Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 2 - 2
7 Nov 2023
du Plessis JG Koch O le Roux T O'Connor M
Full Access

In reverse shoulder arthroplasty (RSA), a high complication rate is noted in the international literature (24.7%), and limited local literature is available. The complications in our developing health system, with high HIV, tuberculosis and metabolic syndrome prevalence may be different from that in developed health systems where the literature largely emanates from. The aim of this study is to describe the complications and complication rate following RSA in a South African cohort. An analytical, cross-sectional study was done where all patients’ who received RSA over an 11 year period at a tertiary hospital were evaluated. One-hundred-and-twenty-six primary RSA patients met the inclusion criteria and a detailed retrospective evaluation of their demographics, clinical variables and complication associated with their shoulder arthroplasty were assessed. All fracture, revision and tumour resection arthroplasties were excluded, and a minimum of 6 months follow up was required. A primary RSA complication rate of 19.0% (24/126) was noted, with the most complications occurring after 90 days at 54.2% (13/24). Instability was the predominant delayed complication at 61.5% (8/13) and sepsis being the most common in the early days at 45.5% (5/11). Haematoma formation, hardware failure and axillary nerve injury were also noted at 4.2% each (1/24). Keeping in mind the immense difference in socioeconomical status and patient demographics in a third world country the RSA complication rate in this study correlates with the known international consensus. This also proves that RSA is still a suitable option for rotator cuff arthropathy and glenohumeral osteoarthritis even in an economically constrained environment like South Africa


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 56 - 56
7 Nov 2023
Mazibuko T
Full Access

Sacral fractures are often underdiagnosed, but are frequent in the setting of pelvic ring injuries. They are mostly caused by high velocity injuries or they can be pathological in aetiology. We sought to assess the clinical outcomes of the surgically treated unstable sacral fractures, with or without neurological deficits. unstable sacral fractures were included in the study. Single centre, prospectively collected data, retrospective review of patients who sustained vertically unstable fractures of the sacrum who underwent surgical fixation. out of a total of 432 patients with pelvis and acetabulum injuries. fifty six patients met the inclusion criteria. 18 patients had sustained zone one injuries. 14 patients had zone 2 injuries and 10 patients had zone 3 injurie. Operative fixation was performed percutaneously using cannulated screws in 18 patients.. Open fixation of the sacrum using the anterior approach in 6 patients. Posterior approach was indicates in all 10 of the zone 3 injuries of the sacrum. While in 4 patients, combined approaches were used. 3 patients had decompression and spinopelvic fixation. Neurological deficits were present in 16% of the patients. 2 patients presented with neurgenic bladder. Of the 4 patients who had neurological fall out, 3 resolved with posterior decompression and posterior fixation. All 4 neurological deficits were due to taction or compression of the nerve roots. No hardware failures or non unions observed. The rate of neurological deficit was related more to the degree of pelvic ring instability than to a particular fracture pattern. Low rates of complications and successful surgical treatment of sacral fractures is achiavable. Timeous accurate diagnosis mandatory


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 19 - 19
23 Feb 2023
Sandow M Cheng Z
Full Access

This paper presents an ongoing review of the use of a wedge-shaped porous metal augments in the shoulder to address glenoid retroversion as part of anatomical total shoulder arthroplasty (aTSA). Seventy-five shoulders in 66 patients (23 women and 43 men, aged 42 to 85 years) with Walch grade B2 or C glenoids underwent porous metal glenoid augment (PMGA) insertion as part of aTSA. Patients received either a 15º or 30º PMGA wedge (secured by screws to the native glenoid) to correct excessive glenoid retroversion before a standard glenoid component was implanted using bone cement. Neither patient-specific guides nor navigation were used. Patients were prospectively assessed using shoulder functional assessments (Oxford Shoulder Score [OSS], American Shoulder and Elbow Standardized Shoulder Assessment Form [ASES], visual analogue scale [VAS] pain scores and forward elevation [FE]) preoperatively, at three, six, and 12 months, and yearly thereafter, with similar radiological surveillance. Forty-nine consecutive series shoulders had a follow-up of greater than 24 months, with a median follow-up of 48 months (range: 24–87 months). Median outcome scores improved for OSS (21 to 44), ASES (24 to 92), VAS (7 to 0), and FE (90º to 140º). Four patients died, but no others were lost to follow-up. Apart from one infection at 18 months postoperatively and one minor peg perforation, there were no complications, hardware failures, implant displacements, significant lucency or posterior re-subluxations. Radiographs showed good incorporation of the wedge augment with correction of glenoid retroversion from median 22º (13º to 46º) to 4º. All but four glenoids were corrected to within the target range (less than 10º retroversion). The porous metal wedge-shaped augments effectively addressed posterior glenoid deficiency as part of aTSA for rotator cuff intact osteoarthritis, producing satisfactory clinical outcomes with no signs of impending future failure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 29 - 29
1 Apr 2022
Jido JT Rodham P Giannoudis V Andronic A Harwood P
Full Access

Introduction. Routine radiographs in the follow-up of circular frames is commonplace, however the effect on clinical decision making is unclear. Previous work locally has suggested that >95% of radiographs, particularly at early time points, do not affect clinical management. This study was conducted to assess the impact of a transition to early remote follow-up on circular frame patients with limited radiographic assessment. Materials and Methods. Patients were identified from a prospective limb reconstruction database. Data were collected including the number of clinic appointments, type of clinic appointment, number of radiographs performed, and impact this had on clinical management. This was compared to our previous cohort of 85 patients undergoing standard follow-up. Results. Fourteen patients were eligible for inclusion (mean age 45, range 26–75). Circular frames were indicated for trauma (12), or limb reconstruction (2). Following introduction of remote follow-up, the mean number of face-to-face appointments reduced from 6.1 to 1.7 to the point of frame removal. Conversion from telephone follow-up to face-to-face follow-up was required in just one case where hardware failure occurred. The number of radiographs during treatment was reduced from a mean of 22 to 11 (range 4–20). Conclusions. Remote follow-up of circular frame patients was associated with significantly fewer radiographs and face-to-face appointments, without significantly increasing complications. We believe this is a safe and effective method of follow-up, optimising resource use in line with the NHS long term plan. Data collection is ongoing, and a larger cohort would be available for presentation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 37 - 37
1 Mar 2021
Bouchard C Chan R Bornes T Beaupre L Silveira A Hemstock R
Full Access

The purpose of this study is to determine the re-operation rate following plate fixation of the olecranon with contoured anatomic plates. Plate fixation of the olecranon allows for management of different fracture patterns as well as osteotomies with anatomic reduction and stable fixation for early elbow mobilization. However, olecranon hardware prominence can be troublesome. Our hypothesis was with the newer generation of low profile contoured anatomic plates, the rate of hardware removal should be lower compared to previously described literature. Retrospective review for patients treated with operative fixation of the olecranon between 2010 and 2015 in the Edmonton zone was identified using population level administrative data. Radiographic screening of these patients was then carried out to identify those who received plate fixation. Fracture patterns were also characterized. Chart reviews followed to determine the indications for re-operation and other post-operative complications. Main outcome measures were re-operation rate and their indications, including hardware prominence. During the screening process, 600 surgically treated olecranon patients were identified and 321 patients were found to have plate fixation of the olecranon. Chart review determined 90 patients had re-operations demonstrating a 28% re-operation rate. Re-operation due to hardware prominence was found to be 15.6%. Other indications included hardware failure (5.3%), infection (2.8%), or contracture (2.8%). Compared to patients that did not require re-operation, the re-operation group had a higher incidence of Type III olecranon fractures (17.4% vs 8.4%, p = 0.036) and Monteggia pattern injuries (13.5% vs 4.9%, p = 0.008). Recent heteregenous data suggests the hardware removal rate related to implant prominence is between 17–54%. Compared to the literature, this study demonstrated a lower rate at 15.6% with contoured anatomic plating. Also, those with more complex fracture patterns were more likely to require re-operation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 54 - 54
1 Nov 2016
Birch C Blankstein M Bartlett C
Full Access

Periprosthetic femoral shaft fractures are a significant complication of total hip arthroplasty. Plate osteosynthesis with or without onlay strut allograft has been the mainstay of treatment around well-fixed stems. Nonunions are a rare, challenging complication of this fixation method. The number of published treatment strategies for periprosthetic femoral nonunions are limited. In this series, we report the outcomes of a novel orthogonal plating surgical technique for addressing nonunions in the setting of Vancouver B1 and C-type periprosthetic fractures that previously failed open reduction internal fixation (ORIF). A retrospective chart review of all patients from 2010 to 2014 with Vancouver B1/C total hip arthroplasty periprosthetic femoral nonunions was performed. All patients were treated primarily with ORIF. Nonunion was defined as no radiographic signs of fracture healing nine months post-operatively, with or without hardware failure. Exclusion criteria included open fractures and periprosthetic infections. The technique utilised a mechanobiologic strategy of atraumatic exposure, resection of necrotic tissue, bone grafting with adjuvant recombinant growth factor and revision open reduction internal fixation. Initially, compression was achieved using an articulated tensioning device and application of an anterior plate. This was followed by locked lateral plating. Patients remained non-weight bearing for eight weeks. Six Vancouver B1/C periprosthetic femoral nonunions were treated. Five patients were female with an average age of 80.3 years (range 72–91). The fractures occurred at a mean of 5.8 years (range 1–10) from their initial arthroplasty procedure. No patients underwent further revision surgery; there were no wound dehiscence, hardware failures, infections, or surgical complications. All patients had a minimum of nine months follow up (mean 16.6, range 9–36). All fractures achieved osseous union, defined as solid bridging callus over at least two cortices and pain free, independent ambulation, at an average of 24.4 weeks (range 6.1–39.7 weeks). To our knowledge, this is the first case series describing 90–90 locked compression plating using modern implants for periprosthetic femoral nonunions. This is a rare but challenging complication of total hip arthroplasty and we present a novel solution with satisfactory preliminary outcomes. Orthogonal locked compression plating utilising an articulated tensioning device and autograft with adjuvant osteoinductive allograft should be considered in periprosthetic femur fractures around a well-fixed stem. Further biomechanical and clinical research is needed to improve our treatment strategies in this population


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 43 - 43
1 Jul 2020
Rollick N Bear J Diamond O Helfet D Wellman D
Full Access

Dual plating of the medial and lateral distal femur has been proposed to reduce angular malunion and hardware failure secondary to delayed union or nonunion. This strategy improves the strength and alignment of the construct, but it may compromise the vascularity of the distal femur paradoxically impairing healing. This study investigates the effect of dual plating versus single plating on the perfusion of the distal femur. Ten matched pairs of fresh-frozen cadaveric lower extremities were assigned to either isolated lateral plating or dual plating of a single limb. The contralateral lower extremity was used as a matched control. A distal femoral locking plate was applied to the lateral side of ten legs using a standard sub-vastus approach. Five femurs had an additional 3.5mm reconstruction plate applied to the medial aspect of the distal femur using a medial sub-vastus approach. The superficial femoral artery and the profunda femoris were cannulated at the level of the femoral head. Gadolinium MRI contrast solution (3:1 gadolinium to saline ration) was injected through the arterial cannula. High resolution fat-suppressed 3D gradient echo sequences were completed both with and without gadolinium contrast. Intra-osseous contributions were quantified within a standardized region of interest (ROI) using customized IDL 6.4 software (Exelis, Boulder, CO). Perfusion of the distal femur was assessed in six different zones. The signal intensity on MRI was then quantified in the distal femur and comparison was made between the experimental plated limb and the contralateral, control limb. Following completion of the MRI protocol, the specimens were injected with latex medium and the extra-osseous vasculature was dissected. Quantitative MRI revealed that application of the lateral distal femoral locking plate reduced the perfusion of the distal femur by 21.7%. Within the dual plating group there was a reduction in perfusion by 24%. There was no significant difference in the perfusion between the isolated lateral plate and the dual plating groups. There were no regional differences in perfusion between the epiphyseal, metaphyseal or meta-diaphyseal regions. Specimen dissection in both plating groups revealed complete destruction of any periosteal vessels that ran underneath either the medial or lateral plates. Multiple small vessels enter the posterior condyles off both superior medial and lateral geniculate arteries and were preserved in all specimens. Furthermore, there was retrograde flow to the distal most aspect of the condyles medially and laterally via the inferior geniculate arteries. The medial vascular pedicle was proximal to the medial plate in all the dual plated specimens and was not disrupted by the medial sub-vastus approach in any specimens. Fixation of the distal femur via a lateral sub-vastus approach and application of a lateral locking plate results in a 21% reduction in perfusion to the distal femur. The addition of a medial 3.5mm reconstruction plate does not significantly compromise the vascularity of the distal femur. The majority of the vascular insult secondary to open reduction, internal fixation of the distal femur occurs with application of the lateral locking plate


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 67 - 67
1 Jun 2018
Gonzalez Della Valle A
Full Access

Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2005 and 2014, 21 patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all-polyethylene cup was used. Pre-operative diagnosis was aseptic loosening (15 cemented and 6 uncemented). The femoral component was revised in 10 patients. Post-operative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete post-operative sciatic palsy. After a mean follow up of 47 months (13 to 128) none of the patients required re-revision of the acetabular component. One asymptomatic patient presented with aseptic loosening 9 years post-operatively. Hardware failure was not observed. All patients had radiographic signs of graft incorporation and bone remodeling. There were no dislocations. The early and mid-term results of revisions of large acetabular defects with this technique are encouraging. Reconstitution of hip center of rotation and bone stock with the use of a small-size implant makes this technique an attractive option for large defects. Longer follow-up is needed to assess survivability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 86 - 86
1 Dec 2016
Philippot R Boyer B Neri T Farizon F
Full Access

The main causes of total hip arthroplasty (THA) revisions are loosening and instability. Use of a dual mobility cup cemented in a acetabular reconstruction cage device limits the risk of instability and does not hinder the acetabular fixation during THA revisions. The objective of this study was to analyse a retrospective series of 123 THA revisions with antiprotusio cage and dual mobility socket. Patients and methods: At a mean follow-up of 10 years, we analysed a continuous series of 123 revisions using a reconstruction device (87 Kerboull cross-plates, 12 Burch-Schneider antiprotrusio cages, 24 custom-fit Novae ARM cages associated in all cases with a Novae Stick dual mobility cup cemented into the cage). There were 80 women and 43 males. The mean age at the surgery was 69.2 years old. PMA score increased from 9.6 +/− 3.06 preoperatively to 14.2 +/− 2. at the follow-up. 9 early dislocations occurred and one late dislocation. At the last follow-up, the X-rays showed nine hardware failures, including one cross-plate fracture, one hook fracture, and one flange fracture. Analysis of the radiological position of the cup showed a mean lowering of 13 mm and a 7 mm lateralisation compared to the preoperative position. 2 revisions for aseptic loosening and 3 for septic loosening were performed. This study confirms the advantage of dual mobility cups during acetabular reconstruction cemented in antiprotrusio cages as a way to limit, without eliminating, the risk of dislocation. Therefore cemented fixation of dual mobility cups in cages appears to be a reliable short-term option


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 62 - 62
1 Dec 2016
Della Valle AG
Full Access

Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3B) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2006 and 2014, sixteen patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all polyethylene cup was used. Preoperative diagnosis was aseptic loosening (10 cemented and 6 non-cemented). The femoral component was revised in 9 patients. Postoperative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete postoperative sciatic palsy. After a mean follow up of 40 months (24 to 104) none of the patients required re-revision. One asymptomatic patient presented with aseptic loosening 9 years postoperatively. Hardware failure was not observed. All patients had radiographic signs of graft incorporation and bone remodeling. There were no dislocations. The early and mid-term results of revisions for large acetabular defects with this technique are encouraging. Reconstitution of hip center of rotation and bone stock with the use of a small-size implant make this technique an attractive option for these large defects. Longer follow-up is needed to assess survivability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 75 - 75
1 May 2016
Tarallo L Mugnai R Catani F
Full Access

Background. Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at mean 24-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon (CFR-PEEK) for the treatment of distal radius fractures. Materials and methods. We performed a prospective study including all patients who were treated for unstable distal radius fracture with a CFR-PEEK volar fixed angle plate. We included 70 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 35 fractures were type C1, 13 were type C2, 6 were type C3, 5 were type B1 and 11 were type B2. Results. All fractures healed, and radiographic union was observed at an average of 6 weeks. The final Disabilities of Arm, Shoulder and Hand score was 5.2 points. The average grip strength, expressed as a percentage of the contralateral limb, was 94 %. Three cases of hardware breakage were reported. Two cases were due to intraoperative plate rupture caused by the attempt to achieve the reduction of the fracture in 1 case and while inserting a distal screw in the other case. In the last case hardware breakage was caused by a fall on the injuried arm 1 week after surgery. No cases of loss of the surgically achieved fracture reduction were documented. Hardware removal was performed in 3 cases, for the occurrence of extensor tenosynovitis in 2 patients and tenosynovitis of flexor pollicis longus in 1 case. Conclusion. The major advantage of CFR-PEEK plate is its radiolucency. This characteristic allows direct visualization of osseous callus formation, allowing monitoring of the healing of the fracture, thereby improving clinical assessment and accuracy. Therefore, specific indications for this new radiolucent plate can be represented by fractures with significant metaphyseal comminution and in cases of nascent malunion where a distal radius osteotomy with bone grafting is usually performed to correct the wrong angle. At early follow-up this device showed good clinical results and allowed maintenance of reduction in complex, AO fractures. The occurrence of tendon complications related to this implant was similar to that reported in literature for the other new-generation plates. However, attention should be payed when stressing the plate to achieve the desired fracture reduction to avoid hardware failure


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 30 - 30
1 Sep 2014
Laubscher M Held M Dunn RN
Full Access

Purpose of the study. To review the primary bone tumours of the spine treated at our unit. Description of methods. Retrospective review of folders and x-rays of all the patients with primary bone tumours of the spine treated at our unit between 2005 and 2012. All haematological tumours were excluded. Summary of results. We treated 15 cases during this period. The median age at presentation was 36 years (8–65). There was a significant delay from onset of symptoms to diagnosis in most cases (median 7 months). Histological diagnoses included:. -Benign tumours.  Active. Hemangioma. 3. Osteoid osteoma. 1. Eosinophilic granuloma. 1.  Aggressive. Osteoblastoma. 1. Giant cell tumours. 2. Aneurysmal bone cysts. 4. -Malignant tumours.  Osteosarcomas. 2.  Leiomyosarcoma of bone. 1. A variety of definitive surgical methods were utilised. Seven patients had a debulking or intralesional resection of the tumour. Eight patients had an attempted marginal excision. This was achieved through anterior surgery only in 1 case, posterior only surgery in 6 cases and combination anterior and posterior surgery in 8 cases. The anterior and posterior surgery was performed in a single sitting in 5 cases and in a staged fashion in 3 cases. Adjuvant radiotherapy and chemotherapy were used where indicated. Three cases presented with significant neurological impairment. Of these 2 made a significant recovery. There were no cases of neurological deterioration following surgery. All 3 patients with malignant tumours died in the follow up period. We had 1 case of hardware failure due to chronic sepsis. Conclusion. Primary bone tumours of the spine are associated with a significant delay in diagnosis. Surgical treatment options and adjuvant therapy should be tailor made for each case depending on the diagnosis. Acceptable results with minimal complications can be achieved with this approach


Bone & Joint Open
Vol. 4, Issue 8 | Pages 643 - 651
24 Aug 2023
Langit MB Tay KS Al-Omar HK Barlow G Bates J Chuo CB Muir R Sharma H

Aims

The standard of wide tumour-like resection for chronic osteomyelitis (COM) has been challenged recently by adequate debridement. This paper reviews the evolution of surgical debridement for long bone COM, and presents the outcome of adequate debridement in a tertiary bone infection unit.

Methods

We analyzed the retrospective record review from 2014 to 2020 of patients with long bone COM. All were managed by multidisciplinary infection team (MDT) protocol. Adequate debridement was employed for all cases, and no case of wide resection was included.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 89 - 89
1 Mar 2012
Gakhar H Prasad K Gill S Dhillon M Gill S Dhillon M Sharma H
Full Access

Management of open tibial fractures remains controversial. We hypothesised that unreamed intramedullary nail offers inherent advantages of nail as well as external fixation. We undertook a prospective randomised study to compare the results of management of open tibial fractures with either an external fixator or an undreamed intramedullary nail until fracture union or failure. Our study included 30 consecutive open tibial fractures (Gustilo I, II & IIIA) between 4 cm distal to knee and 4 cm proximal to ankle in skeletally mature adults, who presented to a level-1 trauma centre. Alternate patients were treated by either external fixation and unreamed nailing i.e. 15 in each group. Standard protocol for debridement and fixation was followed in all cases. All external fixators were removed at 6 weeks. All cases were followed up until fracture union, the main outcome measurement. 26 (87%) were males and 4 (13%) females; age range was 20-60 years (average 33.8). All fractures in both groups united. Time to union averaged 7.9 months for both groups. Incidence of wound problems, infection, hardware failure and delayed union were comparable. However, there was higher incidence of angular deformities and stiffness of knee and ankle in external fixation group, although not statistically significant. We found no statistically significant difference between unreamed intramedullary nailing and external fixation for the management of open tibial diaphyseal fractures, although ease of weight bearing as well as absence of angular deformities and joint stiffness were distinct advantages in the nail group. Therefore we recommend unreamed nail for Gustilo I, II and IIIA open tibial fractures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 19 - 19
1 Mar 2013
Naude P Maqungo S Roche S Nortje M
Full Access

Purpose of study. Unstable pelvic ring injuries usually occur in polytrauma patients and are associated with high mortality and morbidity. Percutaneous screw fixation of sacro-iliac joint dislocations, fracture-dislocations and sacral fractures is a well-recognised technique first described by Routt and is increasingly gaining popularity. This method is biomechanically comparable to open reduction and internal fixation with plates and screws but offers the advantages of minimally invasive surgical techniques. It is however a technically demanding procedure with reported complications including hardware failure, misplacement of screws, nerve injury and poor posterior reduction. The purpose of the study is to report clinical results of patients treated with closed reduction and percutaneous ilio-sacral screw fixation for unstable pelvic ring fractures by a single surgeon. Methods. A review of prospectively collected data was performed on all patients who had percutaneous sacro-iliac fixation between 2009 and 2012. Thirty five percutaneus sacro-iliac screws were inserted in 30 patients with a mean age of 25.6 years (range 17–62). Fracture types included 10 AO type B, and 20 AO type C. The mean follow-up period was 11.6 months (range 3–38). The complications assessed were screw misplacement, neurovascular complications, hardware breakage and loss of reduction. Results. All patients had a satisfactory initial reduction. One patient (2.8%) had misplacement of a screw with resultant temporary neurological fallout. One patient (2.8%) had screw misplacement without neurological fallout. Both of these patients initially had two screws inserted and the misplaced screws were removed and not reinserted. One patient (2.8%) had screw cut-out with loss of reduction. This screw was removed, open reduction peformed and the screw was re-inserted. Conclusion. The use of percutaneous sacro-iliac screws provides a safe and effective technique for the management of unstable posterior pelvic ring injuries. Our combined complication rate is comparable to published literature. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 132 - 132
1 Sep 2012
Vasarhelyi EM Yach J
Full Access

Purpose. Anterior column screw fixation has been a useful tool in the management of acetabular fractures, either alone or in combination with other fixation techniques. Percutaneous insertion may be advantageous by limiting surgical dissection but little has been reported on its safety. The purpose of this study is to report on the efficacy and safety of percutaneous anterior column stabilization. Method. In a consecutive series of 122 operatively treated acetabular fractures, 56 patients were treated with antegrade percutaneous anterior column stabilization either alone or in combination with other fixation techniques by a single surgeon (JY). The technique was selected when the anterior column portion of the fracture was undisplaced or could be reduced via indirect methods. Intraoperative fluoroscopy was used to guide the placement of either a 6.5 mm or 7.3 mm cannulated antegrade anterior column lag screw. Postoperative radiographs (anteroposterior and Judet views) were obtained in the recovery room, prior to discharge and at clinic follow up. Results. The mean age of patients in the series was 52 years (range 17 91). Mean follow up was 13 months. There was one death from associated injuries. Based on the classification system described by Letournel, there were 22 anterior column, 8 transverse, 11 transverse / posterior wall, 9 anterior column / posterior hemitransverse, 1 associated both column and 5 T-type fractures. There were no vascular, neurologic, or urologic complications in the series. There were no cases of intraarticular screw placement. In two cases, the screw did not completely cross the entire fracture line on postoperative radiographs. There were no cases of hardware failure or loss of reduction. There were two cases of hardware removal for hardware prominence. There was one case of chronic proximal femur osteomyelitis, and two cases requiring subsequent total hip arthroplasty for associated injuries. All fractures healed. Conclusion. This study supports percutaneous anterior column stabilization as a safe and effective technique in the treatment of selected acetabular fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 131 - 131
1 Sep 2012
Ashman BD Slobogean GP Stone T
Full Access

Purpose. Open reduction and plate fixation of displaced mid-shaft clavicle fractures has gained significant popularity following a recent multi-center randomized control trial. The purpose of this study is to describe the incidence of reoperation following plate fixation of displaced mid-shaft clavicle fractures. The secondary objective is to determine if plate design influences the incidence of reoperation. Method. A retrospective search of our hospital database was performed to identify subjects treated with plate fixation for a displaced clavicle fracture between 2001 and 2009. Radiographs and medical records were used to identify demographic data, fracture classification, plate design, and reoperation events. Only mid-shaft (AO/OTA 15-B) fractures treated with either a Low-Contact Dynamic Compression (LCDC) plate or Pre-contoured Locking (PCL) plate were included. Results. 144 subjects were included in the study. The mean age was 36 years (95% CI 33 38 years) and the mean duration of follow-up was 60 weeks (95% CI 46 74 weeks). 60% of included fractures were wedge pattern (15-B2), followed by 35% simple (15-B1) fractures, and 5% complex (15-B3) fracture patterns. Pre-contoured locking plates were used in 92 cases (64%) and LCDC plates were used in the remaining 52 subjects (36%). 21 subjects (15%) underwent reoperation: 17% of subjects treated with LCDC plates and 13% of subjects treated with PCL plates (p=0.62). Indications for reoperation included painful hardware (86%), hardware failure (9%), and refracture (5%). There was no association between reoperation and age (p = 0.23), gender (p = 0.56), fracture type (p = 0.53), or plate design (p = 0.49). Conclusion. This study represents a large series of displaced clavicle fractures treated with open reduction and plate fixation. Reoperation following plate fixation is relatively common and is primarily due to painful hardware. No difference in reoperation rates between LCDC and pre-contoured plates could be detected in the current sample size


Bone & Joint Research
Vol. 10, Issue 7 | Pages 425 - 436
16 Jul 2021
Frommer A Roedl R Gosheger G Hasselmann J Fuest C Toporowski G Laufer A Tretow H Schulze M Vogt B

Aims

This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported.

Methods

This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed.