Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 65 - 65
1 Nov 2021
Awadallah M Ong J Kumar N Rajata P Parker M
Full Access

Introduction and Objective. Dislocation of a hip hemiarthroplasty is a significant complication with a high mortality rate in elderly patients. Previous studies have shown a higher risk of dislocation in patients with neuromuscular conditions. In this study, we reviewed our larger cohort of patients to identify if there is a link between neuromuscular disorders and dislocation of hip hemiarthroplasty in patients with neuromuscular conditions. Materials and Methods. We have retrospectively analysed a single-centre data that was collected over 34 years for patients with intracapsular neck of femur fracture who underwent hip hemiarthroplasty. The study population was composed of four groups: patients with no neuromuscular disorders, patients with Parkinson's disease, patients with previous stroke, and patients with mental impairment. Results. A total of 3827 patients were included in the analysis. 3371 patients had no neuromuscular condition (Group I) with a dislocation rate of 1.1%. 219 patients had Parkinsonism (Group II) with a dislocation rate of 3.2%, 104 patients had a previous stroke with weakness on the fracture side with a dislocation rate of 1.0% (Group III), and 984 patients had severe mental impairment with a dislocation rate of 1.8% (Group IV). The increased dislocation rate for those with Parkinson's disease was statistically significant (p=0.02) while none of the other neuromuscular conditions were statistically significant. Conclusions. Our study has shown an increased risk of dislocation of hemiarthroplasty in patients with Parkinson's disease in comparison to other groups. No increase was apparent for patients with mental impairment or weakness from a previous stroke


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 95 - 95
17 Apr 2023
Gupta P Butt S Galhoum A Dasari K
Full Access

Between 2016–2019, 4 patients developed hip infections post-hemiarthroplasty. However, between 2020–2021 (Covid-19 pandemic period), 6 patients developed hip infections following hip hemiarthroplasty. The purpose of the investigation is to establish the root causes and key learning from the incident and use the information contained within this report to reduce the likelihood of a similar incident in the future. 65 patients presented with a neck of femur fracture during Covid-19 pandemic period between 2020–2021, 26 had hip hemiarthroplasty of which 6 developed hip infections. Medical records, anaesthetic charts and post-hip infections guidelines from RCS and NICE were utilised. Proteus, Enterococci and Strep. epidermis were identified as the main organisms present causing the hip infection. The average number of ward moves was 4 with 90% of patients developing COVID-19 during their hospital stay. The chance of post-operative wound infection were multifactorial. Having had 5 of 6 patients growing enterococci may suggest contamination of wound either due to potential suboptimal hygiene measures, inadequate wound management /dressing, potential environmental contamination if the organisms (Vancomycin resistant enterococci) are found to be of same types and potential hospital acquired infection due to inadequate infection control measures or suboptimal hand hygiene practices. 3 of the 5 patients grew Proteus, which points towards suboptimal hygiene practices by patients or poor infection control practices by staff. Lack of maintenance of sterility in post op wound dressings alongside inexperience of the handling of post-operative wound in non-surgical wards; multiple ward transfers exceeding the recommended number according to trust guidelines especially due to pandemic isolation measures and COVID-19 infection itself had resulted in an increased rate of hip infections during the COVID-19 pandemic. Multidisciplinary team education and planned categorisation and isolation strategy is essential to minimise the rate of further hip infections during the pandemic period in future


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 74 - 74
1 Nov 2021
Conforti LG Faggiani M Risitano S
Full Access

Introduction and Objective. Interest for direct anterior approach (DAA) in hip hemiarthroplasty (HHA) has greatly increased in recent years, however which is the best surgical approach in hip replacement treating femoral neck fractures (FNFs) is already unclear. The aim of this study is to perform a radiographic and perioperative complications analysis by comparing the direct anterior approach (DAA) with the direct lateral approach (DLA) in patients treated with hemiarthroplasty for FNFs. Materials and Methods. Patients with FNFs surgically treated between 2016–2020 with HHA were enrolled. The radiographical outcomes of DAA and DLA are compared. Several peri-operative and post-operative variables were evaluated: mean surgery time, complications as periprosthetic fractures or episodes of dislocation, the average of post-operative diaphyseal filling of the stem (Canal Fill Index, CFI), the extent of heterotopic ossification (HO) (simplified Broker classification) and metadiaphiseal bone loss (Paprosky classification) within one year from surgery. Results. 86 patients underwent HHA by DAA and 80 patients by DLA. The two groups are qualitatively comparable. No statistically significate differences were showed in all variables analyzed (p>0.05). The average of surgical time of DAA were 61 minutes compared to 67 of DLA. No differences were showed in the post-operative CFI (DAA 0.71 ± 6.1; DLA 0.76 ± 13.5), the extent of the HO (DAA 79.07% low; DLA 75% low) and metadiaphiseal bone loss (DAA Grade I 91.86%; DLA Grade I 93.75%). Regarding perioperative complications, we have discovered only one periprosthetic fracture each group. Although there was no statistically significant difference, we highlighted a higher number of dislocations in the group of DLA (2 episodes vs no one). Conclusions. In this study we have shown that the DAA is an adequate surgical choice comparing with the classical DLA for FNFs treated with HHA. The analysis of our radiographic parameters and perioperative complications have not shown a significant difference between the two surgical approach. This study is limited by a purely radiographic analysis without addition of clinical parameters


Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the Thompson implant when performing hip hemiarthroplasty and recommended surgeons consider using the anterolateral surgical approach over a posterior approach. Our objective was to review outcomes from a consecutive series of Thompson hip hemiarthroplasty procedures performed in our unit and to identify any factors predicting the risk of complications. 807 Thompson hip hemiarthroplasty cases performed between April 2008 and November 2013 were reviewed. 721 (89.3%) were cemented and 86 (10.7%) uncemented. 575 (71.3%) were performed in female patients. The anterolateral approach was performed in 753 (93.3%) and the posterior approach with enhanced soft tissue repair in 54 (6.7%). Overall, there were 23 dislocations (2.9%). Dislocation following the posterior approach occurred in 13.0% (7 of 54) in comparison to 2.1% (16 of 753) with the anterolateral approach (odds ratio (OR) 8.5 (95% CI 2.8 to 26.3) p < 0.001). Surgeon grade and patient history of cognitive impairment did not have a significant impact on dislocation rate. Patients were discharged home in 459 cases (56.9%), to a care home or other hospital in 273 cases (33.8%). 51.8% (338 of 653) returned home within 30 days. 75 died during their admission (9.3%). 30-day mortality was 7.1% and 1-year mortality was 16.6%. Intraoperative fracture occurred in 15 cases (1.9%) of which 14 were cemented. Superficial or deep infection occurred in 33 cases (4.1%). We recommend against the continued use of the posterior approach in hip hemiarthroplasty, as enhanced soft tissue repair did not reduce dislocation rates to an acceptable level. Our findings, however, demonstrate satisfactory results for patients treated with the Thompson hip hemiarthroplasty performed through an anterolateral approach. We suggest that the continued use of the Thompson implant in a carefully selected patient cohort is justifiable


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 69 - 69
1 Mar 2021
Ghani R Usman M Salar O Khan A Karim J Davis E Quraishi S Ahmed M
Full Access

Abstract. Objectives. Up to 19% of patients who undergo surgery for an acute hip fracture are readmitted to the hospital within three months of the index operation. We aimed to identify risk factors for unplanned clinic attendance, readmission, and mortality within the first 12 months postoperatively and subsequently determine if there is a role for routine follow-up. Methods. Patients greater than 65 years old who underwent hip hemiarthroplasty using an uncemented Thompson implant for treatment of a traumatic non-pathological hip fracture were identified from a prospectively maintained database at a single institution between August 2007 and February 2011. Patient demographics, comorbidities, place of residence, mobility status, unplanned attendance to an orthopaedic clinic with symptoms relating to the respective limb, readmission, and mortality were recorded. Results. Five hundred and fifty-four consecutive patients were identified. Unplanned clinic attendance was correlated to age (p = 0.000, B = −0.0159, 95% confidence interval (CI): −0.200 to −0.65), with patients between the ages of 65 – 70 years most likely to require unplanned clinic review postoperatively. The American Society of Anesthesiologists (ASA) grade (p = 0.019, 95% CI: 0.014 to 0.163) and frequency of unplanned outpatient attendance (p = 0.000, 95% CI: 0.120 to 0.284) were significantly associated with increased readmission within 12 months of the index procedure with patients who were regarded as ASA > 2 most likely to require readmission within the first postoperative year. Conclusion. To our knowledge, this is the first piece of research that identifies causative factors for unplanned clinic attendance and acute readmission during the first postoperative year in acute hip fracture patients treated by hemiarthroplasty. Routine scheduled follow-up of patients based on risk stratification may be effective in reducing the financial burden of unplanned clinic attendance. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 53 - 53
1 Aug 2013
Jensen C Gupta S Sprowson A Chambers S Inman D Jones S Aradhyula N Reed M
Full Access

Currently, the cement being used for hemiarthroplasties and total hip replacements by the authors and many other surgeons in the UK is Palacos® (containing 0.5g Gentamicin). Similar cement, Copal® (containing 1g Gentamicin and 1g Clindamycin) has been used in revision arthroplasties, and has shown to be better at inhibiting bacterial growth and biofilm formation. We aim to investigate the effect on SSI rates of doubling the gentamicin dose and adding a second antibiotic (clindamycin) to the bone cement in hip hemiarthroplasty. We randomised 848 consecutive patients undergoing cemented hip hemiarthroplasty for fractured NOF at one NHS trust (two sites) into two groups: Group I, 464 patients, received standard cement (Palacos®) and Group II, 384 patients, received high dose, double antibiotic-impregnated cement (Copal®). We calculated the SSI rate for each group at 30 days post-surgery. The patients, reviewers and statistician were blinded as to treatment group. The demographics and co-morbid conditions (known to increase risk of infection) were statistically similar between the groups. The combined superficial and deep SSI rates were 5 % (20/394) and 1.7% (6/344) for groups I and II respectively (p=0.01). Group I had a deep infection rate 3.3 %(13/394) compared to 1.16% (4/344) in group II (p=0.082). Group I had a superficial infection rate 1.7 % (7/394) compared to 0.58% (2/344) in group II (p=0.1861). 33(4%) patients were lost to follow up, and 77 (9%) patients were deceased at the 30 day end point. There was no statistical difference in the 30 day mortality, C. difficile infection, or the renal failure rates between the two groups. Using high dose double antibiotic-impregnated cement rather than standard low dose antibiotic-impregnated cement significantly reduced the SSI rate (1.7% vs 5%; p=0.01) after hip hemiarthroplasty for fractured neck of femur in this prospective randomised controlled trial


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 60 - 60
1 Jan 2017
Li L Logan K Nathan S
Full Access

Contrary to NICE guidance there remains a role for Austin-Moore hemiarthroplasty (AM) for patients with significant pre-existing comorbidities who are at higher risk of death and complications following cemented hemiarthroplasty.

We analysed prospectively-collected data comparing uncemented AM hemiarthroplasty in frail, poorly-mobile patients, and cemented hemiarthroplasty. We analysed age, pre-operative morbidity, duration of operation, death rate and complication rate.

AM patients were significantly older with significantly higher ASA grades. It took significantly longer to optimise them before surgery. AM was significantly shorter to perform. There was no significant difference in complications requiring re-operation. Twice as many AM patients developed post-operative pneumonia despite absence of cement. Twice as many AM patients died after surgery and a significant proportion died within the first month despite no increased risk of repeat operation, shorter operating time and no risk of cement-disease. We infer that these patients would likely have fared badly had they undergone a longer, cemented procedure. A modern cemented prosthesis costs £691 more than AM.

There exists a subset of patients within the neck of femur cohort who are significantly more unwell. Contrary to guidelines, we suggest that the cheaper, user-friendly Austin-Moore can be a reasonable prosthesis to use for this cohort.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 27 - 27
1 Apr 2012
Little K Hutchison J Crombie A
Full Access

The ‘cement reaction’ is a recognised cardio-respiratory response to methylmethacrylate bone cement, characterised by hypotension, reduced cardiac output, and on occasion fatal circulatory collapse. It is seen in 0.5-1% of cemented hip arthroplasties during the insertion and pressurisation of cement into the femur, and is believed to be secondary to marrow thromboembolism, the vasodilatory effect of methylmethacrylate, or a combination of the two. A number of steps, within the operating surgeon's control, can be undertaken to reduce the risk of the ‘cement reaction’ occurring.

An e-mail based questionnaire was sent to all trainees and consultants in the West of Scotland containing eight questions relating to cementing technique when performing hemiarthroplasty of the hip. The questions related to measures to reduce the potential for ‘cement reaction’, e.g.: whether or not they routinely use a cement restrictor.

Seventy-two complete replies were received. For five of the eight measures, the surgeons routinely employed the suggested practices. For the remaining three, the consensus opinion was contrary to the suggested practice for reduction of the risk of ‘cement reaction’. These were with respect to the surgical approach employed, whether or not to attempt to remove all cancellous bone from the proximal femur, and the use, or not, of a venting tube during cement insertion. In all three cases, the difference was statistically significant on chi-squared testing.

The cohort of surgeons questioned routinely employ more than half of the methods suggested to reduce the potential for ‘cement reaction’ in hemiarthroplasty of the hip. Further surveys of why they do, or do not, undertake certain practices during cementing would help improve awareness of ‘cement reaction’, and perhaps reduce the incidence of this potentially fatal phenomenon.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 99 - 99
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

The covid-19 pandemic had a great impact in the daily clinical and surgical practice. Concerning patients with a femoral neck fracture, there is the need of a negative Sars-CoV-2 test or an established isolation period for the positive cases, pre-operatively. The goal of this study was to evaluate the impact of the pandemic in the management of patients with femoral neck fractures, who were submitted to surgical treatment with hemiarthroplasty, in our hospital. A retrospective, observational study was performed, analysing the patients with femoral neck fractures submitted to hip hemiarthroplasty, during the years 2019 (before the pandemic) and 2020 (first year of the pandemic). We analysed the first 5 patients operated in each month of the mentioned years. We analysed 56 and 60 patients submitted to surgery in the years 2019 and 2020, respectively. The inpatient days were, in average, 14.1 and 13.1. Patients were operated, in average, 3.0 and 3.8 days after admission (corrected to 2.5 and 3.6 days if the time of discontinuation of anticoagulants or antiplatelets needed before surgery is deducted). There were peri-operative complications in 53.6% and 46.7% of the patients, in 2019 and 2020 respectively. The most common complication in both groups was a low postoperative haemoglobin level needing red blood cell transfusion. One-year postoperative mortality rate was 17.9% and 13.3%, respectively. Despite the changes triggered by the new pandemic, there was an overall maintenance of the quality of the management of these patients, with only a slight increase in the interval between admission and surgery. Some of the remaining variables even showed an improvement when comparing the two groups of patients. Nevertheless, it is important to mention that there were patients infected with Covid-19 who died before being submitted to surgery, therefore not being present in these statistics


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 92 - 92
11 Apr 2023
O'Boyle M Fraser E Dickson S Mansbridge D
Full Access

Neck of femur fractures are a common trauma presentation and patients with a history of malignancy are sent for long leg femur views (LLF), to exclude a distal lesion which would alter the management plan (Intra-medullary nail/Long stem Hemiarthroplasty). The aim of this is to identify incidence of malignancy on LLF views, the length of time in between each xray (XR) and to identify demographics. Data was retrospectively collected from 01/01/2021 to 31/01/2021 from a single centre. All patients admitted to the Queen Elizabeth University Hospital had their electronic records (Bluespier, PACS, Clinical Portal) accessed. These confirmed if patients had a past medical history of malignancy, if they had LLF view and the time differences between diagnostic pelvis XR and LLF XR. A total of 784 patients were identified in the specified time period. Of these, 138 were identified with a malignancy and there were 85 LLF views completed. LLF views diagnosed 1 patient with known prostate cancer that had a new distal femoral metastasis (Incidence = 1.28 cases per 1000). This patient underwent further imaging (MRI Femur) and received a long stem hip hemiarthroplasty. The average length of wait between the images was 9 hours 27 minutes. LLF views can alter management of patients with malignancy and are therefore useful to perform. There can be a long delay between each image. Therefore we recommend imaging tumour with common bony metastasis (Renal, Thyroid, Breast, Prostrate, Lung) and other remaining tumours with known secondary metastasis. Imaging primary low risk (eg basal cell carcinoma) can lead to long delays in a frail patient cohort and consideration should be given to rationalise appropriate use of resources


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 66 - 66
1 Mar 2021
Bong GSY Browne TJ Morrissey D
Full Access

Abstract. Objectives. To analyse the costs and benefits of sending femoral head specimens for histopathological analysis and whether our practice had changed since the original study five years ago. Methods. The cohort definition was patients who had both undergone hip hemiarthroplasties (HHAs) and had femoral head specimens sent for histopathological analysis at our tertiary care institution from 2013 to 2016. Retrospective review of clinical and electronic notes was performed on these patients for history of malignancy, histopathological diagnosis of femoral head, indication for histopathological examination and radiological studies. The total number of HHAs performed at the centre and the costs involved in analysing each femoral head specimen were identified. Results. A total of 805 HHAs were performed at the centre. We identified 56 femoral head specimens from 56 patients (6.96%) that were sent for histopathological analysis after HHA. 29 patients (51.79%) had a known history of malignancy. Three femoral head specimens (10.34%) were histologically positive for malignancy. Two patients had hip radiographs demonstrating metastasis to the femoral head. The third patient had a PET-CT scan two weeks prior to fracture that did not show signs of metastatic disease. 27 patients (48.21%) had no history of malignancy. None of their femoral head specimens were found to be histologically positive for malignancy. 10 patients had no appropriate indication for histopathological analysis. The cost savings for 27 patients with no previous history of malignancy ranged from €2,295 to €9,504. The cost savings for 10 patients with no appropriate indication ranged from €850 to €3,520. Conclusions. Histopathological analysis of femoral head specimens after HHA has little benefit for patients without a history of malignancy. The practice at our institution had not changed significantly in the past five years. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Bone & Joint 360
Vol. 12, Issue 6 | Pages 49 - 51
1 Dec 2023
Burden EG Whitehouse MR Evans JT


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 15 - 15
1 Mar 2013
Petheram T Bone M Joyce T Partington P
Full Access

Recent NICE guidance recommends use of a well proven cemented femoral stem for hip hemiarthroplasty in management of fractured neck of femur. The Exeter Trauma Stem (ETS) has been designed based on the well proven Exeter hip stem. It has a double taper polished stem design, proclaimed to share geometry and surface finish with the Exeter hip. This study investigated the surface finish of the two stems in order to investigate the hypothesis that they were different. Two ETS and two Exeter stems were examined using a profilometer with a sensitivity of one nanometer. Macroscopic visual inspection showed that the two Exeter stems had significantly smoother surface finish than the ETS stems. The roughness average (RA) values on the ETS stems were approximately an order of magnitude higher than those of the Exeter stems, mean of 0.235μm compared with 0.025μm (p<0.0001). This difference in surface finish has implications for the biomechanical functioning of the stem. Previous change of the Exeter stem to a matt surface-finish in 1976 resulted in a significant increase in stem failure rates and an understanding of the importance of the polished surface-finish in order to function within a taper-slip philosophy. By changing the surface finish in the ETS stem, longevity of the implant may similarly be affected. Clinical results have yet to be published demonstrating this. We recommend the manufacturer reconsiders the surface finish of the ETS stem to ensure it functions as well as the Exeter primary stem with which it shares a design philosophy


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 38 - 38
1 Aug 2013
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established, and a case note review was carried out. There was 1397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 15 patients (4% of uncemented hemiarthoplasties) had peri-prosthetic fractures. There were no peri-prosthetic fractures in the cemented group, p = 0.004 using Fisher's exact test. The case notes of these patients were analysed. We found there was a common link of significant cardiovascular risk, lack of falls assessment (only 14% of the patients had a completed falls assessment and 21% sustained their fracture during an admission to hospital) and confusion (50% had a degree of dementia that caused significant confusion). Cemented implants should be considered in all patients, especially those who are cognitively impaired or have failed falls assessments; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaesthetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 21 - 21
1 Apr 2012
Grant S Holt G Gregori A
Full Access

Details of orthopaedic implants in Scotland are recorded on a national database. The results are used by the Scottish Arthroplasty Project to record survival and complication rates for both knee and hip replacements. The aim of our study was to assess the accuracy of recorded data for unicompartmental knee replacements in the West of Scotland. The national database was searched for all unicompartmental knee replacements carried out in the West of Scotland between March 2000 to October 2004. All patient data was then crosschecked with hospital theatre records and case notes for confirmation of accuracy. A total of 88 cases were coded as unicompartment joint replacements in the study period. 63 cases were confirmed as being accurate (71.6%) and 6 as being inaccurate (6.8%). 19 patient details were not available for review either from notes or theatre records (21.6%). Of those coded inaccurately, five were total knee replacements, one cemented hip hemiarthroplasty and one shoulder replacement. One case of miscoding could be accounted for as an error in documentation while in six cases no cause could be identified. Of the 63 knees confirmed as unicompartmental, seven knees had been revised within 5 years, giving a 5 year survival rate of 87.7%. The current system used by the Scottish Arthroplasty Project in Scotland has at least a 6.8% inaccuracy rate when recording unicompartmental knee replacements


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 41 - 41
1 Jun 2012
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemeted prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established and a case note review carried out. There were 397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 14 patients (4% of uncemented arthoplasties) had peri-prosthetic fractures. The case notes of these patients were analysed. There was a common link of significant cardiovascular risk, lack of falls assessment, and confusion. Cemented implants should be considered in those who have failed falls assessment, or are confused; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaethetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 118 - 123
1 Jan 2001
Coathup MJ Blunn GW Flynn N Williams C Thomas NP

We investigated the implant-bone interface around one design of femoral stem, proximally coated with either a plasma-sprayed porous coating (plain porous) or a hydroxyapatite porous coating (porous HA), or which had been grit-blasted (Interlok). Of 165 patients implanted with a Bimetric hip hemiarthroplasty (Biomet, Bridgend, UK) specimens were retrieved from 58 at post-mortem. We estimated ingrowth and attachment of bone to the surface of the implant in 21 of these, eight plain porous, seven porous HA and six Interlok, using image analysis and light morphometric techniques. The amount of HA coating was also quantified. There was significantly more ingrowth (p = 0.012) and attachment of bone (p > 0.05) to the porous HA surface (mean bone ingrowth 29.093 ± 2.019%; mean bone attachment 37.287 ± 2.489%) than to the plain porous surface (mean bone ingrowth 21.762 ± 2.068%; mean bone attachment 18.9411 ± 1.971%). There was no significant difference in attachment between the plain porous and Interlok surfaces. Bone grew more evenly over the surface of the HA coating whereas on the porous surface, bone ingrowth and attachment occurred more on the distal and medial parts of the coated surface. No significant differences in the volume of HA were found with the passage of time. This study shows that HA coating increases the amount of ingrowth and attachment of bone and leads to a more even distribution of bone over the surface of the implant. This may have implications in reducing stress shielding and limiting osteolysis induced by wear particles


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 89 - 89
1 May 2012
Chan K Koh H Zubairy A
Full Access

INTRODUCTION. Warfarin remains the treatment of choice for the majority of patients with venous thromboembolism, atrial fibrillation and valvular heart disease or valve replacement unless contraindicated. Poor management of patients on warfarin often leads to delay in surgery, life threatening bleeding during or after operation and unnecessary delay in discharge from hospitals in United Kingdom. METHODS. We carried out a prospective study on patients who were on warfarin and underwent elective and emergency orthopaedic procedures during period of study- August 2007 to April 2008. All patients included in the study were identified from admission notes during period of study. All data regarding indications for warfarin, pre and post procedures INR, elective or emergency orthopaedic procedures and complications were collected using a standard proforma. RESULTS. 18 patients, 12 male and 6 female were included into the study. Patients' age ranged from 47-87 with mean of 76. The indications for warfarin therapy were atrial fibrillation in 12 patients, deep vein thrombosis in 5 patients and left ventricular aneurysm in 1 patient. 18 procedures, 10 elective and 8 emergency orthopaedic procedures were carried out during period of study. Elective procedures - 7 primary joint arthroplasty, 1 revision hip arthroplasty, 1 removal of metalwork and 1 metatarsophalangeal joint fusion. Emergency procedures - 4 hip hemiarthroplasty, 2 dynamic hip screw fixation, 1 external fixator application and 1 open reduction and internal fixation of ankle. All elective admission patients were pre-assessed in clinic prior to admission and were advised to stop warfarin based on their INR level. Patients with INR 2-3 had their warfarin stopped 4 days prior to surgery while patients with INR 3-4.5 had their warfarin stopped 5 days prior to surgery. This group of patients had their INR check on admission and ranged from 1.1-1.5. This group of patients had no reversal therapy and no cancellations were made to their operation. 8 emergency admission patients had INR of 1.4-4.7 on admission with mean of 2.7. 5 patients had reversal therapy while 3 patients had no reversal therapy. Pharmacological methods used to reduce the INR were fresh frozen plasma in 1 patient and Vitamin K in 4 other patients. 2 patients that received reversal therapy had operation on day 1, 2 on day 3 and 1 on day 5. 1 patient that had no reversal therapy was operated on day 1, 1 on day 3 and 1 on day 5. Patient that received no reversal therapy and operated on day 5 of admission died post-operatively from medical complications. Mean delay for patient that had reversal therapy was 2.2 days compared to 3 days in patient with no reversal therapy. All patients in this study had prophylactic low molecular weight heparin while off warfarin. Patients were recommenced on their normal dose of warfarin the day after their operation. DISCUSSION & CONCLUSIONS. We conclude that patients on warfarin with INR 2-3 should have their warfarin stopped 4 days prior to surgery while patients with INR 3-4.5 should stop their warfarin 5 days prior to elective surgery. Trauma patients on warfarin requiring operation should have their INR reversed on admission to shorten delay in waiting time and improve outcomes