Advertisement for orthosearch.org.uk
Results 1 - 20 of 227
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 75 - 75
1 Dec 2019
Boot W Foster A Schmid T D'este M Zeiter S Eglin D Richards G Moriarty F
Full Access

Aim. Implant-associated osteomyelitis is a devastating complication with poor outcomes following treatment, especially when caused by antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA). A large animal model of a two-stage revision to treat MRSA implant-associated osteomyelitis has been developed to assess novel treatments. A bioresorbable, thermo-responsive hyaluronan hydrogel (THH) loaded with antibiotics has been developed and our aim was to investigate it´s in vivo efficacy as a local antibiotic carrier compared to the current standard of care i.e. antibiotic-loaded polymethylmethacrylate (PMMA) bone cement. Method. 12 female, 2 to 4 year old, Swiss Alpine Sheep were inoculated with MRSA at the time of intramedullary nail insertion in the tibia to develop chronic osteomyelitis. After 8 weeks sheep received a 2-stage revision protocol, with local and systemic antibiotics. Group 1 received the gold standard clinical treatment: systemic vancomycin (2 weeks) followed by rifampicin plus trimethoprim/sulfamethoxazole (4 weeks), and local gentamicin/vancomycin via PMMA. Group 2 received local gentamicin/vancomycin delivered via THH at both revision surgeries and identical systemic therapy to group 1. Sheep were euthanized 2 weeks following completion of antibiotic therapy. At euthanasia, soft tissue, bone, and sonicate fluid from the hardware was collected for quantitative bacteriology. Results. Sheep tolerated the surgeries and both local and systemic antibiotics well. Gold standard of care successfully treated 3/6 sheep with a total of 10/30 culture-positive samples. All 6 sheep receiving antibiotic-loaded THH were successfully treated with 0/30 culture-positive samples, p=0.0008 gold-standard vs. hydrogel (Fisher's Exact). Conclusions. The clinical gold standard treatment was successful in 50% of sheep, consistent with outcomes reported in the literature treating MRSA infection. The antibiotic-loaded THH clearly outperformed the gold standard in this model. Superior efficacy of the THH is likely due to 1) the ability to administer local antibiotics at the both revision surgies due to the bioresorbable nature of the hydrogel, and 2) complete antibiotic release compared to bone cement, which is known to retain antibiotics. Our results highlight the potential of local delivered, biodegradable systems for antibiotics for eradicating implant-related infection caused by antibiotic-resistant pathogens. Acknowledgement. Funding provided by AO Trauma


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 80 - 80
1 Nov 2016
Saithna A Longo A Leiter J MacDonald P Old J
Full Access

The majority of studies reporting sensitivity and specificity data for imaging modalities and physical examination tests for long head of biceps (LHB) tendon pathology use arthroscopy as the gold standard. However, there is little published data to validate this as an appropriate benchmark. The aim of this study was to determine the maximum length of the LHB tendon that can be seen at glenohumeral arthroscopy and whether it allows adequate visualisation of common sites of pathology. Seven female cadaveric specimens were studied. Mean age was 74 years (range 44–96 years). Each specimen underwent arthroscopy in lateral decubitus (LD) and beach chair (BC) positions. The LBH-tendon was tagged with a suture placed with a spinal needle marking the intra-articular length and the maximum excursions achieved using a hook and a grasper in both LD and BC positions. T-tests were used to compare data. The mean intra-articular and extra-articular lengths of the tendon were 23.9 mm and 82.3 mm respectively. The mean length of tendon that could be visualised by pulling it into the joint with a hook was significantly less than with a grasper (LD: hook 29.9 mm, grasper 33.9 mm, mean difference 4 mm, p=0.0032. BC: hook 32.7 mm, grasper 37.6 mm, mean difference 4.9 mm, p=0.0001). Using the BC position allowed visualisation of a significantly greater length than the LD position when using either a hook (mean difference 2.86 mm, p=0.0327) or a grasper (mean difference 3.7 mm, p=0.0077). The mean length of the extra-articular part of the tendon visualised using a hook was 6 mm in LD and 8.9 mm in BC. The maximum length of the extra-articular portion visualised using this technique was 14 mm (17%). Pulling the tendon into the joint with a hook does not allow adequate visualisation of common distal sites of pathology in either LD or BC. Although the BC position allows a significantly greater proportion of the tendon to be visualised this represents a numerically small value and is not likely to be clinically significant. The use of a grasper also allowed greater excursion but results in iatrogenic tendon injury which precludes its use. The reported incidence of pathology in Denard zone C (distal to subscapularis) is 80% and in our study it was not possible to evaluate this zone even by using a grasper or maximum manual force to increase excursion. This is consistent with the extremely high rate of missed diagnoses reported in the literature. Surgeons should be aware that the technique of pulling the LHB-tendon into the joint is inadequate for visualising distal pathology and results in a high rate of missed diagnoses. Furthermore, efforts to achieve greater excursion by “optimum” limb positioning intra-operatively do not confer an important clinical advantage and are probably unnecessary


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 4 - 4
1 Apr 2013
Kassam A Griffiths S Higgins G
Full Access

Recent NICE guidelines have suggested abandoning the Thompson hemiarthroplasty (TH) in favour of a ‘proven prosthesis’ such as the Exeter Trauma Stem (ETS). This is controversial because of significant cost implications and limited research assessing outcomes of the ETS. The aim of this study was to assess the treatment of intracapsular neck of femur fractures with the TH. Between 2002 and 2006 (minimum 5 year follow-up), 431 cemented TH's were performed. Death rate at 1 year and 5 years were 26.0% and 67.7% respectively. Dislocation (1.4%) and infection (0.2%) rates were low and revision rate was 1.2%. Comparison was made to Bipolar hemiarthroplasties over the same period (total 194). These had lower rates of dislocation (0.5%) and infection (0.5%) with a significantly higher (3.6%) revision rate. We feel that the TH remains the current gold standard treatment for intracapsular fractures, in appropriate patients, due to low complication and revision rates. Modern implants may provide better function or longevity, but there is no evidence in the literature to support abandoning the TH. Surgeons should assess patients and decide on its use, despite NICE guidelines, as it remains a cost effective treatment method, particularly for older, less mobile and cognitively impaired patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 86 - 86
1 Dec 2016
Thienpont E
Full Access

A majority of patients present with varus alignment and predominantly medial compartment disease. The secret of success in osteoarthritis (OA) treatment is patient selection and patient specific treatment. Different wear patterns have been described and that knowledge should be utilised in modern knee surgery. In case of isolated anteromedial OA, unicompartmental knee arthroplasty (UKA) should be one of the therapeutic options available to the knee surgeon.

The discussion not to offer a UKA to patients is based on the fear of the surgeon not being able to identify the right patient and not being able to perform the surgery accurately. The common modes of failure for UKA, which are dislocation or overcorrection leading to disease progression, can be avoided with a fixed bearing implant. Wear can probably be avoided with newer polyethylenes and avoidance of overstuffing in flexion of the knee. Revision for unexplained pain and unknown causes should disappear once surgeons understand persistent pain after surgery much better than they do today.

The choice in favor of UKA is a choice of function over survivorship, a choice for reduced comorbidity and lower mortality. Many of the common problems in TKA are not an issue in UKA. Component overhang, decreased posterior offset, changed joint line height, gap mismatch, flexion gap instability, lift off and paradoxical motion hardly exist in UKA if the replacement is performed according to resurfacing principles with respect for the native knee anatomy.

New technologies like navigation, PSI and robotics will help with alignment and component positioning. Surgeon education and training should allow over time UKA to be performed by all of us.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 87 - 87
1 Dec 2016
Ranawat C
Full Access

There exists a variety of options for a medial compartment knee with osteoarthritis, specifically a unicompartmental knee, high tibial osteotomy, and total knee arthroplasty. This surgeon prefers a rotating platform posterior stabilised total knee to the unicompartmental knee. Unicompartmental knee arthroplasty (UKA) in younger patients is being performed with increasing frequency. While UKA is a powerful marketing tool because of its minimally invasive nature and quality of knee function that is superior to the total knee arthroplasty (TKA), it has tremendous drawbacks. These include: the selection criteria is very specific and the number of patients that fit in that category is small, there is a steep learning curve for the surgeon to perfect the technique, higher failure due to wear and loss of fixation, and unexplained pain. Based on level 1 and 2 evidence available it is not justified to do more UKAs at present when the results of a TKA are so successful.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 3 - 3
1 Oct 2017
Blocker O Cool P Lewthwaite S
Full Access

Frozen section is a recognised technique to assist in the diagnosis of infection and there are standards for reporting. Our aim of this review was to assess the value of frozen section in the diagnosis of infection, as well as other variables.

We performed a retrospective review of all frozen sections for suspected infection in 2016. Patient demographics, histological and microbiological investigations, laboratory and bedside tests were recorded and analysed using statistical software.

46 patients had 55 frozen sections; the majority were for lower limb arthroplasty. No sections were reported as polymorphonuclear neutrophils per high-power field. Three sections showed signs of infection and one without evidence had positive cultures. One uncertain section did not grow organisms. 10 patients had two-stage procedures, four of these were intended to be determined by frozen section but only two had evidence of infection on analysis.

Evidence of infection on frozen section does correlate with microbiological growth but does not relate to intention to stage procedures in half of patients. The effect of new tests such as Synovasure is highlighted by this review.

Frozen section analysis is reported subjectively but is a good predictor of infection. Clinical assessment is accurate in diagnosing infection. Histological, microbiological and additional investigations should be considered in relation to their cost-effectiveness.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1455 - 1456
1 Nov 2012
Oussedik S Gould K Stockley I Haddad FS

Peri-prosthetic infection remains a leading cause of revision surgery. Recent publications from the American Musculoskeletal Infection Society have sought to establish a definition of peri-prosthetic infection based on clinical findings and laboratory investigations. The limitations of their approach are discussed and an alternative definition is proposed, which it is felt may better reflect the uncertainties encountered in clinical practice.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 30 - 30
1 Mar 2021
Gerges M Eng H Chhina H Cooper A
Full Access

Bone age is a radiographical assessment used in pediatric medicine due to its relative objectivity in determining biological maturity compared to chronological age and size.1 Currently, Greulich and Pyle (GP) is one of the most common methods used to determine bone age from hand radiographs.2–4 In recent years, new methods were developed to increase the efficiency in bone age analysis like the shorthand bone age (SBA) and the automated artificial intelligence algorithms. The purpose of this study is to evaluate the accuracy and reliability of these two methods and examine if the reduction in analysis time compromises their accuracy. Two hundred thirteen males and 213 females were selected. Each participant had their bone age determined by two separate raters using the GP (M1) and SBA methods (M2). Three weeks later, the two raters repeated the analysis of the radiographs. The raters timed themselves using an online stopwatch while analyzing the radiograph on a computer screen. De-identified radiographs were securely uploaded to an automated algorithm developed by a group of radiologists in Toronto. The gold standard was determined to be the radiology report attached to each radiograph, written by experienced radiologists using GP (M1). For intra-rater variability, intraclass correlation analysis between trial 1 (T1) and trial 2 (T2) for each rater and method was performed. For inter-rater variability, intraclass correlation was performed between rater 1 (R1) and rater 2 (R2) for each method and trial. Intraclass correlation between each method and the gold standard fell within the 0.8–0.9 range, highlighting significant agreement. Most of the comparisons showed a statistically significant difference between the two new methods and the gold standard; however it may not be clinically significant as it ranges between 0.25–0.5 years. A bone age is considered clinically abnormal if it falls outside 2 standard deviations of the chronological age; standard deviations are calculated and provided in GP atlas.6–8 For a 10-year old female, 2 standard deviations constitute 21.6 months which far outweighs the difference reported here between SBA, automated algorithm and the gold standard. The median time for completion using the GP method was 21.83 seconds for rater 1 and 9.30 seconds for rater 2. In comparison, SBA required a median time of 7 seconds for rater 1 and 5 seconds for rater 2. The automated method had no time restraint as bone age was determined immediately upon radiograph upload. The correlation between the two trials in each method and rater (i.e. R1M1T1 vs R1M1T2) was excellent (κ= 0.9–1) confirming the reliability of the two new methods. Similarly, the correlation between the two raters in each method and trial (i.e. R1M1T1 vs R2M1T1) fell within the 0.9–1 range. This indicates a limited variability between raters who may use these two methods. The shorthand bone age method and an artificial intelligence automated algorithm produced values that are in agreement with the gold standard Greulich and Pyle, while reducing analysis time and maintaining a high inter-rater and intra-rater reliability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 99 - 99
23 Feb 2023
Woodfield T Shum J Linkhorn W Gadomski B Puttlitz C McGilvray K Seim H Nelson B Easley J Hooper G
Full Access

Polyetheretherketone (PEEK) interbody fusion cages combined with autologous bone graft is the current clinical gold standard treatment for spinal fusion, however, bone graft harvest increases surgical time, risk of infection and chronic pain. We describe novel low-stiffness 3D Printed titanium interbody cages without autologous bone graft and assessed their biological performance in a pre-clinical in vivo interbody fusion model in comparison to the gold standard, PEEK with graft. Titanium interbody spacers were 3D Printed with a microporous (Ti1: <1000μm) and macroporous (Ti2: >1000μm) design. Both Ti1 and Ti2 had an identical elastic modulus (stiffness), and were similar to the elastic modulus of PEEK. Interbody fusion was performed on L2-L3 and L4-L5 vertebral levels in 24 skeletally mature sheep using Ti1 or Ti2 spacers, or a PEEK spacer filled with iliac crest autograft, and assessed at 8 and 16 weeks. We quantitatively assessed bone fusion, bone area, mineral apposition rate and bone formation rate. Functional spinal units were biomechanically tested to analyse range of motion, neutral zone, and stiffness. Results: Bone formation in macroporous Ti2 was significantly greater than microporous Ti1 treatments (p=.006). Fusion scores for Ti2 and PEEK demonstrated greater rates of bone formation from 8 to 16 weeks, with bridging rates of 100% for Ti2 at 16 weeks compared to just 88% for PEEK and 50% for Ti1. Biomechanical outcomes significantly improved at 16 versus 8 weeks, with no significant differences between Ti and PEEK with graft. This study demonstrated that macroporous 3D Printed Ti spacers are able to achieve fixation and arthrodesis with complete bone fusion by 16 weeks without the need for bone graft. These significant data indicate that low-modulus 3D Printed titanium interbody cages have similar performance to autograft-filled PEEK, and could be reliably used in spinal fusion avoiding the complications of bone graft harvesting


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 70 - 70
23 Feb 2023
Gupta S Smith G Wakelin E Van Der Veen T Plaskos C Pierrepont J
Full Access

Evaluation of patient specific spinopelvic mobility requires the detection of bony landmarks in lateral functional radiographs. Current manual landmarking methods are inefficient, and subjective. This study proposes a deep learning model to automate landmark detection and derivation of spinopelvic measurements (SPM). A deep learning model was developed using an international multicenter imaging database of 26,109 landmarked preoperative, and postoperative, lateral functional radiographs (HREC: Bellberry: 2020-08-764-A-2). Three functional positions were analysed: 1) standing, 2) contralateral step-up and 3) flexed seated. Landmarks were manually captured and independently verified by qualified engineers during pre-operative planning with additional assistance of 3D computed tomography derived landmarks. Pelvic tilt (PT), sacral slope (SS), and lumbar lordotic angle (LLA) were derived from the predicted landmark coordinates. Interobserver variability was explored in a pilot study, consisting of 9 qualified engineers, annotating three functional images, while blinded to additional 3D information. The dataset was subdivided into 70:20:10 for training, validation, and testing. The model produced a mean absolute error (MAE), for PT, SS, and LLA of 1.7°±3.1°, 3.4°±3.8°, 4.9°±4.5°, respectively. PT MAE values were dependent on functional position: standing 1.2°±1.3°, step 1.7°±4.0°, and seated 2.4°±3.3°, p< 0.001. The mean model prediction time was 0.7 seconds per image. The interobserver 95% confidence interval (CI) for engineer measured PT, SS and LLA (1.9°, 1.9°, 3.1°, respectively) was comparable to the MAE values generated by the model. The model MAE reported comparable performance to the gold standard when blinded to additional 3D information. LLA prediction produced the lowest SPM accuracy potentially due to error propagation from the SS and L1 landmarks. Reduced PT accuracy in step and seated functional positions may be attributed to an increased occlusion of the pubic-symphysis landmark. Our model shows excellent performance when compared against the current gold standard manual annotation process


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 43 - 43
22 Nov 2024
Bekkers W Zwart V Swietoslawki A Oost IK Nijs A Emmen J Van Geenen R
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the main reasons for revision surgery after primary unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or total hip arthroplasty (THA). Currently the MSIS and EBJIS criteria sets are considered to be the gold standards in determining PJI. These criteria sets are complex and contain tests that are time-consuming and many are rather costly. Therefore, further research is indicated to find a simpler but equally reliable diagnostic test. In this study we evaluated the additional value of calprotectine measurement in synovial fluid in patients undergoing hip and knee (revision) arthroplasty following routine work-up. Method. In a retrospective cohort study, we analyzed 182 synovial fluid samples from 143 patients with suspected PJI after UKA, TKA, THA or revision arthroplasty. Twenty-six of those cases were classified as PJI according to the MSIS and EBJIS criteria. Subsequently, synovial calprotectin was determined, using a lateral flow assay and two cut-off thresholds of ≥14 mg/L and ≥50 mg/L. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of synovial calprotectin was determined. Results. When applying the MSIS and EBJIS criteria and a calprotectin level ≥14 mg/L, synovial calprotectin revealed an area under the curve of 0.96 (95% CI 0.90-1.00), with 92.3% sensitivity and 100% specificity. The PPV and NPV were 100% and 92.9% respectively. When applying the MSIS and EBJIS criteria and a calprotectin level ≥ 50 mg/L, synovial calprotectin revealed an area under the curve of 0.94 (95% CI 0.87-1.00), with 88.5% sensitivity and 100% specificity. The PPV and NPV were 100% and 89.7% respectively. Conclusions. The value of calprotectin in synovial fluid gives valuable information with a single test result, resulting in high predictive value in the diagnosis of PJI after hip or knee arthroplasty and should seriously be considered as part of PJI diagnostics in an outpatient clinical setting. The high specificity can help rule in patients that are suspected of PJI. Therefor this test can be helpful in a preop diagnostic work-up to avoid unnecessary revisions in patients with well-placed and well-fixed arthroplasties with a suspected PJI. These conclusions are independent of which criteria set was used as a gold standard


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 11 - 11
1 Feb 2021
Bartolo M Accardi M Dini D Amis A
Full Access

Objectives. Articular cartilage damage is a primary outcome of pre-clinical and clinical studies evaluating meniscal and cartilage repair or replacement techniques. Recent studies have quantitatively characterized India Ink stained cartilage damage through light reflectance and the application of local or global thresholds. We develop a method for the quantitative characterisation of inked cartilage damage with improved generalisation capability, and compare its performance to the threshold-based baseline approach against gold standard labels. Methods. The Trainable WEKA Segmentation (TWS) tool (Arganda-Carreras et al., 2017) available in Fiji (Rueden et al., 2017) was used to train two separate Random Forest classifiers to automatically segment cartilage damage on ink stained cadaveric ovine stifle joints. Gold standard labels were manually annotated for the training, validation and test datasets for each of the femoral and tibial classifiers. Each dataset included a sample of medial and lateral femoral condyles and tibial plateaus from various stifle joints, selected to ensure no overlap across datasets according to ovine identifier. Training was performed on the training data with the TWS tool using edge, texture and noise reduction filters selected for their suitability and performance. The two trained classifiers were then applied to the validation data to output damage probability maps, on which a threshold value was calibrated. Model predictions on the unseen test set were evaluated against the gold standard labels using the Dice Similarity Coefficient (DSC) – an overlap-based metric, and compared with results for the baseline global threshold approach applied in Fiji as shown in Figures 1 and 2. Results. Test set results for the global threshold approach against gold standard labels were 45.0% DSC for the femoral condyle and 32.0% DSC for the tibial plateau. Results for the developed TWS classifiers on the same unseen test data were 79.0% and 72.7% DSC, showing absolute gains of 34.0% and 40.7% DSC over the global threshold baseline for the femoral and tibial classifiers. The trained TWS classifiers were then applied to an external set of unlabelled images of ink stained femoral condyles and tibial plateaus. Model results on sample images shown in Figure 3 further highlight the generalisation capability of the developed models. The most prominent classification features were Hessian filters (32.9%), Entropy (19.4%), Gaussian blur (10.1%), Gabor filters (6.3%) and Sobel filters (6.0%), with all other features contributing less than 6%. Conclusions. Our findings show that the developed segmentation method more accurately quantifies cartilage damage and provides improved generalisation capability over a range of input variations such as inconsistent orientation and lighting conditions. The developed model enables the use of articular cartilage damage as a reliable and quantitative outcome measure in studies involving large datasets, with reduced requirements for complex pre-processing and specialised equipment. For any figures or tables, please contact the authors directly


Full Access

Abstract. Background. The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R). Graft failure is the concern and ensuring a durable initial graft with rapid integration is crucial. Graft augmentation with implantable devices (internal brace reinforcement) is a technique purported to reduce the risk of rupture and hasten recovery. We aim to compare the short-term outcome of ACL-R using augmented hamstring tendon autografts (internally braced with neoligament) and non-augmented hamstring autografts. Methods. This was a retrospective cohort study comparing augmented and non-augmented ACL-R. All procedures were performed in a single centre using the same technique. The Knee injury and Osteoarthritis Outcome Score [KOOS] was used to assess patient-reported outcomes. Results. There were 70 patients in the augmented and 111 patients in the control group. Mean graft diameter in the augmented group was 8.82mm versus 8.44mm in the non-augmented. Six strand graft was achievable in 73.5% of the augmented group compared to 33% in the non-augmented group. Two graft failures were reported in the non-augmented group and none in the augmented group. Patient satisfaction rates were higher in the augmented group. There was a statistically insignificant improvement in the postoperative KOOS in the augmented group compared to the non-augmented group (p 0.6). Irrespective of augmentation status, no correlation was found between the functional score and age, or femoral tunnel width. Conclusion. Augmented ACL-R may achieve superior graft diameters, lower failure rates and better patient reported outcomes when compared to nonaugmented ACL-R. Prospective trials are needed to examine this further


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 34 - 34
7 Nov 2023
Nicolaou C Sekeitto AR Milner B Urrea JD
Full Access

Fracture related infection, in particular chronic osteomyelitis, requires complex management plans. Meta analyses and systematic reviews have not found a gold standard of treatment for this disease. In 2017 an alternative treatment protocol was undertaken in our institution; whereby staged surgery with the use of cheaply manufactured tailored antibiotic cement rods was used in the treatment of chronic osteomyelitis, secondary to traumatic long bone fractures. Short term outcomes for this protocol demonstrated a 75.7% microbiological resolution to a negative culture and a good clinical outcome of 84.2% overall was demonstrated in terms of sinus resolution, skin changes, pain and function. Our aim now was to assess the long term outcomes of this treatment strategy. A cross-sectional study of patients who had previously undergone the set treatment protocol was performed. Patient satisfaction, effects on activities of daily living, return to work and clinical improvement at 5 years following the intervention were assessed using a patient questionnaire and the validated AAOS lower limb score. The average AAOS lower limb score was 88 which was en par to other similar studies. 80% of patients had returned to some form of work. Ongoing mild pain was a persistent problem for 50% of the patients however 98% of the patients were overall satisfied with the treatment satisfaction at 5 years. Only 1 patient required further treatment. 8 patients could not be located for follow up. Chronic osteomyelitis remains a complex disease to treat. This treatment protocol demonstrates favourable microbiological, serological and clinical short term outcomes and favourable patient satisfaction and functional long term outcomes at 5 years. Our study highlights antibiotic targeted cement rods as a feasible treatment option in managing chronic osteomyelitis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 39 - 39
10 Feb 2023
Lutter C Grupp T Mittelmeier W Selig M Grover P Dreischarf M Rose G Bien T
Full Access

Polyethylene wear represents a significant risk factor for the long-term success of knee arthroplasty [1]. This work aimed to develop and in vivo validate an automated algorithm for accurate and precise AI based wear measurement in knee arthroplasty using clinical AP radiographs for scientifically meaningful multi-centre studies. Twenty postoperative radiographs (knee joint AP in standing position) after knee arthroplasty were analysed using the novel algorithm. A convolutional neural network-based segmentation is used to localize the implant components on the X-Ray, and a 2D-3D registration of the CAD implant models precisely calculates the three-dimensional position and orientation of the implants in the joint at the time of acquisition. From this, the minimal distance between the involved implant components is determined, and its postoperative change over time enables the determination of wear in the radiographs. The measured minimum inlay height of 335 unloaded inlays excluding the weight-induced deformation, served as ground truth for validation and was compared to the algorithmically calculated component distances from 20 radiographs. With an average weight of 94 kg in the studied TKA patient cohort, it was determined that an average inlay height of 6.160 mm is expected in the patient. Based on the radiographs, the algorithm calculated a minimum component distance of 6.158 mm (SD = 81 µm), which deviated by 2 µm in comparison to the expected inlay height. An automated method was presented that allows accurate and precise determination of the inlay height and subsequently the wear in knee arthroplasty based on a clinical radiograph and the CAD models. Precision and accuracy are comparable to the current gold standard RSA [2], but without relying on special radiographic setups. The developed method can therefore be used to objectively investigate novel implant materials with meaningful clinical cohorts, thus improving the quality of patient care


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 14 - 14
1 Mar 2021
Au K Gammon B Undurraga S Culliton K Louati H D'Sa H
Full Access

The clinical diagnosis of distal radioulnar joint (DRUJ) instability remains challenging. The current diagnostic gold standard is a dynamic computerized topography (CT) scan. This investigation compares the affected and normal wrists in multiple static positions of forearm rotation.. However, its accuracy has been questioned, as the wrist is unloaded and not placed under stress. This may fail to capture DRUJ instability that does not result in static malalignment between the ulnar head and sigmoid notch. The purpose of this biomechanical study was to evaluate the effectiveness of both dynamic and stress CT scans in detecting DRUJ instability. A customized DRUJ arthrometer was designed that allows for both static positioning, as well as dorsal and volar loading at the DRUJ in various degrees of forearm rotation. Ten fresh frozen cadavers were prepared and mounted in the apparatus. CT scans were performed both in the unloaded condition (dynamic CT) and with each arm subjected to a standardized 50N volar and dorsal force (stress CT) in neutral and maximum pronation/ supination. The TFCC (triangular fibrocartilage complex)was then sectioned peripherally to simulate DRUJ instability and the methodology was repeated. CT scans were then evaluated for displacement using the radioulnar ratio method. When calculating the radioulnar ratio for intact wrists using the dynamic CT technique, values were 0.50, 0.64, 0.34 for neutral, pronation and supination, respectively. When the TFCC was sectioned and protocol repeated, the values for the simulated unstable wrist for dynamic CT were 0.54, 0.62, 0.34 for neutral, pronation and supination, respectively. There was no statistically significant difference between the intact and sectioned states for any position of forearm rotation using dynamic CT. Usingstress CT, mean radioulnar ratios for the intact specimens were calculated to be 0.44, 0.36 and 0.31 for neutral, pronation and supination, respectively. After sectioning the TFCC, the radioulnar ratios increased to 0.61, 0.39 and 0.46 for neutral, pronation and supination. There was a statistically significant difference between intact and simulated-unstable wrists in supination (p = 0.002) and in neutral (p=0.003). The radioulnar ratio values used to measure DRUJ translation for dynamic CT scans were unable to detect a statistically significant difference between stable and simulated unstable wrists. This was true for all positions of forearm rotation. However, when a standard load was placed across the DRUJ, statically significant changes in the radioulnar ratio were seen in neutral and supination between stable and simulated unstable wrists. This discrepancy challenges the current gold standard of dynamic CT in its ability to accurately diagnosis DRUJ instability. It also introduces stress CT as a possible solution for diagnosing DRUJ instability from peripheral TFCC lesions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 36 - 36
7 Nov 2023
Waters R Held M Dunn R Laubscher M Adikary N Coussens A
Full Access

Specific and rapid detection methods for spinal tuberculosis, with sufficient sensitivity in HIV-1 co-infected individuals, are needed, to ensure early initiation of appropriate treatment to prevent physical disability and neurological fallout. In addition, understanding the systemic and local pathophysiology of spinal tuberculosis, and its interaction with HIV-1 infection, is crucial to guide future therapeutic interventions. We prospectively enrolled adult patients presenting with signs and symptoms of suspected spinal tuberculosis, at Groote Schuur Hospital, between November 2020 and December 2021. TB diagnostic testing was performed on open and CT-guided spinal biopsies using Xpert MTB/RIF Ultra compared to gold standards TB culture and histology. A highly sensitive droplet digital PCR assay for detecting and quantifying Mycobacterium tuberculosis complex (MTBC) and HIV-1 DNA was tested. Plasma inflammatory proteins were measured to assess systemic inflammation. Xpert Ultra had a high sensitivity of 94.7% and specificity of 100% for STB against TB culture and histology in both open and CT-guided biopsy samples. The ddPCR assay confirmed TB detection in 94% of patients with positive Xpert Ultra results. Four patients with negative TB diagnostic results had MTBC DNA detected by ddPCR. HIV-1 DNA was detected in the spinal tissues from all HIV-1-infected patients. MTBC DNA levels were significantly higher in HIV-1-co-infected spinal tissue samples (p< 0.01). We identified four biomarkers significantly associated with higher bacterial burden at the disease site (p< 0.01). Xpert Ultra and MTBC ddPCR improve the detection of STB. DdPCR can be utilized as an additional, highly sensitive tool for detecting and quantifying Mtb, in pathological samples that may be paucibacillary. These findings provide novel diagnostic and pathophysiologic insight into STB, in the context of HIV-1 infection, and provide rationale to include these tests in hospital and research settings for patients from communities burdened by TB and HIV-1


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 91 - 91
7 Nov 2023
Abramson M McCollum G
Full Access

Ankle sprains are common injuries. Most of them involve the lateral ligament complex. 20–40%% of these injuries will go onto develop symptomatic chronic lateral instability (CLI) and require surgical intervention. The gold standard surgical treatment remains the Brostom-Gould. There are however certain scenarios where this may be unsuitable, such as in hyperlaxity, poor native tissue or revision surgeries. In these situations, a reconstruction with some form of augmentation or grafting is necessary. The anterior half of peroneus longus (AHPL) has gained in popularity as an autograft due to its favourable tendon properties, ease of harvesting, and low reported morbidity. This technique has been adopted by the senior author in these situations. Our primary aim was to assess patient reported outcomes and satisfaction following this surgery. Our secondary objectives were to assess return to sports, donor site morbidity and to report any surgical complications. We performed a retrospective single surgeon study on all patients who underwent CLI reconstruction using the anterior half of peroneus longus between 2014 and 2021. Data was collected prospectively. The Karlsson foot and ankle scoring chart as well as a simple satisfaction table were used to assess outcomes. Minimum follow up was 1 year. 44 patients met the inclusion criteria. 23 women, 21 men. The average age was 37.0 (+−13.5). 24 were very satisfied with the surgery, 10 were satisfied, 6 were fair and 4 were dissatisfied. The average Karlsson score improved from 65/90 (34–77) to 85/90 (range 45–90). The average return to sport was 5 months. There was 1 non-surgical complication recorded. There was no repeat surgery for a complication, or recurrent instability and no donor-site morbidity was reported. The results of our study demonstrates that the CLIR using AHPL is a reliable, predictable and safe


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 80 - 80
1 Oct 2022
Morovic P Karbysheva S Meller S Kirschbaum S Perka C Conen A Trampuz A
Full Access

Aim. Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA. Method. Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity. Results. A total of 155 patients were included. Using institutional criteria, 21 patients (14%) were diagnosed with SA and 134 (86%) patients with aseptic arthropathy, out of which 43 (27%) had osteoarthrosis, 80 (52%) had rheumatic arthropathy and 11 (7%) reactive arthritis. The optimal cut-off of synovial fluid D-lactate to differentiate SA from aseptic cases was 0,035 mmol/l. Synovial fluid D-lactate had a sensitivity 90% (95% CI: 70–99%) and specificity 87% (95% CI: 80–92%) compared to leukocyte count with sensitivity 81% (95% CI: 60–95%) and specificity 83% (95% CI: 76–90%). Culture was positive in only 17 (80%) out of 21 patients with SA. Conclusions. The synovial fluid D-lactate showed high sensitivity and specificity for diagnosis of SA which was higher than the current gold standard of diagnosis (culture and leukocyte count). The high sensitivity makes this biomarker useful as a point-of-care screening test for SA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 49 - 49
23 Feb 2023
Sorial R Coffey S Callary S
Full Access

Roentgen Stereophotogrammetric Analysis (RSA) is the gold standard for measuring implant micromotion thereby predicting implant loosening. Early migration has been associated with the risk of long-term clinical failure. We used RSA to assess the stability of the Australian designed cementless hip stem (Paragon TM) and now report our 5-year results. Fifty-three patients were prospectively and consecutively enrolled to receive a Paragon hip replacement. Tantalum beads were inserted into the bone as per RSA protocol and in the implant. RSA x-rays were taken at baseline 1–4 days post-surgery, at 6 weeks, 6 months, 12 months, 2 years, and 5 years. RSA was completed by an experienced, independent assessor. We reported the 2-year results on 46 hips (ANZJS 91 (3) March 2021 p398) and now present the 5-year results on 27 hips. From the 2-year cohort 5 patients had died, 8 patients were uncontactable, 1 patient was too unwell to attend, 5 patients had relocated too far away and declined. At 5 years the mean axial subsidence of the stem was 0.66mm (0.05 to 2.96); the mean rotation into retroversion was 0.49˚ (−0.78˚ to 2.09˚), rotation of the stem into valgus was −0.23˚ (−0.627˚ to 1.56˚). There was no detectable increase in subsidence or rotation between 6 weeks and 5 years. We compared our data to that published for the Corail cementless stem and a similar pattern of migration was noted, however greater rotational stability was achieved with the Paragon stem over a comparable follow-up period. The RSA results confirm that any minor motion of the Paragon cementless stem occurs in the first 6 weeks after which there is sustained stability for the next 5 years. The combination of a bi-planar wedge and transverse rectangular geometry provide excellent implant stability that is comparable to or better than other leading cementless stems