Aim. Orthopedic implants play a tremendous role in fixing bone damages due to aging as well as fractures. However, these implants tend to get colonized by bacteria on the surface, leading to infections and subsequently prevention of healing and osteointegration. Recently, Roupie et al. showed that a nisin layer-by-layer based coating applied on biomaterials has both osteogenic and antibacterial properties. The Galleria mellonella larva is a well-known insect infection model that has been used to test the virulence of bacterial and fungal strains as well as for the high throughput screening of antimicrobial compounds against infections. Recently, we have developed an insect infection model with G. mellonella larvae to study implant-associated biofilm infections using Kirschner (K)-wires as implant material. Here, we would like to test the antibacterial capacity of nisin layer-by-layer based coatings on
Distal interphalangeal joint (DIPJ) fusion using a k-wire has been the gold standard treatment for DIPJ arthritis. Recent studies have shown similar patient outcomes with the headless compression screws (HCS), however there has been no cost analysis to compare the two. Therefore, this study aims to 1) review the cost of DIPJ fusion between k-wire and HCS 2) compare functional outcome and patient satisfaction between the two groups. A retrospective review was performed over a nine-year period from 2012-2021 in Counties Manukau. Cost analysis was performed between patients who underwent DIPJ fusion with either HCS or k-wire. Costs included were surgical cost, repeat operations and follow-up clinic costs. The difference in pre-operative and post-operative functional and pain scores were also compared using the patient rate wrist/hand evaluation (PRWHE). Of the 85 eligible patients, 49 underwent fusion with
Purpose. To elucidate whether there is an advantage in external fixation supplementation of
Olecranon fractures are common injuries representing roughly 5% of pediatric elbow fractures. The traditional surgical management is open reduction and internal fixation with a tension band technique where the pins are buried under the skin and tamped into the triceps. We have used a modification of this technique, where the pins have been left out of the skin to be removed in clinic. The purpose of the current study is to compare the outcomes of surgically treated olecranon fractures using a tension-band technique with buried
Introduction. Derotation osteotomies are commonly performed in paediatric orthopaedic and limb reconstruction practice. The purpose of this study was to determine whether the use of a digital inclinometer significantly improves the accuracy in attaining the desired correction. Materials & Methods. We designed an electronic survey regarding derotation femoral osteotomy (DFO) including methods of intra-operative angular correction assessment and acceptable margins of error for correction. This was distributed to 28 paediatric orthopaedic surgeons in our region. A DFO model was created, using an anatomic sawbone with foam covering. 8 orthopaedic surgeons each performed two 30-degree DFOs, one using
Aim. In trauma surgery, the development of biomaterial-associated infections (BAI) is one of the most common complications affecting trauma patients, requiring prolonged hospitalization and the intensive use of antibiotics. Following the attachment of bacteria on the surface of the biomaterial, the biofilm-forming bacteria could initiate a chronic implant-related infection. Despite the use of conventional local and systemic antibiotic therapies, persistent biofilms involve various resistance mechanisms that contribute to therapeutic failures. The development of in vivo chronic BAI models to optimize antibiofilm treatments is a major challenge. Indeed, the biofilm pathogenicity and the host response need to be finely regulated, and compatible with the animal lifestyle. Previously, a Galleria mellonella larvae model for the formation of an early-stage biofilm on the surface of a Kirschner (K)-wire was established. In the present study, two models of mature biofilm using clinical Staphylococcus aureus strains were assessed: one related to contaminated
Aim. To investigate the ability of the bacteriophage Sb-1 to treat and prevent implant-associated infections due to methicillin-resistant Staphylococcus aureus (MRSA) in Galleria mellonella larvae implanted with a K-wire. Method. The stability of Sb-1 in G. mellonella larvae was investigated by injecting a phage titer of 10. 8. PFU and evaluating the presence of Sb-1 in hemolymph at different time points. For infection experiments, sterile stainless-steel
Aim. In vivo biofilm models play major role to study biofilm development, morphology, and regulatory molecules involve in biofilm. Due to ethical restrictions, the use mammalian models are replaced with other alternative models in basic research. Recently, we have developed insect infection model G. mellonella larvae to study implant associated biofilm infections. This model organism is easy to handle, cheap and ethical restriction free and could be used for the high through put screening of antimicrobial compounds to treat biofilm. To promote the use of this model in basic research we aimed to validate this based on the typical biofilm features such as less susceptible to the antibiotics, complexity of the biofilm structure and gene expression profile of biofilms. Method. G. mellonella larvae are maintained at 30oC on artificial diet in an incubator. Titanium and Stainless steel
Aim. To evaluate whether sonication of implant material and subsequent culturing add clinical relevance to culturing of tissue biopsies for improved antibiotic treatment in treatment of bone and joint infection. Method. A retrospective examination of patients’ charts and microbiological analyses in patients who had explanted material (plates, screws,
Aim. Fungal periprosthetic joint infections are difficult to treat and often associated with a limited outcome for patients. Candida species account for approximately 90% of all fungal infections. In vivo biofilm models play major role to study biofilm development, morphology, and regulatory molecules for bacteria. However, in vivo modeling of biofilm-associated fungi models are very rare. Furthermore, due to ethical restrictions, mammalian models are replaced with other alternative models in basic research. Recently, we have developed insect infection model G. mellonella larvae to study implant associated biofilm infections with bacteria. This model organism was not used for fungi biofilm infection yet. Thus, we aimed to establish G. mellonella as in vivo model to study fungal implant infections using Candida albicans as model organism and to test anti-fungal medication. Method. Titanium and Stainless steel
Greater trochanter fractures after total hip replacement have been reported in up to 5% of cases. The outcomes are generally poor. Treatment options include non-operative care or surgical treatment with cerclage wires or a claw plate. We present a simple tension band technique for acute fractures with a single bony fracture fragment. We have not used the technique for chronic or comminuted fractures. Technique: 2.5mm
Scaphoid non-union results the typical humpback deformity, pronation of the distal fragment, and a bone defect in the non-union site with shortening. Bone grafting, whether open or arthroscopic, relies on fluoroscopic and direct visual assessment of reduction. However, because of the bone defect and irregular geometry, it is difficult to determine the precise width of the bone gap and restore the original bone length, and to correct interfragmentary rotation. Correction of alignment can be performed by computer-assisted planning and intraoperative guidance. The use of computer navigation in guiding reduction in scaphoid non-unions and displaced fractures has not been reported. Objective. We propose a method of anatomical reconstruction in scaphoid non-union by computer-assisted preoperative planning combined with intraoperative computer navigation. This could be done in conjunction with a minimally invasive, arthroscopic bone grafting technique. Methods. A model consisting of a scaphoid bone with a simulated fracture, a forearm model, and an attached patient tracker was used. 2 titanium
Symptomatic flexion deformity of proximal interpahalangeal joint (PIPJ) is one of the most common foot deformities and usually treated with arthrodesis. In general, percutaneous
The use of percutaneous Kirschner wires [K-wires] and plaster is a popular method of treatment for displaced distal radius fracture. However, multi-database electronic literature review reveals unsurprisingly different views regarding their use. From August 2002 till June 2004, 280 distal radial fractures were admitted to our orthopaedic department. They were recorded prospectively in the departmental trauma admissions database. We studied the 87 cases treated with the
Background. Percutaneous K-wire fixation is a well-recognised and often performed method of stabilisation for distal radius fractures. However, there is paucity in the literature regarding the infection rate after percutaneous K-wire fixation for distal radius fractures. Aims. To analyse the rate and severity of infection after percutaneous K-wire fixation for distal radius fractures. Material and methods. Between October 2004 and June 2005, 43 patients with closed distal radius fractures had percutaneous K-wire fixation. The wires were left outside the skin in all the cases for easy removal at the end of six weeks at the clinic. They were followed up in the clinic at 1, 2, 4, and 6 weeks. The pin tracts were examined at 2 weeks and six weeks, or if needed earlier. The severity of pin tract infection was graded using modified Oppenheim classification. Results. Out of 43 patients, the male to female ratio was 13:30. The mean age was 49.1 years (range 5-86 years). There were nine cases of pin tract infection, out of which three were grade I, three were grade II, two were grade III, and one was grade IV. In three cases the
Introduction. A recent retrospective study of distal femoral physeal fractures (DFPFs) suggested closed manipulation alone has a high incidence of re-displacement, malunion or physeal bar formation. The paper concluded that all displaced DFPFs require internal fixation, and breaching the physis with
Acetabular distraction for the treatment of chronic pelvic discontinuity was first described by Sporer and Paprosky. The authors advocate the posterolateral approach for exposure of the posterior ilium and posterior column, The patient is secured in the lateral decubitus position. Following a systematic approach to surgical exposure, acetabular component removal should be performed with “cup out” osteotomes resulting in minimal iatrogenic bone loss. Following component removal and confirmation of a chronic discontinuity determine the integrity of the remaining AS and PI columns. If porous metal augments are needed for primary stabilization, the augments are placed prior to cup insertion for reconstruction of the AS and/or PI column. Next, Kirschner (K) wires (size 2.4) are placed in the remaining AS and PI bone so that the distractor can be secured in an extra-acetabular position. The distractor is placed over the
Previous studies describing drill trajectory for single incision distal biceps tendon repair suggest aiming ulnar and distal (Lo et al). This suggests that the starting point of the drill would be anterior and radial to the anatomic insertion of the distal biceps tendon. Restoration of the anatomic footprint may be important for restoration of normal strength, especially as full supination is approached. To determine the safest drill trajectory for preventing injury to the posterior interosseous nerve (PIN) when repairing the distal biceps tendon to the ANATOMIC footprint through a single-incision anterior approach utilising cortical button fixation. Through an anterior approach in ten cadaveric specimens, three drill holes were made in the radial tuberosity from the centre of the anatomic footprint with the forearm fully supinated. Holes were made in a 30º distal, transverse and 30º proximal direction. Each hole was made by angling the trajectory from an anterior to posterior and ulnar to radial direction leaving adequate bone on the ulnar side to accommodate an eight-millimetre tunnel. Proximity of each drill trajectory to the PIN was determined by making a second incision on the dorsum of the proximal forearm. A K-wire was passed through each hole and the distance between the PIN and K-wire measured for each trajectory. The PIN was closest to the trajectory
The detailed biomechanical mechanism of annulus fibrosus under abnormal loading is still ambiguous, especially at the micro and nano scales. This study aims to characterize the alterations of modulus at the nano scale of individual collagen fibrils in annulus fibrosus after in-situ immobilization, and the corresponding micro-biomechanics of annulus fibrosus. An immobilization model was used on the rat tail with an external fixation device. Twenty one fully grown 12-week-old male Sprague-Dawley rats were used in this study. The rats were assigned to one of three groups randomly. One group was selected to be the baseline control group with intact intervertebral discs (n=7). In the other two groups, the vertebrae were immobilized with an external fixation device that fixed four caudal vertebrae (C7-C10) for 4 and 8 weeks, respectively. Four
Olecranon Osteotomy is a common approach used in the management of intraarticular distal humerus fractures. Significant complication rates have been associated with this procedure, including non-union rates of 0–13% and implant removal rates between 12–86%. This study is a multicentre retrospective study involving the largest cohort of olecranon osteotomies in the literature, examining implant fixation types, removal rates and associated complications. Patients were identified between 2007 and 2017 (minimum one year follow-up) via Canadian Classification of Health Interventions (CCI) coding and ICD9/10 codes by our health region's data information service. CCI intervention codes were used to identify patients who underwent surgery for their fracture with an olecranon osteotomy. Reasons for implant removal were identified from a chart review. Our primary outcome was implant removal rates. Categorical data was assessed using Chi square test and Fischer's Exact test. Ninety-nine patients were identified to have undergone an olecranon osteotomy for treatment of a distal humerus fracture. Twenty patients had their osteotomy fixed with a plate and screws and 67 patients were fixed with a tension band wire. Eleven patients underwent “screw fixation”, consisting of a single screw with or without the addition of a wire. One patient had placement of a cable-pin system. Of patients who underwent olecranon osteotomy fixation, 34.3% required implant removal. Removal rates were: 28/67 for TBW (41.8%), 6/20 plates (30%), 0/1 cable-pin and 0/11 for osteotomies fixed with screw fixation. Screw fixation was removed less frequently than TBW p<.006. TBW were more commonly removed than all other fixation types p<.043. Screws were less commonly removed than all other fixation types p<.015. TBW were more likely to be removed for implant irritation than plates, p<.007, and all other implants p<.007. The average time to removal was 361 days (80–1503 days). A second surgeon was the surgeon responsible for the removal in 10/34 cases (29%). TBWs requiring removal were further off the olecranon tip than those not removed p=.006. TBWs were associated with an OR of 3.29 (CI 1.10–9.84) for implant removal if implanted further than 1mm off bone. Nonunion of the osteotomy occurred in three out of 99 patients (3%).