Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 3 - 3
1 Feb 2020
Hartwell M Sweeney RHP Marra G Saltzman M
Full Access

Background. Rotator cuff atrophy evaluated with computed tomography scans has been associated with asymmetric glenoid wear and humeral head subluxation in glenohumeral arthritis. Magnetic resonance imaging has increased sensitivity for identifying rotator cuff pathology and has not been used to investigate this relationship. The purpose of this study was to use MRI to assess the association of rotator cuff muscle atrophy and glenoid morphology in primary glenohumeral arthritis. Methods. 132 shoulders from 129 patients with primary GHOA were retrospectively reviewed and basic demographic information was collected. All patients had MRIs that included appropriate orthogonal imaging to assess glenoid morphology and rotator cuff pathology and were reviewed by two senior surgeons. All patients had intact rotator cuff tendons. Glenoid morphology was assigned using the modified-Walch classification system (types A1, A2, B1, B2, B3, C, and D) and rotator cuff fatty infiltration was assigned using Goutallier scores. Results. 46 (35%) of the shoulders had posterior wear patterns (23 type B2s, 23 type B3s). Both the infraspinatus and teres minor independently had significantly more fatty infiltration in B2 and B3 type glenoids compared to type A glenoids (p<0.001). There was a greater imbalance in posterior rotator cuff muscle fatty atrophy in B2 and B3 type glenoids compared to type A glenoids (p<0.001). However, there was no difference in axial plane imbalance between B2 and B3 glenoids (p=1.00). There was increased amount fatty infiltration of the infraspinatus among B2 and B3-type glenoids compared to type A glenoids on multivariate analysis controlling for age and gender (p<0.001). Conclusions. These results identify significant axial plane rotator cuff muscle imbalances in B2 and B3-type glenoids compared to concentrically worn glenoids, favoring a relative increase in fatty infiltration of the infraspinatus and teres minor compared to the subscapularis in glenoids with patterns of posterior wear. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 88 - 88
1 Jan 2016
Nishinaka N Suzuki K Matsuhisa T Uehara T Nagai S Tsutsui H
Full Access

Purpose. Chronic massive rotator cuff tears are challenging to repair completely because of the development of tendon retraction with inelasticity, muscle atrophy and fatty infiltration. The objective of this study was to investigate the clinical outcome and MRI findings after arthroscopic superior capsule reconstruction (ASCR) for symptomatic irreparable rotator cuff tears. Methods. From 2011 to 2013, 12 shoulders in 12 consecutive patients (mean, 70.8 years) with irreparable massive rotator cuff tears underwent ASCR using fascia lata. We used suture anchors to attach the graft medially to the glenoid superior tubercle and laterally to the greater tuberosity as same technique by Mihata et al. We added side-to-side sutures between the graft and infraspinatus tendon and between the graft and residual anterior supraspinatus/subscapularis tendon to improve force coupling. Physical examination, clinical rating system, and magnetic resonance imaging (MRI) were performed before surgery; at 6 and 12 months after surgery; and 6 months thereafter. Average follow-up was 19.1 months (12 to 28 months) after surgery. We assessed patients preoperatively by using the scoring systems of the shoulder index of the American Shoulder and Elbow Surgeons (ASES), the Japanese Orthopaedic Association, and the University of California, Los Angeles. Results. Mean active elevation increased from 59° to 111° significantly and external rotation increased from 28 to 33. The average preoperative scores were 16.0 points by ASES, 48.0 points by JOA, and 10.8 points by UCLA. Average clinical outcome scores all improved significantly after ASCR at the final follow-up (ASES, 73.3 points; JOA, 73.7 points; UCLA, 22.7 points). There was surgical complication as infection. Although infection was controlled by arthroscopic irrigation, the transplanted tendon was absorbed, and preoperative conditions did not functionally improve. Five patients had graft tear during follow-up. Postoperative active range of motion in the healed patients was significantly greater than in the unhealed patients who had graft tears. Conclusions. ASCR restored superior glenohumeral stability and function of the shoulder joint with irreparable rotator cuff tears compared to preoperative function in the cases without postoperative complications. However ratio of graft tears were 50% and clinical results of these cases were not improved sufficiently


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_27 | Pages 19 - 19
1 Jul 2013
Rashid M Butt U Birch A Crank S Temperley D Freemont A Trail I
Full Access

Our aim was to accurately determine whether muscle atrophy and fatty infiltration are reversible following cuff repair. Patients with a repairable cuff-tear were recruited and assessed clinically and radiologically (Magnetic Resonance Imaging). At surgery, supraspinatus was biopsied. Post-operatively, patients underwent clinical evaluation at standardised intervals, with further MRI and an ultrasound guided biopsy of supraspinatus at 12 months. MRI was used to characterize cuff-tears and determine the degree of muscle atrophy and fatty infiltration. Biopsy samples were fixed on-site and transported for processing. Morphometric assessments of myofibres were made and mean cross-sectional areas calculated using validated techniques. The pathologist was blinded to sample details. Statistical analysis was performed to assess differences in mean myofibre area following cuff repair and correlated with radiological findings. Eight patients were available for completed histological and radiological analysis. Six (two re-tears) demonstrated sizeable and highly statistically significant improvements in mean myofibre cross-sectional area (P=0.000–0.0253). Of the two not showing any increase in myofibre area, neither result was statistically significant (P=0.06, 0.2); one was a re-tear and one was a repair of a partial-thickness tear. Radiologically, the muscle and fatty changes had not demonstrably changed. Our finding that myofibre cross-sectional area increases following cuff repair suggests muscle atrophy is a potentially reversible process. Even with re-tears, improvements were seen. MRI features of fatty infiltration and muscle atrophy were not seen to improve however. It is likely that radiological assessment is not sensitive enough to demonstrate the reversibility of muscle atrophy seen on histological analysis at one year


Aim:. To assess the long term MRI pathoanatomical changes of unrepaired, isolated full thickness supraspinatus tears in a population of patients that had acromioplasty done for symptomatic impingement syndrome. Background:. To date there are no studies assessing the effect of acromioplasty on rotator cuff tear progression in impingement syndrome. The natural evolution of unrepaired tears suggests that small isolated tears may heal, and not all tears progress onto significant fatty change and atrophy. Which tears heal and which tears progress and the effect of acromioplasty on tear progression is still not known. Results:. There were 17 shoulders examined. Average age of our patients was 65 years at time of surgery and 73 years at follow up. The patients were divided into three groups depending on the size of the tear at the time of surgery: C1 tears (< 1cm) n = 5, C2 tears (1–2 cm) n = 8, C3 tears (2–3 cm) n = 4. The C1 tear group did the best clinically with a Constant score mean 86, 4(range 83–96) and mean Oxford score of 47 (range 46–48). The MRI findings in this group showed only one patient (20%) with significant fatty infiltration and atrophy. The C2 group had mean Constant scores of 72(range 65–98), mean Oxford score 45(range 42–48). On MRI evaluation there were 2 patients (11.8%) that had tears that had regressed in size (CI 1.4‐36.4). In the C3 group the mean Constant score was 75(range 65–85) and Oxford score 45(range 42–48). MRI evaluation revealed that all (100%) the rotator cuff tears went on to significant degeneration and atrophy in this group. No statistical difference was found between these groups when assessing Oxford score (p=0.75) and Constant scores(p=0.69). Significant associations were found between tear size and fatty infiltration (p=0.028), and tear size and atrophy (p=0.054. Conclusion:. Acromioplasty in the management of impingement syndrome may be protective when small isolated tears are noted during surgery as two tears regressed in size. Large tears all progress onto fatty infiltration and atrophy, but all three groups despite tear size had good clinical and functional outcomes. More research is needed to further understand the evolution of tears in impingement syndrome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 67 - 67
7 Nov 2023
Mogale N van Schoor A Scott J Schantz D Ilyasov V Bush TR Slade JM
Full Access

Pressure ulcers are a common occurrence in individuals with spinal cord injuries, and are attributed to prolonged sitting and limited mobility. This therefore creates the need to better understand soft tissue composition, in the attempt to prevent and treat pressure ulcers. In this study, novel approaches to imaging the soft tissue of the buttocks were investigated in the loaded and unloaded position using ultrasound (US) and magnetic resonance imaging (MRI). Twenty-six able-bodied participants (n=26, 13 males and 13 females) were recruited for this study and 1 male with a spinal cord injury. Two visits using US were required, as well as one MRI visit to evaluate soft tissue thickness and composition. US Imaging for the loaded conditions was performed using an innovative chair which allowed image acquisition in the seated upright position and MRI was done in the lateral decubitus position and loading was applied to the buttocks using a newly developed MRI compatible loader. The unloaded condition was a lateral decubitus position. Soft tissue was measured between the peak of the ischial tuberosity (IT) and the proximal femur and skin. Tissue thickness reliability for US was excellent, ICC=0.934–0.981 with no significant differences between the scan days. US and MRI measures of tissue thickness were significantly correlated (r=0.68–0.91). US underestimated unloaded tissue thicknesses with a mean bias of 0.39 – 0.56 for total tissue and muscle + tendon thickness. When the buttocks were loaded, total tissue thickness was reduced by 64.2±9.1%. US assessment of soft tissue thicknesses was reliable in both positions. The unloaded measurements using US were validated with MRI with acceptable limits of agreement, albeit tended to underestimate tissue thickness. Tissue thickness, but not fatty infiltration of muscle played a role in how the soft tissue of the buttocks responded to loading


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 26 - 26
1 Dec 2014
Haque S Umar M Khan A Osei N
Full Access

The aim of our study was to assess the outcome of caudal epidural injection for patients with low back pain in relation to fatty infiltration of spinal muscle. This is a prospective study. The spinal muscles were graded on sagittal section T1 MRI at the lower border of lumber 4 vertebra from 3 to 12 depending on the severity of fatty infiltration. The outcome of the intervention was assessed by improvement in pre and post intervention oswestry disability index score as well as visual analog pain score. Patients with significant fatty changes don't respond well to the caudal epidural injection


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 99 - 99
1 May 2019
Whiteside L
Full Access

Complete or nearly complete disruption of the attachment of the gluteus is seen in 10–20% of cases at the time of THA. Special attention is needed to identify the lesion at the time of surgery because the avulsion often is visible only after a thickened hypertrophic trochanteric bursa is removed. From 1/1/09 to 12/31/13, 525 primary hip replacements were performed by a single surgeon. After all total hip components were implanted, the greater trochanteric bursa was removed, and the gluteus medius and minimus attachments to the greater trochanter were visualised and palpated. Ninety-five hips (95 patients) were found to have damage to the muscle attachments to bone. Fifty-four hips had mild damage consisting of splits in the tendon, but no frank avulsion of abductor tendon from their bone attachments. None of these cases had severe atrophy of the abductor muscles, but all had partial fatty infiltration. All hips with this mild lesion had repair of the tendons with #5 Ticron sutures to repair the tendon bundles together, and drill holes through bone to anchor the repair to the greater trochanter. Forty-one hips had severe damage with complete or nearly complete avulsion of the gluteus medius and minimus muscles from their attachments to the greater trochanter. Thirty-five of these hips had partial fatty infiltration of the abductor muscles, but all responded to electrical stimulation. The surface of the greater trochanter was denuded of soft tissue with a rongeur, the muscles were repaired with five-seven #5 Ticron mattress sutures passed through drill holes in the greater trochanter, and a gluteus maximus flap was transferred to the posterior third of the greater trochanter and sutured under the vastus lateralis. Six hips had complete detachment of the gluteus medius and minimus muscles, severe atrophy of the muscles, and poor response of the muscles to electrical stimulation. The gluteus medius and minimus muscles were sutured to the greater trochanter, and gluteus maximus flap was transferred as in the group with functioning gluteus medius and minimus muscles. Postoperatively, patients were instructed to protect the hip for 8 weeks, then abductor exercises were started. The normal hips all had negative Trendelenburg tests at 2 and 5 years postoperative with mild lateral hip pain reported by 11 patients at 2 years, and 12 patients at 5 years. In the group of 54 with mild abductor tendon damage that were treated with simple repair, positive Trendelenburg test was found in 5 hips at 2 years and in 8 hips at 5 years. Lateral hip pain was reported in 7 hips at 2 years, and in 22 at 5 years. In the group of 35 hips with severe avulsion but good muscle tissue, who underwent repair with gluteus maximus flap transfer, all had good abduction against gravity and negative Trendelenburg tests at 2 and 5 years postoperative, and none had lateral hip pain. Of the 6 hips with complete avulsion and poor muscle who underwent abductor muscle repair and gluteus maximus flap transfer, all had weak abduction against gravity, mildly positive Trendelenburg sign, and mild lateral hip pain at 2 and 5 years postoperative. Abductor avulsion is uncommon but not rare, and is detected during THA only by direct examination of the tendon and removal of the trochanteric bursa. Simple repair of mild abductor tendon damage did not prevent progressive abductor weakness in some hips; and the increase in number of patients with lateral hip pain from 2 to 5 years suggests progressive deterioration. Augmentation of the repair with a gluteus maximus flap appears to provide a stable reconstruction of the abductor muscles, and seemed to restore abductor function in the hips with functioning muscles


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 124 - 124
1 Jul 2020
Woodmass J Wagner E Borque K Chang M Welp K Warner J
Full Access

Chronic massive irreparable rotator cuff tears represent a treatment challenge and the optimal surgical technique remains controversial. Superior capsular reconstruction (SCR) has been proposed as a means to provide superior stability to the glenohumeral joint, thus facilitating restoration of shoulder function. However, despite the growing use of SCR there is a paucity of data evaluating the outcomes when performed using a dermal allograft. The purpose of this study was to (1) report the overall survival rate (reoperation and clinical failure) of SCR (2) evaluate for pre-operative factors predicting reoperation and clinical failure. From January 1, 2015 to November 31, 2017, 65 patients were diagnosed with irreparable rotator cuff tears and consented for a superior capsular reconstruction. These surgeries were performed by 6 surgeons, all fellowship trained in either sports or shoulder and elbow fellowships. Outcomes were graded as excellent, satisfactory, or unsatisfactory using the modified Neer scale. An unsatisfactory result was defined as a clinical “failure”. The Kaplan-Meier survival models were created to analyze reoperation-free and failure-free survival for the entire group. The reconstruction was performed using a dermal allograft. There were 31 patients excluded due to insufficient follow-up (< 6 months), leaving 34 included in this study. The mean follow-up was 12 months (range, 6–23). The average number of prior surgeries was 0.91 (range, 0–5), with 52.9% of patients receiving a prior rotator cuff repair and 38.2% of patients with a prior non-rotator cuff arthroscopy procedure. The one and two-year survival-free of surgery was 64% and 44% and the one and two-year survival free of failure was 34% and 16% following SCR, respectively. For the patients that underwent a reoperation, 62.5% (n= 5/8) underwent reverse shoulder replacements, 25% (n= 2/8) latissimus dorsi tendon transfers, and 12.5% (n= 1/8) a diagnostic arthroscopy. The average period between the primary and revision surgery was 10.2 months (range, 2.1–18.5). All but two patients (75%, n= 6/8) had at least one surgery prior to the SCR. There were 14/34 (41.2%) patients who experienced pain, weakness, and restricted range of motion. These patients were defined as clinical failures with an unsatisfactory grading on Neer's criteria. Previous surgery predicted reoperation (80% vs 43%, p = 0.03). Female gender predicted clinical failure (100% vs 43%, p < 0 .01). Superior Capsule Reconstruction performed for large to massive rotator cuff tears has a high rate of persistent pain and limited function leading to clinical failure in 65% (n= 22/34) of patients. The rate of failure is increased in revision cases, female gender and increased Goutallier fatty infiltration of the infraspinatus. Narrowed indications are recommended given the surgical complexity and high rate of early failure


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 23 - 23
1 Nov 2015
Burkhead W
Full Access

Subscapularis repair and integrity after a primary total shoulder arthroplasty is critical for successful outcomes. One should be familiar with the 3 basic takedown and repair techniques commonly utilised. Subscapularis repair after reverse shoulder arthroplasty is not as critical and in some cases may be detrimental to return of external rotation strength and motion. Subscapularis tenotomy: The tendon is incised approximately 1 cm from the lesser tuberosity and an oblique incision is created from proximal lateral to distal medial stopping at the sentinel vessels. A combination of tendon-to-tendon figure of 8 sutures. Lesser tuberosity osteotomy: This approach is helpful not only in obtaining a bone-to-bone healing, but also in the exposure. Osteotomies range from a fleck of bone in patients with minimal deformity, to a C-shaped osteotomy including part of the head which facilitates exposure of the posterior glenoid. Despite an ability to document radiographic healing of the lesser tuberosity fragment, this technique does not prevent fatty infiltration of the subscapularis. Subscapularis Peel: This repair requires tendon healing to bone and probably incomplete, in most cases, reconstitution of a normal enthesis. External rotation can be gained by recessing the subscapularis insertion medially with the arm in external rotation. While bone-to-tendon sutures are the gold standard, augmentation of the sutures using a prosthesis as the anchor has led to the development of prostheses with multiple holes. Dual row repair of the tendon, however, may lead to medial rupture


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 100 - 100
1 Jan 2016
Kenmoku T Miyajima G Higashiyama R Takahira N Takaso M
Full Access

Introduction. Proximal humeral fracture occurs most frequently in elderly and usually unite within 12 weeks. Malunion is more common than nonunion. And even if nonunion occurs, we usually treat it by the blade plate. Norris et al. reported hemiarthroplasty is indicated for severe degenerative changes of the articular surface, osteonecrosis of the humeral head, or osteopenia severe enough to jeopardize fixation in order patients. Therefore, it is not common that hemiarthroplasty is used for primary treatment of the proximal humeral pseudoarthrosis. We report a case of proximal humerus pseudoarthrosis which was treated by hemiarthroplasty. Case. A patients is 75 years old male. He was injured by falling from ladder. He was diagnosed proximal humeral fracture Neer type2. After he was followed conservatively for one year, he was referred to our hospital. In X-ray film and CT, the humeral head was scraped by the humeral shaft that was tucked inward to humeral head.(Figure 1) In MRI, rotator cuff muscles were left. The fatty infiltration was stage 1 in the Gourtallier classification. (Figure 2)And osteoarthritis of shoulder was not so severe. Therefore, we decided to do hemiarthroplasty. We used the SMR implant (Lima Corporate, Milano, Italy). Surgical reconstruction was done using a deltpectral approach. Lesser tuberosity was cut from greater tuberosity with subscaplaris muscle. We used the cementless stem. Each fragments and stem was fixed using FiberWire (Arthrex, Florida USA), after autograft which scraped from the reseceted humeral head was stuffed. After the operation, the shoulder was fixed by brace for 4weeks. The passive ROM exercise was started from 21 days later. The Active ROM exercise was started at 28 days later. Three months later, the pseudoarthrosis united successfully. (Figure 3) The active flexion was improved from 20 degrees to 110 degrees. The active abduction was from 20 degrees to 90 degrees. USLA score was improved from 10 to 26. Discussion. In this case, the pseudoarthrosis is united successfully. Therefore, the cementless hemiarthroplasty is useful for treatment for the proximal humerus pseudoarthrosis with severe humeral head bone defect


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 86 - 86
1 Mar 2012
Bhadra A Abraham R Malkani A
Full Access

Aim. To assess clinical outcome of massive rotator cuff tear repair using triceps myotendinous flap. Method. This is a prospective cohort of 43 patients (24 male, 19 female) with average age of 62 years. The primary indication of surgery was pain. Patients with massive rotator cuff tear involving supraspinatus and infraspinatus, showing retraction and fatty infiltration in MRI were selected. Few (8/43) were with failed surgical treatment and rest had conservative treatment failed. They underwent rotator cuff repair during Feb 1999 to Jan 2004. The long head of the triceps was detached from the olecranon, rotated 180 degrees from its pivot point with its major vascular pedicle under the deltoid and acromion through the posterior capsule and attached to the greater tuberosity and any remnant of remaining cuff. All patients were assessed pre-operatively, at 3, 6 and 12 months post-operatively clinically and also using UCLA pain and functional score for shoulder. Shoulder range of motion was assessed before and after the surgery. 24 patients had minimum of 1 year and 19 had 2 year minimum follow-up. Results. The mean total UCLA score of 9.7 pre-operatively improved to 27.8 (p<0.0001) following the operation. The mean pre-operative UCLA pain score 2.2 improved to 7.8 post-operatively (p<0.001). The UCLA functional score improved from a pre-operative average of 3.4 to 8.2 (p<0.0001) following the operation. There was significant improvement in forward elevation, external and internal rotation but not abduction. There was no weakness in elbow extension. Complications: 3 superficial infections, 1 ulnar neuritis (resolved in 6 weeks), 1 olecranon bursitis (resolved in 3 months). Conclusion. Long head triceps tendon transfer is an effective technique to alleviate pain and improve functions in patients with massive rotator cuff tear, specially in difficult group of patients with limited options


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 150 - 150
1 Dec 2013
Wiater B Moravek J Pinkas D Koueiter D Maerz T Marcantonio D Wiater JM
Full Access

Introduction:. Reverse total shoulder arthroplasty (RTSA) has become instrumental in relieving pain and returning function to patients with end-stage rotator cuff disease. A distalized and medialized center of rotation in addition to a semi-constrained implant design allows the deltoid to substitute for the non-functioning rotator cuff. The purpose of this study was to examine the relationship between specific deltoid and rotator cuff muscle parameters and functional outcomes following RTSA. Methods:. Patients undergoing RTSA by a single surgeon were enrolled in a prospective, IRB approved RTSA outcomes registry. Inclusion criteria were diagnosis of cuff tear arthropathy or massive rotator cuff tear, a minimum 2-year follow-up, and a preoperative shoulder MRI. We excluded patients undergoing revision arthroplasty, fracture, and a history of previous open shoulder surgery. For the 28 patients meeting our criteria, the cross-sectional area (CSA) of the anterior, middle, and posterior deltoid were measured on an axial MRI (Figure 1). Fatty infiltration (FI) of the deltoid, supraspinatus (SS), infraspinatus (IS), teres minor, and subscapularis were assessed on sagittal T1-MRI quantitatively via image processing and qualitatively on the 5-point Fuchs scale by a fellowship-trained musculoskeletal radiologist. Outcome measures included active forward elevation (aFE), active external rotation (aER), active internal rotation (aIR), strength in abduction, Constant-Murley score (CMS), Subjective Shoulder Value (SSV), Visual Analogue Scale (VAS) pain, and American Shoulder and Elbow Surgeons (ASES) total and ASES activities of daily living (ADL) scores as assessed by a trained, clinical research nurse. Correlation of deltoid CSA and FI with outcomes measures was analyzed with a Spearman rank correlation coefficient (ρ) with significance at P < .05. Results:. The correlations between preoperative deltoid size and quantitative deltoid FI to postoperative function are shown in Table 1. The total deltoid CSA showed the most significant, positive correlations with outcome measures. The anterior deltoid CSA showed the strongest correlation to postoperative strength in abduction. Quantitative FI of the deltoid was negatively associated with several outcome measures (Table 1). Quantitative FI of the SS and IS demonstrated a significant negative correlation with aER (ρ = −.732, P = .039 and ρ = −.790, P = .004, respectively). The grade of FI, as assessed using the Fuchs scale, did not correlate to any clinical outcome data. Discussion and Conclusion:. Preoperative deltoid size and FI of the deltoid and the rotator cuff muscles correlate to 2-year functional outcomes following RTSA. The anterior, posterior, and total CSA of the deltoid had significant, positive associations with several outcome measures, whereas FI of the deltoid, SS, and IS had significant, negative associations, particularly with humeral rotation. In the future, optimization of deltoid and rotator cuff muscle function preoperatively may improve functional outcomes in RTSA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 126 - 126
1 May 2016
Laky B Heuberer P Koelblinger R Kriegleder B Anderl W Pauzenberger L
Full Access

Hemi shoulder arthroplasty is a rather successful procedure although revision surgery due to secondary glenoid erosion is reported in more than 25%. The downside of common shoulder arthroplasty is that in a deltopectoral approach the subscapularis tendon needs to be detached for exposure of the humeral head. Refixation of subscapularis tendon is associated with a retear rate of 4%, furthermore with progressing fatty muscle infiltration and loss of function. In case of revision surgery a second subscapularis tendon detachment is even more associated with worse function. Thus, arthroscopic humeral head resurfacing is an expedient alternative for minimal invasive humeral head arthroplasty without compromising subscapularis function. The purpose of this study was to report first clinical and subjective results after arthroscopic-assisted resurfacing of the humeral head. For this prospective case series, 24 patients (7 females, 17 males; mean age 59 years, range 42–73 years) undergoing arthroscopic-assisted partial shoulder resurfacing with the partial eclipse prosthesis were included in the study. Clinical conditions and subjective assessments were evaluated before surgery and annually thereafter using the Constant score (CS), active range of motion (ROM), visual analog scale (VAS) for pain, and the American Shoulder and Elbow Surgeons scale (ASES). Radiological outcomes and major complications were monitored. The mean CS for all patients improved significantly from 51 points preoperatively to 83 points 12 months after surgery (p=0.005). Trends towards increasing ROMs were detected. Subjective scores significantly improved from baseline to the 1-year follow-up (VAS: from 6.4 to 2.5, p=0.010; ASES: from 47 to 76, p=0.026). The majority of patients (88%) stated that they would undergo the procedure again. Revisions were indicated in 17% due to progression of osteoarthritis. Arthroscopic-assisted partial humeral head resurfacing as a minimal invasive procedure with the advantages of bone stock preservation and intact subscapularis tendon allowed immediate postoperative active mobilization and provided significant improvements in subjective outcome. In case of revision surgery a primary situation was encountered with postoperative results comparable to primary arthroplasty


Bone & Joint 360
Vol. 5, Issue 1 | Pages 12 - 14
1 Feb 2016


Bone & Joint Research
Vol. 3, Issue 6 | Pages 193 - 202
1 Jun 2014
Hast MW Zuskov A Soslowsky LJ

Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing.

Cite this article: Bone Joint Res 2014;3:193–202.