Advertisement for orthosearch.org.uk
Results 1 - 20 of 28
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 6 - 6
1 Feb 2020
Crighton E Jenkins P Butterworth G Elias-Jones C Brooksbank A
Full Access

Combined glenoid and humeral bone loss has been identified as an important factor in predicting recurrence after arthroscopic shoulder stabilisation. The “glenoid track” concept is proposed to predict recurrent instability by comparing the relative size of the glenoid to the humeral bone defect. The aim of this study was to investigate whether assessment of the glenoid track on a pre-operative MR arthrogram could be used to predict subsequent instability in a typical UK population. A retrospective study was undertaken of 175 primary arthroscopic stabilisation procedures of which 82% (n=143) were men. The median age was 26 years (IQR 22 to 32, range 16 to 77). The median follow-up was 76 months (range 21 to 125). A pre-operative MR arthrogram was used to determine if the shoulder was on-track or off-track. The endpoint of recurrent dislocation was examined. The prevalence of “off-track” bone loss in this group was 14.2% (n=25). There were 6 (24%) dislocations in the off-track group compared with 5 (3.33%) dislocations in the on-track group (RR 7.2, 95% CI 2.45 to 20.5, p=0.001). At 5 years, the cumulative redislocation rate was 26.1% in the off-track group compared with 8.7% in on-track group. The rate of any recurrent instability was 60% (n=15) v 18% (n=27) (RR 3.33, 95% CI 2.02 to 5.20, p<0.0001). Glenoid track (on v off) was not predicted by gender (p=0.411). In a typical UK population assessment of the glenoid track on an MR arthrogram can be used to risk stratify patients with shoulder instability


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1347 - 1351
1 Oct 2007
Maquieira GJ Espinosa N Gerber C Eid K

The generally-accepted treatment for large, displaced fractures of the glenoid associated with traumatic anterior dislocation of the shoulder is operative repair. In this study, 14 consecutive patients with large (> 5 mm), displaced (> 2 mm) anteroinferior glenoid rim fractures were treated non-operatively if post-reduction radiographs showed a centred glenohumeral joint. After a mean follow-up of 5.6 years (2.8 to 8.4), the mean Constant score and subjective shoulder value were 98% (90% to 100%) and 97% (90% to 100%), respectively. There were no redislocations or subluxations, and the apprehension test was negative. All fragments healed with an average intra-articular step of 3.0 mm (0.5 to 11). No patient had symptoms of osteoarthritis, which was mild in two shoulders and moderate in one. Traumatic anterior dislocation of the shoulder, associated with a large displaced glenoid rim fracture can be successfully treated non-operatively, providing the glenohumeral joint is concentrically reduced on the anteroposterior radiograph


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 173 - 177
1 Mar 2002
Schandelmaier P Blauth M Schneider C Krettek C

We describe the results after open reduction and internal fixation of 22 consecutive displaced fractures of the glenoid with a mean follow-up of ten years. A posterior approach was used in 16 patients and an anterior in six, the approach being chosen according to the Ideberg classification of the fractures. The fixation failed in two patients, one of whom required a further operation. There were two cases of deep infection. At follow-up the median Constant score was 94% (mean 79%, range 17 to 100). The score was less than 50% in four patients, including the two who became infected. A further two had an associated complete palsy of the brachial plexus


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 2 - 2
8 Feb 2024
Dixon JE Rankin IA Sciberras N Khan LAK Barker SL Cairns DA Kumar K
Full Access

In recent years, use of anatomic stemless total shoulder arthroplasty (AsTSA) has increased. Despite evidence to suggest good mid-term results at 2-year follow-up there is a paucity of evidence for longer term follow-up. This study aimed to investigate outcomes at a minimum of 5 years post-operatively following primary AsTSA. This study is a retrospective case series of all patients who underwent a Mathys Affinis AsTSA from July 2010 (first case) to August 2018 (to allow minimum 5-year follow-up). Clinical outcomes included revision rate, range of motion and patient reported outcomes (Oxford Shoulder Score and Numerical Satisfaction Score). Radiological outcome was assessment of radiolucent lines for Lazarus grading. A total of 105 stemless TSAs were implanted. Five patients underwent revision (4.8%). Seventy-five AsTSA's were included in the final study for analysis of 5-year outcomes. Median follow-up time was 6.1 years. Median age was 69 years old and 81% were female. Oxford shoulder score showed a range of 18 to 48, with a median score of 47. Satisfied or very Satisfied was selected in 94.37%. Median range of motion assessments showed forward elevation 160°, abduction 150°, external rotation 40°, and mode internal rotation was to the lumbar spine. No glenoid lucency was present in 79.7%. There were 9.5% with Lazarus Grade 1 lucency, 5.4% with Lazarus Grade 2, and 5.4% Lazarus Grade 3. No humeral lucency was observed. This cohort study demonstrates promising clinical and radiological outcomes for the Mathys Affinis Stemless TSA at minimum 5 years post-operatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 13 - 13
1 Dec 2023
Elgendy M Makki D White C ElShafey A
Full Access

Introduction. We aim to assess whether radiographic characteristics of the greater tuberosity fragment can predict rotator cuff tears inpatients with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity. Methods. A retrospective single-centre case series of 61 consecutive patients that presented with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity between January 2018 and July 2022. Inclusion criteria: patients with atraumatic anterior shoulder dislocation associated with an isolated fracture of the greater tuberosity with a minimum follow-up of 3-months. Exclusion criteria: patients with other fractures of the proximal humerus or glenoid. Rotator cuff tears were diagnosed using magnetic resonance or ultrasound imaging. Greater tuberosity fragment size and displacement was calculated on plain radiographs using validated methods. Results. The case series was composed of 22 men and 39 women with a mean age of 65 years (29 - 91 years). The mean follow-up was 15months and median follow up 8.5 months (3 – 60 months). A rotator cuff tear was diagnosed in 14 patients (16%) and involved the supraspinatus (13), infraspinatus (4) and subscapularis (2). Full-thickness tears occurred in 6 patients and partial-thickness tears in 8patients. The mean time from initial injury to rotator cuff tear diagnosis was 5 months (2 – 22 months). The mean greater tuberosity fragment length was 23.4 mm in rotator cuff tear patients versus 32.6 mm in those without a tear (p = 0.006, CI: -15 - -2). The mean greater tuberosity. fragment width was 11.1 mm in rotator cuff tear patients versus 17.8 mm in those without a tear (p = 0.0004, CI: -10 - -2). There was no significant difference in the super inferior and anteroposterior fragment displacement between the two groups. Conclusion. In patients with shoulder dislocations combined with an isolated fracture of the greater tuberosity, rotator cuff tears are associated with a smaller sized greater tuberosity fragment


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 9 - 9
1 May 2021
Gillespie MJ Nicholson JA Yapp LZ Robinson CM
Full Access

The aim of this study was to determine if the extent of the glenoid and humeral bone loss affects the rate of recurrent instability and the functional outcome following the Latarjet procedure. 161 patients underwent open Latarjet procedure during the period 2006–2015 (Mean age 30.0 years, 150t (93.2%) Male, 118 (73.3%) primary procedure). Functional outcome was measured using the Western Ontario Shoulder Instability Index (WOSI) and Quick Disabilities of the Arm, Shoulder and Hand (QuickDash) score at a mean of 4.7 years post-operatively. All patients underwent computed tomographic (CT) imaging pre-operatively. Using three-dimensional reconstruction, the glenoid bone loss, Hill-Sachs lesion and ‘Glenoid Track’ status was recorded. Radiographically-confirmed redislocation was rare (1.2%), but 18.5% (n=23/124) reported ongoing subjective shoulder instability. Fifty-two shoulders (32.3%) were classified as “Off-Track”. The median Quick DASH and WOSI scores were 2.27 (IQR 9.09; range 0–70.45) and 272.0 (IQR 546.5; range 0–2003), respectively. There were no significant differences observed between overall Quick DASH scores or WOSI scores for either On-Track or Off-Track groups (p=0.7 and 0.73, respectively). Subjective instability was not influenced by the degree of glenoid bone loss (p=0.82), the overall size of the Hill-Sachs lesion (p=0.80), or the presence of an ‘Off-Track’ lesion (p=0.84). Functional outcome and recurrent instability following the Latarjet procedure do not appear to be influenced by the extent of glenohumeral bone loss prior to surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 11 - 11
1 May 2021
Skipsey DA Downing MR Ashcroft GP Cairns DA Kumar K
Full Access

Over the last decade stemless shoulder arthroplasty has become increasingly popular. However, stability of metaphyseal loading humeral components remains a concern. This study aimed to assess the stability of the Affinis stemless humeral component using Radiostereometric analysis (RSA). Patients underwent total shoulder arthroplasty via a standardised technique with a press-fit stemless humeral component and a cemented pegged glenoid. Tantalum beads were inserted into the humerus at the time of operation. RSA of the relaxed shoulder was completed at weeks 1, 6, 13, 26, 52 and 104 post-operatively. Stressed RSA with 12 newtons of abduction force was completed from week 13 onwards. ABRSA 5.0 software (Downing Imaging Limited, Aberdeen) was used to calculate humeral component migration and induced movement. 15 patients were recruited. Precision was: 0.041, 0.034, 0.086 and 0.101 mm for Superior, Medial, Posterior and Total Point Motion (TPM) respectively. The mean TPM over 2 years was 0.24 (0.30) mm, (Mean (Standard deviation)). The mean rate of migration per 3 month time period decreased from 0.45 (0.31) to 0.02 (0.01) mm over 2 years. Mean inducible movement TPM peaked at 26 weeks at 0.1 (0.08) mm, which reduced to 0.07 (0.06) mm by 104 weeks when only 3 patients had measurable inducible motion. There was no clear trend in direction of induced movement. There were no adverse events or revisions required. We conclude migration of the humeral component was low with little inducible movement in the majority of patients implying initial and 2 year stability of the stemless humeral component


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_5 | Pages 4 - 4
1 Feb 2013
Cowie J McKenzie S Dempster N Robinson C
Full Access

First-time anterior dislocation of the shoulder is associated with the development of recurrent instability. It is recognised that patients with recurrent instability often have osseous defects. Using 3D computerised tomography (3DCT) it is possible to quantify these defects. Whether these defects are present after the primary dislocation or occur progressively from multiple dislocations is unclear. We correlated the presence of Hill-Sachs lesions and anterior glenoid bone loss with evidence of recurrent dislocation and clinical outcomes. 78 patients were followed up for two years. All underwent a 3DCT within a week of injury. Standardised images of the humeral head and glenoid were produced. Using standardised digital techniques bone loss was measured. 39% of the patients developed further instability. Average Hill-Sachs circumferential length = 15.23%. Average Hill-Sachs surface area = 5.53%. The length and surface area of the Hill-Sachs lesions were significantly associated with further instability. (p=0.019 and p=0.003). Average en face glenoid surface area loss=1.30% with no association to instability (p=0.685). There was poor correlation between the size of the glenoid lesion and the size of the Hill-Sachs lesion. Results showed that age and increasing size of the Hill-Sachs lesions result in a higher rate of instability. Interestingly glenoid bone loss was relatively low and did not predict recurrent instability. The size of the Hill-Sachs lesion does not have a linear relationship with glenoid bone loss. Further work defining the morphology of the Hill-Sachs lesion and its engagement with a glenoid defect is required


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 24 - 24
1 Sep 2012
Favard L Young A Alami G Mole D Sirveaux F Boileau P Walch G
Full Access

Purpose. to analyze the survivorship of the RSA with a minimum 10 years follow up. Patients and Methods. Between 1992 and 1999, 145 Delta (DePuy) RSAs have been implanted in 138 patients. It was a mulicentric study. Initial etiologies were gathered as following: group A (92 cases) Cuff tear arthropaties (CTA), osteoarthritis (OA) with at least 2 involved cuff tendons, and massive cuff tear with pseudoparalysis (MCT); group B (39 cases) -failed hemiarthroplasties (HA), failed total shoulder arthroplasties (TSA), and fracture sequelae; and group C (14 cases) rheumatoid arthritis, fractures, tumor, and instability. Survival curves were established with the Kaplan-Meier technique. Two end-points were retained: -implant revision, defined by glenoid or humeral replacement or removal, or conversion to HA; - a poor clinical outcome defined by an absolute Constant score of less than 30. Results. At the time of review, 47 patients had died with their prosthesis in place and 30 were lost to follow-up. There were 12 revisions, 6 for infections, 3 for glenoid loosening, 1 for dislocation, 1 for glenoid dissociation (by unscrewing), and 1 for humeral loosening. The survival curve to prosthetic removal showed an overall survivorship of 92% at 10 years. Segmentation according to etiology showed a 97% survivorship for group A and 88% for group B This difference was not significant. No patients of group C had a minimum follow up of ten years because there were died or lost to follow up. The survival curve to a Constant score of less than 30 showed an overall survivorship of 90% at 10 years. Segmentation according to etiology showed a significant difference at 10 years in favor of group A (92%) compared to group B (86%) with a break of the curve after 9 years for group B. Discussion. Our results show that the overall survivorship of the reverse shoulder prosthesis to removal is good even 10 years after implantation, in particular if it had been implanted for CTA, OA, or MCT. However, functional results did deteriorate progressively after 9 years in particular if it had been implanted for revision (HA or TSA). Therefore, extreme caution must be observed in relation to the indications for reverse shoulder arthroplasty, especially in younger patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 529 - 529
1 Sep 2012
Schoenahl J Gaskill T Millett P
Full Access

Introduction. Osteoarthritis of the glenohumeral joint leads to global degeneration of the shoulder and often results in humeral or glenoid osteophytes. It is established that the axillary neurovascular bundle is in close proximity to the glenohumeral capsule. Similar to other compressive neuropathies, osteophytic impingement of the axillary nerve could result in axillary nerve symptoms. The purpose of this study was to compare the proximity of the axillary neurovascular bundle to the inferior humerus in shoulders to determine distance of the neurovascular bundle as the osteophyte (goat's beard) of glenohumeral osteoarthritis develops. Methods. In this IRB approved study, preoperative MRI's of 98 shoulders (89 patients) with primary osteoarthritis (OA group) were compared to 91 shoulders (86 patients) with anterior instability (Control group). For MRI measurements (mm) two coronal-oblique T1 or proton density weighted images were selected for each patient located at 5 and 6 o'clock position of the glenoid in the parasagittal plane. Humeral head diameter to standardize the glenohumeral measurements, size of the spurs, and 6 measurements between osseus structures and axillary neurovascular bundle were obtained on each image using a calibrated measurement system (Stryker Office PACS Power Viewer). Level of significance was set at p>.05. Results. Since results were both significant at 5 and 6 o'clock, for clarity we will only give the results at 6 o'clock. Humeral head osteophytes were present in 52% (51/86) of arthritic patients with an average size of 9.90 mm (range 0–24.31). Distance between humeral head or inferior osteophyte and neurovascular bundle was significantly decreased (p<0.05) in the OA group, 19.74 mm (range 2.80–35.12) compared to the control group 23.8 mm (14.25–31.89). If we compare the same distance between the Control group, OA group with a spur and OA group without a spur, the difference is only significant between the Control group and OA with spur. (p<0.05) In non-arthritic patients, the neurovascular bundle was closest to the inferior glenoid rim in all patients (91/91). By contrast, the neurovascular bundle was closest to the humeral head in 26.5% (26/98) of arthritic patients. Among these 26 patients, a large humeral head osteophyte was present in 96% (25/26). The neurovascular bundle distance and humeral head osteophyte size were inversely correlated (r=−0.45 at 5 o'clock, r=−0.546 at 6 o'clock) in the arthritic group (p<0.05). Discussion. The axillary neurovascular bundle was significantly closer to the osseous structures (humerus) in arthritic patients compared to non-arthritic patients (p<0.05). The neurovascular bundle was significantly closer to the bone when there was a humeral osteophyte, and the distance was inversely proportional to humeral osteophyte size (p<0.05). This study indicates humeral osteophytes are capable of encroaching on the axillary nerve. Axillary nerve entrapment may be a contributing and treatable factor of pain in patients with glenohumeral osteoarthritis


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1063 - 1069
1 Jun 2021
Amundsen A Brorson S Olsen BS Rasmussen JV

Aims

There is no consensus on the treatment of proximal humeral fractures. Hemiarthroplasty has been widely used in patients when non-surgical treatment is not possible. There is, despite extensive use, limited information about the long-term outcome. Our primary aim was to report ten-year patient-reported outcome after hemiarthroplasty for acute proximal humeral fractures. The secondary aims were to report the cumulative revision rate and risk factors for an inferior patient-reported outcome.

Methods

We obtained data on 1,371 hemiarthroplasties for acute proximal humeral fractures from the Danish Shoulder Arthroplasty Registry between 2006 and 2010. Of these, 549 patients (40%) were alive and available for follow-up. The Western Ontario Osteoarthritis of the Shoulder (WOOS) questionnaire was sent to all patients at nine to 14 years after primary surgery. Revision rates were calculated using the Kaplan-Meier method. Risk factors for an inferior WOOS score were analyzed using the linear regression model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 23 - 23
1 Sep 2012
Petroff E Petroff E Audebert S Delobelle JM
Full Access

We evaluated the results of Cementless Surface Replacement Arthroplasty (CSRA) of the shoulder in 67 patients with advanced glenohumeral destruction who have an intact rotator cuff. Between november 2002 and december 2008, 70 CSRA (32 Copeland/ Biomet and 38 SMRR/ Lima) were implanted in 67 patients. A deltopectoral approach was used in 34 cases and an anterosuperior approach in 36 cases. Patients were assessed using Constant score, a patient satisfaction score and a detailed radiographic analysis. The mean follow up was 3.4 years (range 1 to 7.5 years). The mean Constant score improved preoperatively from 17.6 points (range 2–55) to an average postoperative score of 66.1 (range 13–91). The pain score improved from 1.13 points (range 0–6) to 12.3 points (range 3–15). The forward flexion and external rotation improved from 71° (range 20 to 140) and 0° (range −40 to +45) to 143° (range 60 to180) and 34.4° (range −20 to +60) respectively. Complications included: 1 subscapularis detachment, 5 secondary rotator cuff tear, 1sepsis, 3 patients with shoulder stiffness. No shift in implant position was observed. 11 humeral components developed radiolucencies at the prosthesis-bone interface. The radiographic analysis involved a system of dividing the prosthesis/bone interface into 5 zones. The best clinical results were significantly achieved in patients with necrosis compared with osteoarthritis (Constant Score, ant. elevation, ext. Rotation). Using regression analysis we found that changes in the head-shaft angle position of the implant (valgus/varus placement of the CSRA) significantly predicted the age and sex adjusted Constant score. When the inclination angle of the humeral head decreases, the adjusted Constant score increases. In the same model, we also found that the lateral offset of the humerus significantly predicted the adjusted Constant score. When the lateral offset of the humerus decreases, the adjusted Constant score increases. The medialization of the glenoid significantly and negatively predicted the Constant score. Conclusion. CSRA of the shoulder outcomes have been comparable with those of stemmed arthroplasties. Radiolucent lines occur with follow up and most of the time located in the S1 area. Glenoid wear and humeral head lateralization negatively impact the clinical score. Cementless Shoulder resurfacing is a viable alternative to conventional shoulder arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 108 - 108
1 Sep 2012
Pailhé R Reina N Laffosse JM Tricoire JL Chiron P Puget J
Full Access

Background. Floating shoulder (FS) is, according to Goss et al, a double disruption of the superior shoulder suspensory complex which usually results from a glenoid neck fracture and a ipsilateral midclavicular fracture. However, the interruption can interest the whole scapular belt from acromion to sterno-clavicular joint. It occurs mostly after a violent traumatism with direct lateral impact on the shoulder. That leads to complex therapeutic issues with sometimes uncertain results. Material. Between 1984 and 2009, 35 patients (30 men, 5 women), mean age 35 years [16–72] with FS, were treated in our department. Most of them sustained road accident (31cases) with polytraumatism context in 12 cases. A CT scan was realized in the majority of cases to specify the scapular fracture and look for intra-thoracic immediate complications. Mostly, glenoid neck fracture associated with a clavicular fracture has been found out (15cases). Orthopaedic treatment has been realized in 18 cases. Surgical management has been decided for open reduction of sterno-clavicular joint in 2 cases, isolated fixation of the clavicle in 9 cases, of the scapula in 3 cases, and of both scapula and clavicle in 3 cases. Criteria for clinical evaluation were an algo-functional scale (Oxford Shoulder Score, OSS), a subjective Constant Shoulder Score, a functional incapacity scale (Shoulder Simple Test, SST), scales of life quality (DASH and SF12) and global indications (Single Assessment Numeric Evaluation, SANE). Results. we noted a single migration of material. A patient presented a secondary displacement after orthopaedic treatment, and had additional surgical fixation before 6 months. In the mean follow up of 135 months [9–312], three patients were deceased and seven were unreachable. Five complained about rare pains, three of an important stiffness and chronic pains, and only one of brachial plexus injury. Functional results were satisfactory: OSS 14,75/60 [12–28], Subjective Constant score 79 [60–100], SST 10,75/12 [4–12], DASH 13,75/100 [0–84], SF12 physical 49,4 [36,8–54,8], SF12 mental 59,7 [57,2–61,8] andSANE 79% [50–100]. Discussion/conclusion. FS presents an immediate gravity because of possible intrathoracic injuries which can delay surgical treatment. FS which allowed orthopaedic treatments or required isolated fixation of the clavicle have excellent results. Scapular fractures which required surgical repair because of a significant displacement andan articular extension have more pejorative results


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 795 - 798
1 Aug 2001
van Noort A te Slaa RL Marti RK van der Werken C

The aim of this retrospective study was to review a series of patients with ipsilateral fractures of the neck of the scapula and of the clavicle. Between 1991 and 1996 a total of 79 general and orthopaedic surgeons treated 46 patients with a floating shoulder in The Netherlands. The records and radiographs of these patients were studied. Of the 35 patients available for follow-up, 31 had initially been treated conservatively and four by operation; three underwent secondary reconstructive surgery. The mean Constant score for the 28 patients treated conservatively was 76 and for the seven treated operatively it was 71 at a mean follow-up of 35 months. In six of the 28 patients treated conservatively the glenoid was dislocated caudally at the end of treatment; they had a score of 42. In the 22 patients without this dislocation the score was 85. We conclude that this rare injury is not inherently unstable and, in the absence of caudal dislocation of the glenoid, conservative treatment gives a good functional outcome


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 3 - 3
1 Feb 2013
Harrold F Wigderowitz C
Full Access

Shoulder arthroplasty is the treatment of choice for a range of degenerative diseases. However, long term follow-up suggests almost half of patients graded their treatment as unsatisfactory. Component malalignment is thought the most likely cause. The anterior anatomical neck is used as a reference for the osteotomy. The objective of the study was to analyse the cartilage/metaphyseal interface to identify reference points that may recover version accurately. Twenty-four humeri were scanned using a Microscribe digitiser and surface laser scanner. Modelling software was used to analyse the Cartilage/metaphyseal interface. The retroversion angle was calculated for the normal geometry and for the standard osteotomy. An ideal osteotomy plane was then created for each specimen and the distance from the cartilage/metaphyseal interface determined, identifying points of least deviation. The reference points were used to simulate a new osteotomy for which retroversion was calculated. The novel osteotomy and traditional osteotomy were compared to the normal geometry. The mean retroversion for the normal geometry was 18.5±9.0 degrees. The mean retroversion for the traditional osteotomy technique was 29.5±10.7 degrees, significantly different from the original (p<0.001). The mean retroversion using the novel osteotomy was 18.9±8.9 degrees and similar to the normal geometry (p=0.528). The traditional osteotomy resulted in a mean increase in retroversion of 38%. The increase in version may result in eccentric loading at the glenoid and alter rotator cuff balance. The novel osteotomy resulted in more accurate recovery of head geometry and may improve clinical outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 70 - 70
1 Sep 2012
Cazeneuve J Cazeneuve J Hassan Y Hilaneh A
Full Access

This clinical study analyzes the long-term outcomes and potential complications of the Grammont's reverse prosthesis in case of trauma in elderly population. Between January 1993 and May 2010, thirty-seven consecutive patients with 26 three- and four-part fractures and 11 fracture-dislocations, mean age 75 (58 to 92) were evaluated with a mean follow-up of 7.3 years. Eight complications occurred: 2 complex sympathetic dystrophies, 3 dislocations, 2 deep infections and one aseptic loosening of the base-plate leading to 3 re-operations and 2 prosthesis revisions. The mean Constant's score dropped from 55 at two year follow-up to 52 (20 to 84) at last revision because of an augmentation of the pain and a diminution of the strength which represented 67% of the mean score for the injured side. Mean modified Constant's score was 68. Only 58% were satisfied or very satisfied because of poor internal and external rotations avoiding nourishment with utensils, dressing and personal hygiene when the dominant side was involved. Two complete glenoid borders, fourteen stable inferior spurs, twenty-one inferior scapular notches including ten of them with medial proximal humeral bone loss or radio lucent lines between the bone and the cement were observed. Notches were more important in size when the follow-up was longer. 62% of the patients had worrying images. The crossing of the clinical and radiological data showed a degradation of the mean Constant's score (41) for pain and strength in cases of notches with troubling proximal humeral images. In spite of only one case of aseptic loosening at 12 year follow-up, results are disappointing and complications and revisions rates important. The functional result is never equal to the pre-broken state. New developments in design, bearing surfaces and surgical technique and a more long term results will refine the role of the reverse concept for fracture


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 25 - 25
1 Sep 2012
Sadoghi P Vavken P Leithner A Müller P Hochreiter J Weber G
Full Access

Introduction. Insufficient arthroscopic cuff tear reconstruction leading to massive osteoarthritis and irreparable rotator cuff tears might be salvaged by implantation of an inverted total shoulder prosthesis Delta in the elderly. However, despite the generally high success rate and satisfying clinical results of inverted total shoulder arthroplasty, this treatment option has potential complications. Therefore, the objective of this study was a prospective evaluation of the clinical and radiological outcome after a minimum of 2 years follow-up of patients undergoing inverted shoulder replacement with or without prior rotator cuff repair. Patients and Methods. Sixty-eight shoulders in 66 patients (36 women and 30 men) operated between February 2002 and June 2007 with a mean age of 66 years (ranging from 53 to 84 years) were first assessed preoperatively and then at minimum 2 years follow-up, using the Constant score for pain, Constant Shoulder Score, Oxford Shoulder Score, UCLA Shoulder rating scale, DASH Score, Rowe Score for Instability and Oxford Instability Score. 29 patients (Group A) had undergone previous shoulder arthroscopy for cuff tear reconstruction at a mean of 29 months (range 12 to 48 months) before surgery and 39 patients (Group B) underwent primary implantation of an inverted total shoulder prosthesis Delta. Any complications in both groups were assessed according to Goslings and Gouma. Results. We report statistically significant improvements of all obtained scores at a mean follow-up of 42 months (ranging from 24 to 96 months) in both groups. Significant outcome differences between 29 patients with previous shoulder arthroscopy for cuff tear reconstruction and 39 without previous shoulder arthroscopy were not observed. Eight complications occurred altogether, in terms of a nerve lesion once, loosening of the humeral stem three times, and loosening or fracture of the glenoid component four times. Conclusion. We did not detect any statistically significant impact of previous insufficient shoulder arthroscopy for cuff tear reconstruction on the outcome and survival rate after the implantation of the inverted total shoulder prosthesis Delta. We conclude that reverse total shoulder arthroplasty with the Delta prosthesis is significantly beneficial in terms of less shoulder pain, higher stability and gain of range of motion without this beneficial effect being significantly weakened by previous insufficient shoulder arthroscopy for cuff tear reconstruction. We believe that previous arthroscopic cuff tear reconstruction should therefore be included in the treatment algorithm


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 116 - 116
1 Sep 2012
Murray I Shur N Olabi B Shape T Robinson C
Full Access

Background. Acute anterior dislocation of the glenohumeral joint may be complicated by injury to neighboring structures. These injuries are best considered a spectrum of injury ranging from an isolated dislocation (unifocal injury), through injuries associated with either nerve or osteoligamentous injury (bifocal injury), to injuries where there is evidence of both nerve and osteoligamentous injury. The latter combination has previously been described as the “terrible triad,” although we prefer the term “trifocal,” recognizing that this is the more severe end of an injury spectrum and avoiding confusion with the terrible triad of the elbow. We evaluated the prevalence and risk factors for nerve and osteoligamentous injuries associated with an acute anterior glenohumeral dislocation in a large consecutive series of patients treated in our Unit. Materials and Methods. 3626 consecutive adults (mean age 48yrs) with primary traumatic anterior shoulder dislocation treated at our unit were included. All patients were interviewed and examined by an orthopaedic trauma surgeon and underwent radiological assessment within a week of injury. Where rotator cuff injury or radiologically-occult greater tuberosity fracture was suspected, urgent ultrasonography was used. Deficits in neurovascular function were assessed clinically, with electrophysiological testing reserved for equivocal cases. Results. Unifocal injuries occurred in 2228 (61.4%) of patients. There was a bimodal distribution in the prevalence of these injuries, with peaks in the 20–29 age cohort (34.4% patients) and after the age of 60 years (23.0% patients). Of the 1120 (30.9%) patients with bifocal dislocations, 920 (82.1%) patients had an associated osteotendinous injury and 200 (17.9%) patients had an associated nerve injury. Trifocal injuries occurred in 278 (7.7%) of cases. In bifocal and trifocal injuries, rotator cuff tears and fractures of the greater tuberosity or glenoid were the most frequent osteotendinous injuries. The axillary nerve was most frequently injured neurological structure. We were unable to elicit any significant statistical differences between bifocal and trifocal injuries with regards to patient demographics. However, when compared with unifocal injuries, bifocal or trifocal injuries were more likely to occur in older, female patients resulting from low energy falls (p<0.05). Conclusions. We present the largest series reporting the epidemiology of injury patterns related to traumatic anterior shoulder dislocation. Increased understanding and awareness of these injuries among clinicians will improve diagnosis and facilitate appropriate treatment


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 36 - 36
1 Sep 2012
Rasmussen J Sorensen AK Olsen B
Full Access

Objective. To describe demographic data, clinical outcome and short-term survival after shoulder arthroplasty. Materials and Methods. The Danish Shoulder Arthroplasty Register was established in 2004. All 40 Danish hospitals and private clinics where shoulder arthroplasty are performed are participating. Since 2006 where the reporting to the register became mandatory the compliance of reporting has been 88.9%. Data are collected by an internet based clinical measuring system where the orthopaedic surgeon report data such as diagnosis, type of arthroplasty, and demographic data. The follow-up results are collected by sending a questionnaire to the patient 10–14 month after the operation. The questionnaire contains a Western Ontario Osteoarthritis of the Shoulder index (WOOS). Each question is answered on a visual analogue scale with a possible score ranging from 0–100. There are 19 questions and the total score is ranging from 0–1900. For simplicity of presentation the raw scores is converted to a percentage of a normal shoulder. Results. 2320 Shoulder arthroplasties were reported to the register between 2006 and 2008. There were 69.4% women. Median age was 70.6, range 16.3–96.3. 699 arthroplasties (30.0%) were due to osteoarthritis, 98 (4.2%) due to arthritis, 1182 (50.9%) due to a proximal humeral fracture, 179 (7.4%) due to rotator cuff arthropaty, 62 (2.7%) due to caput necrosis and 79 (3.4%) due to other pathology condition such as cancer and revision surgery. 1352 (58.3%) were stemmed hemi arthroplasty, 77 (3.3%) total shoulder arthroplasty, 596 (25.7%) resurfacing arthroplasty and 243 (10.5%) reverse shoulder arthroplasty. 1288 patients (55.5%) returned a complete questionnaire. Median WOOS for all arthroplasties was 58.2, range 0.0–100.0. Median WOOS for arthritis was 59.3, range 13.3–99.8, osteoarthritis 67.9, range 0.0–100.0, a proximal humeral fracture 54.2, range 0.0–100.0, rotator cuff arthropaty 65.6, range 0.0–98.3 and caput necrosis 48.9, range 3.9–95.2. 171 (7.4%) operations were revisions. The most common indications of revision were luxation (2.2%), infection (1.3%), loosening (0.7%) and glenoid attrition (0.6%). Conclusion. To our knowledge there is no previous study with such a large population presenting demographic data and clinical outcome after shoulder arthroplasty. We found good results for the groups of patients diagnosed with osteoarthritis, arthritis and cuff arthropaty. There were poorer results in the groups of patient diagnosed with a proximal humeral fracture and especially caput necrosis