Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 10 - 10
13 Mar 2023
Rankin C Coleman S Robinson P Murray I Clement N
Full Access

We aim to determine the differences in lower limb joint kinematics during the golf swing of patients who had undergone Total Knee Arthroplasty (TKA) and a control group of native knee golfers.

A case-control study was undertaken with ten golfers who had undergone TKA (cruciate retaining single radius implant) and five age and matched golfers with native knees. Each golfer performed five swings with a driver whilst being recorded at 200Hz by a ten-camera motion capture system. Knee and hip three-dimensional joint angles (JA) and joint angular velocities (JAV) were calculated and statistically compared between the groups at six swing events.

The only significant differences in knee joint kinematics between TKA and control groups was a lower external rotation JA in the left knee during the backswing (p=0.010). There was no significant difference in knee JAV between the groups. Both hips demonstrated significantly (p=0.023 for left and p=0.037 for right) lower flexion in the TKA group during the takeaway swing event, and there was lower internal rotation in the backswing and greater external rotation in the downswing of the right hip. There was also slower left hip extension JAV in the downswing.

Normal knee kinematics were observed during the golf swing following TKA, with the exception of reduced external rotation in the left knee during the back swing and the right during the down swing. The differences demonstrated in the hip motion indicate that they may make compensatory movements to adjust to the reduced external rotation demonstrated in the knee.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 92 - 92
1 Sep 2012
Verdonk P Beekman P De Coninck T Verdonk R Raat F
Full Access

Purpose. to evaluate the kinematics of a knee with a polyurethane meniscal scaffold for partial meniscus defect substitution during flexion under weightbearing conditions in an upright MRI. In addition, radial displacement and the surface of the scaffold was compared to the normal meniscus. Materials and Methods. One cadaver with a normal lateral meniscus and medial scaffold in the left knee and with a normal medial meniscus and lateral scaffold in the right knee. The scaffolds were implanted to substitute a 3 cm meniscus defect in the posterior horn. The cadaver was scanned in an 0,7T open MRI with a range of motion from 0-30-60-90 to hyperflexion. Kinematics were evaluated on sagittal images by the following two parameters: the position of the femoral condyle, identified by the centre of its posterior circular surface, which is named the flexion facet centre (FFC), and the point of closest approximation between the femoral and tibial subchondral plates, the contact point (CP). Both were identified in relation to the posterior tibial cortex. The displacement, measured on coronal images, is defined as the distance between the tibial plateau and the outer edge of the meniscus. The surface was also measured on coronal slices and contains the triangular surface of the meniscus. Results. Medially from 0 degrees to hyperflexion the FFC does not move anteroposteriorly. Laterally the FFC moves 12 mm backwards. The CP moves 15 mm backwards both lateral and medial. The lateral femoral condyle does roll-back with flexion but the medial does not, so the femur rotates externally around a medial centre. By contrast, both medial and lateral contact points move back, roughly in parallel, from 0 degrees to hyperflexion. The kinematics of the involved compartment is not influenced by the presence of the scaffold compared to the controlateral normal compartment. The radial displacement remains stable during full flexion: both the normal and scaffold meniscus have no different (p > 0,05) position. Both for the normal and the scaffold meniscus there is no difference (p > 0,05) in surface; there is no compression of the meniscus during flexion. Conclusion. The polyurethane implant, indicated for partial meniscus defect substitution, has no effect on the normal kinematics of the knee. Additionally, the degree of flexion has no effect on the external displacement, the surface and compressibility of both the implanted scaffold and the meniscus


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 350 - 350
1 Sep 2012
Aksahin E Guzel A Yuksel H Celebi L Erdogan A Aktekin C Bicimoglu A
Full Access

Aim

The purpose of this study was to analyze the patellofemoral kinematics in neglected adult developmental dysplasia of the hip patients with patellofemoral symptoms and tried to clarify the affect of the severity of dislocation, the amount of limb length discrepancy, the deviation of mechanical axis and the changes in femoral anteversion on patellofemoral alignment.

Methods

The dynamic patellofemoral CT results of 39 patients with DDH suffering from knee pain were reviewed. The mean age was 40.07 (range: 22–61). 14 of them were bilateral and 25 were unilateral neglected DDH patients. The CT results of 12 patients suffering from unilateral patellofemoral pain following the treatment of locked intramedullary nailing was taken as control group. In this patients atraumatic and asymptomatic normal site was taken as control group.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 39 - 39
1 Sep 2012
Lee MC Lee SM Seong SC Lee S Jang J Lee JK Shim SH
Full Access

Summary

UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA.

Introduction

Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 342 - 342
1 Sep 2012
Migaud H Marchetti E Combes A Puget J Tabutin J Pinoit Y Laffargue P
Full Access

Introduction

The same cup orientation is classically applied to all cases of hip replacement (45° abduction, 20° anteversion). We hypothesize that this orientation must be adapted to the patient's hip range of motion. We tested this hypothesis by means of an experimental study with respect to hip range of motion, comparing the classical orientation (45° and 20°), and the orientation obtained with computer-assisted navigation.

Material and Methods

The experimental model included a hemipelvis equipped with a femur whose mobility was controlled for three configurations: stiff (60°/0°, 15°/10°, 10°/10°), average (80°/10°, 35°/30°,35°/25°), mobile (130°/30°, 50°/50°, 45°/35°). The hemipelvis and the cup holder were equipped with an electromagnetic system (Fastrack ™) to measure cup orientation. The Pleos™ navigation system (equipping the hemipelvis, the femur, and the cup holder) guided the cup orientation by detecting the positions risking impingement through a kinematic study of the hip. Nine operators each performed 18 navigation-guided implantations (162 hip abduction, anteversion, and range of movement measurements) in two series scheduled 2 months apart.