Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 17 - 17
1 Sep 2012
Bone M Lord J Patil S Partington P Joyce T
Full Access

Background

Hemiarthroplasty of the hip involves the replacement of the femoral side of the joint with a metal prosthesis, resulting in metal-on-cartilage articulation. The two most common types of hemiarthroplasty used are the Austin Moore and the Thomson, both of which are available in either Titanium (Ti) or cobalt chromium (CoCr). Hemiarthroplasty may be more cost effective in elderly patients who have lower life expectancy and are less active.

Materials and Methods

Three Ti and two CoCr hemiarthroplasty components were obtained following revision surgery. Four had an articulating diameter of 44mm and the other was 46mm diameter. These five hemiarthroplasties were analysed using a Mitutoyo LEGEX322 co-ordinate measuring machine (CMM) (manufacturer's claimed scanning accuracy of 0.8μm). In each case a wear map was generated and the wear volume from the articulating surface was calculated using a bespoke MATLAB program.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 61 - 61
1 Mar 2021
Schemitsch E
Full Access

Displaced femoral neck fractures can have devastating impacts on quality of life and patient function. Evidence for optimal surgical approach is far from definitive. The Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemi-Arthroplasty (HEALTH) trial aimed to evaluate unplanned secondary procedures following total hip arthroplasty (THA) versus hemi-arthroplasty (HA) within two years of initial surgery for displaced femoral neck fractures. Secondary objectives evaluated differences in patient function, health-related quality of life, mortality, and hip-related complications HEALTH is a large randomized controlled trial that included 1,495 patients across 81 centers in 10 countries. Patients aged 50 years or older with displaced femoral neck fractures received either THA or HA. Participants were followed for 24 months post-fracture and a Central Adjudication Committee adjudicated fracture eligibility, technical placement of prosthesis, additional surgical procedures, hip-related complications, and mortality. The primary analyses were a Cox proportional hazards model with time to the primary study endpoint as the outcome and THA versus HA as the independent variable. Using multi-level linear models with three levels (centre, patient, and time), with patient and centre entered as random effects, the effect of THA versus HA on quality of life (Short Form-12 (SF-12) and EQ-5D), function (Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)), and mobility (Timed Up and Go Test (TUG)) were estimated separately.

The majority of patients were female (70.1%), 70 years of age or older (80.2%), and able to ambulate without the aid of an assistive device before their fracture (74.4%), and the injury in the majority of the patients was a subcapital femoral neck fracture (61.9%). The primary end point occurred in 57 of 718 patients (7.9%) who were randomly assigned to THA and 60 of 723 patients (8.3%) who were randomly assigned to HA (hazard ratio, 0.95; 95% confidence interval [CI], 0.64 to 1.40; p=0.79). Hip instability or dislocation occurred in 34 patients (4.7%) assigned to total hip arthroplasty and 17 patients (2.4%) assigned to hemi- arthroplasty (hazard ratio, 2.00; 99% CI, 0.97 to 4.09). Function, as measured with the total WOMAC total score, pain score, stiffness score, and function score, modestly favored THA over HA. Mortality was similar in the two treatment groups (14.3% among the patients assigned to THA and 13.1% among those assigned to HA, p=0.48). Serious adverse events occurred in 300 patients (41.8%) assigned to THA and in 265 patients (36.7%) assigned to HA.

Among independently ambulating patients with displaced femoral neck fractures, the incidence of secondary procedures did not differ significantly between patients who were randomly assigned to undergo THA and those who were assigned to undergo HA, and THA provided a clinically unimportant improvement over HA in function and quality of life over 24 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 31 - 31
1 Sep 2012
Hossain M Andrew G
Full Access

Introduction

Following National patient safety alert on cement use in hip fracture surgery, we investigated the incidence and pattern of 72 hours peri-operative mortality after hip fracture surgery in a District General Hospital.

Methods

We reviewed all patients who had hip fracture surgery between 2005-April, 2010. We recorded demographic variables, type of fracture, implant used, medical co-morbidity, seniority of operating surgeon and anaesthetist, peri-operative haemodynamic status, time and cause of death.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 85 - 85
1 Jan 2016
Suh Y Nho J Park J Lee Y Ha Y Koo K
Full Access

Introduction

In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty(BH), compression hip screw(CHS) and proximal femur nail antirotatory(PFNA) in treating comminuted intertrochanteric fractures(AO type, A2(21, 22, 23))

Materials and Methods

We retrospectively evaluated total 150 patients(BH:50, CHS:50, PFNA: 50) who were operated due to intertrochanteric fractures from March 2010 to Dec 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris hip score, ability of ambulation(Koval stage), visual analogue scale and radiologic limb length discrepancy(shortening). Landmark and radiologic length was checked.

–A: postoperative length

–A’: POD 1year

–B: immediate posteopative contralateral length(from hip center to distal tip of lesser trochanter)

–B’: POD 1year contralateral length(from hip center to distal tip of lesser trochanter)

Limb length(shortening) was adjusted considering difference of magnification

= {A × (B’/B)}− A’


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 27 - 27
1 Dec 2022
Falsetto A Bohm E Wood G
Full Access

Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian Registry Study where 68447 patients were identified for having a hip hemiarthroplasty from 2012-2020. This is a retrospective cohort study, identifying patients that had cementless or cemented hip hemiarthroplasty. The surgeons who performed the procedures were linked to the procedure Total Hip Replacement. Individuals were categorized as experienced hip surgeons or not based on whether they performed 50 hip replacements a year. Identifying high volume surgeon (>50 cases/year) and low volume (<50 cases/year) surgeons. Hazard ratios adjusted for age and sex were performed for risk of revision over this 8-year span. A p-value <0.05 was deemed significant. For high volume surgeons, cementless fixation had a higher revision risk than cemented fixation, HR 1.29 (1.05-1.56), p=0.017. This pattern was similar for low volume surgeons, with cementless fixation having a higher revision risk than cemented fixation, HR 1.37 (1.11-1.70) p=0.004 We could not detect a difference in revision risk for cemented fixation between low volume and high volume surgeons; at 0-1.5 years the HR was 0.96 (0.72-1.28) p=0.786, and at 1.5+ years the HR was 1.61 (0.83-3.11) p=0.159. Similarly, we could not detect a difference in revision risk for cementless fixation between low volume and high volume surgeons, HR 1.11 (0.96-1.29) p=0.161. Using large registry data, cemented hip hemiarthroplasty has a significant lower revision rate than the use of cementless stems even when surgeons are stratified to high and low volume. Low volume surgeons who use uncemented prostheses have the highest rate of revision. The low volume hip surgeon who cements has a lower revision rate than the high volume cementless surgeon. The results of this study should help to guide surgeons that no matter the level of experience, using a cemented hip hemiarthroplasty for acute femoral neck fracture is the safest option. That high volume surgeons who perform cementless hemiarthroplasty are not immune to having revisions due to their technique. Increased training and education should be offered to surgeons to improve comfort when using this technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 1 - 1
1 Dec 2022
Falsetto A Bohm E Wood G
Full Access

Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian Registry Study where 68447 patients were identified for having a hip hemiarthroplasty from 2012-2020. This is a retrospective cohort study, identifying patients that had cementless or cemented hip hemiarthroplasty. The surgeons who performed the procedures were linked to the procedure Total Hip Replacement. Individuals were categorized as experienced hip surgeons or not based on whether they performed 50 hip replacements a year. Identifying high volume surgeon (>50 cases/year) and low volume (<50 cases/year) surgeons. Hazard ratios adjusted for age and sex were performed for risk of revision over this 8-year span. A p-value <0.05 was deemed significant. For high volume surgeons, cementless fixation had a higher revision risk than cemented fixation, HR 1.29 (1.05-1.56), p=0.017. This pattern was similar for low volume surgeons, with cementless fixation having a higher revision risk than cemented fixation, HR 1.37 (1.11-1.70) p=0.004 We could not detect a difference in revision risk for cemented fixation between low volume and high volume surgeons; at 0-1.5 years the HR was 0.96 (0.72-1.28) p=0.786, and at 1.5+ years the HR was 1.61 (0.83-3.11) p=0.159. Similarly, we could not detect a difference in revision risk for cementless fixation between low volume and high volume surgeons, HR 1.11 (0.96-1.29) p=0.161. Using large registry data, cemented hip hemiarthroplasty has a significant lower revision rate than the use of cementless stems even when surgeons are stratified to high and low volume. Low volume surgeons who use uncemented prostheses have the highest rate of revision. The low volume hip surgeon who cements has a lower revision rate than the high volume cementless surgeon. The results of this study should help to guide surgeons that no matter the level of experience, using a cemented hip hemiarthroplasty for acute femoral neck fracture is the safest option. That high volume surgeons who perform cementless hemiarthroplasty are not immune to having revisions due to their technique. Increased training and education should be offered to surgeons to improve comfort when using this technique


Bone & Joint Open
Vol. 4, Issue 9 | Pages 704 - 712
14 Sep 2023
Mercier MR Koucheki R Lex JR Khoshbin A Park SS Daniels TR Halai MM

Aims

This study aimed to investigate the risk of postoperative complications in COVID-19-positive patients undergoing common orthopaedic procedures.

Methods

Using the National Surgical Quality Improvement Programme (NSQIP) database, patients who underwent common orthopaedic surgery procedures from 1 January to 31 December 2021 were extracted. Patient preoperative COVID-19 status, demographics, comorbidities, type of surgery, and postoperative complications were analyzed. Propensity score matching was conducted between COVID-19-positive and -negative patients. Multivariable regression was then performed to identify both patient and provider risk factors independently associated with the occurrence of 30-day postoperative adverse events.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 22 - 22
1 Aug 2020
Sandoval C Di Bella J Dragan A de Guia N Webster G Dunbar MJ Bohm E Yu C
Full Access

Revision is a key negative outcome of joint replacements. The purpose of this abstract is to present revision risk curves for hip and knee replacements based on the most recently available national data sources. Having a better understanding of determinants of revision risk can help inform clinical and health care system improvements. We explored revision risk of primary joint replacement stratified by key clinical, prosthesis, and surgeon-level factors using data from three databases managed by CIHI: the Canadian Joint Replacement Registry (CJRR), the Discharge Abstract Database, and the National Ambulatory Care Reporting System. To investigate early revisions, we used Kaplan-Meier analysis stratified by demographic factors to determine the risk of revision within up to five years of primary surgery. This analysis identified the primary cohort from the CJRR from April 1, 2012 to March 31, 2017 and was limited to mandatory reporting provinces (British Columbia, Manitoba and Ontario) to ensure maximal coverage of prosthesis information. Bearing surface was obtained from the International Prosthesis Library maintained by the International Consortium of Orthopaedic Registries (ICOR) and the International Society of Arthroplasty Registers (ISAR). The total revision risk cohort contained 283,620 primary surgeries, of which 5,765 (2%) had at least one revision. For total hip arthroplasties, revision risk at the end of the follow-up period did not differ by age, by sex or across bearing surface (metal on cross-linked polyethylene [XLPE], ceramic on XLPE, ceramic on ceramic, metal on non-cross-linked polyethylene). For hemiarthroplasties in hip fracture patients, cement fixation was significantly associated with decreased revision risk. Surgeon volume had a positive effect on survivorship with cementless fixation (2.7% at one year [95% CI 2.3%, 3.1%] for high-volume vs 3.2% [2.7%, 3.7%] for low-volume). However, surgeon volume did not have an effect on survivorship with cemented fixation (2% at one year [95% CI 1.3%, 2.6%] for high-volume vs. 2% [1.4%, 2.6%] for low-volume). For total knee replacements, revision risk increased with decreasing age and male sex. For patients aged 75 and older, four-year revision risks were 1.5% (95% CI 1.3%, 1.7%) for women and 2.0% (1.7%, 2.3%) for men, but for patients under 55 years old, they were 4.3% (3.7%, 5%) for women and 5.9% (4.9%, 6.9%) for men. Additional results from the upcoming 2019 CJRR annual report, including data up to March 31, 2018, will be presented. Revisions represent a key failure of the primary replacement, they are costly to the health care system and negatively affect patients' quality of life. CJRR's coverage is currently 72%, increased coverage and follow-up time will allow increasingly comprehensive reporting on hip and knee prostheses in Canada. Future work in this area involves exploring additional prosthesis attributes for stratification of revision risk curves and calculation of hazards ratios adjusted by age and sex


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 148 - 148
1 Feb 2017
Groves D Fisher J Williams S
Full Access

Introduction. Geometric variations of the hip joint can give rise to abnormal joint loading causing increased stress on the articular cartilage, which may ultimately lead to degenerative joint disease. In-vitro simulations of total hip replacements (THRs) have been widely reported in the literature, however, investigations exploring the tribology of two contacting cartilage surfaces, and cartilage against metal surfaces using complete hip joint models are less well reported. The aim of this study was to develop an in-vitro simulation system for investigating and comparing the tribology of complete natural hip joints and hemiarthroplasties with THR tribology. The simulation system was used to assess natural porcine hip joints and porcine hemiarthroplasty hip joints. Mean friction factor was used as the primary outcome measure to make between-group comparisons, and comparisons with previously published tribological studies. Method. In-vitro simulations were conducted on harvested porcine tissue. A method was developed enabling natural acetabula to be orientated with varying angles of version and inclination, and natural femoral heads to be potted centrally with different orientations in all three planes. Acetabula were potted with 45° of inclination and in the complete joint studies, natural femoral heads were anatomically matched and aligned (n=5). Hemiarthroplasty studies (n=5) were conducted using cobalt chrome (CoCr) heads mounted on a spigot (Figure 1), size-matched to the natural head. Natural tissue was fixed using PMMA (polymethyl methacrylate) bone cement. A pendulum friction simulator (Simulator Solutions, UK), with a dynamic loading regime of 25–800N, ± 15° flexion-extension (FE) at 1 Hertz was used. The lubricant was a 25% (v/v) bovine serum. Axial loading and motion was applied through the femoral head and frictional torque was measured using a piezoelectric transducer, from which the friction factor was calculated. Results. The correct anatomical orientation and positioning was achieved enabling in-vitro simulation testing to be conducted on hemiarthroplasty and complete hip joint samples for two-hours. Mean friction increased rapidly followed by a continued gradual increase to ≈0.03 ± 0.00 in the complete joints, with the hemiarthroplasty group plateauing at ≈0.05 ± 0.01 (Figure 2). Mean friction factor was significantly lower (t-test; p < 0.05) in the complete natural joint group. Discussion. An in-vitro simulation system for the natural hip joint with controlled orientation of the femur and acetabulum was successfully developed and used to measure friction in complete porcine hip joints and porcine hip hemiarthroplasties. A non-linear increase in friction indicative of biphasic lubrication was observed in both groups with slower exudation of fluid from the complete joints compared to the hemiarthroplasties, inferring a quicker move towards solid-phase lubrication. Higher friction in the hemiarthroplasties, which was similar to that measured in-vitro in metal-on-polyethylene THRs, was most likely due to variable clearances between the non-conforming spherical metal head and aspherical acetabulum, causing poorer congruity and distribution of the load. This could in time lead to abrasive wear and cartilage degradation. This methodology could have an important role when investigating associations between hip geometric variations, interventions for hip disease/pathology, and risk factors for cartilage degeneration


Bone & Joint Open
Vol. 1, Issue 6 | Pages 198 - 202
6 Jun 2020
Lewis PM Waddell JP

It is unusual, if not unique, for three major research papers concerned with the management of the fractured neck of femur (FNOF) to be published in a short period of time, each describing large prospective randomized clinical trials. These studies were conducted in up to 17 countries worldwide, involving up to 80 surgical centers and include large numbers of patients (up to 2,900) with FNOF. Each article investigated common clinical dilemmas; the first paper comparing total hip arthroplasty versus hemiarthroplasty for FNOF, the second as to whether ‘fast track’ care offers improved clinical outcomes and the third, compares sliding hip with multiple cancellous hip screws. Each paper has been deemed of sufficient quality and importance to warrant publication in The Lancet or the New England Journal of Medicine. Although ‘premier’ journals, they only occationally contain orthopaedic studies and thus may not be routinely read by the busy orthopaedic/surgical clinician of any grade. It is therefore our intention with this present article to accurately summarize and combine the results of all three papers, presenting, in our opinion, the most important clinically relevant facts.

Cite this article: Bone Joint Open 2020;1-6:198–202.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 662 - 667
1 May 2008
Strauss EJ Egol KA Alaia M Hansen D Bashar M Steiger D

This study was undertaken to evaluate the safety and efficacy of retrievable inferior vena cava filters in high-risk orthopaedic patients. A total of 58 patients had a retrievable inferior vena cava filter placed as an adjunct to chemical and mechanical prophylaxis, most commonly for a history of previous deep-vein thrombosis or pulmonary embolism, polytrauma, or expected prolonged immobilisation. In total 56 patients (96.6%) had an uncomplicated post-operative course. Two patients (3.4%) died in the peri-operative period for unrelated reasons.

Of the 56 surviving patients, 50 (89%) were available for follow-up. A total of 32 filters (64%) were removed without complication at a mean of 37.8 days (4 to 238) after placement. There were four filters (8%) which were retained because of thrombosis at the filter site, and four (8%) were retained because of incorporation of the filter into the wall of the inferior vena cava. In ten cases (20%) the retrievable filter was left in place to continue as primary prophylaxis. No patient had post-removal thromboembolic complications.

A retrievable inferior vena cava filter, as an adjunct to chemical and mechanical prophylaxis, was a safe and effective means of reducing the acute risk of pulmonary embolism in this high-risk group of patients. Although most filters were removed without complications, thereby avoiding the long-term complications that have plagued permanent indwelling filters, a relatively high percentage of filters had to be left in situ.