/or tibia between 2006 and 2017. Data collected included demographics, surgical indication, post-operative limb-lengths and complications. Data collection was stopped if a further procedure was performed that may affect limb-length (except a further release).
Introduction. Primary robotic-arm assisted total hip arthroplasty (THA) yields more accurate and reproducible acetabular cup placement, nonetheless, data is scarce in terms of outcomes. The purpose of the present study was to report on patient-reported outcomes (PROMs) in a large group of patients who underwent robotic-arm assisted THA. The authors hypothesized that (1) patients who underwent robotic-arm assisted primary THA would achieve favorable and significant improvement in PROMs, (2) an accurate and reproducible acetabular cup placement with respect to the defined SafeZones would be obtained, and (3) a low rate of THA dislocation would be observed. Methods. Prospectively collected data were retrospectively reviewed between April 2012 to May 2017. Primary THA using Mako Robotic-Arm [Mako Surgical Corp. (Stryker), Fort Lauderdale, FL, USA] with minimum two-year follow-up for the Harris Hip Score (HHS) and the Forgotten Joint Score-12 (FJS-12) were included. Exclusion criteria were: bodymass index (BMI) > 40 kg/m2, age < 21-year old, worker's compensation, or unwilling to participate. Visual analog scale (VAS) for pain and patient satisfaction were obtained. Intraoperative measurements for
Introduction. Computer navigation is a highly sophisticated tool in orthopedic surgery for component placement in total hip arthroplasty (THA). A number of recommendations have been published. Although Lewinnek's safe-zone is the best-known among these its significance is questioned in recent years since it addresses the acetabular socket only ignoring the femoral stem. Modern target definitions consider both socket and stem and provide well-defined recommendations for complementary component positioning. We present a new small-sized hand-held imageless navigation system that implies these targets and supports the surgeon in realizing the concept of combined anteversion and combined Target-Zone (cTarget- Zone) in THA and to control leg length and offset without altering the standard surgical work-flow and we report initial results. Methods. The targets for positioning the components of a total hip as expressed by radiographic cup inclination (cRI) and anteversion (cRA), stem antetorsion (sAT) and neck-to-shaft angle (sNSA) are determined for a specific prosthesis system using a computerized 3D-model. The optimizing goal is maximizing the size of the cSafe-Zone providing the largest target zone for an impingement-free prosthetic range of motion (pROM) in order to minimize the risk for dislocation in physiologic and combined movements. Independent parameters like head size, head-to-neck ration and also component orientations like cRI, cRA, sAT and sNSA were varied systematically and the optimal cSafe-Zone was computed in semi-automated batch runs. These optimized prosthesis-specific results were introduced into the software of the hand-held navigation system. This system measures leg length, offset, acetabular and femoral head centers intraoperatively. Results. In contrast to Lewinnek the outline of our cSafe-Zone is not rectangular but polygonal. Its size shows prosthesis-specific maxima. The largest zones are found for optimal sNSA values at 126° +/−4°, optimal ranges for cRI depend on head size and range from 44° to 36°, best sAT range from 10° to 18°, cRA from 18° to 25°. There is a prosthesis- specific linear correlation between sAT and cRA that denotes the combined anteversion. The target value for combined anteversion is not dependent on pelvic tilt but on sNSA. The hand-held navigation system displays all these orienting parameters as well as
Introduction. Prosthetic replacement remains the treatment of choice for displaced femoral neck fractures in the elderly population, with recent literature demonstrating significant functional benefits of total hip arthroplasty (THA) over hemiarthroplasty. Yet the fracture population also has historically high rates of early postoperative instability when treated with THA. The direct anterior approach (DAA) may offer the potential to decrease the risk of postoperative instability in this high-risk population by maintaining posterior anatomic structures. The addition of intraoperative fluoroscopy can improve precision in component placement and overcome limitations on preoperative planning due to poor preoperative radiographs performed in the emergency setting. Methods. We retrospectively reviewed clinical and radiographic outcomes of 113 consecutive patients with displaced femoral neck fractures treated by two surgeons over a five-year period. All underwent surgery via the DAA using fluoroscopic guidance, and were allowed immediate postoperative weight bearing without any hip precautions or restrictions. Charts were reviewed for relevant complications, while radiographs were reviewed for component positioning, sizing, and leg length discrepancy. Mean follow-up was 8.9 months. Results. Mean age was 79.3 years (range, 42 to 101), 73% of patients were women, and mean BMI was 22.6 kg/m. 2. Ninety patients (80%) received THA while 23 (20%) received unipolar or bipolar hemiarthroplasty. Mean acetabular anteversion was 15.0 degrees (range, 4 to 24) and mean abduction was 39.2 degrees (range, 27 to 51) with 95% of acetabular components in the combined safe zone as described by Lewinnek. Mean radiographic
There has been a trend towards operative management of pelvic injuries. Posterior pelvic integrity is more important for functional recovery. Percutaneous iliosacral screw fixation is being increasingly preferred for posterior pelvic stabilisation. Outcome reporting for this procedure remains inconsistent and un-standardised. Retrospectively, all percutaneous iliosacral screw fixations done at this institute during a 5-year period (2008–2012) were reviewed. 28 patients, who had had at least 12 months follow-up, were contacted and clinical scoring was done by postal correspondence. Radiographs were measured for displacements and
Introduction. Studies show that cup malpositioning using conventional techniques occurs in 50 to 74% of cases defined. Assessment of the utility of improved methods of placing acetabular components depends upon the accuracy of the method of measuring component positioning postoperatively. The current study reports on our preliminary experience assessing the accuracy of EOS images and application specific software to assess cup orientation as compared to CT. Methods. Eighteen patients with eighteen unilateral THA had pre-operative EOS images were obtained for preoperative assessment of
Purpose. Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires through evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. As you know Sir John Charnley is one of the first orthopaedic surgeons to address the issue of soft-tissue tensioning (STT) in the THA. Moreover
In order to enhance the acceptance of computer assisted surgery in joint replacement, a development-cooperation with BrainLAB, Germany was set up to develop a user-friendly handheld navigation device. A sterile draped Apple® IPod-Touch which is placed into a hardcover cradle, is used as navigation monitor and touchscreen control. Different instruments, such as navigation-pointer are attached to the cradle. In addition the workflows for TKR and THR procedures have been optimised. Therefore the main focus for TKR is navigation of femoral and tibial resection as well as leg alignment control. For the THR the system enables an intraoperative control of
Femoral components used in total hip arthroplasty (THA) rely on good initial fixation determined by implant design, femoral morphology, and surgical technique. A higher rate of varus alignment may be of specific concern with short stem implants. Varus placement in uncemented femoral components has been proven not to be detrimental to clinical function; though long-term bone remodeling secondary to varus placement remains unknown. The goal of this study was to compare the clinical and radiographic outcomes in patients who underwent THA with one of two uncemented short stem metaphyseal engaging implants at minimum two-year follow-up. A review of 105 patients (average age 65 years; BMI 29 kg/m. 2. ) who underwent a total of 109 primary THAs using the ABG II short stem femoral implant (Stryker, Mahwah, NJ), and 160 hips in 149 patients (average age 70 years; BMI 28 kg/m. 2. ) who underwent primary THA using the Citation stem (Stryker, Mahwah, NJ). The same surgeon (SDS) performed all surgeries through a less invasive posterolateral approach. Pre-operative and post-operative Harris Hips Scores (HHS) and WOMAC scores were collected. Digital radiograph analysis was performed including measuring the stem alignment relative to the femoral shaft. A stem placed with greater than 5 degrees of varus was considered to be in varus. There was no significant difference in demographics (age, gender or BMI) or pre-operative HHS and WOMAC scores between the two groups. Follow-up HHS was 90 (range 63–100) and 94 (range 70–100) for the ABG II and Citation groups, respectively. Follow-up WOMAC scores were 10 (range 0–24) and 6 (range 0–43) for the ABG II and Citation groups, respectively. There was no statistically significant difference in any of the scores between the two groups (p>0.05). When looking at AP radiographs for postoperative intramedullary alignment, none of the ABG II implants were placed in varus (>5°), while a small number (4.9%) of Citation implants were implanted in varus alignment. No significant difference was observed in the alignment between the two groups (p>0.05). Average post-op alignment with the ABG was 1.10° (range −4.7–4.9°) and 0.88° (range −4.5–8.9°) with the Citation. The clinical results associated with the use of these stems in patients of all ages and bone types have been identical to those achieved by uncemented stems of standard length. Both implants in this study had excellent clinical and functional results in primary THA after a minimum 24-month follow up. In addition, postoperative radiographic analysis demonstrated that these stems can be reliably and reproducibly placed in neutral alignment despite their short length. The lateral flare on the Citation implant led to a greater number of implants in varus alignment, potentially affecting offset and
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and toxic shock syndrome (TSS) may occur. We retrospectively reviewed all patients who underwent external
fixation between 1997 and 2012 in our limb lengthening and reconstruction
programme. A total of eight patients (seven female and one male)
with a mean age of 20 years (5 to 45) in which pin/wire track infections
became limb- or life-threatening were identified. Of these, four
were due to TSS and four to NF. Their management is described. A
satisfactory outcome was obtained with early diagnosis and aggressive
medical and surgical treatment. Clinicians caring for patients who have external fixation and
in whom infection has developed should be aware of the possibility
of these more serious complications. Early diagnosis and aggressive
treatment are required in order to obtain a satisfactory outcome. Cite this article:
We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.
Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.
We present a retrospective review of a single-surgeon series of 30 consecutive lengthenings in 27 patients with congenital short femur using the Ilizarov technique performed between 1994 and 2005. The mean increase in length was 5.8 cm/18.65% (3.3 to 10.4, 9.7% to 48.8%), with a mean time in the frame of 223 days (75 to 363). By changing from a distal to a proximal osteotomy for lengthening, the mean range of knee movement was significantly increased from 98.1° to 124.2° (p = 0.041) and there was a trend towards a reduced requirement for quadricepsplasty, although this was not statistically significant (p = 0.07). The overall incidence of regenerate deformation or fracture requiring open reduction and internal fixation was similar in the distal and proximal osteotomy groups (56.7% and 53.8%, respectively). However, in the proximal osteotomy group, pre-placement of a Rush nail reduced this rate from 100% without a nail to 0% with a nail (p <
0.001). When comparing a distal osteotomy with a proximal one over a Rush nail for lengthening, there was a significant decrease in fracture rate from 58.8% to 0% (p = 0.043). We recommend that in this group of patients lengthening of the femur with an Ilizarov construct be carried out through a proximal osteotomy over a Rush nail. Lengthening should also be limited to a maximum of 6 cm during one treatment, or 20% of the original length of the femur, in order to reduce the risk of complications.
Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest. The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion.