Introduction. Accurate component placement in total hip arthroplasty (THA) improves post-operative stability and reduces wear and aseptic loosening. Methods for achieving accurate stem placement have not been as extensively studied as cup placement. Objectives. The purpose of this study is to determine how consistently
Appropriate femoral stem anteversion is an important factor in maintaining stability and maximizing the performance of the bearing after total hip replacement (THR). The anteversion of the native femoral neck has been shown to have a significant effect on the final anteversion of the stem, particularly with a uncemented femoral component. The aim of this study was to quantify the variation in native femoral neck anteversion in a population of patients requiring total hip replacement. Pre-operatively, 1215 patients received CT scans as part of their routine planning for THR. Within the 3D planning, each patient's native femoral neck anteversion, measured in relation to the posterior condyles of the knee, was determined. Patients were separated into eight groups based upon gender and age. Males and females were divided by those under 55 years of age, those aged 55 to 64, 65 to 74 and those 75 or older.Introduction
Methods
Appropriate prosthetic alignment is an important factor in maintaining stability and maximising the performance of the bearing after total hip replacement (THR). With a cementless component, the anteversion of the native femur has been shown to influence the anteversion of the prosthetic stem. However, the extent to which anteversion of a cementless stem can be adjusted from the native anteversion has seldom been reported. The aim of this study was to investigate the difference between native and stem anteversion with two different cementless stem designs. 116 patients had 3-dimensional templating as part of their routine planning for THR (Optimized Ortho, Sydney). 96 patients from 3 surgeons (AS, JB, SM) received a blade stem (TriFit TS, Corin, UK) through a posterior approach. 18 patients received a fully HA-coated stem (MetaFix, Corin, UK) through a posterior approach by a single surgeon (WB). The anteversion of the native femoral neck was measured from a 3D reconstruction of the proximal femur. All patients received a post-operative CT scan which was superimposed onto the pre-op CT scan. The difference between native and achieved stem anteversion was then measured. As surgeons had differing philosophies around target stem anteversion, the differences amongst surgeons were also investigated.Introduction
Method
Combined anteversion angle of acetabular component and femeral neck is an important factor for total hip arthroplasty (THA) as it may affect impingement and dislocation. Previous studies have collected data mainly from direct measurements of bone morphology or manual measurements from 2D or 3D radiolographic images. The purpose of this study was to electronically measure the version angles in native acetabulum and femur in matured normal Caucasion population using a novel virtual bone database and analysis environment named SOMA™. 221 CT scans from a skeletally mature, normal Caucasian population with an age range of 30–95 years old. The population included 135 males and 86 females. CT data was converted to virtual bones with cortical and cancellous boundaries using custom CT analytical sofware. (SOMA™ V.3.2) Auxillary reference frames were constructed and measurements were performed within the SOMA™ design environment. Acetabular Anteversion (AA) angle as defined by Murray1 was measured. The acetabular rim plane was constructed by selecting 3 bony land marks from pubis, ilium and ischium. A vector through acetabular center point and normal to the rim plane defined the plane for the AA measurement. The AA was defined as the angle of this plane relative to the frontal (Coronal) plane of the pelvis. The Femoral Neck Anteversion (FNA) angle was measured from the neck axis plane to the frontal (Coronal) plane as defined by the posterior condyles. The neck axis plane was constructed to pass through femoral neck axis perpendicular to the transverse plane. The combined anteversion angle was computed as the summation of acetabular and femoral anteversion angles. Student's t tests were performed to compare gender difference with an assumed 95% confidence level. The mean AA angle for total population was 25.8°, SD=7.95°. The mean AA for male was 24.8°, SD=5.93° and for female was 27.3°, SD=7.14°. P=0.009. The mean FNA angle for total population was 14.3°, SD=6.52°. The mean FNA for male was 13.5°, SD=7.97° and for female was 15.5°, SD=7.80°. P=0.058. The mean combined anteversion angle for total population was 40.1°, SD=10.76°. The mean combined anteversion angle for male was 38.3° SD=10.39 ° and for female was 42.8° SD=10.83 °. P=.0002. The plot of AA as a function of FNA shows weak correlation for both male and female. (Figure 1) The frequency distribution is shown in Figure 2. The results showed the both AA, FNA and combined anteversion angles were significantly smaller in male population than that in female population. The FNA angle of the cementless femoral stem can be smaller than with the natural femur, therefore a higher AA or higher posterior build up may be required for the acetabular component for optimal function of a THA.
Introduction. Osteogenesis imperfect (OI) is a geno- and phenotypically heterogeneous group of congenital collagen disorders characterized by fragility and microfractures resulting in long bone deformities. OI can lead to progressive femoral coxa vara from bone and muscular imbalance and continuous microfracture about the proximal femur. If left untreated, patients develop Trendelenburg gait, leg length discrepancy, further stress fracture and acute fracture at the apex of the deformity, impingement and hip joint degeneration. In the OI patient, femoral coxa vara cannot be treated in isolation and consideration must be given to protecting the whole bone with the primary goal of verticalization and improved biomechanical stability to allow early loading, safe standing, re-orientation of the physis and avoidance of untreated sequelae. Implant constructs should therefore be designed to accommodate and protect the whole bone. The normal paediatric femoral neck shaft angle (FNSA) ranges from 135 to 145 degrees. In OI the progressive pathomechanical changes result in FNSA of significantly less than 120 degrees and decreased Hilgenreiner epiphyseal angles (HEA). Proximal femoral valgus osteotomy is considered the standard surgical treatment for coxa vara and multiple surgical techniques have been described, each with their associated complications. In this paper we present the novel technique of controlling
Instability is the most common reason for revision after total hip arthroplasty (THA). Since THA requires arthrotomy of the hip and replacement with a femoral head that is smaller than the normal hip, instability following THA is always a potential concern. Many factors contribute to the development of instability after THA including: restoration of normal anatomy, implant design, component position, surgical approach and technique, and numerous patient related factors. Recently, the role of spinal mobility and deformity has been shown to have a significant effect on risk of dislocation after THA. The long held guidelines for component positioning or so called “safe zone” described by Lewinnek have also been questioned since most dislocations have been shown to occur in patients whose components are positioned within this “safe” range. In the early post-operative period, dislocation can occur prior to capsular and soft tissue healing if the patient exceeds their peri-operative range of motion limits. Closed reduction and abduction bracing for 6 weeks may allow for soft tissue healing and stabilization of the hip. It is important to try and identify the mechanism of dislocation since this can affect the technique of closed reduction, how the patient is braced following reduction and what may need to be addressed at the time of revision if dislocation recurs. Closed reduction and bracing may be effective in patients who have a previously well-functioning, stable THA who suffer a traumatic dislocation after the peri-operative period. Despite successful closed reduction, recurrent dislocation occurs in many patients and can be secondary to inadequate soft tissue healing, patient noncompliance or problems related to component positioning. Patients who incur more than 2 dislocations should be considered for revision surgery. Prior to revision surgery, an appropriate radiographic evaluation of the hip should be performed to identify any potential mechanical/kinematic issues that need to be addressed at the time of revision. Typically this involves plain radiographs, including a cross table lateral of the involved hip to assess acetabular version, but may also involve cross-sectional imaging to assess
Background. Despite the success of total hip arthroplasty (THA), there are still challenges including restoration of leg length, offset, and
Over the past several decades, cementless femoral fixation for primary total hip arthroplasties (THAs) has become more common in North America. It is estimated that nearly 90% of all primary THAs completed in the United States are cementless. In the Australian National Joint Replacement Registry, the use of cementless fixation has increased from 51.3% in 2003 to 63.3% in 2015. During the same time period, cemented fixation declined from 13.9% to 3.7%, but hybrid fixation was relatively stable at about 33%. This is likely related to the fact that multiple institutional and national registries have shown a higher rate of intra-operative periprosthetic femoral fractures with the use of cementless femoral components in certain patient populations. Those risk factors include patients greater than 65 years of age, female patients, and those with significant osteoporosis and Dorr C canals. However, it is important to note that not all cementless femoral components are similar. In fact, there is great variation in not only the geometry of cementless femoral components, but also in the type and extent of the biologic ingrowth surfaces. Each design has unique advantages and disadvantages. While some cementless femoral components are indicated for the general population, some are more specific and tailored to complex primary THAs (such as developmental dysplasia of the hip or post-traumatic arthritis with intra-operative concern for
Introduction. Cup positioning in total hip arthroplasty (THA) is an important variable for short and long term durability of any hip implant. This novel method utilises internal and external bony landmarks, and the transverse acetabular ligament for positioning the acetabular component. Methods. The cup is placed parallel and superior to the transverse ligament and inside the anterior wall notch of the true acetabulum, and then adjusted for
With the increasing use of 3D medical imaging, it is possible to analyze 3D patient anatomy to extract features, trends and population specific shape information. This is applied to the development of ‘standard implants’ targeted to specific population groups. INTRODUCTION. Human beings are diverse in their physical makeup while implants are often designed based on some key measurements taken from the literature or a limited sampling of patient data. The different implant sizes are often scaled versions of the ‘average’ implant, although in reality, the shape of anatomy changes as a function of the size of patient. The implant designs are often developed based on a certain demographic and ethnicity and then, simply applied to others, which can result in poor design fitment [1]. Today, with the increasing use of 3D medical imaging (e.g. CT or MRI), it is possible to analyze 3D patient anatomy to extract features, trends and population specific shape information. This can be applied to the development of new ‘standard implants’ targeted to a specific population group [2]. PATIENTS & METHODS. Our population analysis was performed by creating a Statistical Shape Model (SSM) [3] of the dataset. In this study, 40 full Chinese cadaver femurs and 100 full Caucasian cadaver femurs were segmented from CT scans using Mimics®. Two different SSMs, specific to each population, were built using in-house software tools. These SSMs were validated using leave-one-out experiments, and then analyzed and compared in order to enhance the two population shape differences. RESULTS. An SSM is typically represented by an average model and a few independent modes of variation that capture most of the inherent variations in the data. Based on these main modes of variations, the shape features, e.g. length, thickness, curvature neck angle and