Advertisement for orthosearch.org.uk
Results 1 - 20 of 113
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 151 - 157
1 Feb 2024
Dreyer L Bader C Flörkemeier T Wagner M

Aims

The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection.

Methods

We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 14 - 14
1 Apr 2022
Amer M Assaf A Dunlop DG
Full Access

Fixation only of Vancouver B Proximal Femoral Fractures (PFF's), specifically with Cemented Taper Slip stems (CTS) with an intact bone cement interface, has been shown to have reduced blood transfusion requirements and reoperations, compared to revision arthroplasty. This potentially carries the risk of stem subsidence and loosening, which negatively impacts functional outcome. The incidence of stem subsidence and associated fracture morphology have not previously been reported. We retrospectively reviewed all Vancouver B PFF's in primary THR around CTS stems treated with internal fixation only between June 2015 and March 2021 for fracture morphology (Low Spiral (LS), High Spiral (HS), Metaphyseal Split (MS) and Short Oblique (SO)), fracture union and stem subsidence. Interprosthetic fractures and inadequate follow up were excluded. Secondary outcomes were collected. Out of 577 cases on our local periprosthetic database, 134 Vancouver B PFF's around CTS stems were identified, of which 77 patients underwent ORIF only. Of these, 50 procedures were identified, 21 were lost to follow up and 6 patients died before 6 months. Age, mortality rate and ASA is presented. Review of Fracture morphology showed: 100% (3/3) of HS subsided (1 revised for loosening); 68 % (19/28) of MS subsided (1 revised for loosening); 11.1 % (2/18) of LS subsided (0 revised for loosening); 0% (1/1) of SO subsided. There were 2 revisions for non-union (LS group). No dislocations were recorded. There was a statistically significant association between Morphology and Subsidence P value 0.0004). Major subsidence was observed in 8 patients (3 HS, 4 MS and 1 LS) which was associated with a significance reduction in mobility. Subsidence was associated with negative symptoms (P value < 0.0001). Fixation of all Vancouver B PFF's does not produce uniformly good results. Revision rates following ORIF do not fully reflect patient outcomes. This trend will affect the NJR, stem rating and patient satisfaction. Subsidence after ORIF was associated with certain morphologies (HS & MS) and stem revision may be preferrable, in keeping with GIRFT. A morphology-based classification system can inform decision making


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 51 - 51
2 May 2024
Diffley T Yee T Letham C Ali M Cove R Mohammed I Kindi GA Samara A Cunningham C
Full Access

Extracapsular Hip Fractures (EHF's) are a significant health burden on healthcare services. Optimal treatment is controversial with conflicting evidence being reported. Currently treatment is undertaken with Intramedullary Nail (IMN) or Dynamic Hip Screw (DHS) constructs with a recent increase in IMN use (1). This study aims to conduct a systematic review of Randomised Control Trials published between 2020 and 2023 with particular focus on patient demographics and holistic patient outcomes. Using a unified search-protocol, RCT's published between 2020 and 2023 were collected from CENTRAL, PubMed, MEDLINE and EMBASE. Rayyan software screened duplicates. Using the CASP and Cochrane Risk of Bias Tool papers were critically examined twice, and Blood Loss, Infection and Mobility described the patient journey. Patient demographics were recorded and were contrasted with geographically diverse cohort studies to compare population differences. Parametric tests were used to determine significance levels between population demographics, namely Age and Sex. Eleven papers were included, representing 908 patients (436 Male). The mean age for patients was 64.39. There was considerable risk of bias in 7/11 studies owing to the randomization process and the recording of data. Four Cohort studies were selected for comparison representing 14314 patients. Mean age was significantly different between Cohort Studies and RCT's (Independent T-Test, df 13, t=7.8, p = <0.001, mean difference = 19.251, 95% CI = 13.888, 24.613). This was also true for sex ratios included in the studies (df 13, t = -2.268, p = 0.024, Mean Difference = -0.4884, 95% CI = -0.9702, -0.0066). To conclude, RCT's published in the post COVID-19 era are not representative of patient demographics. This has the potential to provide inaccurate information for implant selection. Additionally further research must be conducted in how to better improve RCT patient inclusion so as to be more representative of patients whilst balancing the risks of operations


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 32 - 32
1 Aug 2021
Powell-Bowns M Oag E Ng N Patton J Pandit H Moran M Clement N Scott C
Full Access

The aim of this study is to determine whether fixation, as opposed to revision arthroplasty, can be safely used to treat reducible Vancouver B type fractures in association with a cemented collarless polished tapered femoral stem (the Exeter). This is a retrospective cohort study of 152 operatively managed consecutive unilateral Vancouver B fractures involving Exeter stems. 130 were managed with open reduction and internal fixation (ORIF) and 22 with revision arthroplasty. Radiographs were assessed and classified by 3 observers. The primary outcome measure was revision of ≥1 component. Kaplan Meier survival analysis was performed. Logistic regression was used to identify risk factors for revision following ORIF. Secondary outcomes included any reoperation, complications, blood transfusion, length of hospital stay and mortality. Fractures (B1 n=74 (49%); B2 n=50 (33%); and B3 n=28 (18%)) occurred at mean 6.7±10.4 years after primary THA (n=143) or hemiarthroplasty (n=15). Mean follow up was 6.5 ±2.6 years (3.2 to 12.1). Rates of revision and reoperation were significantly higher following revision arthroplasty compared to ORIF for B2 (p=0.001) fractures and B3 fractures (p=0.05). Five-year survival was significantly better following ORIF: 92% (86.4 to 97.4 95%CI) Vs 63% (41.7 to 83.3), p<0.001. No independent predictors of revision following ORIF were identified: fixation of B2 or B3 fractures was not associated with an increased risk of revision. Dislocation was the commonest mode of failure after revision arthroplasty. ORIF was associated with reduced blood transfusion requirement and reoperations, but there were no differences in medical complications, hospital stay or mortality between surgical groups. When the bone-cement interface was intact and the fracture was anatomically reducible, Vancouver B2 fractures around Exeter stems can be treated with fixation as opposed to revision arthroplasty. Fixation of Vancouver B3 fractures can be performed in frail elderly patients without increasing revision risk


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 41 - 41
1 Aug 2018
Thaler M Krismer M Dammerer D Ban M Nogler M
Full Access

In recent years, the direct anterior approach (DAA) has become a standard approach for primary total hip arthroplasty (THA). With the increasing use of the DAA in primary cases also more and more revision surgeries are performed through the same interval. With ability to extend the DAA interval proximally and distally, loose cups, loose stems, and even periprosthetic femoral fractures (PPF) can be treated. Especially, PPF are devastating complications causing functional limitations and increased mortality. Therefore, we conducted a study to report the outcome of surgical treatment of PPF with the DAA interval. We report on the one year complications and mortality in 40 cases with a mean clinical follow-up of 1.5 years. Mean age of patients was 74.3 years. Fractures were classified as Vancouver B2 (36), and B3 (N=4). In 14 cases, a standard stem was used, and in 26 cases a modular revision stem. In 30 cases, a distal extension +/- tensor release was used, in 4 cases a proximal tensor release was done, and in the remaining 6 cases revision could be performed without extension of the approach. Median cut/suture time was 152 minutes (IQR 80 – 279). The overall complication rate in our patient group was 12.5%. 2 patients died in the first three months after operation. One patient had a transient femoral nerve palsy, which completely recovered. The DAA interval to the hip for the treatment of PFF showed similar results compared with other approaches regarding mortality, complications, fracture healing, dislocation rate and clinical results. We conclude that femoral revision in case of PPF in the DAA interval is a safe and reliable procedure. Each Vancouver type of periprosthetic fracture can be treated by use of this approach


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 51 - 51
23 Jun 2023
Adeyemo EA Riepen DW Collett GA Au BK Huo MH
Full Access

The current evidence favors replacement for the treatment of displaced femoral neck fractures in the older patients. Controversies remain whether total hip replacement (THR), or hemiarthroplasty (HA) would result in better outcomes. The purpose of this study is to compare the outcomes, and the complications in patients who underwent THR or HA for displaced femoral neck fractures.

There were 345 consecutive patients who had undergone either a THR or HA at a single institution. THR was done in 137, and HA was done in 208 patients, respectively. Standard peri-operative data were collected.

The mean values for the data in the THR group are: age 69 years, ASA 2.7, OR time was 99 minutes, estimated blood loss 354 ml, and the length of stay 8 days. The mean values for the data in the HA group are: age 75 years, ASA 3.0, OR time 88 minutes, estimated blood loss 200 ml, and the length of stay 10 days. The overall complications were 8.8% (THR), and 9.1% (HA), respectively. The mortality rates for the patients were: at the 1-year (9.5% THR vs 16.3% HA), at the 3-year (15.3% THR vs 24.0% HA), and at the 5-year (19.7% THR vs 26.9% HA), respectively.

Our data demonstrated similar peri-operative data and short-term complications between the two groups. There was a difference in the mortality rates between the two groups at all 3-time intervals following the surgery. This could be a reflection of the patient selection bias for each of the operations.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 42 - 42
1 Jan 2018
Dammerer D Putzer D Wimmer M Glodny B Petersen J Biedermann R Krismer M
Full Access

We aimed to investigate the clinical consequences of intraoperative acetabular fractures. Between 2003 and 2012, a total of 3391 cementless total hip arthroplasties (THA) were performed at the Dept. of Orthopaedics, Innsbruck Medical University. Of those, a total of 160 patients underwent a CT scan within 30 days postoperatively. The scans of 44 patients were not suitable for analyse due to thick scan layers. Of the remaining 116 patients, 76 had a fracture. Reasons for CT-scans were suspected bleeding, hip pain, abdominal symptoms, etc. The fractures included 59 isolated acetabular fractures, the rest of fractures was in the superior or inferior pubic ramus or the tuber ischiadicum. Four cases out of the 59 acetabular fractures underwent revision surgery due to periprosthetic joint infection after 0, 2, 10 and 23 months. Four patients underwent revision due to cup loosening after 13 and 14 days as well as after 16 and 24 months. Of those, three showed a central acetabular fracture with protrusion. In 33 of the remaining 51 patients, a minimum of 3 x-rays was available for migration analysis with EBRA. In 6 patients, the x-rays were not comparable to each other. The 27 remaining acetabular fractures were categorised according to AO classification in 62A1 (1; posterior wall), 62A2 (16; posterior column), 62A3 (6; anterior wall), and others (4). Four hips showed initial migration of more than 3 mm in the first 6 months. One had a central fracture, and was lost for follow-up after 8 months. Two had an anterior column fracture and showed no further migration after 6 months. One showed also a radiolucency of more than 2 mm in all 3 zones and was lost for follow-up. We conclude that intraoperative acetabular fractures occur more often than we expected. Fractures of the acetabular ring involving one column do not seem to compromise the long-term stability of the implant. Central fractures required revision or showed loosening proved by high cup migration


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 48 - 48
19 Aug 2024
Falez F Casella F Zaccagno S
Full Access

Post-operative peri-prosthetic femoral fracture (PO-PPFF) is one of the most relevant complications in primary Total Hip Arthroplasty (pTHA), accountable for a significant clinical and socio-economic burden both in revision and fixation settings.

We retrospectively reviewed of our series of 1586 cementless total hip arthroplasty performed between 1999 and 2019 (achieving a minimum of 5-years follow-up) with different short stems.

We have observed a cumulative low incidence of PO-PPFF of 0,33% (5 cases): we divided Po-PPFF in two groups: fracture occurred around a short stem (A) and around a standard shortened stem (B), according to French Hip & Knee Classification of Short Stems.

Despite the length of observed period (mean follow-up 12 years, min 5 years max 24 years) a total of 1512 cases (mean age at surgery 61 years, max 74, min 40 years) were available to clinical and radiographic follow-up, being this population enrolled in elective surgery clinical protocols.

Our data exceed the low incidence of post-operative femoral fracture around bone -preserving previously reported by Kim in 2018 (12 fracture out of 1089 cases:1.1%).

No correlation have been observed among occurrence of PO-PPF age of the patient and no fracture occurred around cemented short stems despite patient's characteristics were unfavourable in term of age and bone quality. This result is not unexpected, giving the lower incidence of peri-prosthetic fracture even cemented conventional stems, as reported in all registry and systematic reviews.

A similar behaviour was reported in 2020 Australian Joint Registry, where Post-operative periprosthetic femoral fracture showed a steep curve in early period, but remaining firmly below 1% during the following 12 years.

Our clinical data seems to confirm previous studies by Jones (conducted on synthetic bone and fresh-frozen cadaveric femurs) where higher fracture angles and higher fracture torque were detected in short hips compared to standard stems.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 57 - 57
2 May 2024
Martin A Alsousou J Chou D Costa M Carrothers A
Full Access

Current treatment options for displaced acetabular fractures in elderly patients include non-surgical management, surgical fixation and surgical fixation with simultaneous hip replacement, the so-called “fix-and-replace”™. There remains a paucity of evidence to guide surgeons in decision making for these difficult injuries. The aim of this study was to assess the feasibility of performing an appropriately powered RCT between treatment options for acetabular fractures in older patients.

This was an NIHR funded feasibility triple-arm RCT with participation from 7 NHS MTCs. Patients older than 60 were recruited if they had an acetabular fracture deemed sufficiently displaced for the treating surgeon to consider surgical fixation. Randomisation was performed on a 1:1:1 basis. The three treatment arms were non-surgical management, surgical fixation and fix-and-replace. Feasibility was assessed by willingness of patients to participate and clinicians to recruit, drop out rate, estimates of standard deviation to inform the sample size calculation for the full trial and completion rates to inform design of a future definitive trial. EQ-5D was the primary outcome measure at 6 months, OHS and Disability Rating Index were secondary outcome measures.

Of 117 eligible patients, 60 were randomised whilst 50 declined study participation. Nine patients did not receive their allocated intervention. Analysis was performed on an intention to treat basis. During the study period 4 patients withdrew before final review, 4 patients died and 1 was lost to follow-up. The estimated sample size for a full scale study was calculated to be 1474 participants for an EQ-5D MCID of 0.06 with a power of 0.8.

This feasibility study suggests a full scale trial would require international collaboration. This study also has provided observed safety data regarding mortality and morbidity for the fix-and-replace procedure to aid surgeons in the decision-making process when considering treatment options.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 44 - 44
19 Aug 2024
Park C Lim S Park Y
Full Access

Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF.

A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design geometry using the system proposed by Radaelli et al. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12‒139 months).

Overall, 45 (1.4%) postoperative PFFs occurred. The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 vs. 0.7 vs. 0.7%; P=0.022). Additionally, more surgical treatments (1.7 vs. 0.5 vs. 0.7%; P=0.013) and femoral revisions (1.2 vs. 0.2 vs. 0%; P=0.004) were required for PFF in type B1 stems. After controlling for confounding variables, older age (P<0.001), diagnosis of hip fracture (P<0.001), and use of type B1 stems (P=0.001) were significant factors associated with PFF.

Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients with compromised bone quality.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 53 - 53
23 Jun 2023
Schemitsch EH Nowak LL De Beer J Brink O Poolman R Mehta S Stengel D Bhandari M
Full Access

We aimed to use data from a randomized controlled trial (RCT) comparing the sliding hip screw vs. intramedullary nailing (IMN) for trochanteric fractures to examine complication rates between those managed with a short vs. long IMN.

This is a secondary analysis using one arm of an RCT of patients ≥18 years with trochanteric fractures. We examined differences in fracture-related (femoral shaft fracture, implant failure, surgical site infection (SSI), nonunion, limb shortening, and pain) and medical (organ failure, respiratory distress, stroke, deep vein thrombosis [DVT] gastrointestinal upset, pneumonia, myocardial infarction, sepsis, or urinary tract infection) adverse events (AE), and readmission between short vs. long IMNs.

We included 412 trochanteric fracture patients, 339 (82.2%) of whom received a short (170mm–200mm) nail, while 73 (17.7%) received a long (260mm–460 mm) nail. Patients in the long group were more likely to be admitted from home (vs. an institution), and have comorbidities, or more complex fracture types.

Patients in the long group had higher rates of fracture-related AE (12.3%) vs. the short group (3.5%). Specifically, SSI (5.5% vs. 0.3%) and pain (2.7% vs. 0.0%) were significantly higher in the long group. Patients in the long group were also more likely to develop DVT (2.7% vs. 0.3%), and be readmitted to the hospital (28.8% vs. 20.7%).

Following covariable adjustment, long nails remained associated with a higher odds of fracture-related AE (5.11, 1.96–13.33) compared to short nails. We found no association between the adjusted odds of readmission and nail length (1.00, 0.52–1.94).

Our analyses revealed that trochanteric fracture patients managed with long IMN nails may have a higher odds of fracture-related AE compared to short nails. Future research is required to validate these findings with larger event rates, and further optimize IMN for trochanteric fracture patients.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 12 - 12
2 May 2024
Selim A Al-Hadithy N Diab N Ahmed A Kader KA Hegazy M Abdelazeem H Barakat A
Full Access

Lag screw cut-out is a serious complication of dynamic hip screw fixation in trochanteric hip fractures. Lag screw position is recognised as a crucial factor influencing the occurrence of lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesize that it could enhance the reliability of predicting lag screw cut-out in these injuries.

A retrospective study of hip fracture cases was conducted from January 2018 to July 2022. A total of 109 patients were eligible for the final analysis. The modified TAD was measured in millimetres, based on the sum of the traditional TAD in the lateral view and the net value of two distances in the anteroposterior (AP) view. The first distance is from the lag screw tip to the opposite point on the femoral head along the lag screw axis, while the second distance is from that point to the femoral head apex. The first distance is a positive value, whereas the second distance is positive if the lag screw is superior and negative if it is inferior. Receiver operating characteristic (ROC) curve analysis was used to assess the reliability of various parameters for evaluating the lag screw position within the femoral head.

Factors such as reduction quality, fracture pattern according to the AO/OTA classification, TAD, Calcar-Referenced TAD, Axis Blade Angle, Parker’s ratio in the AP view, Cleveland Zone 1, and modified TAD were statistically associated with lag screw cut-out. Among the tested parameters, the novel parameter exhibited 90.1% sensitivity and 90.9% specificity for predicting lag screw cut-out at a cut-off value of 25 mm, with a p-value < 0.001.

The modified TAD demonstrated the highest reliability in predicting lag screw cut-out. A value of 25 mm may potentially reduce the risk of lag screw cut-out in trochanteric hip fractures.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans.

Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively.

Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT.

The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings.


Displaced acetabular fractures in the older patient present significant treatment challenges. There is evidence the morbidity and mortality associated is similar to the fractured neck of femur cohort. Despite growing literature, there remains significant controversy regarding treatment algorithms; varying between conservative management, to fracture fixation and finally surgical fixation and simultaneous THA to allow immediate full weight bearing.

£250k NIHR, Research for Patient Benefit (Ref: PB-PG-0815-20054). Trial ethical approval (17/EE/0271). After national consultation, 3 arms included; conservative management, fracture fixation and simultaneous fracture fixation with THA. Statistical analysis required minimum 12 patients/3 arms to show feasibility, with an optimum 20/arm. Inclusion criteria; patients >60 years & displaced acetabular fracture. Exclusion criteria: open fracture, THA in situ, pre-injury immobility, polytrauma. Primary outcome measure - ability recruit & EQ-5D-5L at 6 months. Secondary outcome measures (9 months); OHS, Disability Rating Index, radiographs, perioperative physiological variables including surgery duration, blood loss, complications and health economics.

11 UK level 1 major trauma centres enrolled into the trial, commenced December 2017. Failure surgical equipoise was identified as an issue regarding recruitment. Full trial recruitment (60 patients) achieved; 333 patients screened. 66% male, median age 76 (range 63–93), median BMI 25 (range 18–37), 87% full mental capacity, 77% admitted from own home. 75% fall from standing height. 60% fractures; anterior column posterior hemi-transverse. Trial feasibility confirmed December 2020. Presented data- secondary outcomes that are statistically significant in improvement from baseline for only the fix and replace arm, with acceptable trial complications. Issues are highlighted with conservative management in this patient cohort.

Our unique RCT informs design and sample size calculation for a future RCT. It represents the first opportunity to understand the intricacies of these treatment modalities. This RCT provides clinicians with information on how best to provide management for this medically complex patient cohort.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 26 - 26
7 Jun 2023
Hoskins Z Kumar G Gangadharan R
Full Access

Periprosthetic femoral fractures are increasingly seen in recent years, adding considerable burden to the National Health Service. These require complex revision or fixation and prolonged post-operative care, with significant morbidity with associated costs. The purpose of this study was to assess whether the size of femoral cement mantle is associated with periprosthetic femoral fractures (PPF).

This retrospective study was carried out on a cohort of 49 patients (Fracture Group - FG) who previously had a revision procedure following a proximal PPF between 2010 and 2021. Inclusion criteria – all primary cemented total hip replacements (THR). Exclusion criteria – complex primary THR, any implant malposition that required early revision surgery or any pre-fracture stem loosening. The antero-posterior (AP) radiographs from this cohort of patients were assessed and compared to an age, sex, time since THR-matched control group of 49 patients without PPF (Control Group - CG). Distal cement mantle area (DCMA) was calculated on an AP radiograph of hip; the position of the femoral stem tip prior to fracture was also recorded: valgus, varus or central. Limitations: AP radiographs only. Statistical analyses were performed using Microsoft® Excel.

Chi-square test demonstrated statistically significant difference in DCMA between FG and CG. DCMA of 700 to 900 mm² appeared to be protective when compared to DCMA of 0 to 300 mm². Also, a valgus position observed in 23% in FG Vs 4 % in CG increased the risk, with a smaller area of DCMA.

This study demonstrates and recommends that a size of 700 – 900 mm² of the DCMA is protective against periprosthetic fractures, which are further influenced by the positioning of the distal stem tip. This could be due to the gradual decrease in the stiffness gradient from proximal to distal around the stem tip than steep changes, thereby decreasing possibility of a stress riser just distal to the cement mantle or restrictor. Further biomechanical research specific to this finding may be helpful to validate the observation, progressing to suggest a safe standardised surgical technique.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 55 - 55
2 May 2024
McCann C Ablett A Feng T Macaskill V Oliver W Keating J
Full Access

Subtrochanteric femoral fractures are a subset of hip fractures generally treated with cephalomedullary nail fixation\[1\]. Single lag screw devices are most commonly-used, but integrated dual screw constructs have become increasingly popular\[2,3\]. The aim of this study was to compare outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture.

Consecutive adult patients (18yrs) with subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Patients that underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022) were included. Medical records and radiographs were reviewed to identify complications of fixation. Cox regression analysis was used to determine the risk of mechanical failure and secondary outcomes by implant design. Multivariable regression models were used to identify predictors of mechanical failure.

The study included 622 patients, 354 in the GN group (median age 82yrs, 72% female) and 268 in the IN group (median age 82yrs, 69% female). The risk of any mechanical failure was increased two-fold in the GN group (HR 2.44 \[95%CI 1.13 to 5.26\]; _p=0.024_). Mechanical failure comprising screw cut-out (_p=0.032_), back-out (_p=0.032_) and nail breakage (_p=0.26_) was only observed in the GN group. Technical predictors of failure included varus >5° for cut-out (OR 19.98 \[2.06 to 193.88\]; _p=0.01_), TAD;25mm for back-out (8.96 \[1.36 to 58.86\]; p=0.022) and shortening 1cm for peri-implant fracture (7.81 \[2.92 to 20.91\]; _p=<0.001_).

Our results demonstrate that an intercalated screw construct is associated with a lower risk of mechanical failure compared with the a single lag screw device. Intercalated screw designs may reduce the risk of mechanical complications for patients with subtrochanteric femoral fractures.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 43 - 43
19 Aug 2024
Lustig S Batailler C
Full Access

The stem design in total hip arthroplasty (THA) is constantly evolving. The impact of the collar on the risk of periprosthetic fracture remains controversial. This study aimed to determine whether adding a collar to the femoral stem impacts the early periprosthetic fracture risk within 90 days of surgery.

This retrospective study included 1,623 patients who underwent primary total hip arthroplasty in a single orthopedic department between January 2010 and December 2020. The inclusion criteria were uncemented stem with or without a collar, in a primary intention, without previous hip surgery with a similar “corail like” design. The assessed data were demographic characteristics (age, gender, number of obese (BMI > 30)), single or dual mobility, the surgical approach, the early complication, particularly the periprosthetic femoral fractures. Of the 1,623 patients, 1,380 received a collared stem (85%), and 243 received a collarless stem (15%). A multivariate analysis was performed to determine the collar's effect on the risk of early periprosthetic fracture (<90 days).

Nine (0.55%) early periprosthetic fractures were identified in the whole cohort. There were four fractures (1.65%) in the collarless stem group and five fractures (0.36%) in the collared stem group (p=0,005). One patient required revision surgery in the collared stem group, while two patients required revision surgery in the collarless stem group. The multinomial logistic regression model indicated a statistically significant lower (p<0.05) risk of early periprosthetic fracture within 90 days of surgery in the collared stems group. No other risk factor for early periprosthetic fractures has been identified.

Using collared stems in cementless THA protects early periprosthetic femoral fractures within 90 days of surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 19 - 19
7 Jun 2023
Ahmed M Tirimanna R Ahmed U Hussein S Syed H Malik-Tabassum K Edmondson M
Full Access

The incidence of hip fractures in the elderly is increasing. Minimally displaced and un-displaced hip fractures can be treated with either internal fixation or hemiarthroplasty. The aim was identifying the revision rate of internal fixation and hemiarthroplasty in patients 60 years or older with Garden I or II hip fractures and to identify risk factors associated with each method.

A retrospective analysis was conducted from 2 Major Trauma Centres and 9 Trauma Units between 01/01/2015 and 31/12/2020. Patients managed conservatively, treated with a total hip replacement and missing data were excluded from the study.

1273 patients were included of which 26.2% (n=334) had cannulated hip fixation (CHF), 19.4% (n=247) had a dynamic hip screw (DHS) and 54.7% (n=692) had a hemiarthroplasty. 66 patients in total (5.2%) required revision surgery. The revision rates for CHF, DHS and hemiarthroplasty were 14.4%, 4%, 1.2% (p<0.001) respectively. Failed fixation was the most common reason for revision with the incidence increasing by 7-fold in the CHF group [45.8% (n=23) vs. 33.3% (n=3) in DHS; p<0.01]. The risk factors identified for CHF revision were age >80 (p<0.05), female gender (p<0.05) and smoking (p<0.05). The average length of hospital stay was decreased when using CHF compared to DHS and hemiarthroplasty (12.6 days vs 14.9 days vs 18.1 days respectively, p<0.001) and the 1 year mortality rate for CHF, DHS and hemiarthroplasty was 2.5%, 2% and 9% respectively.

Fixation methods for Garden I and II hip fractures in elderly patients are associated with a higher revision rate than hemiarthroplasty. CHF has the highest revision rate at 14.4% followed by DHS and hemiarthroplasty. Female patients, patients over the age of 80 and patients with poor bone quality are considered high risk for fixation failure with CHF. When considering a fixation method in such patients, DHS is more robust than a screw construct, followed by hemiarthroplasty.


Full Access

Osteoporosis can cause significant disability and cost to health services globally. We aim to compare risk fractures for both osteoporosis and fractures at the L1-L4 vertebrae (LV) and the neck of femurs (NOFs) in patients referred for DEXA scan in the North-West of England.

Data was obtained from 31546 patients referred for DEXA scan in the North-West of England between 2004 and 2011. Demographic data was retrospectively analysed using STATA, utilising chi-squared and t-tests. Logistical models were used to report odds ratios for risk factors included in the FRAX tool looking for differences between osteoporosis and fracture risk at the LV and NOFs.

In a study involving 2530 cases of LV fractures and 1363 of NOF fractures, age was significantly linked to fractures and osteoporosis at both sites, with a higher risk of osteoporosis at NOFs compared to LV. Height provided protection against fractures and osteoporosis at both sites, with a more pronounced protective effect against osteoporosis at NOFs. Weight was more protective for NOF fractures, while smoking increased osteoporosis risk with no site-specific difference. Steroids were unexpectedly protective for fractures at both sites, with no significant difference, while alcohol consumption was protective against osteoporosis at both sites and associated with increased LV fracture risk. Rheumatoid arthritis increased osteoporosis risk in NOFs and implied a higher fracture risk, though not statistically significant compared to LV. Results summarised in Table 1.

Our study reveals that established osteoporosis and fracture risk factors impact distinct bony sites differently. Age and rheumatoid arthritis increase osteoporosis risk more at NOFs than LV, while height and steroids provide greater protection at NOFs. Height significantly protects LV fractures, with alcohol predicting them. Further research is needed to explore risk factors’ impact on additional bony sites and understand the observed differences’ pathophysiology.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 54 - 54
23 Jun 2023
Shaath MK Yawman J Anderson T Avilucea F Langford J Munro M Haidukewych GJ
Full Access

Intertrochanteric fractures are common, accounting for nearly 30% of all fracture related admissions. Some have suggested that these fractures should be treated in community hospitals so as not to tax the resources of Level One trauma centers. Since many factors predictive of fixation failure are related to technical aspects of the surgery, the purpose of this study was to compare radiographic parameters after fixation comparing trauma fellowship trained surgeons to non-fellowship trained community surgeons to see if these fractures can be treated successfully in either setting.

Using our hospital system's trauma database, we identified 100 consecutive patients treated with cephalomedullary nails by traumatologists, and 100 consecutive patients treated by community surgeons. Quality of reduction, neck shaft angle (NSA), tip-to apex distance (TAD) were compared.

The mean TAD for the trauma group was 10mm compared to 21mm for the community group (p<0.001). The mean postoperative NSA for the trauma group was 133 degrees compared to 127 degrees for the community group (p<0.001). The mean difference in the NSA of the fractured side compared to the normal hip was 2.5 degrees of valgus in the trauma group compared to 5 degrees of varus for the community group (p<0.001). There were 93 good reductions in the trauma group compared to 19 in the community group (p<0.001). There were no poor reductions in the trauma group and 49 poor reductions in the community group (p<0.001).

Fellowship trained traumatologists achieved significantly more accurate reductions and implant placement during cephalomedullary nailing of intertrochanteric hip fractures.