Introduction. Three-dimensional (3D) morphological understanding of the hip joint, specifically the
Management of ankle arthritis in young patients is challenging. Although ankle arthrodesis gives consistent pain relief, it leads to loss of function and adjacent joint arthritis. Ankle joint distraction (AJD) has been shown to give good outcomes in adults with osteoarthritis or post-traumatic arthritis. The efficacy in children or young adults and those with juvenile idiopathic arthritis is less well evidenced. Clinical notes and radiographs of all patients (n=6) managed with AJD in one tertiary referral centre were retrospectively reviewed. Radiographs were taken pre-surgery, intra-operatively, 1 month following frame removal and at the last follow up, tibiotalar
In this study, we aimed to investigate tibiofemoral and allograft loading parameters after OCA transplantation using tibial plateau shell grafts to characterize the clinically relevant biomechanics that may influence joint kinematics and OCA osseointegration after transplantation. The study was designed to test the hypothesis that there are significant changes in joint loading after tibial plateau OCA transplantation that may require unique post-operative rehabilitation regimens in patients to restore balance in the knee joint. Fresh-frozen cadaveric knees (n=6) were thawed and mounted onto a 6 DOF KUKA robot. Specimens were size matched to +2 mm for the medial-to-lateral width of the medial tibial hemiplateaus. Three specimens served as allograft recipient knees and three served as donor knees. Recipient knees were first tested in their native state and then tested with size-matched medial tibial hemiplateau shell grafts (n=3) prepared from the donor knees using custom-cut tab-in-slot and subchondral drilling techniques. Tekscan sensors were placed in the
Varus malalignment increases the susceptibility of cartilage to mechanical overloading, which stimulates catabolic metabolism to break down the extracellular matrix and lead to osteoarthritis (OA). The altered mechanical axis from the hip, knee to ankle leads to knee joint pain and ensuing cartilage wear and deterioration, which impact millions of the aged population. Stabilization of the remaining damaged cartilage, and prevention of further deterioration, could provide immense clinical utility and prolong joint function. Our previous work showed that high tibial osteotomy (HTO) could shift the mechanical stress from an imbalanced status to a neutral alignment. However, the underlying mechanisms of endogenous cartilage stabilization after HTO remain unclear. We hypothesize that cartilage-resident mesenchymal stem cells (MSCs) dampen damaged cartilage injury and promote endogenous repair in a varus malaligned knee. The goal of this study is to further examine whether HTO-mediated off-loading would affect human cartilage-resident MSCs' anabolic and catabolic metabolism. This study was approved by IACUC at Xi'an Jiaotong University. Patients with medial compartment OA (52.75±6.85 yrs, left knee 18, right knee 20) underwent open-wedge HTO by the same surgeons at one single academic sports medicine center. Clinical data was documented by the Epic HIS between the dates of April 2019 and April 2022 and radiographic images were collected with a minimum of 12 months of follow-up. Medial compartment OA with/without medial meniscus injury patients with unilateral Kellgren /Lawrence grade 3–4 was confirmed by X-ray. All incisions of the lower extremity healed well after the HTO operation without incision infection.
Introduction. Orthopedics is experiencing a significant transformation with the introduction of technologies such as robotics and apps. These, integrated into the post-operative rehabilitation process, promise to improve clinical outcomes, patient satisfaction, and the overall efficiency of the healthcare system. This study examines the impact of an app called Mymobility and intra-operative data collected via the ROSA® robotic system on the functional recovery of patients undergoing robot-assisted knee arthroplasty. Method. The study was conducted at a single center from 2020 to 2023. Data from 436 patients were included, divided into “active” patients (active users of Mymobility) and “non-active” patients. Clinical analyses and satisfaction surveys were carried out on active patients. The intra-operative parameters recorded by ROSA® were correlated with the Patient-Reported Outcome Measures (PROMs) collected via Mymobility. Result. Intra-operative data showed significant correlations with PROMs for the 48 active patients, highlighting the importance of parameters such as medial
Knee joint distraction (KJD) has been associated with clinical and structural improvement and synovial fluid (SF) marker changes. However, structural changes have not yet been shown satisfactorily in regular care, since radiographic acquisition was not fully standardized. AI-based modules have shown great potential to reduce reading time, increase inter-reader agreement and therefore function as a tool for treatment outcome assessment. The objective was to analyse structural changes after KJD in patients using this AI-based measurement method, and relate these changes to clinical outcome and SF markers. 20 knee OA patients (<65 years old) were included in this study. KJD treatment was performed using an external fixation device, providing 5 mm distraction for 6 weeks. SF was aspirated before, during and immediately after treatment. Weight-bearing antero-posterior knee radiographs and WOMAC questionnaires were collected before and ~one year after treatment. Radiographs were analysed with the Knee Osteoarthritis Labelling Assistant (KOALA, IB Lab GmbH, Vienna, Austria), and 10 pre-defined biomarker levels in SF were measured by immunoassay. Radiographic one-year changes were analysed and linear regression was used to calculate associations between changes in standardized
Abstract. Objectives. A promising therapy for early osteoarthritis (OA) is the transplantation of human umbilical cord-derived mesenchymal stromal cells (hUC-MSCs). The synovial fluid (SF) from a pre-clinical ovine model treated with hUC-MSCs has been profiled using proteomics and bioinformatics to elucidate potential mechanisms of therapeutic effect. Methods. Four weeks after a medial meniscus transection surgery, sheep were injected with 10. 7. hUC-MSCs in Phosphate Buffered Saline (PBS) or PBS only (n=7) and sacrificed at 12 weeks. SF was normalised for protein abundance (ProteoMiner. TM. ) and analysed using label-free quantitation proteomics. Bioinformatics analyses (Ingenuity Pathway Analysis (IPA) and STRING) were used to assess differentially regulated functions from the proteomic data. Human orthologues were identified for the ovine proteins using UniProt and DAVID resources and proteins that were ≥±1.3 fold differentially abundant between treatment groups, were included in the bioinformatics analyses. Results. hUC-MSC treated animals demonstrated significantly less
Intra-articular injection is a common way to deliver biologics to joints, but their effectiveness is limited by rapid clearance from the
Abstract. Objectives. While spinal fusion is known to be associated with adjacent disc degeneration, little is known on the role of the facet joints in the process, and whether their altered biomechanics following fusion plays a role in further spinal degeneration. This work aimed to develop a model and method to sequentially measure the effects of spinal fusion on lumbar facet joints through synchronisation of both motion analysis, pressure mapping and mechanical analysis. Methods. Parallel measurements of mature ovine lumbar facet joints (∼8yr old, n=3) were carried out using synchronised load and displacement measurements, motion capture during loading and pressure mapping of the
Introduction and Objective. To estimate the prevalence of acetabular ossifications in the adult population with asymptomatic, morphologically normal hips at CT and to determine whether the presence of labral ossifications is associated with patient-related (sex, age, BMI), or hip-related parameters (joint space width, and cam- and pincer-type femoroacetabular impingement morphotype). Materials and Methods. We prospectively included all patients undergoing thoracoabdominal CT over a 3-month period. After exclusion of patients with a clinical history of hip pathology and/or with signs of osteoarthritis on CT, we included a total of 150 hips from 75 patients. We analyzed the presence and the size of labral ossifications around the acetabular rim. The relationships between the size of labral ossifications and patient- and hip-related parameters were tested using multiple regression analysis. Results. The prevalence of labral ossifications in this population of asymptomatic, non-OA hips was 96% (95%CI=[80.1; 100.0]). The presence of labral ossifications and their size were correlated between right and left hips (Spearman coefficient=0.64 (95%CI=[0.46; 0.79]), p<0.05)). The size of labral ossifications was significantly associated with age (p<0.0001) but not with BMI (p=0.35), gender (p=0.05),
Introduction and Objective. Total shoulder replacement is a common elective procedure offered to patients with end stage arthritis. While most patients experience significant pain relief and improved function within months of surgery, some remain unsatisfied because of residual pain or dissatisfaction with their functional status. Among these patients, when laboratory workup eliminates infection as a possibility, corticosteroid injection (CSI) into the
Summary. Increased lateral ulnotrochlear
Objectives. We have previously investigated an association between the genome copy number variation (CNV) and acetabular dysplasia (AD). Hip osteoarthritis is associated with a genetic polymorphism in the aspartic acid repeat in the N-terminal region of the asporin (ASPN) gene; therefore, the present study aimed to investigate whether the CNV of ASPN is involved in the pathogenesis of AD. Methods. Acetabular coverage of all subjects was evaluated using radiological findings (Sharp angle, centre-edge (CE) angle, acetabular roof obliquity (ARO) angle, and minimum
Summary. In this study we validate that weight-bearing images are needed for accurate polyethylene liner wear measurement in total knee prostheses by measuring the difference in minimum
Intervertebral disc degeneration is a common cause of low-back pain, the musculoskeletal disorder with the largest impact world-wide. The complex disease is however not yet well understood, and no treatment is available. This is somewhat in contrast with osteoarthritis, a subject of more extensive research. Intervertebral disc degeneration may though be a type of osteoarthritis, as other vertebrates have a diarthrodial joint instead of an intervertebral disc. We describe the parallel in view of the anatomy, composition and degeneration of the intervertebral disc and articular joint. Not only different embryonic origin and anatomy suggest significant differences between the intervertebral disc and the synovial joint, but their biomechanical properties also partly differ, as articulation is one of the key properties of a synovial joint and does not occur in the intervertebral disc. However, both tissues provide flexibility and are able to endure compressive loads, and both cell behavior and extracellular matrix appear much the same, mainly existing of chondrocytes, proteoglycans and collagen type II, suggesting that the environment of the cell is more important to its behavior than embryonic origin. Moreover, great similarities are found in the inflammatory cytokines, which are mainly IL-1β and TNF-α, and matrix-degrading factors (i.e. MMPs and ADAMTSs) involved in the cascade of degeneration, resulting in overlapping clinical and radiological features such as loss of
Summary. The dGEMRIC index correlates more strongly with the pattern of radiographic
Introduction. The purpose of this study was to examine if Sugioka's transtrochanteric rotational osteotomy (TRO) of the femoral head could be a valid option in treating idiopathic osteonecrosis of the femoral head. Methods. Thirty-two TROs performed in 29 patients between 1985 and 2006 were studied. Patient age at operation ranged from 16 to 56 years (average, 36 years). Thirteen hips were in women and 19 hips in men. Height was 165 cm and weight 63 kg (Body Mass Index 23) on average. Risk factors were corticosteroid use in 18 hips and excessive alcohol consumption in 15 hips (2 of them had both backgrounds), while neither of them was found with 1 hip. Bilateral hips were affected in 19 patients and 3 of them underwent bilateral TROs sequentially. The femoral head was rotated anteriorly in 26 hips and posteriorly in 6 hips. For fixation of the osteotomy site, large femoral screws had been used till 1995 (Group 1, 9 hips), and since 1996 an AO angle plate or a compression hip screw has been used (Group 2, 13 hips). Since 2003, pre-operative planning was performed more meticulously and the distal part of the joint capsule was cut after osteotomy as described by Atsumi (Group 3, 10 hips). The average follow-up period was 6.5 years (range, 2 to 21 years). Results. The average Japanese Orthopaedic Association hip score was 55 points pre-operatively, 63 points at 1 year, and 61 points at the latest follow-up. With pain increase, re-collapse of the rotated femoral head, fracture of the proximal fragment, nonunion, trochanteric detachment,
Introduction. Anteromedial osteoarthritis of the knee (anteromedial gonarthrosis-AMG) is a common form of knee arthritis. In a clinical setting, knee arthritis has always been assessed by plain radiography in conjunction with pain and function assessments. Whilst this is useful for surgical decision making in bone on bone arthritis, plain radiography gives no insight to the earlier stages of disease. In a recent study 82% of patients with painful arthritis had only partial thickness
Introduction. The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Methods. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the
Acetabular dysplasia was produced in 24 immature white rabbits. A rotational acetabular osteotomy was then carried out and radiological and histological studies of the articular cartilage were made. In the hips which did not undergo osteotomy, radiographs at 26 weeks showed that residual subluxation remained and arthritic changes such as narrowing of the