Aims. The impact of concomitant injuries in patients with proximal
Aims. Proximal
Aims. The incidence of atypical
Aims. Patients with proximal
Aims. The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing. Methods. A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point. Results. The mean mRUST score of ten at 24 weeks revealed a 91.9% sensitivity, 100% specificity, and 92.6% accuracy of predicting ultimate fracture healing. A cut-off point of 13 points revealed 41.9% sensitivity, 100% specificity, and 46.9% accuracy at the same time point. Conclusion. The mRUST score of ten points at 24 weeks can be used as a viable screening method with the highest sensitivity, specificity, and accuracy for healing of metadiaphyseal
Aims. Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical
Objectives. One commonly used rat fracture model for bone and mineral research
is a closed mid-shaft
The results of the treatment of 31 open
We evaluated the cost and consequences of proximal
Proximal
Aims. The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric
We have attempted to describe the epidemiology of
We performed a retrospective review of all patients
admitted to two large University Hospitals in the United Kingdom
over a 24-month period from January 2008 to January 2010 to identify
the incidence of atypical subtrochanteric and femoral shaft fractures
and their relationship to bisphosphonate treatment. Of the 3515 patients
with a fracture of the proximal femur, 156 fractures were in the
subtrochanteric region. There were 251 femoral shaft fractures.
The atypical fracture pattern was seen in 27 patients (7%) with
29 femoral shaft or subtrochanteric fractures. A total of 22 patients
with 24 atypical fractures were receiving bisphosphonate treatment at
the time of fracture. Prodromal pain was present in nine patients
(11 fractures); 11 (50%) of the patients on bisphosphonates suffered
12 spontaneous fractures, and healing of these fractures was delayed
in a number of patients. This large dual-centre review has established
the incidence of atypical
This retrospective cohort study was conducted to investigate whether operative treatment of patients with a pertrochanteric
We treated 108 patients with a pertrochanteric
Objectives. The use of two implants to manage concomitant ipsilateral femoral
shaft and proximal
We reviewed the clinical details and radiographs of 52 patients with ballistic fractures of the femur admitted to the International Committee of the Red Cross Hospital in Kenya (Lopiding), who had sustained injuries in neighbouring Sudan. In all cases there had been a significant delay in the initial surgery (>
24 hours), and all patients were managed without stabilisation of the fracture by internal or external fixation. Of the 52 patients, three required an amputation for persisting infection of the fracture site despite multiple debridements. A further patient was treated by an excision arthroplasty of the hip, but this was carried out at the initial operation as a part of the required debridement. All of the remaining 48 fractures healed. Four patients needed permanent shoe adaptation because of limb shortening of functional significance. Although we do not advocate delaying treatment or using traction instead of internal or external fixation, we have demonstrated that open
Little is known about the effect of haemorrhagic shock and resuscitation
on fracture healing. This study used a rabbit model with a femoral
osteotomy and fixation to examine this relationship. A total of 18 male New Zealand white rabbits underwent femoral
osteotomy with intramedullary fixation with ‘shock’ (n = 9) and
control (n = 9) groups. Shock was induced in the study group by
removal of 35% of the total blood volume 45 minutes before resuscitation
with blood and crystalloid. Fracture healing was monitored for eight weeks
using serum markers of healing and radiographs.Aims
Materials and Methods
Mortality rates following hip fracture are high. There are several scoring systems which aim to predict morbidity and mortality in hospital in-patients. The Nottingham Hip Fracture Score (NHFS) was devised to predict 30 day mortality following hip fracture. All patients with hip fractures admitted over a 6 month period were reviewed. The NHFS was calculated for each patient and any associations between patient factors, NHFS, and outcome were investigated.Introduction
Methods
We investigated a new intramedullary locking
nail that allows the distal interlocking screws to be locked to
the nail. We compared fixation using this new implant with fixation
using either a conventional nail or a locking plate in a laboratory
simulation of an osteoporotic fracture of the distal femur. A total
of 15 human cadaver femora were used to simulate an AO 33-A3 fracture
pattern. Paired specimens compared fixation using either a locking
or non-locking retrograde nail, and using either a locking retrograde
nail or a locking plate. The constructs underwent cyclical loading
to simulate single-leg stance up to 125 000 cycles. Axial and torsional
stiffness and displacement, cycles to failure and modes of failure
were recorded for each specimen. When compared with locking plate
constructs, locking nail constructs had significantly longer mean
fatigue life (75 800 cycles ( The new locking retrograde femoral nail showed better stiffness
and fatigue life than locking plates, and superior fatigue life
to non-locking nails, which may be advantageous in elderly patients. Cite this article: