Advertisement for orthosearch.org.uk
Results 1 - 20 of 140
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 709 - 715
1 Jun 2020
Abdelsamie KR Elhawary I Ali H Ali M EL-Shafie M Dominic Meek RM

Aims. Femoral revision component subsidence has been identified as predicting early failure in revision hip surgery. This comparative cohort study assessed the potential risk factors of subsidence in two commonly used femoral implant designs. Methods. A comparative cohort study was undertaken, analyzing a consecutive series of patients following revision total hip arthroplasties using either a tapered-modular (TM) fluted titanium or a porous-coated cylindrical modular (PCM) titanium femoral component, between April 2006 and May 2018. Clinical and radiological assessment was compared for both treatment cohorts. Risk factors for subsidence were assessed and compared. Results. In total, 65 TM and 35 PCM cases were included. At mean follow-up of seven years (1 to 13), subsidence was noted in both cohorts during the initial three months postoperatively (p < 0.001) then implants stabilized. Subsidence noted in 58.7% (38/65 cases) of the TM cohort (mean 2.3 mm, SD 3.5 mm) compared to 48.8% (17/35) of PCM cohort (mean 1.9 mm, SD 2.6 mm; p = 0.344). Subsidence of PCM cohort were significantly associated with extended trochanteric osteotomy (ETO) (p < 0.041). Although the ETO was used less frequently in PCM stem cohort (7/35), subsidence was noted in 85% (6/7) of them. Significant improvement of the final mean Oxford Hip Score (OHS) was reported in both treatment groups (p < 0.001). Conclusion. Both modular TM and PCM revision femoral components subsided within the femur. TM implants subsided more frequently than PCM components if the femur was intact but with no difference in clinical outcomes. However, if an ETO is performed then a PCM component will subside significantly more and suggests the use of a TM implant may be advisable. Cite this article: Bone Joint J 2020;102-B(6):709–715


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 34 - 34
1 May 2018
Woodbridge A Wilson M Whitehouse S Hubble M
Full Access

Cement-in-cement femoral revision is a proven technique in revision total hip arthroplasty, with excellent results when using standard sized Exeter stems. The Exeter 44/00 125 mm short revision stem was introduced in 2004 to facilitate cement-in-cement revision. The stem is 25mm shorter and has a slimmer body to allow greater flexibility to adjust depth of insertion and version of the stem. However, it is not known if this change in stem length and size effects its longer term performance. We therefore reviewed the clinical outcome and survival of the Exeter 44/00 short stem used for cement-in-cement revision in our unit, with a minimum of 5 years follow up. 166 cases were performed between 2004 and 2010. 103 hips were available for 5 year clinical and radiological follow up, with 91 hips surviving to final review in 2017. At 5 years, 43 hips had died, 13 were revised and 7 were too frail to attend clinical review. The fate of all 166 hips were known and included in the survival analysis. Median clinical scores improved significantly. Sixteen hips required re-revision (infection 6, loose cup 3, periprosthetic fracture 3, instability 2, stem fracture with chronic infection 1 and pain 1). Kaplan-meier survival analysis revealed 100% survival for aseptic loosening, 96.8% survival for stem failure and 88.9% survival for all causes. This is the largest series with the longest follow up of the Exeter 44/00 short revision stem. The stem performs equally well as standard Exeter stems with regards to aseptic loosening. The single stem fracture occurred secondary to bone loss in chronic infection, highlighting the importance of providing adequate proximal support for the stem. Periprosthetic fracture occurred in 2.4% of this series of revision cases. Larger registry-based studies may provide additional information on the performance of this stem


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1215 - 1221
1 Jul 2021
Kennedy JW Ng NYB Young D Kane N Marsh AG Meek RMD

Aims

Cement-in-cement revision of the femoral component represents a widely practised technique for a variety of indications in revision total hip arthroplasty. In this study, we compare the clinical and radiological outcomes of two polished tapered femoral components.

Methods

From our prospectively collated database, we identified all patients undergoing cement-in-cement revision from January 2005 to January 2013 who had a minimum of two years' follow-up. All cases were performed by the senior author using either an Exeter short revision stem or the C-Stem AMT high offset No. 1 prosthesis. Patients were followed-up annually with clinical and radiological assessment.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 5 - 5
1 Jan 2018
Haidukewych G Shekailo P Yoon R
Full Access

There is a paucity of available literature to guide the surgeon treating postoperative fractures of the greater trochanter after femoral component revision. Between 2009 and 2016, 133 patients underwent femoral component revision by the senior author utilizing a modular tapered fluted titanium stem. 17 patients died or had inadequate follow-up. Therefore, 116 patients were included in the final analysis. There were 58 males and 58 females with a mean age of 64 (range 23 to 91 years old). Clinical and radiographic data were analyzed for postoperative greater trochanteric fracture (GTfx). Mean clinical follow up was 21 months (range 3 to 77 mos). Age, BMI, preoperative diagnosis, comorbidities, reason for revision, use of Extended Trochanteric Osteotomy (ETO), fixation method of ETO, presence of prior hardware, post-operative trauma (falls), femoral component size and offset, change in leg length were analyzed to determine potential risk factors for postoperative GT fracture. There were 7 postoperative greater trochanteric fractures in 7 patients (6%). Of these, 1 occurred as a result of a postoperative fall, 1 occurred after dislocation, and 1 occurred after a fall with a subsequent dislocation. The mean time to diagnosis of the fracture was 10.7 weeks postoperatively (range one day to 37.4 weeks). 52 of 116 patients had their revision performed through an ETO. Of those, 6 had a postoperative fracture of the GT. The use of an ETO significantly increased the likelihood of postoperative GT fx (p=0.035). Regarding femoral component size, use of a longer proximal body (+10 or greater) was associated with an increased risk of postoperative GT fx (p=0.07). Two fractures were minimally (<1cm) or non-displaced and were treated non-operatively. Of these fractures, 1 united. The other fracture further displaced and resulted in recurrent instability. This was treated with excision of the fragment and a constrained liner. 5 fractures were displaced and were treated with ORIF. 3 were fixed with a cable grip device, 1 was plated, and 1 was treated with a cable grip device and a constrained liner. Of those treated with some form of ORIF, all 5 healed. Of those that underwent surgical fixation initially, 3 reported residual trochanteric pain and 1 patient had their hardware removed (trochanteric claw). 2 of these patients have a residual limp and require a cane for use as a gait aid. The patient treated non-surgically required a cane as did the patient that failed non-surgical treatment. Post-operative greater trochanteric fractures are a rare complication of femoral component revision. The use of an ETO significantly increased the rate of post of GTfx. The mean time to diagnosis of was 11 weeks. Displaced fractures of the greater trochanter treated with ORIF all healed, both cable grip devices and plates were effective. Residual limp requiring gait aids and residual trochanteric pain were common outcomes after fixation of these fractures despite successful union


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 52 - 52
1 Nov 2015
Marsh A Kennedy I Nisar A Patil S Meek R
Full Access

Introduction. Cement in cement revision with preservation of the original cement mantle has become an attractive and commonly practised technique in revision hip surgery. Since introducing this technique to our unit we have used two types of polished tapered stem. We report the clinical and radiological outcomes for cement in cement femoral revisions performed using these prostheses. Materials and Methods. All patients who underwent femoral cement in cement revision with a smooth tapered stem between 2005 –2013 were assessed. Data collected included indication for revision surgery and components used. All patients were followed up annually. Outcomes recorded were radiographic analysis, clinical outcome scores (Oxford Hip Score, WOMAC and SF-12) and complications, including requirement for further revision surgery. Median follow-up was 5 years (range 1 – 8 years). 116 revision procedures utilising cement in cement femoral revision were performed in the 8 year study period (68 females, 48 males, and mean age of 69 years). The femoral component was a C-stem AMT (Depuy) in 59 cases and Exeter stem (Stryker) in 57 cases. Results. Radiographic analysis demonstrated no progressive radiolucencies around the femoral component in any patient and no evidence of stem loosening at most recent review. Median Oxford Hip Score increased from 15 to 32, WOMAC from 22 to 38, and SF-12 from 25 to 32. Two patients had a further revision procedure for recurrent dislocation and 1 patient for infection. Two patients had a peri-prosthetic fracture at 4 years following initial revision surgery. There were 2 femoral stem fractures (occurring at 3 and 4 years post revision, both occurring in Exeter stems). Conclusion. Our results report cement in cement revision of the femoral component provides promising mid-term radiographic and clinical results. No femoral stems required revision for aseptic loosening. Stem fracture however occurred in 2 cases suggesting stem design is crucial for this technique


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 7 - 7
1 Aug 2021
Kennedy I Ng N Young D Kane N Marsh A Meek D
Full Access

Cement-in-cement revision of the femoral component represents a widely practiced technique for a variety of indications. In this study we compare the clinical and radiological outcomes of two polished tapered stems.

From our prospectively collated database we identified all patients undergoing cement-in-cement revision from January 2005 – 2013 who had a minimum of two years follow-up. All cases were performed by the senior author using either an Exeter short revision stem or the C-stem AMT high offset No 1. Patients were followed-up annually with clinical and radiological assessment.

Ninety-seven patients matched the inclusion criteria. There were 50 Exeter and 47 C-stem AMT components. There were no significant differences between the patient demographics in either group. Mean follow-up was 9.7 years. A significant improvement in OHS, WOMAC and SF-12 scores was observed in both cohorts. Leg lengths were significantly shorter in the Exeter group, with a mean of -4mm in this cohort compared to 0mm in the C-stem AMT group. One patient in the Exeter group had early evidence of radiological loosening. In total, 16 patients (15%) underwent further revision of the femoral component (seven in the C-stem AMT group and nine in the Exeter group). No femoral components were revised for aseptic loosening. There were two cases of femoral component fracture in the Exeter group.

Our series shows promising long-term outcomes for the cement-in-cement revision technique using either the Exeter or C-stem AMT components. These results demonstrate that cement-in-cement revision using a double or triple taper-slip design is a safe and reliable technique when used for the correct indications.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 39 - 39
1 Jun 2016
Sandiford N Wilson M Hubble M Jameson S Howell J
Full Access

Introduction. Revision of well cemented femoral components in revision THA can be technically challenging and time consuming. The cement in cement (CiC) technique addresses these issues. Results of femoral components which have undergone multiple CiC revisions have not previously been reported. Objective. We present the clinical and radiological results of femoral components which have undergone multiple CiC revisions with a minimum follow up of 5 years. Methods. Forty nine revision procedures were performed in 24 patients (10 males, 14 females). Seven patients died due to unrelated causes. The outcomes of all patients are known. Functional assessment were performed using the original Oxford Hip Score (OHS), Harris Hip Score (HHS) and the Merle d'Aubigne Postel(MDP) score. Statistical analysis was performed using the unpaired student's t-test. The level of significance was set at p=0.05. Radiographs were reviewed for signs of loosening at each visit. Results. The mean age was 67.5 years. Average duration of follow up was 81.7 months (range 24–240 months). Forty one revision procedures were performed for acetabular revision (the stem was removed to facilitate exposure), 6 were for revision of both components and 2 were isolated stem revisions. Each patient had undergone an average of 2 revision procedures. Four revisions were performed for infection. Mean preoperative Harris, Oxford and Merle D'Aubigne Postel scores were 38 (Range 3–44), 43 (Range 27–56) and 7 (Range 3–13) respectively. Average post-operative Harris, Oxford and Merle D'Aubigne Postel scores were 68 (Range 45–70) (p=0.0199), 31 (Range 12–56) (p=0.0397) and 13 (Range 4–18)(p=0.0423) respectively. There were no signs of loosening follow up. Conclusion. Cement in cement femoral revision is an effective technique for patients requiring multiple revisions of a well fixed cemented stem. It is associated with pain relief and significant functional improvement in the medium term


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 199 - 203
1 Feb 2017
Sandiford NA Jameson SS Wilson MJ Hubble MJW Timperley AJ Howell JR

Aims

We present the clinical and radiological results at a minimum follow-up of five years for patients who have undergone multiple cement-in-cement revisions of their femoral component at revision total hip arthroplasty (THA).

Patients and Methods

We reviewed the outcome on a consecutive series of 24 patients (10 men, 14 women) (51 procedures) who underwent more than one cement-in-cement revision of the same femoral component. The mean age of the patients was 67.5 years (36 to 92) at final follow-up.

Function was assessed using the original Harris hip score (HHS), Oxford Hip Score (OHS) and the Merle D’Aubigné Postel score (MDP).


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1039 - 1046
1 Sep 2022
Özdemir E Kuijpers MFL Visser J Schreurs BW Rijnen WHC

Aims. The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique. Methods. We updated the outcomes of our previous study, based on 208 consecutive revisions using IBG and the X-change femoral revision system in combination with a cemented polished stem, performed in our tertiary care institute between 1991 and 2007. Kaplan-Meier survival analyses were used to determine the survival rate of the revisions with endpoint revision for any reason and aseptic loosening. Secondary outcomes were radiological loosening and patient-reported outcome measures. Results. Mean age at revision total hip arthroplasty (THA) was 64.9 years (30 to 86). The most prevalent diagnosis for the femoral revision was aseptic loosening. At review in May 2021, 81 patients (85 hips) were still alive and 118 patients (120 hips; 58%) had died. Three patients (3 hips; 1%) were lost to follow-up at 11, 15, and 16 years after surgery, respectively. Data of all deceased and lost patients were included until final follow-up. The mean follow-up was 13.4 years (0 to 28). During the follow-up, 22 re-revisions were performed. The most common reason for re-revision was infection (n = 12; 54%). The survival with endpoint re-revision for any reason was 86% (95% confidence interval (CI) 79 to 91) at 20 years and 74% (95% CI 43 to 89) at 25 years after surgery. The survival for endpoint re-revision for aseptic loosening was 97% (95% CI 91 to 99) after both 20 and 25 years. Conclusion. We conclude that femoral IBG is a valuable technique that can reconstitute femoral bone loss in the long term. After 25 years of follow-up, few re-revisions for aseptic loosening were required. Also, the overall revision rate is very acceptable at a long follow-up. This technique is especially attractive for younger patients facing femoral revisions with extensive bone loss. Cite this article: Bone Joint J 2022;104-B(9):1039–1046


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 19 - 19
2 May 2024
Shaarani S Moriarty P Vles G Haddad F Konan S
Full Access

We had previously reported on early outcomes on a new fluted, titanium, monobloc stem with a three degree taper that has been designed for challenging femoral reconstruction in the setting of extensive bone loss. The aim of this study was to report its mid-term clinical and radiographic outcomes. This is a retrospective review of prospectively collected data carried out at a single institution between Jan 2017 and Dec 2019. 85 femoral revisions were performed using a new tapered, fluted, titanium, monobloc (TFTM) revision stem. Complications, clinical and radiographic data were obtained from medical records and a locally maintained database. Clinical outcomes were assessed using the Oxford Hip Score (OHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). All post-operative radiographs were analysed for subsidence, osteolysis and femoral cortical bone remodelling. Mean follow-up was 60 months (range 28–84 months). Subsidence of 1.2 mm was noted in one patient. No cases of clinically significant subsidence (10 mm) were observed. At final follow-up, a statistically significant improvement was noted in functional outcome scores. The mean OHS preoperatively and at final follow-up were 24 (SD 13) and 42 (SD15). p = 0.04 mean difference 18 (95% CI 15–22). The mean WOMAC scores preoperatively and at final follow-up were 62 (SD23) and 88 (SD7) respectively (p < 0.001, mean difference 26; 95% CI 21–34). No stem fractures were noted within the follow-up period. Two patients had revision of the stem's one for infection and another for persistent pain. Positive mid-term clinical and radiological outcomes have been observed with this tapered, fluted, titanium, monobloc stem. Based on these results, this implant may be considered as a viable option in the majority of uncemented femoral revisions


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 34 - 34
1 Aug 2021
Ramavath A Leong J Siney P Kay P Divecha H Board T
Full Access

Principles of bone preservation and restoration of biomechanical alignment should be followed during revision total hip arthroplasty (THA). Where possible, conservative femoral revision techniques and even reconstructive de-escalation involving using primary stems should be considered. This study aims to investigate the outcome of patients who have undergone conservative femoral revision THA in our Institution. We retrospectively identified patients from our Institution's revision arthroplasty database who had cemented, or un-cemented primary stems implanted during revision THA of a previous stemmed femoral implant. Our primary outcome measure was all-cause re-revision THA with a secondary outcome measure of improvement in Oxford hip score (OHS). Radiographic evidence of stem loosening and post-op complications were recorded. Between 02/12/2014 to 12/12/2019, there were 226 patients identified with a mean follow up of 2 years (1–5 years). The majority of cases were represented by Paprosky type 1 (63%) and type 2 (25%) femoral defects. There were 45 patients (20%) who underwent impaction bone grafting (IBG) and 43 patients (19%) who had a cement in cement (CinC) femoral revision and cemented primary stem in 137 (60%), 1 uncemented stem with no IBG or CinC revision. Kaplan Meier survival for all-cause re-revision THA was 93.7% (95% CI: 88.3 – 100) at 3 years. The reasons for re-revision included 4 periprosthetic fractures, 4 dislocations, 1 deep infection, 1 loosening of femoral component and 1 loosening of acetabular component. Pre- and post-operative OHS scores were available in 137 hips (60%) with a mean improvement of 13. Radiographic review revealed 7% of cases with evidence of loosening in 1 or more Gruen zones. Our early results support the use of conservative femoral revision THA techniques where appropriate, with low complication and re-revision rates. Revisions using primary femoral components, where appropriate, should be considered in surgical planning to avoid unnecessary reconstructive escalation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 11 - 11
23 Jun 2023
Lombardi AV Alexander JS Berend KR Houserman DJ Adams JB Crawford DA
Full Access

Previous studies have reported excellent results with tapered, titanium alloy, porous plasma-sprayed components in patients undergoing uncemented primary total hip arthroplasty (THA). The purpose of this study was to examine survival and clinical results at minimum 25-year follow-up. We reviewed all patients who underwent primary THA at our center through 1995 with a specific femoral component, the Mallory-Head Porous (MHP; Zimmer Biomet, Warsaw, IN). This device, marketed in the U.S. until December 2021, was essentially unchanged since its 1984 introduction, except the porous coating was continued circumferentially along the lateral aspect in 1987, a hydroxyapatite-coated option was offered in 1988, and an offset option was added in 1999 after the study period. Three hundred thirty-two patients (396 THA) had a minimum of 25-year follow-up. Mean age at surgery was 47.6 years (range, 21–70 years). Mean follow-up in non-failed patients was 28.7 years (range, 25 to 37 years). There were 31 femoral revisions (7.8%): 9 infection, 3 failure of ingrowth, 5 aseptic loosening, 8 osteolysis revised well-fixed, 2 periprosthetic fracture, 2 polyethylene wear with trochanteric avulsion, 1 component breakage, and 1 malalignment well-fixed. Kaplan-Meier survival with endpoint of stem revision for all causes was 94.8% (95% CI: ±0.9%) at 36.7 years, and survival with endpoint of aseptic loosening/failure of ingrowth was 98.7% (95% CI: ±0.5) at 36.7 years. Harris hip scores improved significantly from 43 preoperatively to 76 most recently. This tapered, titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of femoral component revision for any reason or aseptic loosening/failure of ingrowth


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims. Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. Methods. We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases. Results. Seven patients (7.9%) required further revision for infection. Ten patients died of causes unrelated to their infection before their two-year review (mean 5.9 months; 0.9 to 18.6). One patient was lost to follow-up at five months after surgery, and two patients died of causes unrelated to their hip shortly after their two-year review was due without attending. Of the remaining patients, 69 remained infection-free at final review. Radiological review confirms the mechanical success of the procedure as previously described in aseptic revision, and postoperative Oxford Hip Scores suggest satisfactory functional outcomes. Conclusion. In conclusion, we found that retaining a well-fixed femoral cement mantle in the presence of infection and undertaking a cement-in-cement revision was successful in 82 of the patients (92.1%) in our series of 89, both in terms of eradication of infection and component fixation. These results are comparable to other more invasive techniques and offer significant potential benefits to the patient. Cite this article: Bone Joint J 2022;104-B(2):212–220


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims. This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. Methods. We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018. Results. Of the surviving 30 patients (34 THAs), there were four periprosthetic fractures: one underwent femoral revision after 21 years, two had surgical fixation as the stem was deemed stable, and one was treated nonoperatively due to the patient’s comorbidities. The periprosthetic fracture patients showed radiological evidence of change in bone stock around the femoral stem, which may have contributed to the fractures; this was reflected in change of the canal flare index at the proximal femur. Two patients (two hips) were lost to follow-up. Using aseptic loosening as the endpoint, 16 patients (18 hips; 48%) needed acetabular revision. None of the femoral components were revised for aseptic loosening, demonstrating 100% survival. The estimate of the cumulative proportion surviving for revisions due to any cause was 0.97 (standard error 0.03). Conclusion. In young patients with high demands, the Furlong HAC-coated femoral component gives excellent long-term results. Cite this article: Bone Jt Open 2024;5(4):286–293


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 4 - 4
23 Jun 2023
Gross A Safir O Kuzyk P
Full Access

Pelvic discontinuity is a separation through the acetabulum with the ilium displacing superiorly and the ischium/pubis displacing inferiorly. This is a biomechanically challenging environment with a high rate of failure for standard acetabular components. The cup-cage reconstruction involves the use of a highly porous metal cup to achieve biological bone ingrowth on both sides of the pelvic discontinuity and an ilioischial cage to provide secure fixation across the discontinuity and bring the articulating hip center to the correct level. The purpose of this study was to report long term follow up of the use of the cup-cage to treat pelvic discontinuity. All hip revision procedures between January 2003 and January 2022 where a cup-cage was used for a hip with a pelvic discontinuity were included in this retrospective review. All patients received a Trabecular Metal Revision Shell with either a ZCA cage or TMARS cage (Zimmer-Biomet Inc.). Pelvic discontinuity was diagnosed on pre-operative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed with failure defined as revision of the cup-cage reconstruction. Fifty-seven cup-cages in 56 patients were included with an average follow-up of 6.25 years (0.10 to 19.98 years). The average age of patients was 72.09 years (43 to 92 years) and 70.2% of patients were female. The five year Kaplan-Meier survival was 92.0% (95% CI 84.55 to 99.45) and the ten year survival was 80.5% (95% CI 58.35 to 102.65). There were 5 major complications that required revision of the cup-cage reconstruction (3 infections and 2 mechanical failures). There were 9 complications that required re-operation without revision of the cup-cage reconstruction (5 dislocations, 3 washouts for infection and one femoral revision for aseptic loosening). In our hands the cup-cage reconstruction has provided a reliable tool to address pelvic discontinuity with an acceptable complication rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 44 - 44
19 Aug 2024
Park C Lim S Park Y
Full Access

Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design geometry using the system proposed by Radaelli et al. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12‒139 months). Overall, 45 (1.4%) postoperative PFFs occurred. The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 vs. 0.7 vs. 0.7%; P=0.022). Additionally, more surgical treatments (1.7 vs. 0.5 vs. 0.7%; P=0.013) and femoral revisions (1.2 vs. 0.2 vs. 0%; P=0.004) were required for PFF in type B1 stems. After controlling for confounding variables, older age (P<0.001), diagnosis of hip fracture (P<0.001), and use of type B1 stems (P=0.001) were significant factors associated with PFF. Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients with compromised bone quality


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 50 - 50
23 Jun 2023
Zagra L D'Apolito R Tonolini S Battaglia AG
Full Access

Stem loosening can be associated with a wide spectrum of bone loss and deformity that represent key factors for choosing the most appropriate revision implant. The aim of this study was to evaluate the clinical outcomes and the survivorship of a consecutive series of THA revisions using a taper rectangular cementless stem for primary implants (Alloclassic® Zweymuller®, Zimmer Warsaw US) at medium-term follow-up. We retrospectively evaluated 113 patients (115 revisions) who underwent femoral revision with Zweymuller stem with a preoperative Paprosky I (86) or II (29) defects from January 2011 to December 2020. The mean follow up was 6 years (2–10). The median age at time of surgery was 71(41–93) with 60 males and 53 females. Osteolysis/radiolucency were observed in the following Gruen zones: I (91), II (3), III (2), VII (15), V (3), VI (1). Clinical assessment was performed by means of Harris Hip Score (HHS) and Visual Analogic Scale (VAS), whereas for the radiological analysis we used conventional x-rays of the hips. The statistical analysis was performed using Graphpad Prism v5.0 and data distribution was assessed by Shapiro-Wilk test, and Wilcoxon matched paired test was used to test the differences between preoperative and postoperative score. 9 patients were lost to fu (deceased or not available), 104 (106 hips) were evaluated. The mean HHS and VAS significantly improved at final follow-up, going from 33,84 and 5,78 preoperatively to 66,42 and 2,05 postoperatively, respectively. 28 patients (25%) showed unprogressive radiolucent lines in Gruen zones 1 and 7 with no other radiological nor clinical signs of loosening. One patient suffered from recurrence of the infection. The survivorship with stem revision as endpoint was 100%. Alloclassic Zweymüller primary stem showed good medium-term results and survival rate in revision THA for aseptic loosening and second stages of two stage revisions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 47 - 47
23 Jun 2023
Garbuz DS
Full Access

The purpose of this study was to determine long-term survival free from all-cause revision and stem-related failure, as well as radiographic and functional outcomes of the ZMR stem in revision THA. We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR Revision Hip system from the year 2000 to 2007 (minimum two-year follow-up). Of the 112 ZMR hips (110 patients) identified, a total of 106 hips (104 patients) met inclusion criteria. The mean study follow-up 13.9 years (range 2–22). Indications for index ZMR revision included aseptic loosening (72.1%), periprosthetic joint infection (17.3%), periprosthetic fracture (9.6%), and stem fracture (1.0%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. Validated patient reported outcomes were collected and available radiographs were reviewed to determine implant stability. A total of 17 hips (16.0%) underwent a re-revision of any component. The indications for re-revision were stem failure (35.3%), infection (29.4%), instability (29.4%), and aseptic loosening of the acetabular component (5.9%). The five- and 15-year all-cause survivorship was 89.5% (95% CI 86.5–92.5) and 83.0% (95% CI 79.2–86.8), respectively. There were six re-revisions for stem failure (5.7%); five for stem fracture and one for aseptic loosening. The average time to stem failure was 4.6 years (range 1.3–8.2). The five- and 15-year survivorship free from stem-related failure was 97.2% (95% CI 95.6–98.8) and 93.9% (95% CI 91.5–96.3), respectively. At final follow-up the mean Oxford hip score was 36.9 and all surviving ZMR stems were well fixed on radiographs. Femoral revision with the ZMR stem offers satisfactory long-term survivorship and promising clinical outcomes. Although uncommon, stem fracture was the most common reason for stem-related failure


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 24 - 24
19 Aug 2024
Dagneaux L Abdel MP Sierra RJ Lewallen DG Trousdale RT Berry DJ
Full Access

Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term implant survivorship, risk factors, complications, and clinical outcomes of contemporary primary THAs in this difficult cohort. Our institutional total joint registry was used to identify 119 primary THAs performed in 109 patients with an angular proximal femoral deformity between 1997 and 2017. The deformity was related to previous femoral osteotomy in 85%, and developmental or metabolic disorders in 15%. 53% had a predominantly varus angular deformity. The mean age was 44 years, mean BMI was 29 kg/m. 2. , and 59% were female. An uncemented metaphyseal fixation stem was used in 30%, an uncemented diaphyseal fixation stem in 28%, an uncemented modular body stem with metaphyseal fixation sleeve in 24%, and a cemented stem in 18%. Simultaneous corrective femoral osteotomy was performed in 18%. Kaplan-Meier survivorships and Harris hip scores were reported. Mean follow-up was 8 years. The 10-year survivorships free of femoral loosening, aseptic femoral revision, any revision, and any reoperation were 95%, 93%, 90% and 88%, respectively. Revisions occurred in 13 hips for: aseptic femoral component loosening (3), stem fracture (2), dislocation (2), aseptic acetabular loosening (2), polyethylene liner exchange (2), and infection (2). Preoperative varus angular deformities were associated with a higher risk of any revision (HR 10, p=0.03), and simultaneous osteotomies with a higher risk of any reoperation (HR 3.6, p=0.02). Mean Harris hip scores improved from 52 preoperatively to 82 at 10 years (p<0.001). In the largest series to date of primary THAs in patients with angular proximal femoral deformities, we found a good 10-year survivorship free from any revision. Varus angular deformities, particularly those treated with a simultaneous osteotomy due to the magnitude or location of the deformity, had a higher reoperation rate. Keywords: Proximal femoral deformity; dysplasia; femoral osteotomy; survivorship; revision. Level of evidence: Level III, comparative retrospective cohort


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 1 - 1
1 Nov 2021
Mallett K Trousdale R Sierra R Abdel M Berry D
Full Access

Previous work has demonstrated increased implant failure in patients with DDH compared to osteoarthritis with historic methods and implants. This study examines outcomes of modern total hip arthroplasty (THA) techniques using uncemented fixation and cross-linked PE (XLPE) bearings for DDH. A consecutive series of 879 patients with DDH who underwent primary THA with uncemented components and a XLPE bearing at a single institution between 1999 and 2016 were identified. Mean age at index arthroplasty was 51 years, with 78% females. Mean follow-up was 8 years. 5- and 10-year survivorships free of revision were 98.4% and 98%, respectively. 5- and 10-year survivorships free of reoperation for any reason were 97% and 96%, respectively. Survivorship free of acetabular revision for aseptic loosening was 99.8% at 5 and 10 years, while survivorships free of femoral revision for aseptic loosening were 99.7% at 5 years and 99.5% at 10 years. Survivorship free of reoperation for PE damage (2 liner fractures, 2 rim damage from impingement) was 99.3% at 10 years. There were no revisions for bearing surface wear or osteolysis. 13% of patients experienced complications (4% dislocation, 3.3% wound complication rate). Ten-year survivorship free of reoperation for instability was 99.2%. 8 patients developed infection requiring operation (<1%). 100 patients had a prior pelvic osteotomy (11%), which did not increase rate of complications (p=0.22) or reoperations (p=0.51). Fixation with modern uncemented implants has dramatically reduced implant loosening in patients with DDH, and the use of XLPE bearings has markedly reduced revision for PE wear/osteolysis in this young patient population, leading to dramatically improved mid/long-term survivorship compared to historic series