Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_13 | Pages 1 - 1
1 Jun 2016
Prasad VR Fung M Borowsky K Tolat A Singh B
Full Access

We wished to assess the usefulness of Inspace balloon arthroplasty (IBA), in our Upper limb unit by regular patient reviews prospectively. This prospective study was started adhering to local approval process. Patients were identified in routine clinical practice by three upper limb consultants presenting with pain and disability and diagnosis of cuff tear was established clinically and on MRI. The patients were explained of ‘available’ treatment options and an information leaflet about balloon arthroplasty provided. Patients were seen in 4 weeks, in a dedicated clinic to find out their willingness to participate. Consultant shoulder surgeons carried out all Balloon arthroplasties and where the cuff was reparable or contraindications identified were excluded from study.

All the patients were reviewed by an independent clinician pre-operatively and post operatively using the assessment tools of Oxford Shoulder Scores (OSS), SF12 and VAS at 6 weeks, followed by 3, 6, 12 months and annually after.

We performed a total of 32 IBA procedures. At the latest follow-up we identified that 24 patients have completed 2 years post procedure. Of these patients 1 deceased after 6 months, 3 were lost to follow up one each at 6, 12 and 24 months. Three were revised to reverse TSA. The OSS reflects that the positive difference of 10 in the average scores (24 pre-operative versus 34 at 2 years) noted at one year follow up were maintained at 2 years. Similar observations made analysing at 12 months and 2 years scores for the VAS pain scores of 3 at 2 years compared to pre-operative score of 6 and so were improvements in both physical & mental components of SF12.

Our study observes that the IBA provides a sustainable pain relief and functional improvements over 2 years and may be a suitable alternative in physiologically compromised patients with irreparable RCT.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 576 - 576
1 Dec 2013
Wang C Wong T
Full Access

Background:. Massive rotator cuff tear can cause functional disability due to instability and degenerative changes of the shoulder joint. In patients with massive irreparable rotator cuff tear, tendon transfer is often used as the salvage procedure. Latissimus dorsi and pectoris major transfer are technically demanding procedures and may incur complications. The biceps tendon transfer may provide a biologically superior tissue patch that improves the biomechanics of the shoulder joint in patients with irreparable rotator cuff tear. This study evaluated the functional outcomes of biceps tendon transfer for irreparable rotator cuff tear in 6 patients with two years and longer follow-up. Methods:. Between September 2006 and October 2011, 50 patients with 50 shoulders underwent surgical repair for MRI confirmed rotator cuff tear. Among them, six patients with massive irreparable rotator cuff tear were identified intraoperatively, and underwent proximal biceps tendon transfer to reconstruct the rotator cuff tear. The biceps tendon was tenodesed at the bicipital groove, and the proximal intra-articular portion of the biceps tendon was transected. The biceps graft was fanned out and the distal end fixed to the cancellous trough around the greater tuberosity with suture anchor. The anterior edge was sutured to the subscapularis and the posterior edge to the infraspinatus tendon or supraspinatus if present. Postoperative managements included sling protection and avoidance of strenuous exercises for 6 weeks, and then progressive rehabilitation until recovery. Results:. The evaluation parameters included VAS pain score, UCLA score, Constant score and AHES score, and X-rays of the shoulder. At follow-up of 25.3 ± 25.0 (range 22 to 63) months, the mean VAS pain score decreased from 9.3 ± 0.8 preoperatively to 1.7 ± 1.4 postoperatively (p < 0.001). All patients presented with significant improvements in pain and function of the shoulder for daily activities after surgery, however, only one patient achieved excellent results. There is no correlation of functional outcome with age, gender and body mass index. There was no infection or neurovascular complication. Discussion:. The biceps transfer provides soft tissue coverage of the humeral head, and restores the superior stability of the shoulder joint. The transferred biceps tendon also improves the mechanics and increases the compression force of the humeral head to the glenoid fossa. The results of the current study showed significant pain relief and improvement of shoulder function after biceps tendon transfer for irreparable rotator cuff tear. Conclusion:. Biceps tendon transfer is effective in the management of massive irreparable rotator cuff tear. The procedure is technically accessible with minimal surgical risks


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 265 - 265
1 Mar 2013
Miyoshi N Suenaga N Oizumi N Taniguchi N Ito H
Full Access

Introduction. In recently, Reverse shoulder arthroplasty (RSA) in patients with irreparable rotator cuff tear has been worldwidely performed. Many studies on RSA reported a good improvement in flexion of the sholulder, however, no improvement in external rotation (ER)and internal rotation motion (IR). Additionally, RSA has some risks to perform especially in younger patients, because high rates of complications such as deltoid stretching and loosening, infection, neurologic injury, dislocation, acromial fracture, and breakage of the prosthesis after long-term use were reported. Favard et al noted a 72% survival with a Constant-Murley score of <30 at 10 years with a marked break occurring at 8 years. Boileau et al noted caution is required, as such patients are often younger, and informed consent must obviously cover the high complication rate in this group, as well as the unknown longer-term outcome. Its use should be limited to elderly patients, arguably those aged over 70 years, with poor function and severe pain related to cuff deficiency. We developed a novel strategy in 2001, in which we used the humeral head to close the cuff defect and move the center of rotation medially and distally to increase the lever arm of the deltoid muscle. Aim. The aim of this study was to investigate clinical outcome of our strategy for younger patients with an irreparable rotator cuff tear. Materials and Methods. Eighteen shoulders (9 of male patients, 9 of female patients) of patients under 70 years old with an irreparable cuff tears and who were treated with Humeral Head Replacement (HHR) and cuff reconstruction were followed up for more than 12 months. The average age was 63.9 years (range, 58–69 years). The average follow-up period was 27.3 months (range, 12–76 months). The cuff defect was successfully closed in 8 shoulders, whereas 8 shoulders required a Latissimus Dorsi transfer; one other shoulder required a Pectralis Major transfer, and one required both Latissimus dorsi and pectoralis major transfers. Range of motion (flexion, ER), the shoulder score of Japanese Orthopaedic Association (JOA score), and complications were evaluated. Results. Shoulder pain decreased in all patients after surgery. JOA score was improved from 41.1 to 82.6 points after surgery, Flexion motion improved from 72.5 to 145.6 degrees postoperatively and ER increased from 17.5 to 37.8 degrees postoperatively. There were no complications. Conclusion. In our study, HHR using the small head of the humerus and cuff reconstruction for patients under 70 years old with an irreparable rotator cuff tear yielded favorable results as compared to RSA, especially in terms of the ER Furthermore, the advantages of our strategy is able to keep bone stock of the glenoid after surgery. If revision surgery is required, RSA can be performed. Since the patients included in our study were relatively active, long-term follow-up will be required to assess their progress


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 85 - 85
1 Dec 2022
Fleet C McNeil D Trenholm JAI Johnson JA Athwal G
Full Access

Massive irreparable rotator cuff tears often lead to superior migration of the humeral head, which can markedly impair glenohumeral kinematics and function. Although treatments currently exist for treating such pathology, no clear choice exists for the middle-aged patient demographic. Therefore, a metallic subacromial implant was developed for the purpose of restoring normal glenohumeral kinematics and function. The objective of this study was to determine this implant's ability in restoring normal humeral head position. It was hypothesized that (1) the implant would restore near normal humeral head position and (2) the implant shape could be optimized to improve restoration of the normal humeral head position. A titanium implant was designed and 3D printed. It consisted of four design variables that varied in both implant thickness (5mm and 8mm) and curvature of the humeral articulating surface (high constraint and low constraint. To assess these different designs, these implants were sequentially assessed in a cadaver-based biomechanical testing protocol. Eight cadaver specimens (64 ± 13 years old) were loaded at 0, 30, and 60 degrees of glenohumeral abduction using a previously developed shoulder simulator. An 80N load was equally distributed across all three deltoid heads while a 10N load was applied to each rotator cuff muscle. Testing states included a fully intact rotator cuff state, a posterosuperior massive rotator cuff tear state (cuff deficient state), and the four implant designs. An optical tracking system (Northern Digital, Ontario, Canada) was used to record the translation of the humeral head relative to the glenoid in both superior-inferior and anterior-posterior directions. Superior-Inferior Translation. The creation of a posterosuperior massive rotator cuff tear resulted in significant superior translation of the humeral head relative to the intact cuff state (P=0.016). No significant differences were observed between each implant design and the intact cuff state as all implants decreased the superior migration of the humeral head that was observed in the cuff deficient state. On average, the 5mm low and high constraint implant models were most effective at restoring normal humeral head position to that of the intact cuff state (-1.3 ± 2.0mm, P=0.223; and −1.5 ± 2.3mm, P=0.928 respectively). Anterior-Posterior Translation. No significant differences were observed across all test states for anterior-posterior translation of the humeral head. The cuff deficient on average resulted in posterior translation of the humeral head, however, this was not statistically significant (P=0.128). Both low and high constraint implant designs were found to be most effective at restoring humeral head position to that of the intact cuff state, on average resulting in a small anterior offset (5mm high constraint: 2.0 ± 4.7mm, P=1.000; 8mm high constraint: 1.6 ± 4.9mm, P=1.000). The 5mm high constraint implant was most effective in restoring normal humeral head position in both the superior-inferior and anterior-posterior directions. The results from this study suggest the implant may be an effective treatment for restoring normal glenohumeral kinematics and function in patients with massive irreparable rotator cuff tears. Future studies are needed to address the mechanical efficiency related to arm abduction which is a significant issue related to patient outcomes


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 283 - 283
1 Dec 2013
De Caro F De Biase C Ziveri G Delcogliano M Borroni M Castagna A
Full Access

Introduction:. Reverse shoulder arthroplasty (RSA) is a reasonable treatment modality in patients with Cuff Tear Arthropaty and massive irreparable cuff tears. RSA has been shown to increase patient function and decrease pain. The aim of this study is to evaluate the clinical and radiographic results of a 44 polyethylene glenosphere. Methods:. Since 2008 we treated 88 patients with cuff tear arthropaty and irreparable massive cuff tear, using an RSA. We selected 80 patients with minimum FU of 24 months in which we used an implant with polyethylene glenosphere and metal humeral insert. Size of the glenosphere used was 44. All patients were assessed with the Constant score and with VAS. The shoulder ROM was measured preoperatively and postoperatively. Results:. Average age of the patients was 71 years old. Average duration of FU was 34 months. All measures improved significantly (p < 0.0001). The mean Constant improved from 15.6 to 60.2. VAS improved from 6 to 2,5. Forward flexion increased from 40 ° to 126,4 °, abduction from 41 ° to 103 °, external rotation from 15.1 to 17.3 and internal rotation increased by two level. We report 22 cases of scapular notching without clinical influence and without implant mobilization. Conclusion:. This is the first report of the use of a polyethylene glenosphere. Data from this study suggest that RSA with a polyethylene glenosphere may be a viable treatment for patients with glenohumeral arthritis and a massive rotator cuff tear. Future studies will be necessary to determine the longevity of the implant and whether it will provide continued improvement in function


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 17 - 17
1 Apr 2013
Iqbal HJ Williams G Redfern TR
Full Access

Introduction. Reverse total shoulder replacement is performed for the treatment of rotator cuff arthropathy, massive irreparable cuff tears and failed shoulder hemiarthroplasty with irreparable rotator cuff tears. The aim of this study was to assess the clinical and radiological outcome of single surgeon series of Equinoxe® reverse total shoulder replacement at a district general hospital. Materials/Methods. Consecutive patients who underwent Equinoxe® reverse total shoulder replacement at our unit from Jun 2008 to Dec 2010 were retrospectively reviewed. Indications for surgery, complications and radiological outcomes were assessed. Oxford shoulder score was used to assess the functional outcome. Results. Between Jun 2008 and Dec 2012, forty-one reverse total shoulder replacements were performed by the senior author in 37 patients. Of these, Equinoxe® prostheses were used in 27 operations (26 patients). These included 22 female and 4 male patients. Cuff arthropathy was the commonest preoperative diagnosis (23 patients), followed by proximal humeral fracture non-union (2 patients), failed hemiarthroplasty (one patient) and failed resurfacing (one patient). The mean follow up was 10 months (3 to 17 months). At the time of the study, three patients had died due to unrelated causes, two were not contactable and the remaining 21 patients were analysed. The mean oxford shoulder score was 35.8 (21–48). Nineteen patients (90.5%) graded their outcome a good to excellent while 2 patients (9.5%) graded as poor. Seventeen patients (81%) expressed that they would recommend this operation. One patient (4.7%) had infection and another had dislocation. Overall, there were 3 reoperations (14.3%); first washout, second change of humeral tray and third excision of lateral end of clavicle and reattachment of deltoid. Two patients (9.5%) had small glenoid notching. There was no loosening, neurovascular injury or postoperative haematoma. Conclusion. Early outcome of Equinoxe reverse shoulder replacement is promising. Longer follow-up is required to further assess the outcome


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 124 - 124
1 Jul 2020
Woodmass J Wagner E Borque K Chang M Welp K Warner J
Full Access

Chronic massive irreparable rotator cuff tears represent a treatment challenge and the optimal surgical technique remains controversial. Superior capsular reconstruction (SCR) has been proposed as a means to provide superior stability to the glenohumeral joint, thus facilitating restoration of shoulder function. However, despite the growing use of SCR there is a paucity of data evaluating the outcomes when performed using a dermal allograft. The purpose of this study was to (1) report the overall survival rate (reoperation and clinical failure) of SCR (2) evaluate for pre-operative factors predicting reoperation and clinical failure. From January 1, 2015 to November 31, 2017, 65 patients were diagnosed with irreparable rotator cuff tears and consented for a superior capsular reconstruction. These surgeries were performed by 6 surgeons, all fellowship trained in either sports or shoulder and elbow fellowships. Outcomes were graded as excellent, satisfactory, or unsatisfactory using the modified Neer scale. An unsatisfactory result was defined as a clinical “failure”. The Kaplan-Meier survival models were created to analyze reoperation-free and failure-free survival for the entire group. The reconstruction was performed using a dermal allograft. There were 31 patients excluded due to insufficient follow-up (< 6 months), leaving 34 included in this study. The mean follow-up was 12 months (range, 6–23). The average number of prior surgeries was 0.91 (range, 0–5), with 52.9% of patients receiving a prior rotator cuff repair and 38.2% of patients with a prior non-rotator cuff arthroscopy procedure. The one and two-year survival-free of surgery was 64% and 44% and the one and two-year survival free of failure was 34% and 16% following SCR, respectively. For the patients that underwent a reoperation, 62.5% (n= 5/8) underwent reverse shoulder replacements, 25% (n= 2/8) latissimus dorsi tendon transfers, and 12.5% (n= 1/8) a diagnostic arthroscopy. The average period between the primary and revision surgery was 10.2 months (range, 2.1–18.5). All but two patients (75%, n= 6/8) had at least one surgery prior to the SCR. There were 14/34 (41.2%) patients who experienced pain, weakness, and restricted range of motion. These patients were defined as clinical failures with an unsatisfactory grading on Neer's criteria. Previous surgery predicted reoperation (80% vs 43%, p = 0.03). Female gender predicted clinical failure (100% vs 43%, p < 0 .01). Superior Capsule Reconstruction performed for large to massive rotator cuff tears has a high rate of persistent pain and limited function leading to clinical failure in 65% (n= 22/34) of patients. The rate of failure is increased in revision cases, female gender and increased Goutallier fatty infiltration of the infraspinatus. Narrowed indications are recommended given the surgical complexity and high rate of early failure


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 51 - 51
1 Jul 2020
Vachhani K Whyne C Nam D Wong J Chou J Paul R
Full Access

Rotator cuff tears are the most common cause of shoulder disability, affecting 10% of the population under 60 and 40% of those aged 70 and above. Massive irreparable rotator cuff tears account for 30% of all tears and their management continues to be an orthopaedic challenge. Traditional surgical techniques, that is, tendon transfers are performed to restore shoulder motion, however, they result in varying outcomes of stability and complications. Superior capsular reconstruction (SCR) is a novel technique that has shown promise in restoring shoulder function, albeit in limited studies. To date, there has been no biomechanical comparison between these techniques. This study aims to compare three surgical techniques (SCR, latissimus dorsi tendon transfer and lower trapezius tendon transfer) for irreparable rotator cuff tears with respect to intact cuff control using a clinically relevant biomechanical outcome of rotational motion. Eight fresh-frozen shoulder specimens with intact rotator cuffs were tested. After dissection of subcutaneous tissue and muscles, each specimen was mounted on a custom shoulder testing apparatus and physiologic loads were applied using a pulley setup. Under 2.2 Nm torque loading maximum internal and external rotation was measured at 0 and 60 degrees of glenohumeral abduction. Repeat testing was conducted after the creation of the cuff tear and subsequent to the three repair techniques. Repeated measures analysis with paired t-test comparisons using Sidak correction was performed to compare the rotational range of motion following each repair technique with respect to each specimen's intact control. P-values of 0.05 were considered significant. At 0° abduction, internal rotation increased after the tear (intact: 39.6 ± 13.6° vs. tear: 80.5 ± 47.7°, p=0.019). Internal rotation was higher following SCR (52.7 ± 12.9°, intact - SCR 95% CI: −25.28°,-0.95°, p=0.034), trapezius transfer (74.2 ± 25.3°, intact – trapezius transfer: 95% CI: −71.1°, 1.81°, p=0.064), and latissimus transfer (83.5 ± 52.1°, intact – latissimus transfer: 95% CI: −118.3°, 30.5°, p=0.400) than in intact controls. However, internal rotation post SCR yielded the narrowest estimate range close to intact controls. At 60° abduction, internal rotation increased after the tear (intact: 38.7 ± 14.4° vs. tear: 49.5 ± 13°, p=0.005). Internal rotation post SCR did not differ significantly from intact controls (SCR: 49.3 ± 10.1°, intact – SCR: 95% CI: −28°, 6.91°, p=0.38). Trapezius transfer showed a trend toward significantly higher internal rotation (65.7 ± 21.1°, intact – trapezius transfer: 95% CI: −55.7°, 1.7°, p=0.067), while latissimus transfer yielded widely variable rotation angle (65.7 ± 38°, intact – latissimus transfer: 95% CI: −85.9°, 31.9°, p=0.68). There were no significant differences in external rotation for any technique at 0° or 60° abduction. Preliminary evaluation in this cadaveric biomechanical study provides positive evidence in support of use of SCR as a less morbid surgical option than tendon transfers. The cadaveric nature of this study limits the understanding of the motion to post-operative timepoint and the results herein are relevant for otherwise normal shoulders only. Further clinical evaluation is warranted to understand the long-term outcomes related to shoulder function and stability post SCR


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 88 - 88
1 Jan 2016
Nishinaka N Suzuki K Matsuhisa T Uehara T Nagai S Tsutsui H
Full Access

Purpose. Chronic massive rotator cuff tears are challenging to repair completely because of the development of tendon retraction with inelasticity, muscle atrophy and fatty infiltration. The objective of this study was to investigate the clinical outcome and MRI findings after arthroscopic superior capsule reconstruction (ASCR) for symptomatic irreparable rotator cuff tears. Methods. From 2011 to 2013, 12 shoulders in 12 consecutive patients (mean, 70.8 years) with irreparable massive rotator cuff tears underwent ASCR using fascia lata. We used suture anchors to attach the graft medially to the glenoid superior tubercle and laterally to the greater tuberosity as same technique by Mihata et al. We added side-to-side sutures between the graft and infraspinatus tendon and between the graft and residual anterior supraspinatus/subscapularis tendon to improve force coupling. Physical examination, clinical rating system, and magnetic resonance imaging (MRI) were performed before surgery; at 6 and 12 months after surgery; and 6 months thereafter. Average follow-up was 19.1 months (12 to 28 months) after surgery. We assessed patients preoperatively by using the scoring systems of the shoulder index of the American Shoulder and Elbow Surgeons (ASES), the Japanese Orthopaedic Association, and the University of California, Los Angeles. Results. Mean active elevation increased from 59° to 111° significantly and external rotation increased from 28 to 33. The average preoperative scores were 16.0 points by ASES, 48.0 points by JOA, and 10.8 points by UCLA. Average clinical outcome scores all improved significantly after ASCR at the final follow-up (ASES, 73.3 points; JOA, 73.7 points; UCLA, 22.7 points). There was surgical complication as infection. Although infection was controlled by arthroscopic irrigation, the transplanted tendon was absorbed, and preoperative conditions did not functionally improve. Five patients had graft tear during follow-up. Postoperative active range of motion in the healed patients was significantly greater than in the unhealed patients who had graft tears. Conclusions. ASCR restored superior glenohumeral stability and function of the shoulder joint with irreparable rotator cuff tears compared to preoperative function in the cases without postoperative complications. However ratio of graft tears were 50% and clinical results of these cases were not improved sufficiently


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 168 - 168
1 Sep 2012
Wong IH Burns J Snyder S
Full Access

Purpose. Management of massive, degenerative, and irreparable rotator cuff tears is challenging. Excessive re-tear rates and poor clinical outcome after standard repair have led to alternative methods of treatment. Tendon transfers and shoulder arthroplasty have had mixed results; both are invasive procedures with high potential morbidity. We began performing rotator cuff augmentation and replacement using GraftJacket allograft acellular human dermal matrix as a biologic minimally invasive alternative in this difficult population almost 6 years ago. This article highlights our preferred arthroscopic technique and early results. Method. From January 2004 to June 2007, 45 patients (36 men, 9 women) with massive rotator cuff tears were treated arthroscopically with the GraftJacket allograft. All patients completed a preoperative University of California, Los Angeles (UCLA) score. Follow-up was a minimum of 2 years (range, 24–68 months) and patients completed UCLA, Western Ontario Rotator Cuff (WORC), and American Shoulder and Elbow Surgeons (ASES) scores. Results. Analysis was performed using the 3 validated outcomes measurement scores. The mean UCLA score increased from 18.4 preoperatively to 27.5 postoperatively (P < .000). The average WORC score was 75.2, and the ASES score was 84.1 at the final follow-up. Conclusion. Evidence-based data to outline an algorithm for management of irreparable rotator cuff tears is being developed. We documented significant clinical improvement with arthroscopic rotator cuff reconstruction using the GraftJacket allograft acellular human dermal matrix. The procedure is safe and associated with high patient satisfaction, without the morbidity of tendon transfer or arthroplasty. For those few cases where further surgery is required, no bridges are burned. The early success of this procedure warrants further study with more patients, longer follow-up, and higher levels of evidence-based investigation


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 225 - 225
1 Dec 2013
Alta T Morin-Salvo N Bessiere C Moineau G Boileau P
Full Access

Introduction:. Lateralization of reversed shoulder arthroplasty provides improvement in range of motion and decreases inferior scapular notching. The purpose of this study was to verify if the autologous cancelous bone graft harvested from the humeral head does heal constantly in a large cohort of patients followed for a long time. Methods:. Cohort of 92 consecutive patients operated between 2006 and 2010 with a BIORSA for definitive shoulder pseudoparalysis, secondary to cuff tear arthropathy (CTA) or massive, irreparable cuff tear (MCT). The autogenous cancelous graft was harvested from humeral head in all cases. Eight patients were lost for follow up, and four died before 2 years. The remaining 80 patients underwent clinical, radiographic and CT assessment at a minimum FU of 24 months. Mean age was 73 years. Three independent observers evaluated notching, partial or total glenoid or humeral loosening and viability of the graft. Constant-Murley score, range of motion and subjective shoulder value (SSV) were recorded. The mean follow up was 39 months (range 24–74 months). Results:. The bone graft did healed completely in 96% of the cases (77/80); the thickness of the graft remained stable through the years. There were two cases of glenoid loosening: one nonunion of the graft at the scapular side was due to an important superior tilt of the glenosphere; one failure of fixation at the baseplate side was related to a low-grade infection. Another patient had a partial radiolucent line between graft and native glenoid located only above the central peg. No other radiolucent line around peg, screws or baseplate was found. Inferior scapula notching was observed in 19% of the cases (mainly grade 1 and 2). Each parameters of Constant score improved, and the mean SSV increased from 27% to 78%. Conclusion:. This study shows that: (1) autologous cancellous bone graft, harvested from the humeral head, does heal to the native glenoid despite the advanced age of the patients; and (2) BIO-RSA allows improvement of shoulder function (mobility, pain, strength, subjective value) with a low rate of scapular notching


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 9 - 9
1 Nov 2019
Siddiqi RA Byrne P Mukherjee A Hafiz N
Full Access

The management of patients with massive irreparable rotator cuff tears (RCT) has traditionally proved challenging. This prospective study was undertaken with the aim to assess the overall functional outcome following the use of human dermal allograft in the reconstruction of massive irreparable RCT. 15 patients were included in the study, having a median age of 63 years. All patients underwent open reconstruction of massive irreparable RCT. None of the selected patients had evidence of significant gleno-humeral arthritis. All patients were evaluated pre- and post- operatively by the treating surgeon, and followed up for 12 months. The same physiotherapy protocol was prescribed for all patients. Initial and follow-up assessments were done at regular intervals using the Oxford and quick-DASH scoring systems. A very high patient satisfaction rate, with substantial improvement in pain and function was noted. There was substantial improvement in Oxford shoulder score from a mean of 23.3 to 8.7 (p<0.01), and a similar improvement in mean quick-DASH score from 50.3 to 23.0 (p<0.01). Of the 15 patients, 11 had an improvement of >10 in Oxford score, with these reporting a score of <10 after 12 months. None of the patients had any significant complications because of the surgery, and none had a deterioration in Oxford score from their pre-operative status. We found that Human dermal allograft is a very effective tool in the repair of massive irreparable RCT, with excellent follow-up results after one year


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 20 - 20
1 Nov 2016
Gobezie R
Full Access

Reverse total shoulder arthroplasty (RTSA) was designed to treat the cuff-deficient shoulder with arthritis and irreparable rotator cuff tears of the supraspinatus and infraspinatus tendons. The results of RTSA in this patient population have been very good and reliable in the majority of cases. However, it has also been reported that patients whose rotator cuff tear involves the supraspinatus, infraspinatus and teres minor and who demonstrate a ‘horn-blower's sign’ do very poorly if a muscle transfer is not performed to improve external rotation in these shoulders in abduction. The loss of the teres minor in these patients results in grave difficulty for the patient attempting to perform their activities of daily living even if they can obtain reasonable good forward flexion. The muscle transfer that is most commonly used for these select patients is a latissmus dorsi tendon transfer in conjunction with RTSA. The purpose of this talk is to review the pathology of this problem and review the technique for its surgical treatment


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 2 - 2
1 Oct 2015
Prasad V Singh B Borowsky K Tolat A Kurta I
Full Access

Aim. To determine the benefit of dissolvable Balloon Arthroplasy in managing patients with massive irreparable rotator cuff tears (RCT). Methods. This is prospective pilot study carried out adhering to the local approval process. Patients having massive cuff tear with pain or functional limitation were seen by consultants and MRI confirmed the diagnosis. The patients were explained of ‘all available’ treatment options and information leaflet about the new procedure balloon arthroplasty, provided. Patients were seen after 4 weeks in a dedicated clinic to find out if they were willing to participate. Patients were seen by a physiotherapist pre and post-operatively at 6 weeks then at 3, 6 and 12months in addition to medical follow-ups, using VAS, Oxford Shoulder, Constant and SF36 scores. All procedures were carried out by consultant shoulder surgeons and where the cuff was reparable or contraindications identified were excluded. Results. Of the 25 recruited 4 were lost for follow up. 17 of the remaining 21 completed 12 month follow up, and the remaining completed their 6 month follow up. Male to female ratio was 2:1 and no surgical complications were noted. Two patients required an inverse shoulder arthroplasty. Improvements were noted in the SF36, VAS and OSS. Conclusion. The balloon arthroplasty seems to offer benefit for a group of patients who are unfit or not keen on major surgery to offer pain relief possibly function. Recommendations cannot be made due to the study but suggest a multicentre study


Massive irreparable rotator cuff tears (MIRCTs) represent a difficult situation especially in painful and pseudoparalytic patients. A new technique, consisting of an arthroscopic implantation of an inflatable biodegradable “balloon”, serving as a temporary subacromial spacer, has been introduced recently for MIRCTs. The purpose of this paper is: 1) to present the efficacy and safety results of patients treated with the balloon; 2) to show that these results are maintained over time, after balloon degradation; 3) to compare these results to published results of other procedures available for MIRCTs. This paper presents the first group of 22 patients (females/males 13/8, one bilateral), treated in a single-surgeon, prospective and on-going series of 97 shoulders operated with the balloon, since September 2010. The mean age is 69.3 (52–86) and the average follow-up 52.5 months. The balloon is inserted arthroscopically and inflated with saline. The procedure is simple with a short operative time (10–20 min). It can also supplement partial repairs, especially of the subscapularis, as well as repairable massive tears with bad tissue quality. The balloon is not used in severe cuff tear arthropathy or complete insufficiency of the external rotators. Final outcome scores, Constant (CS) and UCLA scores are obtained at least three years after complete balloon degradation (which occurs within 12 months), and are also compared to those of other treatments available for MIRCTs. No device related safety issues were observed in this group. Good results, including rapid pain relief and restoration of active motion, which maintained over time, are obtained in 85% of the patients. The CS has improved significantly (average preop/postop: pain 2.9/12.7; ADL 6.8/17.4; ROM 22.8/36.6; strength 3.1/5.6; TOTAL 35.8/72.3; NORMATIVE 42.7/86.4). The UCLA score has also improved significantly (preop/postop: pain 1.9/8.6; function 3.9/8.6; active flexion 3.5/4.5; strength in flexion 2.4/3.4; satisfaction 0/4.5; TOTAL 11.2/29.8). Pseudoparalysis is reversed (average preop/postop flexion 86°/156.8°). The CS and UCLA score for the balloon are superior compared to published results of debridement, biceps tenotomy/tenodesis, partial repair, tuberoplasty and latissimus dorsi transfer. CS (86.4/63.8), CS pain (12.7/11.9) and flexion (156.8/128.0) are also better for the balloon compared to the reverse prosthesis. The balloon is indicated for MIRCTs, as well as reparable massive tears with a high risk of retear. The implantation is a straightforward and short procedure, which has excellent safety profile and positive effect on painful MIRCTs including pseudoparalysis. The balloon provides significant improvement in the CS and UCLA score that persists way beyond its degradation. The balloon patients' shoulder function is superior to the other available treatment options. Additional studies are needed to further confirm the effectiveness of the balloon as a first line treatment for MIRCTs


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 115 - 115
1 May 2016
Walker D Kinney A Wright T Banks S
Full Access

Reverse total shoulder arthroplasty (RTSA) is an increasingly common treatment for osteoarthritic shoulders with irreparable rotator cuff tears. Although very successful in alleviating pain and restoring some function, there is little objective information relating geometric changes imposed by the reverse shoulder and arm function, particularly the moment generating capacity of the shoulder muscles. Recent modeling studies of reverse shoulders have shown significant variation in deltoid muscle moment arms over a typical range of humeral offset locations in shoulders with RTSA. The goal of this study was to investigate the sensitivity of muscle moment arms as a function of varying the joint center and humeral offset in three representative RTSA subjects that spanned the anatomical range from our previous study cohort. We hypothesized there may exist a more beneficial joint implant placement, measured by muscle moment arms, compared to the actual surgical implant configuration. A 12 degree of freedom, subject-specific model was used to represent the shoulders of three patients with RTSA for whom fluoroscopic measurements of scapular and humeral kinematics during abduction had been obtained. The computer model used subject-specific in vivo abduction kinematics and systematically varied humeral offset locations over 1521 different perturbations from the surgical placement to determine moment arms for the anterior, lateral and posterior aspects of the deltoid muscle. The humeral offset was varied from its surgical position ±4 mm in the anterior/posterior direction, ±12mm in the medial/lateral direction, and −10 mm to 14 mm in the superior/inferior direction. The anterior deltoid moment arm varied up to 20 mm with humeral offset and center of rotation variations, primarily in the medial/lateral and superior/inferior directions. Similarly, the lateral deltoid moment arm demonstrated variations up to 20 mm, primarily with humeral offset changes in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15mm, primarily in early abduction, and was most sensitive to changes of the humeral offset in the superior/inferior direction. The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for existing RTSA subjects. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to humeral offset changes early in the abduction arc. Moment arm changes of 15–20 mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moment arms through surgical placement of the joint center of rotation and humeral stem. Computational models of the shoulder may help surgeons optimize subject-specific placement of RTSA implants to provide the best possible muscle function, and assist implant designers to configure devices for the best overall performance


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 106 - 106
1 Jan 2016
Walker D Kinney A Struk A Fregly B Wright T Banks S
Full Access

Reverse total shoulder arthroplasty (RTSA) is an increasingly common treatment for osteoarthritic shoulders with irreparable rotator cuff tears. Although very successful in alleviating pain and restoring some function there is little objective information relating geometric changes imposed by the reverse shoulder and the moment generating capacity of the shoulder muscles. Recent modeling studies of reverse shoulders have shown significant variation in deltoid muscle moment arms over varied joint centers for shoulders with RTSA. The goal of this study was to investigate the sensitivity of muscle moment arms as a function of varying the joint center in one representative RTSA subject. We hypothesized there may exist a more beneficial joint implant placement, measured by muscle moment arms, compared to the actual surgical implant placement. A 12 degree of freedom, subject-specific model was used to represent the shoulder of a patient with RTSA for whom fluoroscopic measurements of scapular and humeral kinematics during abduction had been obtained. The computer model used these abduction kinematics and systematically varied joint center locations over 1521 different perturbations from the surgical placement to determine moment arms for the anterior, lateral and posterior aspects of the deltoid muscle. The joint center was varied from its surgical position ±4 mm in the anterior/posterior direction, 0–24 mm in the medial/lateral direction, and −10 mm to 14 mm in the superior/inferior direction. The anterior deltoid moment arm varied up to 16mm with center of rotations variations, primarily in the medial/lateral and superior/inferior directions (Figure 2, Table 1(Figure 1)). Similarly, the lateral deltoid moment arm demonstrated variations up to 13 mm, primarily with joint center changes in the anterior/posterior and superior/inferior directions. The posterior deltoid moment arm varied up to 10mm, primarily in early abduction, and was most sensitive to changes of the joint center in demonstrated a sensitivity of 6 mm corresponding to variations in the superior/inferior directions (Figure 2). The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for an existing RTSA subject. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to joint center changes early in the abduction arc. Moment arm changes of 10–16mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moments arms through surgical placement of the joint center of rotation. Computational models of the shoulder may help surgeons optimize subject-specific placement of RTSA implants to provide the best possible muscle function, and assist implant designers to configure devices for the best overall performance


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 3 - 3
1 Mar 2013
Alizadehkhaiyat O Kyriakos A Williams A Frostick S Al Mandhari A
Full Access

BACKGROUND. Reverse total shoulder arthroplasty (RTSA) provides an alternative to standard total shoulder arthroplasty in the treatment of selected complex shoulder problems including failed shoulder replacements. The purpose of this report is to present outcome of RTSA using Comprehensive Reverse System (CRS) as either primary or revision treatment choice. PATIENTS AND MATERIALS. Between September 2010 and April 2012, 54 patients (36 females, 18 males) with the mean age of 68.4 (±10) underwent RTSA-CRS. In 27 patients RTSA-CRS was performed as a revision due to failed previous arthroplasty. Primary underlying conditions included AVN (2), massive irreparable rotator cuff tear (2), primary osteoarthritis (7), post-traumatic osteoarthritis (2), rheumatoid arthritis (6), and rotator cuff arthropathy (8). It was not possible to complete the operation in 6 patients (4 revisions group 2 AVN cases) due to substantial glenoid erosion. Preoperative CT scan was performed in 50% of patients to assess the bony stock of the glenoid. In some patients ultrasound and MRI were performed to acquire additional information. A total of 46 patients were followed-up by means of antroposterior and axial plain X-rays, pain and satisfaction level (VAS/0–10), stiffness, Constant Score, Oxford Shoulder Score, SF-12 (Physical and mental Subscales), and range of movement for a mean duration of 6.5 months (±4.2). RESULTS. The table presents the pre- and postoperative outcome variables for both primary and revision RTSA-CRS groups. The majority of outcome measures indicated a considerable improvement in both groups during the short term follow-up. Significant correlations were noted in-between some key outcome variables. However; due to the short period of follow-up and continuity of collecting data, we intend to produce a more realistic picture of the results s and outcome of the RTSA-CRS in coming years. COMPLICATIONS. There was no vascular complication. Disassociation of glenosphere from the base-plate happened in one patient 8 weeks post-op due to technical mistake, this was repaired later with a satisfactory outcome. One case had enormous hematoma formation 72 hours post-op due to anticoagulants administration leading to second stage evacuation and increased stiffness of shoulder. One patient sustained deltoid partial rupture due to recurrent falls and managed by conservatively. Another patient sustained a type C periprosthetic fracture and was later revised to custom-made stem prosthesis. CONCLUSION. The results of this short-term report indicate a satisfactory and acceptable outcome for RTSA-CRS as reflected in the assessment tools in both primary and revision cases, however with superior results in the primary group. Long-term follow-up is essential to have a more rational assessment of the clinical outcome as well as associated complications