Advertisement for orthosearch.org.uk
Results 1 - 20 of 57
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_6 | Pages 11 - 11
1 Jun 2022
Oosthuysen W McQuarrie K Crane E Madeley N Kumar CS
Full Access

The surgical care of extra-articular distal tibial fractures remains controversial. This study looks at the radiological outcomes of distal tibial fractures treated with either a direct medial or anterolateral plate, with or without plating of the fibula, to assess the outcome and complications associated with these 2 approaches. This is a retrospective review of 80 patients with distal tibial extra-articular fractures, treated with an open reduction and plating, between 2008 and 2019 at Glasgow Royal Infirmary. Case notes and x-rays were reviewed. Of those tibial fractures fixed with only a medial plate, 78% united (28/36), 5% (2/36) had a non-union and 17% (6/36) a malunion. In the group treated with a combination of medial tibial and fibular plating, the figures were; 71% (15/21), 19% (4/21) and 10% (2/21). However, in the group treated with anterolateral plating of the tibia alone, only 53% (8/15) united, with a 20% (3/15) non-union and 13% (2/15) malunion rate. Additionally in this group, there were 2 patients (13%) with loss of fracture reduction within the first two months of fracture fixation, requiring revision surgery. Interestingly, of the 8 patients treated with anterolateral tibial and fibular plating, 88% (7/8) showed full union and only one (12%) had a non-union, with no malunions is this group. It would appear that medial tibial and a combination of medial tibial and fibular plating, have superior outcomes compared to anterolateral plating. Results suggest, if anterolateral plating is done, this should be augmented by fixation of the fibular fracture as well


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 7 - 7
1 Dec 2023
Jones M Pinheiro V Church S Ball S Williams A
Full Access

Introduction. To determine if elite athletes can return to professional sport after MCL or posterolateral (PLC) reconstruction using LARS ligaments. The secondary aims are to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries, and complications. Methods. A retrospective review of all extra-articular knee ligament reconstructions, utilising a LARS synthetic ligament, by 3 sports knee surgeons between 2013 and 2020 was undertaken. All elite athletes aged over 16 years and a minimum of 2 years post reconstruction were included. No LARS were used for ACL reconstructions, and they were excluded if a LARS ligament was used for a PCL reconstruction. Return to play (RTP) was defined as competing at professional level or national/ international level in amateur sport. Results. Sixty-four (84.2%) MCL reconstructions and 12 (15.8%) PLC reconstructions were included. 52 (68.4%) underwent concomitant autograft cruciate(s) reconstruction including 6 (7.8%) bicruciate reconstructions. The mean age was 25.1 years (SD +/− 4.50). 35 (46.1%) were footballers and 35 (46.1%) were rugby players. Sixty-seven athletes (88.2%) returned to elite sport, 7 (9.2%) did not RTP and RTP status was unknown for 2 (2.6%) (Figure 1). 65 out of 67 (97.0%) RTP at the same/higher Tegner level. 56 (83.6%) and 20 (57.1%) were still playing at 2- and 5-years post-surgery Six (7.9%) players required further surgery due to irritation from the metal fixation implants. One had an inflammation adjacent to the synthetic material at the femoral end and the other cases involved the tibial staples. All six cases were able to RTP. One athlete, following bicruciate /MCL surgery had the LARS removed due to laxity. There was one MCL re-rupture, sustained while jumping, 4 years after returning to football. Conclusions. Utilising LARS in extra-articular knee ligament reconstructions allows 88.2% of athletes with a variety of knee ligament injuries to return to elite sport. The results compare well regarding RTP, complication, and revision rates with the published evidence for other types of MCL and PLC grafts. This, coupled with 57% of athletes still playing 5 years post-surgery suggests the LARS is safe and effective in these cases. For any figures or tables, please contact authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 837 - 840
1 Jun 2005
Azzopardi T Ehrendorfer S Coulton T Abela M

We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular fractures of the distal radius to compare the outcome of immobilisation in a cast alone with that using supplementary, percutaneous pinning. Patients treated by percutaneous wires had a statistically significant improvement in dorsal angulation (mean 7°), radial length (mean 3 mm) and radial inclination (mean 3 mm) at one year. However, there was no significant difference in functional outcome in terms of pain, range of movement, grip strength, activities of daily living and the SF-36 score except for an improved range of movement in ulnar deviation in the percutaneous wire group. One patient developed a pin-track infection which required removal of the wires at two weeks. We conclude that percutaneous pinning of unstable, extra-articular fractures of the distal radius provides only a marginal improvement in the radiological parameters compared with immobilisation in a cast alone. This does not correlate with an improved functional outcome in a low-demand, elderly population


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims

The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols.

Methods

A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims. This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect. Patients and Methods. A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively. Results. The mean time to follow-up was 55 months (12 to 126). Overall, 16 (94%) of the patients achieved radiological filling of their bony defect and united to the native bone ends proximally and distally, resulting in a functioning limb. Complications included device failure in two patients (12%), infection in two (12%), and wound dehiscence in one (6%). Four patients (24%) required secondary surgery, four (24%) had a residual limb-length discrepancy, and one (6%) had a residual angular limb deformity. Conclusion. A titanium mesh cage is a useful adjunct in the treatment of an extra-articular segmental defect in a long bone. Cite this article: Bone Joint J 2018;100-B:646–51


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 624 - 633
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML

Aim. The aim of this study was to compare the cost-effectiveness of intramedullary nail fixation and ‘locking’ plate fixation in the treatment of extra-articular fractures of the distal tibia. Patients and Methods. An economic evaluation was conducted from the perspective of the United Kingdom National Health Service (NHS) and personal social services (PSS), based on evidence from the Fixation of Distal Tibia Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients were available for analysis. Costs were collected prospectively over the 12-month follow-up period using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality adjusted life year (QALY) gained, and net monetary benefit. Sensitivity analyses were conducted to test the robustness of cost-effectiveness estimates. Results. Mean NHS and PSS costs were significantly lower for patients treated with an intramedullary nail than for those treated with a locking plate (-£970, 95% confidence interval (CI) -1685 to -256; p = 0.05). There was a small increase in QALYs gained in the nail fixation group (0.01, 95% CI -0.03 to 0.06; p = 0.52). The probability of cost-effectiveness for nail fixation exceeded 90% at cost-effectiveness thresholds as low as £15 000 per additional QALY. The cost-effectiveness results remained robust to several sensitivity analyses. Conclusion. This trial-based economic evaluation suggests that nail fixation is a cost-effective alternative to locking plate fixation. Cite this article: Bone Joint J 2018;100-B:624–33


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 15 - 15
1 Apr 2013
Kim J Oh CW Oh JK Lee HJ Kyung HS
Full Access

Background. To establish relative fixation strengths of a single lateral locking plate, a double locking plate, and a tibial nail in treatment of proximal tibial extra-articular fractures. Methods. Three groups of composite tibial synthetic bones consisting of 5 specimens per group were included; lateral plating (LP) using a LCP-PLT (locking compression plate-proximal lateral tibia), double plating (DP) using a LCP-PLT and a LCP-MPT (locking compression plate-medial proximal tibia), and intramedullary nailing (IN) using an ETN (expert tibial nail). To simulate a comminuted fracture model, a gap osteotomy measuring 1 cm was cut 8 cm below the joint. For each tibia, a minimal preload of 100N was applied before loading to failure. A vertical load was applied at 25mm/min until tibia failure. Results. For axial loading, fixation strength of DP (14387.3N, SD=1852.1) was 17.5% greater than that of LP (12249.3N, SD=1371.6), and 60% less than that of IN (22879.6N, SD=1578.8) (p<0.001). For ultimate displacement in axial loading, similar results were observed for LP (5.74mm, SD=1.01) and DP (4.45mm, SD=0.96), with a larger displacement for IN (5.84mm, SD=0.99). Conclusion. In biomechanical testing of a comminuted proximal tibial fracture model, DP proved stronger than LP in terms of ultimate strength. IN proved strongest; however, DP may be an acceptable alternative for minimally invasive osteosynthesis, which may be technically difficult to fix using a nail


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 375 - 375
1 Sep 2012
Zaffagnini S Marcheggiani Muccioli GM Bonanzinga T Signorelli C Lopomo N Bignozzi S Bruni D Nitri M Bondi A Marcacci M
Full Access

INTRODUCTION. This study aimed to intra-operatively quantify the improvements in knee stability given both by anatomic double-bundle (ADB) and single-bundle with additional lateral plasty (SBLP) ACL reconstruction using a navigation system. MATERIALS AND METHODS. We prospectively included 35 consecutive patients, with an isolated anterior cruciate ligament injury, that underwent both ADB and SBLP ACL reconstruction (15 ADB, 20 SBLP). The testing protocol included anterior/posterior displacement at 30° and 90° of flexion (AP30–AP90), internal/external rotation at 30° and 90° of flexion (IE 30–IE90) and varus/valgus test at 0° and 30° of flexion (VV0–VV30); pivot-shift (PS) test was used to determine dynamic laxity. The tests were manually performed before and after the ACL reconstruction and the data were acquired by means a surgical navigation system (BLU-IGS, Orthokey, USA). Comparisons of pre- and post-reconstruction laxities were made using paired Student t-test (P=0.05) within the same group; comparison between ADB and SBLP groups was indeed performed using independent Student t-test (P=0.05), analysing both starting pre-operative condition and post-operative one. RESULTS. Statistically significant reduction of the global amount of laxity and global displacement was observed for both reconstructions (p<0.05) in all the performed clinical tests. Statistical differences was found between the two reconstruction considering the recovery (pre-post laxities) due to the each reconstruction, in VV0 (SBLP: 3.7±0.2° and ADB: 2.3±0.5°, p<0.0001) and in IE90 (SBLP: 9.2±3.1° and ADB: 5.0±2.8°, p=0.0022). Statistical differences were also found between the two reconstruction considering the recovery of global displacement, in particular for the lateral compartment during AP90 SBLP: 8.8±1.0 mm, ADB: 6.4±0.4 mm, p<0.0001), for the maximal lateral joint opening during VV0 (SBLP: 4.5±1.2 mm, ADB: 1.2±1.1 mm, p<0.0001) and VV30 (SBLP 3.5±1.3 mm, ADB 1.8±0.1 mm, p=0.0013) and both for the medial and lateral AP displacement during IE90 (in in medial compartment SBLP:5.6±0.6 mm, ADB: 2.7±0.7 mm, p<0.0001, in lateral compartment SBLP:8.2±1.0 mm, ADB: 3.9±0.8 mm, p<0.0001). During PS test ADB patients revealed less “hysteresis” after reconstruction (p=0.0005). Moreover SBLP patients presented more acceleration after the reconstruction compared to ADB and more evident displacement (p=0.0009). DISCUSSION. Both the reconstructions worked similarly for what concerns knee static laxity. The considered extra-articular procedure plays an important role in better controlling lateral tibial compartment displacement in drawer test and in controlling maximal lateral joint opening both at 0° and 30° of flexion. On the other hand the ADB reconstruction better restores the dynamic behaviour of the joint under PS test


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 704 - 708
1 May 2012
Mauffrey C McGuinness K Parsons N Achten J Costa ML

The ideal form of fixation for displaced, extra-articular fractures of the distal tibia remains controversial. In the UK, open reduction and internal fixation with locking-plates and intramedullary nailing are the two most common forms of treatment. Both techniques provide reliable fixation but both are associated with specific complications. There is little information regarding the functional recovery following either procedure.

We performed a randomised pilot trial to determine the functional outcome of 24 adult patients treated with either a locking-plate (n = 12) or an intramedullary nailing (n = 12). At six months, there was an adjusted difference of 13 points in the Disability Rating Index in favour of the intramedullary nail. However, this was not statistically significant in this pilot trial (p = 0.498). A total of seven patients required further surgery in the locking-plate group and one in the intramedullary nail group.

This study suggests that there may be clinically relevant, functional differences in patients treated with nail versus locking-plate fixation for fractures of the distal tibia and differences in related complications. Further trials are required to confirm the findings of this pilot investigation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 9 - 9
1 Dec 2023
Garneti A Clark M Stoddard J Hancock G Hampton M
Full Access

Introduction. Anterior cruciate ligament reconstruction (ACLr) is the most widely published operation in the orthopaedic literature. Over recent years there has been increased interest in the surgical technique and role of concomitant procedures performed during ACLr. The National Ligament Registry (NLR) collects robust data on ACLr performed in the UK. In this registry analysis we explore trends in ACLr surgery and how they relate to published literature and the growing industry portfolio available to surgeons. Methods. Using data from the NLR, 14,352 ACLr performed between 2013–2021 were analysed. High impact papers on ACLr were then cross referenced against this data to see if surgical practice was influenced by literature or whether surgical practice dictated publication. Common trends were also compared to key surgical industry portfolios (Arthrex, Smith and Nephew) to see how new technology influenced surgical practice. Results. The number of ACLr performed in isolation is decreasing. The number of ACL reconstructions involving meniscal surgery shows an increasing trend since 2013, with 57% of ACLr in 2021 now involving meniscus surgery. The number of ACLr with lateral extra-articular tenodesis (LET) has increased sharply since 2018, preceding the stability trial publication in 2020. Graft preference and size has remained static despite the introduction of new graft harvest and fixation devices. Additional procedures such as other ligament reconstruction and additional cartilage surgery have also remained static over time. Conclusion. In this analysis we looked at surgical trends in ACLr and their relation to literature and industry. Meniscal intervention is increasing, in keeping with the growing level of literature in this area. In the setting of LET, a high impact level 1 study appears to have significantly changed the practice of UK surgeons with a sharp increase in the number of LET procedures being performed. Industry appears to have little influence on the change in surgical trends, suggesting high quality evidence is what drives innovation in ACLr while industry supports rather than influences innovation. It will be interesting to see the impact of the stability 2 study, recent work on the medial structures of the knee and the commissioning of cartilage centres on future trends


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 2 - 2
1 Dec 2023
Basheer S Kwaees T Tang C Ali F Haslam P Nicolaou N
Full Access

Objectives. Congenital cruciate ligament deficiency is a rare condition that may occur in isolation or in association with longitudinal limb deficiencies such as fibular hemimelia or proximal femoral focal deficiency. Often anomalies of the menisci and their attachments can be very abnormal and impact on surgical management by standard techniques. Arthroscopic surgical knee reconstruction is undertaken to improve symptomatic instability and/or to stabilise and protect the knee for future planned limb lengthening surgery. The aim of this study is to evaluate the arthroscopic findings of patients undergoing surgery for congenital cruciate ligament deficiency, and specifically to determine the frequency and types of meniscal anatomical variations seen in these cases. Methods. Patients undergoing surgery for congenital cruciate ligament deficiency were identified from a prospectively collated database. Diagnosis was confirmed through review of the clinical notes and imaging. Operative notes and 4K saved arthroscopic images and video recordings for these cases were reviewed. Results. Over a six-year period (July 2017 – September 2023), 42 patients underwent surgery for congenital ligament deficiency and tibiofemoral instability (45 surgical episodes). Median age of patients at time of surgery was 10 years (range 4 – 17 years). The most frequent diagnosis was congenital longitudinal limb deficiency syndromes in 27 cases, with the most frequent being fibular hemimelia. Isolated congenital ligament deficiency without any other associated extra-articular manifestations occurred in 11 cases. Absence of meniscal root attachments or hypertrophy of meniscofemoral ligaments acting as ‘pseudo-cruciates’ were seen in over 25% of patients. In isolated ACL deficiency these were injured causing onset of instability symptoms and pain following trauma. Often these abnormal structures required addressing to allow surgical reconstruction. Conclusions. Our findings demonstrate that there are often meniscal variations seen in association with congenital absence or hypoplasia of the cruciate ligaments. In these patients hypertrophied meniscofemoral ligaments may act as cruciate-like structures and play a role in providing a degree of sagittal plane stability to the knee. However, when the knee becomes unstable to the point that cruciate ligament reconstruction is indicated, these meniscal variants may often require stabilisation using complex meniscal root repair techniques or variations to standard cruciate ligament reconstruction techniques to accommodate the variant anatomy


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 629 - 637
1 May 2008
Forward DP Davis TRC Sithole JS

Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42). No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and extra-articular malunion (dorsal angulation and radial shortening) as well as intra-articular injury. Multivariate analysis revealed that grip strength had fallen to 89% of that of the uninjured side in the presence of dorsal malunion, but no measure of extra-articular malunion was significantly related to either the Patient Evaluation Measure or DASH scores. While anatomical reduction is the principal aim of treatment, imperfect reduction of these fractures may not result in symptomatic arthritis in the long term, and this should be considered when counselling patients on the risks and benefits of the many treatment options available


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims

To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial.

Methods

The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 1003 - 1008
1 Jul 2016
Fenton P Al-Nammari S Blundell C Davies M

Aims. Although infrequent, a fracture of the cuboid can lead to significant disruption of the integrity of the midfoot and its function. The purpose of this study was to classify the pattern of fractures of the cuboid, relate them to the mechanism of injury and suggest methods of managing them. Patients and Methods. We performed a retrospective review of patients with radiologically reported cuboid fractures. Fractures were grouped according to commonly occurring patterns of injury. A total of 192 fractures in 188 patients were included. They were classified into five patterns of injury. Results. Type 1 fractures (93 fractures, 48.4%) are simple avulsion injuries involving the capsule of the calcaneo-cuboid joint. Type 2 fractures (25 fractures, 13%) are isolated extra-articular injuries involving the body of the cuboid. Type 3 injuries (13 factures, 6.8%) are intra-articular fractures solely within the body of the cuboid. Type 4 fractures (35 fractures, 18.2%) are associated with disruption of the midfoot and tarsometatarsal injuries. Type 5 fractures (26 fractures, 13.5%) occur in conjunction with disruption of the mid-tarsal joint and either crushing of the lateral column alone or of both medial and lateral columns. Fractures with significant articular disruption or with loss of length of the lateral column underwent fixation. This involved either internal fixation to restore the anatomy of the cuboid and/or restoration of the length of the columns with bridging constructs using internal or external fixation. Conclusion. A classification system for fractures of the cuboid is proposed in relation to the mechanism of injury. The treatment of these fractures is described. Cite this article: Bone Joint J 2016;98-B:1003–8


Bone & Joint Open
Vol. 3, Issue 9 | Pages 726 - 732
16 Sep 2022
Hutchison A Bodger O Whelan R Russell ID Man W Williams P Bebbington A

Aims

We introduced a self-care pathway for minimally displaced distal radius fractures, which involved the patient being discharged from a Virtual Fracture Clinic (VFC) without a physical review and being provided with written instructions on how to remove their own cast or splint at home, plus advice on exercises and return to function.

Methods

All patients managed via this protocol between March and October 2020 were contacted by a medical secretary at a minimum of six months post-injury. The patients were asked to complete the Patient-Rated Wrist Evaluation (PRWE), a satisfaction questionnaire, advise if they had required surgery and/or contacted any health professional, and were also asked for any recommendations on how to improve the service. A review with a hand surgeon was organized if required, and a cost analysis was also conducted.


Aims

Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance.

Methods

We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XV | Pages 20 - 20
1 Apr 2012
Bonner T Green S McMurty I
Full Access

Background. Locking internal fixation through a relatively small surgical dissection presents an innovative technique for managing distal tibial extra-articular fractures. The aim of this study is to evaluate the biomechanical properties of one locking internal fixation plate used to treat these injuries. Method. An AO/OTA43-A3 fracture was created in synthetic composite tibiae. Locking internal fixation was achieved with an anatomically pre-contoured medial distal tibial locking plate. Comparisons were made between different screw configurations in holes proximal to the fracture and monocortical versus bicortical fixation. Axial stiffness was measured using a universal materials testing machine. Finite element analysis (FEA) was used to model the elastic deformation of the constructs. Outcome measures were axial stiffness under physiological loading conditions and compression load to failure. Results. A trend towards reduced mean axial stiffness from the bicortical to the monocortical fixation constructs was observed. The physical model demonstrated no difference in measured mean axial stiffness between constructs with all screw holes filled and constructs with 2 screws in the holes closest and furthest from the fracture site. There was a 19% reduction in mean measured axial stiffness between constructs with all holes filled and in constructs with 2 screws in adjacent holes furthest from the fracture site (p<0.05). FEA predicted increased plate deflection and reduced construct axial stiffness with increasing distance of screw placement from the osteotomy site. Conclusion. Axial stiffness of distal tibial extra-articular metaphyseal fractures stabilized by locking internal fixation is dependent upon the configuration of the screw in the plate


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 994 - 999
1 Sep 2024
El-Khaldi I Gude MH Gundtoft PH Viberg B

Aims

Pneumatic tourniquets are often used during the surgical treatment of unstable traumatic ankle fractures. The aim of this study was to assess the risk of reoperation after open reduction and internal fixation of ankle fractures with and without the use of pneumatic tourniquets.

Methods

This was a population-based cohort study using data from the Danish Fracture Database with a follow-up period of 24 months. Data were linked to the Danish National Patient Registry to ensure complete information regarding reoperations due to complications, which were divided into major and minor. The relative risk of reoperations for the tourniquet group compared with the non-tourniquet group was estimated using Cox proportional hazards modelling.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 623 - 627
8 Aug 2022
Francis JL Battle JM Hardman J Anakwe RE

Aims

Fractures of the distal radius are common, and form a considerable proportion of the trauma workload. We conducted a study to examine the patterns of injury and treatment for adult patients presenting with distal radius fractures to a major trauma centre serving an urban population.

Methods

We undertook a retrospective cohort study to identify all patients treated at our major trauma centre for a distal radius fracture between 1 June 2018 and 1 May 2021. We reviewed the medical records and imaging for each patient to examine patterns of injury and treatment. We undertook a binomial logistic regression to produce a predictive model for operative fixation or inpatient admission.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 16 - 16
1 Jun 2017
Giannoudis V Ewins E Foster P Taylor M Harwood P
Full Access

Introduction. Distal tibial fractures are notoriously difficult to treat and a lack of consensus remains on the best approach. This study examined clinical and functional outcomes in such patients treated definitively by circular external fixation (Ilizarov). Patients and Methods: Between July 2011 and May 2016, patients with fractures extending to within 1 muller square of the ankle were identified from our prospective Ilizarov database. Existing data was supplemented by review of clinical records. Fractures were classified according to the AO/OTA classification. Functional outcome data, including general measures of health related quality of life (SF-12 and Euroqol) and limb specific scores (Olerud and Molander Score and Lysholm scores) had been routinely collected for part of the study period. Patients in whom this had not been collected were asked to complete these by post. Adverse events were documented according to Paley's classification of: problems, obstacles and complications. Results. 142 patients with 143 fractures were identified, 40 (28%) were open, 94 (66%) were intra-articular, 85 (59%) were tertiary referrals. 32% were type 1, 28%, type 2 and 40% type 3 AO/OTA severity. 139 (97%) of the fractures united (2 non-unions, 1 amputation and 2 delayed unions who remain in frames), at a median of 165 days (range 104 to 429, IQR 136 to 201). 62% united by 6 months, 87% by 9 months and 94% by 1 year. Both non-unions have united with further treatment. Closed fractures united more rapidly than open (median 157 vs 185 days; p=0.003) and true Pilon (43C3) fractures took longer to unite other fractures (median 156 vs 190 days; p<0.001). 34% of patients encountered a problem, 12% an obstacle and 10% a complication. Of the complications, 6 (4%) were minor, 5 (3.5%) major not interfering with the goals of treatment and 4 (3%) major interfering with treatment goals (including the 2 patients with non-union and 1 who underwent amputation as well as 1 significant mal-union). This will increase to 4% if the 2 delayed unions fail to unite. Overall 56% reported good or excellent ankle scores at last report, 28% fair and 16% poor. Closed, extra-articular and non-43C3 fractures had better functional outcome scores than open, intra-articular and 43C3 fractures respectively. Conclusions. This study demonstrates a high union and low serious complication rate, suggesting that external ring fixation is a safe and effective treatment for these injuries. *Judged best paper*