Full Access

General Orthopaedics

Increased risk of peri-operative mortality after cemented hemiarthroplasty for hip fracture surgery

British Orthopaedic Association/Irish Orthopaedic Association Annual Congress (BOA/IOA)



Abstract

Introduction

Following National patient safety alert on cement use in hip fracture surgery, we investigated the incidence and pattern of 72 hours peri-operative mortality after hip fracture surgery in a District General Hospital.

Methods

We reviewed all patients who had hip fracture surgery between 2005-April, 2010. We recorded demographic variables, type of fracture, implant used, medical co-morbidity, seniority of operating surgeon and anaesthetist, peri-operative haemodynamic status, time and cause of death.

Results

Over a 64 month period 15 cases were identified. Peri-operative death (PAD) was 1% (15/1402). 4/15 patients died intra-operatively. PAD was highest following Exeter Trauma Stem (ETS) implantation (5/85, 6%) and nil following Bipolar arthroplasty, Austin-Moore arthroplasty (AMA) or Cannulated screw fixation. PAD following total hip arthroplasty was 4% (1/25), Thompson's hemi-arthroplasty 2% (3/191), and Dynamic Hip Screw fixation 1% (6/695). Overall mortality after cemented implant was 2%. ETS implantation led to significantly increased peri-operative mortality compared to AMA (p=0.004). Operations were performed by both trainees (12) and Consultants (3). Both trainees (9) and Consultants (6) anaesthetised the patients. None of the patients belonged to ASA I or II (ASA III 6 and IV 9). All patients had significant cardio-vascular or pulmonary co-morbidity (Ca Lung 2, pulmonary fibrosis 1, end stage COAD 1, AF 6). Cemented implant insertion was followed by immediate haemodynamic collapse and death in 4/15, intra-operative haemodynamic instability in 1/15 and peri-operative instability in 5/15. Post-mortem was performed in 5/15: 2/5 were Pulmonary Embolism (PE), 2/5 bronchopneumonia and 1/5 Myocardial infarction (MI). 4/15 had suspected MI and 1/15 suspected PE.

Conclusion

There was 1% risk of peri-operative death after hip fracture surgery. This risk was increased following cemented hemiarthroplasty and highest after ETS implantation. Risk was exacerbated in patients with pre-existing cardiovascular morbidity and independent of the seniority of the surgeon or the anaesthetist.