Aims. The primary aim of this study was to identify independent predictors associated with nonunion and delayed union of tibial diaphyseal fractures treated with
Aims. The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and
Aims. The purpose of the study was to investigate whether closed intramedullary
(IM) nailing with percutaneous cement augmentation is better than
conventional closed nailing at relieving pain and suppressing tumours
in patients with metastases of the femur and humerus. Patients and Methods. A total of 43 patients (27 men, 16 women, mean age 63.7 years,
standard deviation (. sd. ) 12.2; 21 to 84) underwent closed
IM nailing with cement augmentation for long bone metastases. A
further 27 patients, who underwent conventional closed
Aims. The primary aim of this study was to compare surgical methods (sliding hip screw (SHS) vs
Aims. The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality. Patients and Methods. Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors. Results. The use of short and long
We investigated a new intramedullary locking
nail that allows the distal interlocking screws to be locked to
the nail. We compared fixation using this new implant with fixation
using either a conventional nail or a locking plate in a laboratory
simulation of an osteoporotic fracture of the distal femur. A total
of 15 human cadaver femora were used to simulate an AO 33-A3 fracture
pattern. Paired specimens compared fixation using either a locking
or non-locking retrograde nail, and using either a locking retrograde
nail or a locking plate. The constructs underwent cyclical loading
to simulate single-leg stance up to 125 000 cycles. Axial and torsional
stiffness and displacement, cycles to failure and modes of failure
were recorded for each specimen. When compared with locking plate
constructs, locking nail constructs had significantly longer mean
fatigue life (75 800 cycles ( The new locking retrograde femoral nail showed better stiffness
and fatigue life than locking plates, and superior fatigue life
to non-locking nails, which may be advantageous in elderly patients. Cite this article:
Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an
Freehand distal interlocking of
Aims. Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture. Methods. This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36)
Introduction. IM (Intra Medullary) nail fixation is the standard treatment for diaphyseal femur fractures and also for certain types of proximal and distal femur fractures. Despite the advances in the tribology for the same, cases of failed
Many pre-clinical models of atrophic non-union do not reflect the clinical scenario, some create a critical size defect, or involve cauterization of the tissue which is uncommonly seen in patients. Atrophic non-union is usually developed following high energy trauma leading to periosteal stripping. The most recent reliable model with these aspects involves creating a non-critical gap of 1mm with periosteal and endosteal stripping. However, this method uses an external fixator for fracture fixation, whereas
Aim. The treatment of fracture-related infections (FRI) focuses on obtaining fracture healing and eradicating infection to prevent osteomyelitis. Treatment guidelines include removal, exchange, or retention of the implants used according to the stability of the fracture and the time from the infection. Infection of a fracture in the process of healing with a stable fixation may be treated with implant retention, debridement, and antibiotics. Nonetheless, the retention of an
Aims. This study aims to describe a new method that may be used as a supplement to evaluate humeral rotational alignment during
Unstable distal tibia fractures are challenging injuries requiring surgical treatment.
Freehand distal interlocking of
Aims. Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this,
Aims. Using tibial shaft fracture participants from a large, multicentre randomized controlled trial, we investigated if patient and surgical factors were associated with health-related quality of life (HRQoL) at one year post-surgery. Methods. The Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) trial examined adults with an open or closed tibial shaft fracture who were treated with either reamed or unreamed
Objectives. The purpose of this study was to compare the results and complications of tibial lengthening over an
Aims. A lack of supporting clinical studies have been published to determine the ideal length of
Introduction. Femoral-shortening osteotomy for the treatment of leg length discrepancy is demanding technique. Many surgical technique and orthopaedic devises have been suggested to perform this procedure. Herein, we describe modified femoral shortening osteotomy over a nail, using a percutaneous multiple drill-hole osteotomy technique. Materials and Methods. We operated on six patients with LLD. Mean femoral shortening was 4.2 cm. Osteotomy was performed using a multiple drill-hole technique, and bone was stabilized using an