Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:

Aims. Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. Methods. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs. Results. Overall, 139 ankle fractures were fixed by 28 postgraduate year three to five trainee surgeons (mean age 29.4 years; 71% males) during ten months' follow-up. Under the intention-to-treat principle, a technically superior fixation was performed by the cadaveric-trained group compared to the standard-trained group, as measured on the first postoperative radiograph against predefined acceptability thresholds. The cadaveric-trained group used a lower intraoperative dose of radiation than the standard-trained group (mean difference 0.011 Gym. 2. , 95% confidence interval 0.003 to 0.019; p = 0.009). There was no difference in procedure time. Conclusion. Trainees randomized to cadaveric training performed better ankle fracture fixations and irradiated patients less during surgery compared to standard-trained trainees. This effect, which was previously unknown, is likely to be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):594–601


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 6 - 6
13 Mar 2023
Pawloy K Sargeant H Smith K Rankin I Talukdar P Hancock S Munro C
Full Access

Our unit historically performed total hip replacement (THR) through either posterior or anterolateral approaches. In November 2020 a group of 5 consultants transitioned to utilising the Direct Anterior Approach (DAA). Appropriate training was undertaken and cases were performed as dual consultant procedures with intraoperative radiography or robotic assistance. Outcomes were collated prospectively. These included basic demographics, intraoperative details, complication rates and Oxford Hip Scores. A total of 48 patients underwent DAA THR over 1 year. Mean age was 67 and ASA 2. Over this time period 140 posterior approach and 137 anterolateral approach THR's were performed with available data. Propensity score matching was performed on a 1:1 basis using BMI, Age, Sex and ASA as covariates to generate a matched cohort group of conventional approach THR (n=37). Length of stay was significantly reduced at 1.95 days (p<0.001) with DAA compared to Anterolateral and Posterior approach. There was no significant difference with length of surgery, blood loss, Infection, dislocation and periprosthetic fracture rate. There was no significant difference in Oxford Hip Score between any approach at 3 months or 1 year. The transition to this approach has not made a negative impact despite its associated steep learning curve, and has improved efficiency in elective surgery. From our experience we would suggest those changing to this approach receive appropriate training in a high-volume centre, and perform cases as dual consultant procedures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 435 - 435
1 Sep 2012
Adam P Taglang G Brinkert D Bonnomet F Ehlinger M
Full Access

Introduction. Locking nail have considerably improved the treatment of long weight bearing bones. However, distal locking needs experience and may expose to radiations. Many methods have been proposed to facilitate distal locking and improve safety. Recently, an external distal targeting device adapted to the ancillary of the Long Gamma Nail has been proposed. We report our experience with this device through a comparative series of distal lockings. Aim of this work was to assess feasibility and advantages brought about with this targeting device when considering time or dose of irradiation. Material and methods. Two prospective series of 50 distal locking performed by an experienced surgeon have been compared. Two methods were compared: the classical freehand technique using a Steinmann rod with the image of rounded holes, and the external distal targeting device. The following datas were collected: technical difficulties with either technique, locking mistakes and duration of exposure to radiations. Results. Two locking errors were observed using the targeting device, in pathological fractures with the use of a titanium nail. These cases belonged to the five earliest cases. External targeting device requires a learning curve that is reasonnably short with little difficulties encountered. Ther is a fundamental difference between the two series concerning exposure to radiations. In the freehand technique mean exposure was 25,8s (6–38) and it was 8,6s (6–18) with the dital targeting device. Discussion. A short learning curve confirms the ease of use of the distal targerting device. Diminution of exposure to radiation is effectively obtained. Some factors may increase the risk of error: the use of very long nails and the use of titanium nails as this may increase motion at distal end. Conclusion. The external visor is an efficient device as it facilitates distal locking and alllows for a diminution of irradiation time


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 386 - 386
1 Sep 2012
Josten C Jarvers J Riesner H Franck A Glasmacher S Schmidt C
Full Access

Purpose. In stabilisations of atlantoaxial instabilities it holds risks to injure the A. vertebralis as well as neurological structures. Furthermore the posterior approach of the upper part of the cervical spine requires a huge and traumatic preparation of the soft tissue. However the anterior transarticular C1-2 fusion (ATF) is less traumatic and offers almost the same strengh of the stabilisation. Methods. Since the 01/2007 22 multimorbid patients with atlanto-axial instabilities of different entities were treated via the ATF, were regular examined radiologicaly (x-ray/CT) and the procedure critically judged. Results. C1-2 fusions were performed in 22 patients (17f, 5m, Ø 81,67 years). Main symptoms was pain radiating in the upper cervical spine and the occiput, 2 Patients complaining radiating pain with paraesthesia. The average operation-time took 64,5 min. Leftside the screws of Ø 39,5mm (32–44mm), rightside of 36mm (32–44mm) were inserted in addiction to the point of access and the angle of insertion (mediolateral angle Ø 32,0°, ventrodorsal Ø17,6°). No introperative complications occured, one revision had to be done because of p.o. bleeding, one because of screw dislocation. Postoperative x-ray and CT control of the upper cervical spine showed 30/44 screws in 22 patients in correct position. 8 (18,2%) screws were too long, 3 (6,8%) screws were placed too anterior and 3 (6,8%) too medial. 8 additional positionated dens-screws were in correct position. After a clear learning curve both screws of the 6th patient were positoinated correct. Two aspects are important for success: Correct entry point and right insertion of the angle in the coronar and sagittal view. A low intraoperative blood loss, a non traumatic access as well as an immediate pain decrease have to be valued positively for this procedure. Conclusions. The gentle procedure of the ATF requires-despite of the huge experience in anterior surgery of dens fractures - a learning curve, because of the more proximate insertion point, the flat insertion angle and the closeness of the A. vertebralis. If these aspects are going to be noticed, failed screw positioning and excessive length as well as injuries of the A. vertebralis can be avoided


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 15 - 15
1 May 2018
Dhital K Giles SN Fernandes JA
Full Access

Introduction. Aim of this study was to review a single surgeon series and analyse the results of hip reconstruction and compare them to an historical cohort. Methods and results. Retrospective review from a prospective database was undertaken of 113 CFD children since 1999. 31 of these patients had hip reconstruction with combined soft tissue and bony procedures akin to the Superhip. This cohort was compared to the results of the previous series using deformity planning methods on radiographic imaging, quantification of acetabular and femoral geometry, focussing upon the effects and results of hip reconstruction and lengthening. Compared to the previous series, this cohort achieved greater objective increases in length and significantly fewer complications involving the hip joint during the process.11 hips out of 45 (24.4%) that were treated in the previous cohort subluxed during lengthening. Since 1999 there were no subluxations with improved hip geometry. Primary difference between the cohorts was the recent group's preparatory hip surgery before the commencement of any lengthening even for borderline dysplasias. This had not been the case for all children in the previous cohort. This indicates a steep learning curve in the last 3 decades concerning the importance of primary hip reconstruction as a preparatory stage of treatment before lengthening in CFD with almost normalised acetabulae. Conclusion. Management of CFD needs detailed and methodical planning of soft tissue and bony deformities and better understanding has evolved over time to provide improved results and outcomes. Level of evidence. Therapeutic III


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture.

Methods

This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 388 - 388
1 Sep 2012
Sanchis Amat R Crespo Gonzalez D Juando Amores C Espi Esciva F Balaguer Andres J
Full Access

INTRODUCTION. Percutaneous surgery is an increasingly accepted technic for the treatment of Hallux valgus but it has some limitations when the intermetatarsal angle ismoderate to severe, having high risk of recurrence. The mini tight-rope used as a complement for precutaneous surgery avoids complications of open surgery osteotomies (delays consolidation, pain, screws protusion, infection) and it allows us continue with the recurrent trend towards minimal invasive surgery. MATERIAL AND METHOD. Between 2007 and 2009, 60 patients with severe Hallux valgus were treated in our Hospital using the percutaneous mini tight-rope. The mean age of patients was 62, 5 patients were man and 55 were woman. The mean follow-up was 18 months. RESULTS. Patients had clinical assessment using AOFAS score, radiological assessment and a subjective satisfaction degree assessment at 2,6 weeks and 4-6-12 months postoperative. As complications we found four technical failures due to learning curve, one infection and one second metatarsal fracture. CONCLUSION. mini tight-rope is a good option as a supplement in the treatment of severe hallux valgus by percutaneous technique because it avoids complications of open surgery, obtaining satisfactory results in 76% of cases according to the AOFAS scale


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 265 - 265
1 Sep 2012
Silvestre C Mac Thiong J Hilmi R Roussouly P
Full Access

Background Context. Different minimally invasive approaches to the lumbar spine have been proposed but they can be associated with increased risk of complications, steep learning curve and longer operative time. Purpose. To report the complications associated with a minimally invasive technique of retroperitoneal anterolateral approach to the lumbar spine. Study design. Retrospective study of 179 patients who underwent anterior oblique lumbar interbody fusion (OLIF). Methods. A total of 179 patients with previous posterior instrumented fusion undergoing OLIF were included. This muscle-splitting approach consists in anterolateral exposure through a 4 cm incision followed by placement of a PEEK cage filled with bone graft and/or substitute. Results. Patients were aged 54.110.6 years with BMI of 24.84.1 kg/m2. Length of follow-up was (0.90.7 years), including 17 patients with a minimum follow-up of 2 years. A left-sided approach was done in 174 patients. The procedure was performed at L1–2 in 4, L2–3 in 54, L3–4 in 120, L4–5 in 134 and L5-S1 in 6 patients. It was done at 1 level in 56, 2 levels in 107, and 3 levels in 16 patients. Operative time and blood loss were respectively 32.513.2 min and 57131 cc per level fused. There were 19 patients with single complication and one with two complications, including two patients with postoperative radiculopathy after L3–5 OLIF. There was no abdominal weakness or herniation. Conclusion. Minimally invasive OLIF can be performed easily and safely from L2 to L5, and at L1–2 and L5-S1 for selected cases. Up to 3 levels can be addressed through a “sliding window”. It is associated with minimal blood loss and short operative time. The risk of complications is similar to that reported for traditional anterior approaches, with the advantage of decreasing the risk of abdominal wall weakness or herniation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 352 - 352
1 Sep 2012
Nicodemo A Governale G Stucchi A Valente A Cuocolo C Massè A
Full Access

Introduction. Between 2002–2009 we operatively treated 193 acetabular fracture. Among these 44 both-columns fractures according to the classification of Letournel and Judet have been reviewed in order to evaluate the results. These fractures are rare, difficult to treat and often have poor clinical results. Patients and Methods. 44 cases of ORIF of displaced both columns fractures have been studied at a mean 37 months follow-up (range, 13 to 76 months) after the injury. 40 hips were operated with the ilioinguinal approach alone, 1 with Kocker Langenbeck and Smith petersen combined. The 3 remaining hips were operated with a double Kocher-Langenbeck and ilioinguinal approach. Every case was evalueted on X-rays according to Matta criteria and clinically with the Harris hip score and the WOMAC score. Results. The mean Harris hip score has been 85,8% (range 30%–100%) while the mean WOMAC score has been 88,3 points (range 39,1–100). The main complications were 4 early post-traumatic arthritis operated by hip replacement. One patient instead developed a gastric carcinoma. Discussion. The rate of anatomical reduction decreased with the complexity of the fracture, the age, and the interval between the injury and the reduction. The clinical result was adversely affected by associated injuries of the femoral head, an older age of the patient. It was positively affected by an anatomical reduction and postoperative congruity between the femoral head and the acetabular roof. Conclusions. These findings indicate that in many patients who have a complex acetabular fracture the hip joint can be preserved and post-traumatic osteoarthritis can be avoided if an anatomical reduction is achieved. Both column acetabular fractures can be reduced with a combined surgical approaches or with ilioinguinal alone. We used the ilioinguinal approach alone in 91% of cases reaching good results, even comparing Letournel and Matta's results. Surgeon experience and a long learning curve can help in decision making and in obtaining an anatomical reduction with a low rate of post-operative complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 248 - 248
1 Sep 2012
Su E
Full Access

Hip resurfacing has grown rapidly since its introduction in the United States, as an alternative to total hip replacement in the younger, active patient. Some studies have suggested a steep learning curve and a higher complication rate when compared to THR. Existing studies have originated from the pioneering surgeons, using a specific type of resurfacing implant. The purpose of this study was to look at the experience of a single, non-inventor surgeon with the adoption of hip resurfacing, using 3 different implants. M&M. All consecutive hip resurfacings performed by the senior surgeon between 2004 and 2008 were included, providing a minimum 2 year followup period. 3 different implant types were used; 2 of these were used as part of the clinical trials, and 1 was used after US FDA approval. A total of 560 hip resurfacings were eligible for the study based upon a minimum of 2 year followup. Results. Nine revisions were performed in this cohort (1.6%). 2 were femoral conversions to endoprostheses for femoral neck fracture; 3 additional femoral conversions were done for osteonecrosis of the femoral head. 1 acetabular revision only was performed for malposition. 2 revisions to THR of both the acetabular and femoral components were done for acetabular loosening and excessive metal production (edge loading). There was 1 revision for metal hypersensitivity. Overall, the K-M survival curve is 98.1% at 4 years. There was no difference with regard to survival from additional surgery with regard to the different implant types. Radiographic signs of failure were also documented. In this cohort, 3 femoral and 1 acetabular components were identified to be radiographically loose, giving a K-M survival from clinical and radiographic failure to be 96.8% at 4 years. Discussion. Hip resurfacing can be adopted successfully with a low rate of reoperation, by the use of careful patient selection. A single surgeon's experience with 3 different types of implants demonstrated no difference in clinical results between the devices


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 124 - 124
1 Sep 2012
Torkos M Gimesi C Toth Z Bajzik G Magyar A Szabo I
Full Access

Goal. The goal of this prospective, non-randomized study is to compare functional and life-quality changes in primary total hip replacement (THR) with minimally invasive anterior (MIA) and direct lateral (DL) approach in six months follow-up. Materials and Methods. Sixty (30 MIA and 30 DL) consecutive patients underwent primary THR were operated by the same senior surgeon. Patients completed functional and life-quality scores (Oxford Hip Score, Harris Hip Score, EQ-5D) before operation and four times (2 and 6 weeks, 3 and 6 months) after THR. Physical examination was taken all times. 15–15 patients underwent MRI examination to adjudge status of abductor muscles. The average patient age was approximately equal in both group. Results. The average OHS values were 13,4; 27,5; 40,9; 45,3; 47,5 in MIA and 15,3; 25,3; 39,7; 43,8; 45 in DL, the average HHS values 43,1; 68,7; 85,3; 91,9; 96,7 in MIA and 43; 58,2; 81,5; 90,2; 93,9 in DL, the average EQ-VAS 41,1; 72,5; 85,9; 87,8; 92,4 in MIA and 55,6; 67,8; 80,6; 84; 91,3 in DL consecutively. In MIA group both functional and life-quality scores showed better results, but for the 3rd postoperative month increases were approximately equal. Abductor muscle strength was significantly greater in MIA group in this period. In the 6th postoperative week Trendelenburg-sign was detected in 24 cases (80%) in DL and in 2 cases (6,7%) in MIA group, but in MIA patients were greater trochanter fractures, which had gone healing and limping was not detected 3 months after surgery. 3 months after surgery Trendelenburg-sign was detected in 2 cases in DL group. In follow-up period residual trochanteric pain was detected in 3 cases in DL but none in MIA group. Two weeks after THR climbing a flight of stairs was normal and public transport could be used by 80% of patients in MIA group. Distance walk was unlimited, support had not needed, daily activities were easy. There were 7 operative complications in MIA group, including 2 greater trochanter fracture, 1 haematoma and 4 transient lateral femoral cutaneous nerve palsy, which showed change for the better after 6 months. Postoperative hip dislocation was not detected. In DL group MRI represented fatty infiltration and atrophy of abductor muscles in most cases. Conclusions. Besides the fact that our learning curve may influence the results. It seems that earlier mobilisation and faster postoperative recovery can be achieved by MIA approach, which have many financial and social benefits. It preserves muscles and tendons, which probably can influence the long-term results. By preventing abductor muscles can assure better gait pattern. Of course additional long-term studies are needed


Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims

The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing.

Methods

A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims

This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)).

Methods

A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 103 - 114
13 May 2020
James HK Gregory RJH Tennent D Pattison GTR Fisher JD Griffin DR

Aims

The primary aim of the survey was to map the current provision of simulation training within UK and Republic of Ireland (RoI) trauma and orthopaedic (T&O) specialist training programmes to inform future design of a simulation based-curriculum. The secondary aims were to characterize; the types of simulation offered to trainees by stage of training, the sources of funding for simulation, the barriers to providing simulation in training, and to measure current research activity assessing the educational impact of simulation.

Methods

The development of the survey was a collaborative effort between the authors and the British Orthopaedic Association Simulation Group. The survey items were embedded in the Performance and Opportunity Dashboard, which annually audits quality in training across several domains on behalf of the Speciality Advisory Committee (SAC). The survey was sent via email to the 30 training programme directors in March 2019. Data were retrieved and analyzed at the Warwick Clinical Trials Unit, UK.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 155 - 161
1 Feb 2020
McMahon SE Diamond OJ Cusick LA

Aims

Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort.

Methods

We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 162 - 169
1 Feb 2019
Catagni MA Azzam W Guerreschi F Lovisetti L Poli P Khan MS Di Giacomo LM

Aims

Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental tibial bone defects. However, the difference in the incidence of additional procedures, the true complications, and the final results have not been investigated.

Patients and Methods

A total of 86 consecutive patients with a long tibial bone defect (≥ 8 cm), who were treated between January 2008 and January 2015, were retrospectively reviewed. A total of 45 were treated by BFT and 41 by TFT. The median age of the 45 patients in the BFT group was 43 years (interquartile range (IQR) 23 to 54).


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1417 - 1422
1 Oct 2015
Ferreira N Marais LC Aldous C

Tibial nonunion represents a spectrum of conditions which are challenging to treat, and optimal management remains unclear despite its high rate of incidence. We present 44 consecutive patients with 46 stiff tibial nonunions, treated with hexapod external fixators and distraction to achieve union and gradual deformity correction. There were 31 men and 13 women with a mean age of 35 years (18 to 68) and a mean follow-up of 12 months (6 to 40). No tibial osteotomies or bone graft procedures were performed. Bony union was achieved after the initial surgery in 41 (89.1%) tibias. Four persistent nonunions united after repeat treatment with closed hexapod distraction, resulting in bony union in 45 (97.8%) patients. The mean time to union was 23 weeks (11 to 49). Leg-length was restored to within 1 cm of the contralateral side in all tibias. Mechanical alignment was restored to within 5° of normal in 42 (91.3%) tibias. Closed distraction of stiff tibial nonunions can predictably lead to union without further surgery or bone graft. In addition to generating the required distraction to achieve union, hexapod circular external fixators can accurately correct concurrent deformities and limb-length discrepancies.

Cite this article: Bone Joint J 2015;97-B:1417–22.