Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 44 - 44
4 Apr 2023
Knopp B Harris M
Full Access

Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement. Patients treated with closed reduction were reduced from a mean displacement of 29.26±36.18% at an angulation of 22.67±16.57 degrees to 7.88±9.07% displacement and 3.89±6.68 degrees angulation post-reduction. Patients developing complications including a loss of reduction or refracture were found to have post-operative radiographs with a lower percent displacement (0.50±1.12) than those not developing complications (8.65±9.21)(p=0.0580). Post-reduction angulation (p=1.000), average reduction in angulation (p=1.000) and average reduction in displacement percent(p=0.2102) were not significantly associated with development of complications. Percent displacement of radial shafts was seen to be the most important metric to monitor in post-operative radiographs for patients undergoing closed reduction of a forearm fracture. We theorize a slight displacement provides greater surface area for osteoblastic expansion and callus formation leading to a decreased risk of refracture or loss of reduction. While our sample size precludes our ability to measure the ideal amount of post-reduction displacement for optimal healing, our results demonstrate that some degree of shaft displacement is required for optimal healing conditions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 45 - 45
4 Apr 2023
Knopp B Harris M
Full Access

This study was conducted to investigate the characteristics, complications, radiologic features and clinical course of patients undergoing reduction of forearm fractures in order to better inform patient prognosis and postoperative management. We conducted a retrospective cohort study of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. A preoperative radiological assessment and chart review was performed. Percent fracture displacement, location, orientation, comonution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement. Angle of angulation and percent fracture displacement were calculated by averaging AP and lateral radiograph measurements. 80 cases, averaging 13.5±8.3 years, were identified as having a complete fracture of the radius and/or ulna with 69 receiving closed reduction and 11 receiving fixation via an intramedullary device or percutaneous pinning. Eight patients (10%) experienced complications with four resulting in a refracture and four resulting in significant loss of reduction (LOR) without refracture. Fractures in the proximal ⅔s of the radius were associated with a significant increase in complications compared to fractures in the distal ⅓ of the radius (31.6% vs 3.4%) (P=.000428). Likewise, a higher percent fracture displacement was associated with a decreased risk of complications (28.7% vs 5.9% displacement)(P=0.0403). No elevated risk of complications was found based on fracture orientation, angulation, fracture line visibility, forearm bone(s) fractured, sex, age or arm affected. Our result highlights radius fracture location and percent fracture displacement as markers with prognostic value following forearm fracture. These measurements are simply calculated via pre-reduction radiographs, providing an efficient method of informing risk of complications following forearm fracture


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 29 - 29
1 Apr 2012
Bell S McLaughlin D Huntley J
Full Access

Forearm fractures are a common paediatric injury. This study was aimed to describe the epidemiological of paediatric forearm fractures in the urban population of Glasgow. We reviewed of all the forearm fracture treated by the orthopaedic service in Yorkhill Children's Hospital in 2008. Datum gathered from case notes and radiographs using the prospective orthopaedic database to identify patients with forearm fractures. The age, sex, side and type of fracture, the timing and mechanism of the injury and treatment were documented for the 436 fractures. Census data were used to derive absolute age-specific incidences. Distinction was made between torus and other types of fractures. Torus fractures require no specific orthopaedic treatment and were segregated out. For the remaining 314 fractures, the age and sex distribution, seasonal variation of fractures and treatments for each type of fracture were examined. The incidence of forearm fractures in our population is 411 fractures per 100,000 population per year. An increased number of fractures occurred during the months of May and August. A fall from less than one metre was the commonest mechanism of injury, sporting injuries were the second commonest with football the most common sport associated. This study identifies some features which are in good agreement with studies from elsewhere in Britain, such as incidence and seasonality. However, there are also interesting differences – such as the Glasgow peak incidence for forearm fractures being at age 8, with a marked decline by 12 years. Furthermore, our findings have been extended to consideration of type of intervention, and likelihood of successful treatment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 34 - 34
1 Aug 2013
Fraser-Moodie J Bell S Huntley J
Full Access

Introduction. Two randomised trials concluded cast type (above or below elbow) makes no significant difference in the re-displacement rate of paediatric forearm fractures involving the distal third of the radius. This has not, however, led to the universal use of below elbow casts. In particular we noted one trial reported significant re-displacement in 40% or more of cases, which was much higher than we would expect. To review the radiological outcomes and need for re-manipulation of paediatric distal forearm fractures treated with closed manipulation under anaesthesia in our institution, in part for subsequent comparison with published results. All forearm fractures treated at a specialist children's hospital in one year were reviewed retrospectively. Based on the methodology of one trial, we included all fractures involving the distal third of the radius, with or without an ulna fracture, which underwent closed manipulation. Outcomes were radiological alignment using existing radiographs and need for re-manipulation. Cast type was at the discretion of the treating surgeon. The radiological criteria for re-displacement were based on published methodology. 79 children underwent manipulation, 71 receiving above elbow casts and 8 below elbow casts. Radiologically 21% of injuries treated in an above elbow cast re-displaced (15/71) compared to 38% of those in below elbow plasters (3/8). In 2 cases the re-displacement was treated with re-manipulation. The preference in our institution was clearly for above elbow casts in this injury pattern. The small number of below elbow casts in our series limits any comparisons. Our rate of re-displacement using above elbow casts was half that of one of the published studies, so the existing literature is not consistent with our experience


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 9 - 9
1 Jun 2012
Frame MC Huntley JS
Full Access

3D printing an additive manufacturing technique, allowing for rapid prototyping in many industries. To date, medical applications have generally been within a research or industry environment, as the costs (expertise, software and equipment) have been prohibitive. We have established a means by which 3D printing of bones can be achieved quickly, cost-effectively and accurately from standard computer tomography (CT) digital imaging and communications in medicine (DICOM) data. CT DICOM data of a malunited forearm fracture were manipulated using open-source software (no cost) and a 3D model was produced by selective-laser-sintering. The entire process took 7 days (total cost £77). This process and the resultant model were then assessed for overall accuracy. This sequential methodology provides ready and economical access to a technology that is valuable for preoperative templating/rehearsal in complex 3D reconstructive cases


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 13 - 13
1 Apr 2014
Shields D Marsh M Aldridge S Williams J
Full Access

The management of displaced forearm diaphyseal fractures in adults is predominantly operative. Anatomical reduction is necessary to infer optimal motion and strength. The authors have observed an intraoperative technique where passive pronosupination is examined to assess quality of reduction as a surrogate marker for active movement. We aimed to assess the value of this technique, but intentionally malreducing a simulated diaphyseal fracture of a radius in a cadaveric model, and measuring the effect on pronosupination. A single cadaveric arm was prepared and pronation/supination was examined according to American Academy of Orthopaedic Surgeons guidance. A Henry approach was then performed and a transverse osteotomy achieved in the radial diaphysis. A volar locking plate was used to hold the radius in progressive amounts of translation and rotation, with pronosupaintion measured with a goniometer. The radius could be grossly malreduced with no effect on pronation and supination until the extremes of deformity. The forearm showed more tolerance with rotational malreduction than translation. Passive pronation was more sensitive for malreduction than supination. The use of passive pronosupination to assess quality of reduction is misleading