Abstract. Background. 1. 63,284 patients presented with neck of femur fractures in England in 2020 (NHFD report 2021)2. To maximise theatre efficiency during the first wave of COVID-19, NHSE guidance recommended the use of HA for most patients requiring arthroplasty.3. The literature reports an incidence of
Hip precautions are currently practiced in three-quarters of trauma hospitals in the UK, despite national recommendations from the ‘Blue Book’ not stating it as a requirement. Valuable therapist time is utilised alongside the need for specialised equipment, which can potentially delay discharge whilst it is being arranged.
Objective of this study was to explore the current practice of the use of hip precautions on discharge following
Introduction and Objective. Dislocation of a hip
Between 2016–2019, 4 patients developed hip infections post-hemiarthroplasty. However, between 2020–2021 (Covid-19 pandemic period), 6 patients developed hip infections following hip
Abstract. Objectives. Current use of hard biomaterials such as cobalt-chrome alloys or ceramics to articulate against the relatively soft, compliant native cartilage surface reduces the joint contact area by up to two thirds. This gives rise to high and abnormal loading conditions which promotes degradation and erosion of the mating cartilage leading to pain, stiffness, and loss of function. Biomimetic soft lubrication strategies have been developed by grafting hydrophilic polymers onto substrates to form a gel-type surface. Surface grafted gels mimic the natural mechanisms of friction dissipation in synovial joints, showing a promising potential for use in
Introduction and Objective. Interest for direct anterior approach (DAA) in hip
Contrary to NICE guidance there remains a role for Austin-Moore
This study compared the effect of a computer-assisted and a traditional surgical technique on the kinematics of the glenohumeral joint during passive abduction after
Abstract. Objectives. Up to 19% of patients who undergo surgery for an acute hip fracture are readmitted to the hospital within three months of the index operation. We aimed to identify risk factors for unplanned clinic attendance, readmission, and mortality within the first 12 months postoperatively and subsequently determine if there is a role for routine follow-up. Methods. Patients greater than 65 years old who underwent hip
Background. Severe hallux rigidus can be treated with total or hemi arthroplasty to preserve motion in the 1st metatarsophalangeal joint (MTPJ). Decreased dorsiflexion impairs the rollover motion of the 1st MTPJ and recent studies of patients with 1st MTPJ osteoarthritis show increased plantar forces on the hallux. Objectives. Our aim was to examine the plantar force variables under the hallux and the 1st, 2nd, and 3rd – 5th distal metatarsal head (MH) on patients operated with a proximal
Hemi-arthroplasty (HA) as a treatment for fractured neck of femur has slightly increased since 2019 and remarkably after the COVID pandemic. The main drawback of the treatment is ongoing cartilage deterioration that may require revision to THR. This study assessed cartilage surface damage in hip HA by reproducing anatomical motion and loading conditions in a hip simulator.Abstract
BACKGROUND
OBJECTIVE
The surgical treatment options for patients who have sustained an intra-capsular hip fracture can vary depending on a number of patient and fracture related factors. Currently most national guidelines support the use of cemented prostheses for patient undergoing
Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the Thompson implant when performing hip
The ‘cement reaction’ is a recognised cardio-respiratory response to methylmethacrylate bone cement, characterised by hypotension, reduced cardiac output, and on occasion fatal circulatory collapse. It is seen in 0.5-1% of cemented hip arthroplasties during the insertion and pressurisation of cement into the femur, and is believed to be secondary to marrow thromboembolism, the vasodilatory effect of methylmethacrylate, or a combination of the two. A number of steps, within the operating surgeon's control, can be undertaken to reduce the risk of the ‘cement reaction’ occurring. An e-mail based questionnaire was sent to all trainees and consultants in the West of Scotland containing eight questions relating to cementing technique when performing
The use of a composite osteochondral device for simulating partial
Bipolar hemiarthroplasty(BPHA) for displaced intracapsular neck of femur fractures(DICNOF) is a controversial topic as conflicting evidence exists. The most common reason for revision to total hip arthroplasty(THA) from BPHA is acetabular erosion. In our study, we sought to quantify the direction of migration of the bipolar head within the first 3 years post-operatively. A proportional index in the horizontal and vertical planes of the pelvis were used to quantify migration. This method removed the need to account for magnification and rotation of the radiographs.Abstract
Introduction
Methods
Currently, the cement being used for
The surgical treatment options for patients who have sustained an intra-capsular hip fracture can vary depending on a number of patient and fracture related factors. Currently most national guidelines support the use of cemented prostheses for patient undergoing hemi-arthroplasty surgery. Uncemented prostheses are commonly used for a variety of indications including those patients who have significant medical co-morbidities. To determine whether cemented hemi-arthroplasty is associated with a higher post operative mortality when compared to uncemented procedures. Data was extracted from the Scottish SMR01 database from 01/04/1997 from all patients who were admitted to hospital after sustaining a hip fracture. We investigated mortality at day 1, 2, 4, 7, 30, 120 and 1 year from surgery vs. that on day 0. In order to control for the effects of confounding variables between patients cohorts, 12 case-mix variable were used to construct a multivariable logistic regression analysis model to determine the independent effect of prosthesis fixation method. There were 64,979 patients were included in the study. Mortality for osteosynthesis of extra-capsular fractures was consistently lower when compared to that for surgical procedures for intra-capsular fractures. At day 0, uncemented hemi-arthroplasty operations had a lower associated mortality (p<0.001) when compared to cemented implant designs. Unadjusted figures showed an increased mortality equal to 1 extra death per 424 procedures. By day 1 this had become 1 extra death per 338 procedures. By day 7 cumulative mortality was less for cemented than for uncemented procedures though this did not reach significance until day 120. When compared to uncemented fixation techniques, cemented
Summary Statement. Total hip arthroplasty and hemi-arthroplasty are becoming increasingly popular in the treatment of femoral neck fractures in the United States. Both appear to be safe and effective treatment options, with rare acute adverse events and low mortality. Introduction. Femoral neck fractures are one of the most frequent orthopaedic injuries seen in the United States (US). Total hip arthroplasty (THA) and
This study evaluated the effect on movement under load of three different techniques for re-attachment of the tuberosities of the humerus using test sawbones. In the first, the tuberosities were attached both to the shaft and to each other, with one cerclage suture through the anterior hole in the prosthesis. The second technique was identical except for omission of the cerclage suture and in the third the tuberosities were attached to the prosthesis and to the shaft. An orthogonal photogrammetric system allowed all segments to be tracked in a 3D axis system. The humeri were incrementally-loaded in abduction, and the 3D linear and angular movements of all segments were calculated. Displacement between the tuberosities and the shaft was measured. The first and second techniques were the most stable constructs, with the third allowing greater separation of fragments and angular movement. Separation at the midpoint of the tuberosities was significantly greater using the latter technique (p <
0.05). The cerclage suture added no further stability to the fixation.