Introduction:. Recently, patient expectations regarding the outcomes of total knee arthroplasty (TKA) have increase due to advances in knee implant design, surgical techniques, and procedure safety. However, outcomes do not always meet preoperative expectations. The purpose of this study is to investigate what Korean patients expect from their TKA and relationship between Pre-TKA
Over the past decade, there has been an increase in the number of total knee arthropalsty (TKA). Demand of TKA for the young patients who often have high physical demands is also increasing. However, the revision rate in such young patients is much higher due to polyethylene (PE) wear and instability (Julin J, Acta Orthop 2010). Therefore, next generation total knee prostheses are expected to decrease PE wear and to provide stability. Although Patients who underwent bilateral staged TKAs were more likely to prefer medial pivot prosthesis or ACL-PCL retaining prosthesis than the other types of prostheses, because they feels “more stable overall” (Pritchett JW, J Arthroplasty 2011). The excellent mid-term clinical results of those newly introduced total knee prosthesis, such as alumina medial pivot TKA (Iida T, ORS 2008), medial pivot TKA (Mannan K, JBJS Br 2009, Kakachalions T, Knee 2009), ACL-PCL retaining TKA (Clouter JM, JBJS Am 1999), and highly cross-linked PE (Hodrick JT, CORR 2008), have been reported. From the point of view of
Introduction. Positive expectations can increase compliance with treatment and realistic expectations may reduce postoperative dissatisfaction. Recently there are articles regarding expectations of patients from their TKA in western literature and only few articles based on Korean populations which don't encompass the whole spectrum of expectations in Korean patients. In all those articles based on pre-operative
Introduction. Patients-reported outcome measures (PROMs) have been reported as the important methods to evaluate clinical outcomes in total knee arthroplasty (TKA). The patient satisfaction score in Knee Society Score (KSS-2011) has been used in the recent literatures. Patient satisfaction was subjective parameter, and would be affected by multiple factors including psychological factors and physical conditions at not only affected joint but also elsewhere in the body. The question was raised regarding the consistency of patient satisfaction score in KSS-2011 to other PROMs. The purpose of this study was to investigate the correlation of patient satisfaction in KSS-2011 to other categories in KSS-2011 and to other PROMs including Forgotten Joint Score (FJS-12), EuroQol-5 Dimensions (EQ-5D) and 25-questions in Geriatric Locomotive Function Scale (GLFS-25). Material & Method. 83 patients over 65 years old with osteoarthritic knees were involved in this study. All patients underwent CR-TKAs (Persona CR. R. ). The means and ranges of demographics were as follows: age; 74.5 years old (65–89), Hip-Knee-Ankle (HKA) angle; 12.4 (−6.2–22.5) in varus. We asked patients to fulfill the questionnaire including KSS-2011, FJS-12, EQ-5D and GLFS-25 at 1-year postoperative follow-up visit. KSS-2011 consisted of 4 categories of questions; patient satisfaction (PS), symptoms, patient expectations (PE), functional activities (FA). We evaluated the correlation of PS to other PROMs using simple linear regression analyses (p<0.001). Results. The means and standard deviations of 1-year postoperative scores were as follows: PS; 28.5 ± 7.0, symptoms; 19.1 ± 4.3, PE; 11.2 ± 2.9, FA; 71.5 ± 16.6, FJS-12; 51.5 ± 18.6, EQ5D; 0.69 ± 0.10, GLFS-25; 25.7 ± 16.9. PSs were moderately positively correlated to other categories in KSS-2011(correlation coefficient (r): symptoms; 0.69, PE; 0.73, FA; 0.69). PSs were positively correlated to both FJS-12 and EQ5D (r: FJS-12; 0.72, EQ-5D; 0.67) and negatively correlated to GLFS-25(r; −0.74). Discussions. Patient satisfaction score positively correlated to the symptoms, patient
Total hip arthroplasty (THA) has high rates of patient satisfaction; however patient expectations for recreational and sporting activities are not always met. Our study aimed to identify preoperative factors that predict whether patient expectations for sporting or recreational activity are met 12 months following THA. Patient reported outcome measures (PROMs) were collected prospectively from 2015-2018 at one private hospital in Sydney. Age, gender, postcode, weight, and height were recorded preoperatively. Included participants underwent primary THA by one of the investigating surgeons. Univariable and multivariable analyses were performed with an
Patient expectations and their fulfilment are an important factor in determining patient-reported outcome and satisfaction of hip (THR) and knee replacement (TKR). The aim of this prospective cohort study was to examine the expectations of patients undergoing THR and TKR, and to identify differences in expectations, predictors of high expectations and the relationship between the fulfilment of expectations and patient-reported outcome measures. During the study period, patients who underwent 346 THRs and 323 TKRs completed an
Up to 20 percent of patients remain dissatisfied after primary total knee arthroplasty (TKA) surgery. Understanding the reasons for dissatisfaction post TKA may allow for better patient selection and optimized treatment for those who remain dissatisfied. The association between function, mobility and satisfaction are not well understood. The purpose of this study was to investigate the association between post-TKA satisfaction and i) pre-operative, ii) post-operative, and iii) change in knee joint function during gait. Thirty-one patients scheduled to receive primary TKA for knee osteoarthritis (OA) diagnosis were recruited and visited the Dynamics of Human Motion laboratory for instrumented walking gait analysis (using a synchronized NDI Optotrak motion capture system and AMTI force platforms in the walkway) at two time points, first within the week prior to their surgery, and second at approximately one year after surgery. At their post-operative visit, patients were asked to indicate their satisfaction with their knee prosthesis on a scale from zero to 100, with zero being totally unsatisfied and 100 being completely satisfied. Knee joint mechanics during gait at both time points were characterized by discriminant scores, the projection of their three-dimensional knee angles and moments during gait onto an existing discriminant model that was created to optimize separation of severe knee OA and healthy asymptomatic gait patterns. This discriminant model was created using data from 73 healthy participants and 73 with severe knee OA, and includes the magnitude and pattern features (captured with principal component analysis) of the knee adduction and flexion moment, and the magnitude of the knee flexion angle during gait. Larger discriminant scores indicate improved function toward healthy patterns, and smaller scores indicate more severe function. Associations between post-operative satisfaction and pre, post and change in discriminant scores were examined using Pearson correlation analyses. We also examined associations between satisfaction and pre-operative BMI, EQ5D and Oxford 12 scores, as well as changes in these scores from pre to post-TKA. Discriminant scores representing knee joint function during gait significantly improved on average after surgery (P =0.05). While overall knee joint function improved after primary TKA surgery, the amount of improvement in function was not reflected in post-operative patient satisfaction. However, the pre-operative function of the patient was negatively associated with satisfaction, indicating that patients with higher pre-operative function are overall less satisfied with their TKA surgery, regardless of any functional improvement due to the surgery. Interestingly, the only significant association with post-operative satisfaction was knee joint function, and the relationship between function and patient satisfaction following TKA appears to relate only to the baseline functional state of the patient, and not with functional improvement. This suggests that dissatisfaction post-surgery is more likely reflecting the unmet expectations of a higher functioning patient, and has implications for the need for improved understanding of pre-operative patient functional variability in TKA triage and
The discussion of outpatient unicompartmental knee arthroplasty (UKA) requires proof that it can be done safely and effectively, and also begs the question of whether it can be performed in an ambulatory surgery center (ASC) rather than a general hospital (which raises costs and is typically less efficient). Successful outpatient UKA requires carefully crafted algorithms/protocols, home support, preoperative planning and preparation,
A significant portion of ankle arthroplasty and ankle arthrodesis procedures performed in British Columbia are funded by the public medical services plan (MSP). However, some patients are treated privately through self-pay or by the workers compensation board (WCB), with the latter two groups being more likely to receive treatment sooner. The potential effect of payer on patient-reported outcomes and reoperation rates has not been previously explored. A retrospective chart review was performed using data from the Canadian Orthopaedic Foot and Ankle Society Prospective Ankle Reconstruction Database. N=443 patients (393 MSP, 26 self-pay, 24 WCB), treated with total ankle replacement or ankle arthrodesis by three subspecialty-trained surgeons in Vancouver from 1999–2003, were analyzed. Outcomes were compared, by payer, preoperatively and at long-term follow-up (6.3 years, range 2–14 years). Function was assessed using the Ankle Osteoarthritis Scale (AOS) Total score (primary outcome) and the AOS Pain and Difficulty subscores.
INTRODUCTION. Since the early 2000s, highly cross-linked (HXL) UHMWPE's have become a popular option with multiple experimental and clinical studies showing that gamma or electron radiation doses between 50–100kGY reduce wear and potentially extend the bearing life of UHMWPE. However, the increased wear resistance came at a compromise to mechanical properties due to the cross-linking process. Vitamin E has been added to some HXL UHMWPE materials to offer a solution to the compromise by increasing oxidation resistance and maintaining sufficient fatigue strength. However, limited data is available on the effect of the fabrication process, especially the method of irradiation, on the properties of the Vitamin E blended HXL UHMWPE. The purpose of this study was to evaluate the effects of adding the antioxidant vitamin E to highly crosslinked UHMWPE on wear rates. METHODS. Wear testing was performed on six highly crosslinked UHMWPE acetabular liners containing vitamin E (0.1% wt. alpha tocopherol) fabricated using the Cold Irradiation Mechanically Annealed (CIMA) process, initially cross-linked with approximately 100 kGy gamma irradiation, and terminally gamma sterilized. The liners were paired with three 40mm CoCr femoral heads and 40mm three ceramic femoral heads. Testing was completed per ASTM F1714 and ISO 14242 on an orbital hip joint wear simulator (Shore Western, California) and lubricated with 90% bovine calf serum, 20mM EDTA, 0.2% wt. NaN. 3. and DI water. A 1.1Hz Paul-type loading waveform with a peak of 2kN was used for a total of 5E6 wear cycles. Three loaded soak controls were used in parallel to adjust for fluid absorption. Samples were weighed every 5E5 wear cycles. RESULTS. The wear rates for the HXL blended vitamin-E liners were calculated using the slope of the linear regression over the steady state and resulted in a wear rate of 0.49mg/Mc. This is a decrease of approximately 95% compared to the 9.54 mg/Mc 28mm ID conventional UHMWPE wear rates as well as a notable difference for the other HXL UHMWPE liner wear rates discussed in the review. DISCUSSION. HXL blended vitamin-E 40mm liners demonstrated an approximate 95% reduction in wear rates compared to a 28mm ID conventional UHMWPE. The reduced wear rate confirmed the design
Introduction. Robotic systems have been used in TKA to add precision, although few studies have evaluated clinical outcomes. We report on early clinical results evaluating patient reported outcomes (PROs) on a series of robotic-assisted TKA (RAS-TKA) patients, and compare scores to those reported in the literature. Methods. We prospectively consented and enrolled 106 patients undergoing RAS-TKA by a single surgeon performing a measured-resection femur-first technique using a miniature bone-mounted robotic system. Patients completed a KOOS, New Knee Society Score (2011 KSS) and a Veterans RAND-12 (VR-12) pre-operatively and at 3, 6 and 12 months (M) post- operatively. At the time of publication 104, 101, and 78 patients had completed 3M, 6M, and 12M PROs, respectively. Changes in the five KOOS subscales (Pain, Symptoms, Activities of Daily Living (ADL), Sport and recreation function (Sport/Rec) and Knee-related Quality of Life (QOL)) were compared to available literature data from FORCE – TJR, a large, prospective, national cohort of TJR patients enrolled from diverse high-volume centers and community orthopaedic practices in the U.S, as well as to individual studies reporting on conventional (CON-TKA) and computer-assisted (CAS- TKA) at 3M, and on conventional TKA at 6M. The 2011 KSS is a validated method for quantifying patient's expectations and satisfaction with their TKA procedure. Improvements in the 2011 KSS were compared with literature data at 6M post-operatively. Results. RAS-TKA PRO's significantly improved at 3, 6, and 12M from pre-operative baseline values. When compared to the FORCE registry cohort data, the improvement in KOOS subscales were generally higher for RAS for pain at 6M, and for pain, ADL, and QOL at 1Y when compared with FORCE 2Y data. Higher improvements were also seen at 3M, except for Sports/Rec, and at 6M for symptoms and QOL when compared with smaller cohort studies. Improvements in 2011 KSS patient satisfaction and functional scores at 6M were 11 and 10 points greater than those reported for conventional TKA. A mean of 31 pts for the Patient Satisfaction score indicates that on average patients were ‘Satisfied’ with their knee function and pain level. Mean rates of dissatisfaction with knee pain level and function were 9.2%, 3.8% and 3.1% at 3, 6, and 12M postoperatively, respectively. A mean of 10pts for the
Patient perceptions regarding the functional outcomes and return to sports after shoulder replacement are often pessimistic, with many patients presenting for shoulder replacement surgery after months or years of avoiding the procedure so they could continue to live the current life they have, despite the increasing pain and dysfunction. Less common, but becoming more frequent, patients present with expectations that they will be able to return to all activities including heavy resistance training, cross-fit, rock climbing, and other strenuous overhead sports. In the past, little information has been available regarding the activities of shoulder arthroplasty patients after surgery. Typically, the boundaries have been set by the surgeon, with many patients cautioned or even prohibited from overhead sports, weight training, or heavy work responsibilities. A typical set of guidelines may include no repetitive overhead sports, except for recreational swimming, and no lifting over 20 pounds. Golf, jogging, hiking and other activities are allowed. The origin of these restricted guidelines and expectations is unknown, but many believe that since the results of shoulder replacements are less favorable in younger patients, it may be due to the overuse or abuse of the shoulder joint that is more typical at a younger age. Others have suggested that common sense prevails and that an artificial joint made of metal and plastic has a finite number of total movements and tolerance to resistance activities, and therefore keeping these activities at a minimum would extend the longevity of the artificial joint. None of these concepts are backed up by evidence-based literature, essentially reflecting the personal bias of the surgeons who care for patients with these problems. Despite all of the sophisticated research, scoring scales, outcome measures, and value-based metrics, the only outcome that really matters is whether the patient can return back to their normal way of life, at home, at work, during sport, or any activity that is important to them. Recent studies of patients who have had joint replacement surgery have revealed that our patients who participated in sports and work activities before surgery have a strong predilection to returning to those activities after successful shoulder replacement. The most common sports that shoulder arthroplasty patients enjoy including golf, swimming, tennis, but may also include many other choices including fitness activities, rowing, skiing, basketball, and softball. As expected, the return to these sports is less for reverse shoulder arthroplasty patients vs. anatomic shoulder arthroplasty patients. In a systematic review, more than 90% of anatomic shoulder replacement patients returned to sport, while 75% of reverse shoulder arthroplasty patients returned to some sporting activity. This may reflect the constraints of the reverse prosthesis, or, quite possibly reflect the typically older age and more sedentary lifestyle of patients who are indicated for reverse shoulder arthroplasty. In addition, if the patient had a preoperative
Total hip arthroplasty (THA) has been cited as one of the most successful surgical procedures performed today. However, as hip surgeons, we desire constantly improving outcomes for THA patients with more favorable complication rates. At the same time, patients desire hip pain relief and return to function with as little interruption of life as possible. The
Although many distal fit and fill design cementless stems have shown a very good long term stable fixation, short proximal coated stems are recently increasing in their use with an
Despite the successful, durable results, concern remains for using TKA in patients with isolated patello-femoral OA, as it requires an extensive surgical exposure and bone resection, a long recovery time, and a potentially more complex revision than that required for a patient with a failed patello-femoral arthroplasty (PFA). PFA was introduced in the late 1970s. While PFA was successful in providing pain relief, the procedure did not gain widespread use because of initial design limitations that predisposed to PF maltracking, catching, and subluxation. The mechanical complications associated with first-generation PFA offset the potential advantages of maintaining the knee's native soft tissues and spurred efforts to improve implant design, and to refine surgical techniques and patient selection. Over the past two decades, second generation PFAs incorporated changes in implant design and instrumentation and have shown promising results when used in the properly selected patient population. In addition, with improved instrumentation and robotics, adequate implant alignment and rotation can be achieved in the majority of patients, including those with severe patellofemoral dysplasia. Our meta-analysis of TKA and PFA for the treatment of isolated patello-femoral OA showed that the rate of complications of patients undergoing PFA was 30% after a median follow up of 5.3 years, which is significantly higher than the 7% rate of complications in patients who underwent TKA. The most frequent type of complication associated with PFA was mechanical (including loosening and instability), which is consistent with the malalignment and maltracking-related failures previously reported. The incidence of re-operation after PFA (21%) was significantly higher than that seen after TKA (2%). The most frequent indication for re-operation after PFA was mechanical failure (7%), followed by progression of OA (6%), and persistent pain or stiffness (5%). The most common re-operations after PFA were conversion to TKA, revision of PFA components, lateral releases, open or arthroscopic debridement, manipulations under anesthesia, and bony and/or soft tissue extensor mechanism re-alignment procedures. In our study, 11% of patients treated with PFA underwent a revision arthroplasty, with 4% undergoing revision PFA and 7% undergoing conversion to TKA. Our comparison of patients who were treated with second-generation PFA designs versus TKA showed no difference in the rate of complications, re-operation, or revision arthroplasty. Additionally, length of follow-up did not significantly influence any of these outcomes when comparing second-generation PFA and TKA. These observations provide support for the use of current PFA designs. The mechanical complications and subsequent re-operations that affected first-generation PFA designs appear to be of less concern with proper patient selection, meticulous surgical technique, current implant designs and peri-operative care. While it is difficult to predict the survivorship of current PFA designs, it is our
Background: Metal sensitivity following total joint arthroplasty (TJA) has been of increased concern, but the impact of a patient-reported metal allergy on clinical outcomes has not been investigated. The purpose of this study was to report the incidence and impact of patient-reported metal allergy following total knee (TKA) and total hip arthroplasty (THA). Methods: This was a retrospective, IRB-approved investigation of patients undergoing a primary, elective TJA between 2009 and 2011. All patients completed a pre-operative questionnaire asking about drug and environmental allergies. In January of 2010, a specific question was added regarding the presence of a metal allergy. UCLA Activity, SF-12, Modified Harris Hip (MHHS), and Knee Society (KSS) scores were collected pre-operatively and at most recent follow-up. Overall cohorts of metal allergy and non-metal allergy patients were compared and a 1:2 matching analysis was also performed. Results: 906 primary THAs and 589 primary TKAs were included. The incidence of patient-reported metal allergy was 1.7% before January 2010 and 4.0% after (overall 2.3% of THAs and 4.1% of TKAs). 97.8% of metal allergy patients were female. Following TKA, post-operative KSS function, symptoms, satisfaction, and
This study was performed to investigate the concentration of silver ions release up to a time of 9 weeks as well as the antimicrobial activity of silver sulfate and Nano-silver mixed bone cement on Candida albicans, in
Purpose. Total knee arthroplasty (TKA) is one of the most successful surgeries with respect to relieving pain and restoring function of the knee. However, some studies have reported that patients are not always satisfied with their results after TKA. The aim of this study was to determine which factors contribute to patient's satisfaction after TKA. Methods. We evaluated 69 patients who had undergone 76 primary TKAs between March 2012 and June 2013, and assessed patient- and physician- reported scores using the 2011 Knee Society Scoring System and clinical variables before and after TKAs. We determined the correlation between patient satisfaction and clinical variables. Results. The mean (SD) pre-operative score was 8.2 (4.9) for symptoms, 11.5 (4.5) for patient's satisfaction, 13.1 (2.2) for patient's expectations, and 35.4 (18.2) for functional activities. The mean (SD) post-operative score was 16.3 (5.0) for symptoms, 20.7 (6.4) for patient's satisfaction, 9.1 (2.3) for patient's expectations, and 47.4 (19.6) for functional activities. We found that physician- reported scores were higher than patient- reported scores, and improvement in patient- reported scores was lower than that of physician- reported scores following TKA. We did not found a correlation between any pre-operative variables including
Reverse shoulder arthroplasty (RSA) was released into the United States market in 2004 for the indication of Rotator Cuff Tear Arthropathy. Since that time the indications have widened and now include massive rotator cuff tears that are not deemed to be surgically repairable. This diagnosis includes patients that are considered young in terms of shoulder replacement surgery. These patients do not have the radiographic changes of arthropathy, but most have undergone multiple surgical procedures in the past to attempt to repair the rotator cuff deficiency. These younger patients have a different post-op
Recent reports observe that orthopaedic surgeons lack essential knowledge about ionising radiation. We aim to demonstrate perceived use of image-intensifiers by surgeons and awareness of radiation doses used during fractured neck of femur surgery. Surgeons at a regional trauma centre were sent an online questionnaire. They were shown two neck of femur fracture radiographs and asked the total number of images they would use to reduce and fix the fracture with a dynamic-hip-screw / inter-medullary nail respectively. They were asked the maximum safe radiation dose, and that of ‘hip pining’ compared to CXR as outlined by the Ionising Radiation Regulations 1999. For a DHS, consultants and registrars estimate their image use similarly. For IM nailing, consultants estimated higher image use than registrars, and double the number of X-rays taken for IM nailing compared to DHS. Knowledge levels regarding radiation doses during orthopaedic hip procedures are very low. There is an