Advertisement for orthosearch.org.uk
Results 1 - 20 of 398
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 991 - 998
1 May 2021
Lyu X Chen T Yang Z Fu G Feng C Zhang T Lu M

Aims. The objective of this study was to evaluate the clinical and radiological outcomes of patients younger than six months of age with developmental dysplasia of the hip (DDH) managed by either a Pavlik harness or Tübingen hip flexion splint. Methods. Records of 251 consecutive infants with a mean age of 89 days (SD 47), diagnosed with DDH between January 2015 and December 2018, were retrospectively reviewed. Inclusion criteria for patients with DDH were: younger than 180 days at the time of diagnosis; ultrasound Graf classification of IIc or greater; treatment by Pavlik harness or Tübingen splint; and no prior treatment history. All patients underwent hip ultrasound every seven days during the first three weeks of treatment and subsequently every three to four weeks until completion of treatment. If no signs of improvement were found after three weeks, the Pavlik harness or Tübingen splint was discontinued. Statistical analysis was performed. Results. The study included 251 patients with Graf grades IIc to IV in 18 males and 233 females with DDH. Mean follow-up time was 22 months (SD 10). A total of 116 hips were graded as Graf IIc (39.1%), nine as grade D (3.0%), 100 as grade III (33.7%), and 72 as grade IV (24.2%). There were 109 patients (128 hips) in the Pavlik group and 142 patients (169 hips) in the Tübingen group (p = 0.227). The Tübingen group showed a 69.8% success rate in Graf III and Graf IV hips while the success rate was significantly lower in the Pavlik group, 53.9% (p = 0.033). For infants older than three months of age, the Tübingen group showed a 71.4% success rate, and the Pavlik group a 54.4% success rate (p = 0.047). Conclusion. The Tübingen splint should be the preferred treatment option for children older than three months, and for those with severe forms of DDH such as Graf grade III and IV, who are younger than six months at time of diagnosis. The Tübingen hip flexion splint is a valid alternative to the Pavlik harness for older infants and those with more severe DDH. Cite this article: Bone Joint J 2021;103-B(5):991–998


Bone & Joint Research
Vol. 12, Issue 1 | Pages 22 - 32
11 Jan 2023
Boschung A Faulhaber S Kiapour A Kim Y Novais EN Steppacher SD Tannast M Lerch TD

Aims

Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients.

Methods

A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method).


Bone & Joint Research
Vol. 5, Issue 5 | Pages 198 - 205
1 May 2016
Wang WJ Liu F Zhu Y Sun M Qiu Y Weng WJ

Objectives. Normal sagittal spine-pelvis-lower extremity alignment is crucial in humans for maintaining an ergonomic upright standing posture, and pathogenesis in any segment leads to poor balance. The present study aimed to investigate how this sagittal alignment can be affected by severe knee osteoarthritis (KOA), and whether associated changes corresponded with symptoms of lower back pain (LBP) in this patient population. Methods. Lateral radiograph films in an upright standing position were obtained from 59 patients with severe KOA and 58 asymptomatic controls free from KOA. Sagittal alignment of the spine, pelvis, hip and proximal femur was quantified by measuring several radiographic parameters. Global balance was accessed according to the relative position of the C7 plumb line to the sacrum and femoral heads. The presence of chronic LBP was documented. Comparisons between the two groups were carried by independent samples t-tests or chi-squared test. Results. Patients with severe KOA showed significant backward femoral inclination (FI), hip flexion, forward spinal inclination, and higher prevalence of global imbalance (27.1% versus 3.4%, p < 0.001) compared with controls. In addition, patients with FI of 10° (n = 23) showed reduced lumbar lordosis and significant forward spinal inclination compared with controls, whereas those with FI > 10° (n = 36) presented with significant pelvic anteversion and hip flexion. A total of 39 patients with KOA (66.1%) suffered from LBP. There was no significant difference in sagittal alignment between KOA patients with and without LBP. Conclusions. The sagittal alignment of spine-pelvis-lower extremity axis was significantly influenced by severe KOA. The lumbar spine served as the primary source of compensation, while hip flexion and pelvic anteversion increased for further compensation. Changes in sagittal alignment may not be involved in the pathogenesis of LBP in this patient population. Cite this article: W. J. Wang, F. Liu, Y.W. Zhu, M.H. Sun, Y. Qiu, W. J. Weng. Sagittal alignment of the spine-pelvis-lower extremity axis in patients with severe knee osteoarthritis: A radiographic study. Bone Joint Res 2016;5:198–205. DOI:10.1302/2046-3758.55.2000538


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims. The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique. Methods. This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively. Results. A total of 517 patients were included in the study. Their mean age was 65.0 years (SD 10.3) and their mean BMI was 29.2 kg/m. 2. (SD 5.5). A mean of 1.2 levels (SD 0.6) were fused with LLIF, and a mean of 1.6 (SD 0.9) posterior levels were fused. Femoral neuropraxia occurred in six patients (1.2%), of which four (0.8%) were LLIF-related and two (0.4%) had persistent symptoms one year postoperatively. Non-femoral neuropraxia occurred in nine patients (1.8%), one (0.2%) was LLIF-related and five (1.0%) were persistent at one year. All LLIF-related neuropraxias resolved by one year. A total of 32 patients (6.2%) had thigh pain, 31 (6.0%) were LLIF-related and three (0.6%) were persistent at one year. Weakness of hip flexion occurred in 14 patients (2.7%), of which eight (1.6%) were LLIF-related and three (0.6%) were persistent at one year. No patients had bowel injury, three (0.6%) had an intraoperative vascular injury (not LLIF-related), and five (1.0%) had ileus. Reoperations occurred in five patients (1.0%) within 30 days, 37 (7.2%) within 90 days, and 41 (7.9%) within one year postoperatively. Conclusion. LLIF involving the L4-L5 disc level has a low rate of persistent neurological, psoas-related, and abdominal complications in patients with the appropriate indications and using a standardized surgical technique. Cite this article: Bone Joint J 2024;106-B(1):53–61


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 23 - 23
1 Dec 2022
Innmann MM Verhaegen J Reichel F Schaper B Merle C Grammatopoulos G
Full Access

The presence of hip osteoarthritis is associated with abnormal spinopelvic characteristics. This study aims to determine whether the pre-operative, pathological spinopelvic characteristics “normalize” at 1-year post-THA. This is a prospective, longitudinal, case-control matched cohort study. Forty-seven patients underwent pre- and post- (at one-year) THA assessments. This group was matched (age, sex, BMI) with 47 controls/volunteers with well-functioning hips. All participants underwent clinical and radiographic assessments including lateral radiographs in standing, upright-seated and deep-flexed-seated positions. Spinopelvic characteristics included change in lumbar lordosis (ΔLL), pelvic tilt (ΔPT) and hip flexion (pelvic-femoral angle, ΔPFA) when moving from the standing to each of the seated positions. Spinopelvic hypermobility was defined as ΔPT>30° between standing and upright-seated positions. Pre-THA, patients illustrated less hip flexion (ΔPFA −54.8°±17.1° vs. −68.5°± 9.5°, p<0.001), greater pelvic tilt (ΔPT 22.0°±13.5° vs. 12.7°±8.1°, p<0.001) and greater lumbar movements (ΔLL −22.7°±15.5° vs. −15.4°±10.9°, p=0.015) transitioning from standing to upright-seated. Post-THA, these differences were no longer present (ΔPFApost −65.8°±12.5°, p=0.256; ΔPTpost 14.3°±9.5°, p=0.429; ΔLLpost −15.3°±10.6°, p=0.966). The higher prevalence of pre-operative spinopelvic hypermobility in patients compared to controls (21.3% vs. 0.0%; p=0.009), was not longer present post-THA (6.4% vs. 0.0%; p=0.194). Similar results were found moving from standing to deep-seated position post-THA. Pre-operative, spinopelvic characteristics that contribute to abnormal mechanics can normalize post-THA following improvement in hip flexion. This leads to patients having the expected hip-, pelvic- and spinal flexion as per demographically-matched controls, thus potentially eliminating abnormal mechanics that contribute to the development/exacerbation of hip-spine syndrome


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 77 - 77
19 Aug 2024
Fu H Singh G H C Lam J Yan CH Cheung A Chan PK Chiu KY
Full Access

Hip precautions following total hip arthroplasty (THA) limits flexion, adduction and internal rotation, yet these precautions cause unnecessary psychological stress. This study aims to assess bony and implant impingement using virtual models from actual patient's bony morphology and spinopelvic parameters to deduce whether hip precautions are necessary with precise implant positioning in the Asian population. Individualized sitting and standing sacral slope data of robotic THAs performed at two tertiary referral centers in Hong Kong was inputted into the simulation system based on patients’ pre-operative sitting and standing lumbar spine X-rays. Three-dimensional dynamic models were reconstructed using the Stryker Mako THA 4.0 software to assess bony and implant impingement both anteriorly and posteriorly, with default cup placement at 40° inclination and 20° anteversion. Femoral anteversion followed individual patient's native version. A 36mm hip ball was chosen for all cups equal or above 48mm and 32mm for those below. Anterior impingement was assessed by hip flexion and posterior impingement was assessed by hip extension. 113 patients were included. At neutral rotation and adduction, no patients had anterior implant impingement at hip flexion of 100°. 1.7% had impingement at 110°, 3.5% had impingement at 120°, 9.7% had impingement at 130°. With 20° of internal rotation and adduction, 0.8% had anterior implant impingement at hip flexion of 90°, 7.1% had impingement at 100° and 18.5% had impingement at 110°. With the hip externally rotated by 20°, 0.8% of patients had posterior implant impingement, and 8.8% bony impingement at 0° extension. With enabling technology allowing accurate component positioning, hip precautions without limiting forward flexion in neutral position is safe given precise implant positioning and adequate osteophyte removal. Patients should only be cautioned about combined internal rotation, adduction with flexion


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 41 - 41
1 Dec 2022
Verhaegen J Innmann MM Batista NA Dion C Pierrepont J Merle C Grammatopoulos G
Full Access

The study of spinopelvic anatomy and movement has received great interest as these characteristics influence the biomechanical behavior (and outcome) following hip arthroplasty. However, to-date there is little knowledge of what “normal” is and how this varies with age. This study aims to determine how dynamic spino-pelvic characteristics change with age, with well-functioning hips and assess how these changes are influenced by the presence of hip arthritis. This is an IRB-approved, cross-sectional, cohort study; 100 volunteers (asymptomatic hips, Oxford-Hip-sore>45) [age:53 ± 17 (24-87) years-old; 51% female; BMI: 28 ± 5] and 200 patients with end-stage hip arthritis [age:56 ± 19 (16-89) years-old; 55% female; BMI:28 ± 5] were studied. All participants underwent lateral spino-pelvic radiographs in the standing and deep-seated positions to determine maximum hip and spine flexion. Parameters measured included lumbar-lordosis (LL), pelvic incidence, pelvic-tilt (PT), pelvic-femoral angles (PFA). Lumbar flexion (ΔLL), hip flexion (ΔPFA) and pelvic movement (ΔPT) were calculated. The prevalence of spinopelvic imbalance (PI–LL>10?) was determined. There were no differences in any of the spino-pelvic characteristics or movements between sexes. With advancing age, standing LL reduced and standing PT increased (no differences between groups). With advancing age, both hip (4%/decade) and lumbar (8%/decade) flexion reduced (p<0.001) (no difference between groups). ΔLL did not correlate with ΔPFA (rho=0.1). Hip arthritis was associated with a significantly reduced hip flexion (82 ±;22? vs. 90 ± 17?; p=0.003) and pelvic movements (1 ± 16? vs. 8 ± 16?; p=0.002) at all ages and increased prevalence of spinopelvic imbalance (OR:2.6; 95%CI: 1.2-5.7). With aging, the lumbar spine loses its lumbar lordosis and flexion to a greater extent that then the hip and resultantly, the hip's relative contribution to the overall sagittal movement increases. With hip arthritis, the reduced hip flexion and the necessary compensatory increased pelvic movement is a likely contributor to the development of hip-spine syndrome and of spino-pelvic imbalance


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 65 - 65
17 Nov 2023
Khatib N Schmidtke L Lukens A Arichi T Nowlan N Kainz B
Full Access

Abstract. Objectives. Neonatal motor development transitions from initially spontaneous to later increasingly complex voluntary movements. A delay in transitioning may indicate cerebral palsy (CP). The general movement optimality score (GMOS) evaluates infant movement variety and is used to diagnose CP, but depends on specialized physiotherapists, is time-consuming, and is subject to inter-observer differences. We hypothesised that an objective means of quantifying movements in young infants using motion tracking data may provide a more consistent early diagnosis of CP and reduce the burden on healthcare systems. This study assessed lower limb kinematic and muscle force variances during neonatal infant kicking movements, and determined that movement variances were associated with GMOS scores, and therefore CP. Methods. Electromagnetic motion tracking data (Polhemus) was collected from neonatal infants performing kicking movements (min 50° knee extension-flexion, <2 seconds) in the supine position over 7 minutes. Tracking data from lower limb anatomical landmarks (midfoot inferior, lateral malleolus, lateral knee epicondyle, ASIS, sacrum) were applied to subject-scaled musculoskeletal models (Gait2354_simbody, OpenSim). Inverse kinematics and static optimisation were applied to estimate lower limb kinematics (knee flexion, hip flexion, hip adduction) and muscle forces (quadriceps femoris, biceps femoris) for isolated kicks. Functional principal component analysis (fPCA) was carried out to reduce kicking kinematic and muscle force waveforms to PC scores capturing ‘modes’ of variance. GMOS scores (lower scores = reduced variety of movement) were collected in parallel with motion capture by a trained operator and specialised physiotherapist. Pearson's correlations were performed to assess if the standard deviation (SD) of kinematic and muscle force waveform PC scores, representing the intra-subject variance of movement or muscle activation, were associated with the GMOS scores. Results. The study compared GMOS scores, kinematics, and muscle force variances from a total of 26 infants with a mean corrected gestational age of 39.7 (±3.34) weeks and GMOS scores between 21 and 40. There was a significant association between the SD of the PC scores for knee flexion and the GMOS scores (PC1: R = 0.59, p = 0.002; PC2: R = 0.49, p = 0.011; PC3: R = 0.56, p = 0.003). The three PCs captured variances of the overall flexion magnitude (66% variance explained), early-to-late kick knee extension (20%), and continual to biphasic kicking (6%). For hip flexion, only the SD of PC1 correlated with GMOS scores (PC1: R = 0.52, p = 0.0068), which captured the variance of the overall flexion magnitude (81%). For the biceps femoris, the SD of PC1 and PC3 associated with GMOS scores (PC1: R = 0.50, p = 0.002; PC3: R = 0.45, p = 0.03), which captured the variance of the overall bicep force magnitude (79%) and early-to-late kick bicep activation (8%). Conclusions. Infants with reduced motor development as scored in the GMOS displayed reduced variances of knee and hip flexion and biceps femoris activation across kicking cycles. These findings suggest that combining objectively measured movement variances with existing classification methods could facilitate the development of more consistent and accurate diagnostic tools for early detection of CP. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Bone & Joint Open
Vol. 2, Issue 11 | Pages 988 - 996
26 Nov 2021
Mohtajeb M Cibere J Mony M Zhang H Sullivan E Hunt MA Wilson DR

Aims. Cam and pincer morphologies are potential precursors to hip osteoarthritis and important contributors to non-arthritic hip pain. However, only some hips with these pathomorphologies develop symptoms and joint degeneration, and it is not clear why. Anterior impingement between the femoral head-neck contour and acetabular rim in positions of hip flexion combined with rotation is a proposed pathomechanism in these hips, but this has not been studied in active postures. Our aim was to assess the anterior impingement pathomechanism in both active and passive postures with high hip flexion that are thought to provoke impingement. Methods. We recruited nine participants with cam and/or pincer morphologies and with pain, 13 participants with cam and/or pincer morphologies and without pain, and 11 controls from a population-based cohort. We scanned hips in active squatting and passive sitting flexion, adduction, and internal rotation using open MRI and quantified anterior femoroacetabular clearance using the β angle. Results. In squatting, we found significantly decreased anterior femoroacetabular clearance in painful hips with cam and/or pincer morphologies (mean -11.3° (SD 19.2°)) compared to pain-free hips with cam and/or pincer morphologies (mean 8.5° (SD 14.6°); p = 0.022) and controls (mean 18.6° (SD 8.5°); p < 0.001). In sitting flexion, adduction, and internal rotation, we found significantly decreased anterior clearance in both painful (mean -15.2° (SD 15.3°); p = 0.002) and painfree hips (mean -4.7° (SD 13°); p = 0.010) with cam and/pincer morphologies compared to the controls (mean 7.1° (SD 5.9°)). Conclusion. Our results support the anterior femoroacetabular impingement pathomechanism in hips with cam and/or pincer morphologies and highlight the effect of posture on this pathomechanism. Cite this article: Bone Jt Open 2021;2(11):988–996


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 6 - 6
7 Jun 2023
Declercq J Vandeputte F Corten K
Full Access

Tenotomy of the iliopsoas tendon has been described as an effective procedure to treat refractive groin pain induced by iliopsoas tendinitis. However, the procedure forces the rectus femoris to act as the primary hip flexor and little is known about the long-term effects of this procedure on the peri-articular muscle envelope (PAME). Studies suggest that iliopsoas tenotomy results in atrophy of the iliopsoas and decreased hip flexion strength with poorer outcomes, increasing the susceptibility for secondary tendinopathy. The aim of this study is to describe changes in the PAME following psoas release. All patients who presented for clinical examination at our hospital between 2016 and 2021 were retrospectively reviewed. Patients who presented after psoas tenotomy with groin pain and who were unable to actively lift the leg against gravity, were included. Pelvic MRI was taken. Qualitative muscle evaluation was done with the Quartile classification system. Quantitative muscle evaluation was done by establishing the cross-sectional area (CSA). Two independent observers evaluated the ipsi- and contralateral PAME twice. The muscles were evaluated on the level: iliacus, psoas, gluteus minimus-medius-maximus, rectus femoris, tensor fasciae lata, piriformis, obturator externus and internus. For the qualitative evaluation, the intra- and inter-observer reliability was calculated by using kappastatistics. A Bland-Altman analysis was used to evaluate the intra- and inter-observer reliability for the quantitative evaluation. The Wilcoxon test was used to evaluate the changes between the ipsi- and contra-lateral side. 17 patients were included in the study. Following psoas tenotomy, CSA reduced in the ipsilateral gluteus maximus, if compared with the contralateral side. Fatty degeneration occurred in the tensor fascia latae. Both CSA reduction and fatty degeneration was seen for psoas, iliacus, gluteus minimus, piriformis, obturator externus and internus. No CSA reduction and fatty degeneration was seen for gluteus medius and rectus femoris. Conclusions/Discussion. Following psoas tenotomy, the PAME of the hip shows atrophy and fatty degeneration. These changes can lead to detrimental functional problems and may be associated with debilitating rectus femoris tendinopathy. In patients with psoas tendinopathy, some caution is advised when considering an iliopsoas tenotomy


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 20 - 20
1 Dec 2022
Ng G El Daou H Bankes M Cobb J Beaulé P
Full Access

Femoroacetabular impingement (FAI) – enlarged, aspherical femoral head deformity (cam-type) or retroversion/overcoverage of the acetabulum (pincer-type) – is a leading cause for early hip osteoarthritis. Although anteverting/reverse periacetabular osteotomy (PAO) to address FAI aims to preserve the native hip and restore joint function, it is still unclear how it affects joint mobility and stability. This in vitro cadaveric study examined the effects of surgical anteverting PAO on range of motion and capsular mechanics in hips with acetabular retroversion. Twelve cadaveric hips (n = 12, m:f = 9:3; age = 41 ± 9 years; BMI = 23 ± 4 kg/m2) were included in this study. Each hip was CT imaged and indicated acetabular retroversion (i.e., crossover sign, posterior wall sign, ischial wall sign, retroversion index > 20%, axial plane acetabular version < 15°); and showed no other abnormalities on CT data. Each hip was denuded to the bone-and-capsule and mounted onto a 6-DOF robot tester (TX90, Stäubli), equipped with a universal force-torque sensor (Omega85, ATI). The robot positioned each hip in five sagittal angles: Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°; and performed hip internal-external rotations and abduction-adduction motions to 5 Nm in each position. After the intact stage was tested, each hip underwent an anteverting PAO, anteverting the acetabulum and securing the fragment with long bone screws. The capsular ligaments were preserved during the surgery and each hip was retested postoperatively in the robot. Postoperative CT imaging confirmed that the acetabular fragment was properly positioned with adequate version and head coverage. Paired sample t-tests compared the differences in range of motion before and after PAO (CI = 95%; SPSS v.24, IBM). Preoperatively, the intact hips with acetabular retroversion demonstrated constrained internal-external rotations and abduction-adduction motions. The PAO reoriented the acetabular fragment and medialized the hip joint centre, which tightened the iliofemoral ligament and slackenend the pubofemoral ligament. Postoperatively, internal rotation increased in the deep hip flexion positions of Flexion 60° (∆IR = +7°, p = 0.001) and Flexion 90° (∆IR = +8°, p = 0.001); while also demonstrating marginal decreases in external rotation in all positions. In addition, adduction increased in the deep flexion positions of Flexion 60° (∆ADD = +11°, p = 0.002) and Flexion 90° (∆ADD = +12°, p = 0.001); but also showed marginal increases in abduction in all positions. The anteverting PAO restored anterosuperior acetabular clearance and increased internal rotation (28–33%) and adduction motions (29–31%) in deep hip flexion. Restricted movements and positive impingement tests typically experienced in these positions with acetabular retroversion are associated with clinical symptoms of FAI (i.e., FADIR). However, PAO altered capsular tensions by further tightening the anterolateral hip capsule which resulted in a limited external rotation and a stiffer and tighter hip. Capsular tightness may still be secondary to acetabular retroversion, thus capsular management may be warranted for larger corrections or rotational osteotomies. In efforts to optimize surgical management and clinical outcomes, anteverting PAO is a viable option to address FAI due to acetabular retroversion or overcoverage


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1459 - 1463
1 Nov 2019
Enishi T Yagi H Higuchi T Takeuchi M Sato R Yoshioka S Nakamura M Nakano S

Aims. Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle strength, gait speed, and clinical outcome in the operated hip after RAO over a one-year period using a standard protocol for rehabilitation. Patients and Methods. A total of 57 patients underwent RAO for acetabular dysplasia. Changes in muscle strength of the operated hip, 10 m gait speed, Japanese Orthopaedic Association (JOA) hip score, and factors correlated with hip muscle strength after RAO were retrospectively analyzed. Results. Three months postoperatively, the strength of the operated hip in flexion and abduction and gait speed had decreased from their preoperative levels. After six months, the strength of flexion and abduction had recovered to their preoperative level, as had gait speed. At one-year follow-up, significant improvements were seen in the strength of hip abduction and gait speed, but muscle strength in hip flexion remained at the preoperative level. The mean JOA score for hip function was 91.4 (51 to 100)) at one-year follow-up. Body mass index (BMI) showed a negative correlation with both strength of hip flexion (r = -0.4203) and abduction (r = -0.4589) one year after RAO. Although weak negative correlations were detected between strength of hip flexion one year after surgery and age (r = -0.2755) and centre-edge (CE) angle (r = -0.2989), no correlation was found between the strength of abduction and age and radiological evaluations of CE angle and acetabular roof obliquity (ARO). Conclusion. Hip muscle strength and gait speed had recovered to their preoperative levels six months after RAO. The clinical outcome at one year was excellent, although the strength of hip flexion did not improve to the same degree as that of hip abduction and gait speed. A higher BMI may result in poorer recovery of hip muscle strength after RAO. Radiologically, acetabular coverage did not affect the recovery of hip muscle strength at one year’s follow-up. A more intensive rehabilitation programme may improve this. Cite this article: Bone Joint J 2019;101-B:1459–1463


Bone & Joint Open
Vol. 4, Issue 6 | Pages 416 - 423
2 Jun 2023
Tung WS Donnelley C Eslam Pour A Tommasini S Wiznia D

Aims. Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model. Methods. A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed. Results. In flexion, an overall impingement rate of 2.3% was detected for flexed-seated, squatting, forward-bending, and criss-cross-sitting positions, and 4.7% for the ankle-over-knee position. In extension, most hips (60.5%) were found to impinge at or prior to 50° of external rotation (pivoting). Many of these impingement events were due to a prominent ischium. The mean maximum external rotation prior to impingement was 45.9° (15° to 80°) and 57.9° (20° to 90°) prior to prosthetic impingement. No impingement was found in standing, sitting, crossing ankles, seiza, and downward dog. Conclusion. This study demonstrated that positions of daily living tested in a CT-based 3D model show high rates of impingement. Simulating additional positions through 3D modelling is a low-cost method of potentially improving outcomes without compromising patient safety. By incorporating CT-based 3D modelling of positions of daily living into routine preoperative protocols for THA, there is the potential to lower the risk of postoperative impingement events. Cite this article: Bone Jt Open 2023;4(6):416–423


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 60 - 60
1 Dec 2021
Rai A Khokher Z Kumar KHS Kuroda Y Khanduja V
Full Access

Abstract. Introduction. Recent reports show that spinopelvic mobility influences outcome following total hip arthroplasty. This scoping review investigates the relationship between spinopelvic parameters (SPPs) and symptomatic femoroacetabular impingement (FAI). Methods. A systematic search of EMBASE, PubMed and Cochrane for literature related to SPPs and FAI was undertaken as per PRISMA guidelines. Clinical outcome studies and prospective/retrospective studies investigating the role of SPPs in symptomatic FAI were included. Review articles, case reports and book chapters were excluded. Information extracted pertained to symptomatic cam deformities, pelvic tilt, acetabular version, biomechanics of dynamic movements and radiological FAI signs. Results. The search identified 42 papers for final analysis out of 1168 articles investigating the link between SPPs and pathological processes characteristic of FAI. Only one (2.4%) study was of level 1 evidence, five (11.9%) studies) were level 2, 17 (40.5%) were level 3 and 19 (45.2%) were level 4. Three studies associated FAI pathology with a greater pelvic incidence (PI), while four associated it with a smaller PI. Anterior pelvic tilt was associated with radiographic overcoverage parameters of FAI. In dynamic movements, decreased posterior pelvic tilt was a common feature in symptomatic FAI patients at increased hip flexion angles. FAI patients additionally demonstrated reduced sagittal pelvic ROM during dynamic hip flexion. Six studies found kinematic links between sagittal spinopelvic movement and sagittal and transverse plane hip movements. Conclusions. Our study shows that spinopelvic parameters can influence radiological and clinical manifestations of FAI, with pelvic incidence, acetabular version and muscular imbalances being aetiologically implicated. These factors may be amenable to non-surgical therapy. Individual spinopelvic mechanics may predispose to the development of FAI. If FAI pathoanatomy already exists, sagittal pelvic parameters can influence whether FAI symptoms develop and is an area of further research interest


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 902 - 909
1 Aug 2019
Innmann MM Merle C Gotterbarm T Ewerbeck V Beaulé PE Grammatopoulos G

Aims. This study of patients with osteoarthritis (OA) of the hip aimed to: 1) characterize the contribution of the hip, spinopelvic complex, and lumbar spine when moving from the standing to the sitting position; 2) assess whether abnormal spinopelvic mobility is associated with worse symptoms; and 3) identify whether spinopelvic mobility can be predicted from static anatomical radiological parameters. Patients and Methods. A total of 122 patients with end-stage OA of the hip awaiting total hip arthroplasty (THA) were prospectively studied. Patient-reported outcome measures (PROMs; Oxford Hip Score, Oswestry Disability Index, and Veterans RAND 12-Item Health Survey Score) and clinical data were collected. Sagittal spinopelvic mobility was calculated as the change from the standing to sitting position using the lumbar lordosis angle (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA), and acetabular anteinclination (AI) from lateral radiographs. The interaction of the different parameters was assessed. PROMs were compared between patients with normal spinopelvic mobility (10° ≤ ∆PT ≤ 30°) or abnormal spinopelvic mobility (stiff: ∆PT < ± 10°; hypermobile: ∆PT > ± 30°). Multiple regression and receiver operating characteristic (ROC) curve analyses were used to test for possible predictors of spinopelvic mobility. Results. Standing to sitting, the hip flexed by a mean of 57° (. sd. 17°), the pelvis tilted backwards by a mean of 20° (. sd. 12°), and the lumbar spine flexed by a mean of 20° (. sd. 14°); strong correlations were detected. There was no difference in PROMs between patients in the different spinopelvic mobility groups. Maximum hip flexion, standing PT, and standing AI were independent predictors of spinopelvic mobility (R. 2. = 0.42). The combined thresholds for standing was PT ≥ 13° and hip flexion ≥ 88° in the clinical examination, and had 90% sensitivity and 63% specificity of predicting spinopelvic stiffness, while SS ≥ 42° had 84% sensitivity and 67% specificity of predicting spinopelvic hypermobility. Conclusion. The hip, on average, accounts for three-quarters of the standing-to-sitting movement, but there is great variation. Abnormal spinopelvic mobility cannot be screened with PROMs. However, clinical and standing radiological features can predict spinopelvic mobility with good enough accuracy, allowing them to be used as reliable screening tools. Cite this article: Bone Joint J 2019;101-B:902–909


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 148 - 148
4 Apr 2023
Jørgensen P Kaptein B Søballe K Jakobsen S Stilling M
Full Access

Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation. Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01). The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 11 - 11
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Walter WL
Full Access

Iliopsoas tendonitis occurs in up to 30% of patients after hip resurfacing arthroplasty (HRA) and is a common reason for revision. The primary purpose of this study was to validate our novel computational model for quantifying iliopsoas impingement in HRA patients using a case-controlled investigation. Secondary purpose was to compare these results with previously measured THA patients. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitis, confirmed via the active hip flexion test in supine, and control patients without iliopsoas tendonitis, resulting in two cohorts of 12 patients. The CT scans were segmented, landmarked, and used to simulate the iliopsoas impingement in supine and standing pelvic positions. Three discrete impingement values were output for each pelvic position, and the mean and maximum of these values were reported. Cup prominence was measured using a novel, nearest-neighbour algorithm. The mean cup prominence for the symptomatic cohort was 10.7mm and 5.1mm for the asymptomatic cohort (p << 0.01). The average standing mean impingement for the symptomatic cohort was 0.1mm and 0.0mm for the asymptomatic cohort (p << 0.01). The average standing maximum impingement for the symptomatic cohort was 0.2mm and 0.0mm for the asymptomatic cohort (p << 0.01). Impingement significantly predicted the probability of pain in logistic regression models and the simulation had a sensitivity of 92%, specificity of 91%, and an AUC ROC curve of 0.95. Using a case-controlled investigation, we demonstrated that our novel simulation could detect iliopsoas impingement and differentiate between the symptomatic and asymptomatic cohorts. Interestingly, the HRA patients demonstrated less impingement than the THA patients, despite greater cup prominence. In conclusion, this tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 93 - 93
11 Apr 2023
de Angelis N Beaule P Speirs A
Full Access

Femoro-acetabular impingement involves a deformity of the hip joint and is associated with hip osteoarthritis. Although 15% of the asymptomatic population exhibits a deformity, it is not clear who will develop symptoms. Current diagnostic imaging measures have either low specificity or low sensitivity and do not consider the dynamic nature of impingement during daily activities. The goal of this study is to determine stresses in the cartilage, subchondral bone and labrum of normal and impinging hips during activities such as walking and sitting down. Quantitative CT scans were obtained of a healthy Control and a participant with a symptomatic femoral cam deformity (‘Bump’). 3D models of the hip were created from automatic segmentation of CT scans. Cartilage layers were added so the articular surface was the mid-line of the joint. Finite element meshes were generated in each region. Bone elastic modulus was assigned element-by-element, calculated from CT intensity converted to bone mineral density using a calibration phantom. Cartilage was modelled as poroelastic, E=0.467 MPa, v=0.167, and permeability 3×10. -16. m. 4. /N s. The pelvis was fixed while rotations and contact forces from Bergmann et al. (2001) were applied to the femur over one load cycle for walking and sitting in a chair. All analyses were performed in FEBio. High shear stresses were seen near the acetabular cartilage-labrum junction in the Bump model, up to 0.12 MPa for walking and were much higher than in the Control. Patient-specific modelling can be used to assess contact and tissue stresses during different activities to better understand the risk of degeneration in individuals, especially for activities that involve high hip flexion. The high stresses at the cartilage labrum interface could explain so-called bucket-handle tears of the labrum


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 19 - 19
1 Jul 2020
Innmann M Reichel F Schaper B Merle C Beaulé P Grammatopoulos G
Full Access

Aims. Our study aimed to 1) Describe the changes in spinopelvic mobility when transitioning from standing, to ‘relaxed-seated’ and thereafter to ‘deep-seated’ position and 2) Determine the change in spinopelvic mobility types 1 year post-THA compared to preoperatively. Methods. This prospective diagnostic cohort study followed 100 consecutive patients 1 year post-THA. Preoperatively and one year postoperatively, radiographic measurements were performed for the lumbar-lordosis-angle, pelvic tilt and pelvic-femoral-angle on lateral radiographs in the standing, ‘relaxed-seated’ and ‘deep-seated’ position (torso maximally leaning forward). Patients were classified according to their spinopelvic mobility type, according to the change in PT between the standing and relaxed-seated position (stiff:ΔPT<±10°, normal:10°≤ΔPT≤30°, hypermobile:ΔPT>±30°). Results. Compared to preoperatively, when moving from a standing to a relaxed-seated position, hip flexion increased by 10°±18, leading to less posterior pelvic tilt by 6°±11 and reduced lumbar spine flexion by 6°±11 (all p<0.001). Similarly, when moving from the standing to deep-seated position, hip flexion improved by a mean of 8°±22, leading to reduced lumbar spine flexion by a mean of 5°±8, whereas the change in pelvic tilt did not change compared to preoperatively (p=0.016, p<0.001, p=0.46). The distribution of spinopelvic mobility types 1 year postoperatively was significantly different compared to preoperatively, as the percentage of patients with stiff spinopelvic mobility increased from 16% to 43% (p<0.001). Conclusion. Hip flexion improved by 10° on average 1 year after total hip arthroplasty. Thus, slightly less compensatory posterior pelvic tilt and lumbar spine flexion was needed when taking a relaxed-seated position. When taking a deep-seated position, improved hip flexion required less lumbar spine flexion. However, these changes were small when being compared to preoperative variability of these parameters. Thus, individual spinopelvic mobility remains relatively unchanged 1 year after THA compared to preoperatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 8 - 8
11 Apr 2023
Piet J Vancleef S Mielke F Van Nuffel M Orozco G Korhonen R Lories R Aerts P Van Wassenbergh S Jonkers I
Full Access

Altered mechanical loading is a widely suggested, but poorly understood potential cause of cartilage degeneration in osteoarthritis. In rodents, osteoarthritis is induced following destabilization of the medial meniscus (DMM). This study estimates knee kinematics and contact forces in rats with DMM to gain better insight into the specific mechanisms underlying disease development in this widely-used model. Unilateral knee surgery was performed in adult male Sprague-Dawley rats (n=5 with DMM, n=5 with sham surgery). Radio-opaque beads were implanted on their femur and tibia. 8 weeks following knee surgery, rat gait was recorded using the 3D²YMOX setup (Sanctorum et al. 2019, simultaneous acquisition of biplanar XRay videos and ground reaction forces). 10 trials (1 per rat) were calibrated and processed in XMALab (Knörlein et al. 2016). Hindlimb bony landmarks were labeled on the XRay videos using transfer learning (Deeplabcut, Mathis et al. 2019; Laurence-Chasen et al. 2020). A generic OpenSim musculoskeletal model of the rat hindlimb (Johnson et al. 2008) was adapted to include a 3-degree-of-freedom knee. Inverse kinematics, inverse dynamics, static optimization of muscle forces, and joint reaction analysis were performed. In rats with DMM, knee adduction was lower compared to sham surgery. Ground reaction forces were less variable with DMM, resulting in less variability in joint external moments. The mediolateral ground reaction force was lower, resulting in lower hip adduction moment, thus less force was produced by the rectus femoris. Rats with DMM tended to break rather than propel, resulting in lower hip flexion moment, thus less force was produced by the semimembranosus. These results are consistent with lower knee contact forces in the anteroposterior and axial directions. These preliminary data indicate no overloading of the knee joint in rats with DMM, compared with sham surgery. We are currently expanding our workflow to finite element analysis, to examine mechanical cues in the cartilage of these rats (Fig1G)