Aims. Trauma & Orthopaedic (T&O) surgery has come under scrutiny for lagging behind other medical specialties in promoting gender and cultural equity and diversity within their workforce. The proportions of female, ethnic minority, and sexual and gender minority individuals within orthopaedic membership bodies are disproportionate to the populations they serve. The aim of this study is to report the findings of a national workforce survey of demographics and working patterns within T&O in Scotland. Methods. A questionnaire devised by a working group was delivered by the Client Analyst and Relationship Development (CARD) group. Utilizing a secure third party ensured anonymity for all respondents. Data were recorded and analyzed by the CARD group. Results. A total of 353 responses were recorded, representing 71% of the known workforce. Overall, 261 respondents (74%) identified as male, 85 (24%) female, and seven (2%) preferred not to say. For specialist trainee (ST)3 to ST6, 148 (42%) were female, and for ST7 to ST8, 131 (37%) were female. In total, 226 of all respondents (64%) were white-British, 35 (10%) were white-European, and 92 (26%) were of an ethnic minority background. A total of 321 of respondents (91%) identified as heterosexual, 14 (4%) preferred not to say, and 18 (5%) identified as LGBTQ+ or preferred to self-describe. Conclusion. This is the largest national workforce survey in contemporary surgical literature. The findings demonstrate a greater proportion of female surgeons overall compared to other studies in T&O. This proportion of females was highest among more junior trainees. The Scottish T&O workforce is more ethnically diverse than the demographics of the population it serves. This study suggests that T&O in Scotland is an evolving speciality in terms of
Aims. The aims of this study were to describe the demographic, socioeconomic, and educational factors associated with core surgical trainees (CSTs) who apply to and receive offers for higher surgical training (ST3) posts in Trauma & Orthopaedics (T&O). Methods. Data collected by the UK Medical Education Database (UKMED) between 1 January 2014 and 31 December 2019 were used in this retrospective longitudinal cohort study comprising 1,960 CSTs eligible for ST3. The primary outcome measures were whether CSTs applied for a T&O ST3 post and if they were subsequently offered a post. A directed acyclic graph was used for detecting confounders and adjusting logistic regression models to calculate odds ratios (ORs), which assessed the association between the primary outcomes and relevant exposures of interest, including: age, sex, ethnicity, parental socioeconomic status (SES), domiciliary status, category of medical school, Situational Judgement Test (SJT) scores at medical school, and success in postgraduate examinations. This study followed STROBE guidelines. Results. Compared to the overall cohort of CSTs, females were significantly less likely to apply to T&O (OR 0.37, 95% CI 0.30 to 0.46; n = 155/720 female vs n = 535/1,240 male; p < 0.001). CSTs who were not UK-domiciled prior to university were nearly twice as likely to apply to T&O (OR 1.99, 95% CI 1.39 to 2.85; n = 50/205 vs not UK-domiciled vs n = 585/1,580 UK-domiciled; p < 0.001). Age, ethnicity, SES, and medical school category were not associated with applying to T&O. Applicants who identified as ‘black and minority ethnic’ (BME) were significantly less likely to be offered a T&O ST3 post (OR 0.70, 95% CI 0.51 to 0.97; n = 165/265 BME vs n = 265/385 white; p = 0.034). Differences in age, sex, SES, medical school category, and SJT scores were not significantly associated with being offered a T&O ST3 post. Conclusion. There is an evident disparity in sex between T&O applicants and an ethnic disparity between those who receive offers on their first attempt. Further high-quality, prospective research in the post-COVID-19 pandemic period is needed to improve
Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length
Mortality following revision hip surgery for periprosthetic fracture (PPF) has been reported to be as high as 60% at 5 years. The aim of this study was to determine the mortality rate for PPF revisions, compared to revision for aseptic loosening or infection at our tertiary referral centre. Revision arthroplasty procedures performed for PPF, aseptic loosening or infection between January 2014 and December 2015 at our institution were identified using a prospectively collected PPF referral database and locally collected NJR data. Comparisons were made between the 3 groups for baseline demographics, admission to higher-level care, length of stay, complications, and Kaplan-Meier failure (mortality) at 1 & 5 years post-operative (with log-rank test for equality). There were 37 PPF, 71 infected and 221 aseptic revisions. PPF had a higher proportion of females (65% vs. 39% in infection and 53% in aseptic; p = 0.031) and grade 3 and 4 ASA patients (p = 0.006). Median time to surgery from injury for PPF was 8 days (95% CI, 6–16). Single-stage procedures were performed in 84% of PPF, 42% of infection and 99% of aseptic revisions (p < 0.001). 19% of PPF revisions required HDU admission, 1% in the aseptic group and none in the infection group (p<0.001). Median length of stay was significantly different (PPF 10; infection 14; aseptic 8 days (p < 0.001). The Kaplan-Meier estimate of 1-year mortality were: PPF = 0%; infection = 2.8% (0.7–11.1%); aseptic = 0.9% (0.2–3.5%). 5-year mortality estimates were: PPF = 17.1% (8–34%), infection = 8.7% (4–18.3%), aseptic = 12% (8.4–17%). Log-rank test of
Introduction:. The robot-assisted cementless total hip arthroplasty has theoretical advantages of providing better fit and mechanical stability of the stem. However, no previous study has been reported on a short stem implantation using surgical robot. We compared early clinical and radiographic results between robotic milling and manual rasping in short stem total hip arthroplasty. Materials & Methods:. We designed a prospective randomized controlled trial to determine whether robot-assisted short stem total hip arthroplasty improves the implant position represented by stem alignment, leg length
Introduction. Historically, amputation or rotationplasty were the treatment of choice in skeletally immature patients. The introduction of expandable endoprostheses in the late 1980s offered the advantages of limb-salvage and limb length
Introduction. There is no consensus on the ideal pain management strategy following total hip arthroplasty (THA). This study sought to identify immediate changes in the hospital course of patients undergoing primary THA following implementation of a rapid recovery anesthesia and multimodal management of pain (RAMP) protocol. For this study, rapid recovery anesthesia describes the use of preoperative non-narcotic medication in conjunction with neuraxial anesthesia techniques confined to the operating room only. The multimodal pain regimen consists of pre- and post-operative high dose nonsteroidal anti-inflammatories (NSAIDs), gabapentin, and antiemetics with or without intraoperative periarticular anesthetic injection. We hypothesized that the implementation of a RAMP protocol would lead to decreased reported pain scores, decreased narcotic use, and a shorter hospital stay in patients undergoing primary THA. Methods. This retrospective cohort study performed at a multi-surgeon high-volume institution reviewed the records of 81 consecutive patients who underwent primary THA utilizing traditional anesthesia and an opioid-dependentpain management techniques between June to September 2014 compared to 78 patients who underwent primary THA after implementation of the RAMP protocol between November 2014 to February 2015. The length of stay (LOS), pain scores, narcotic use, and other clinical data were recorded for each study group.
INTRODUCTION. Use of a novel ligament gap balancing instrumentation system in total knee arthroplasty (TKA) resulted in femoral component external rotation values which were higher on average, compared to measured bone resection systems. In one hundred twenty knees in 110 patients the external rotation averaged 6.9 degrees (± 2.8) and ranged from 0.6 to 12.8 degrees. The external rotation values in this study were 4° and 2° larger, respectively, than the typical 3° and 5° discrete values that are common to measured resection systems. The purpose of the present study was to determine the effect of these greater external rotation values for the femoral component on patellar tracking, flexion stability and function of two different TKA implant designs. METHODS. In the first arm of the study, 120 knees in 110 patients were consecutively enrolled by a single surgeon using the same implant design (single radius femur with a medial constraint tibial liner) across subjects. All patients underwent arthroplasty with tibial resection first and that set external rotation of the femoral component based upon use of a ligament gap balancing system. Following ligament tensioning / balancing, the femur was prepared. The accuracy of the ligament balancing system was assessed by reapplying equal tension to the ligaments using a tensioning bolt and torque wrench in flexion and extension after the bone resections had been made. The resulting flexion and extension gaps were then measured to determine rectangular shape and
Introduction. Paediatric tibial fractures, unlike femoral fractures do not have much potential for overgrowth. In simple factures of the tibial shaft treated non-operatively the major problems are shortening and malunion. In complex injuries with extensive soft tissue disruption and bone loss, the long-term aim of reconstruction is to achieve union with a fully functional limb without limb-length inequality. Methods. Four children (Age range 6-12 years) who sustained high-energy grade III open fractures of the tibia were treated with acute shortening and bone transport. Any soft tissue reconstructive and secondary grafting procedures for delayed union were recorded. The children were prospectively followed up to fracture union. Distraction ostegenesis proceeded until limb length
Introduction: Paediatric tibial fractures, unlike femoral fractures do not have much potential for overgrowth. In simple factures of the tibial shaft treated non-operatively the major problems are shortening and malunion. In complex injuries with extensive soft tissue disruption and bone loss, the long-term aim of reconstruction is to achieve union with a fully functional limb without limb-length inequality. Methods: Four children who sustained high-energy grade III open fractures of the tibia were treated with acute shortening and bone transport. Any soft tissue reconstructive and secondary grafting procedures for delayed union were recorded. The children were prospectively followed up to fracture union. Distraction ostegenesis proceeded until limb length
INTRODUCTION. Use of a novel ligament gap balancing instrumentation system in total knee arthroplasty resulted in femoral component external rotation values which were higher on average, compared to measured resection systems. In one hundred twenty knees in 110 patients the external rotation averaged 6.9 degrees (+/− 2.8) and ranged from 0.6 to 12.8 degrees. The external rotation values in this study were 4° and 2° larger, respectively, than the typical 3° and 5° discrete values that are common to measured resection systems. The purpose of the present study was to determine the effect of these greater external rotation values for the femoral component on patellar tracking and flexion instability. METHODS. One hundred twenty knees in 110 patients were consecutively enrolled by a single surgeon using the same implant across subjects. All patients underwent arthroplasty with tibial resection first and that set external rotation of the femoral component based upon use of a ligament gap balancing system. Following ligament tensioning/balancing, the femur was prepared. The accuracy of the ligament balancing system was assessed by reapplying equal tension to the ligaments using a tensioning bolt and torque wrench in flexion and extension after the bone resections had been made. The resulting flexion and extension gaps were then measured to determine rectangular shape and
Congenital talipes equinovarus (CTEV), also known as club foot or talipes is a common congenital disorder. Parents are using the Internet more and more as a source of information about health care. Unfortunately, the quality of health care information on the Internet varies. This study looked at information available to parents using two instruments for judging the
Placement of total knee arthroplasty components is typically controlled via resections that reference bony landmarks. For example, external rotation of the femoral component can be pre-determined by referencing the posterior condyles or the epicondylar axis. Such approaches exclude consideration of any potential effect of the collateral ligaments before resection are made. In addition, bone referencing instrumentation usually limits femoral component placement to discrete values of external rotation such as 3° or 5°. The purpose of the present study was to determine external rotation of the femoral component following use of a novel ligament balancing approach and to assess the accuracy of balancing the flexion and extension gaps with this ligament balancing system. One hundred twenty knees in 110 patients were consecutively enrolled by a single surgeon using the same implant across subjects. All patients underwent arthroplasty that set external rotation of the femoral component based upon use of a novel ligament balancing system. Following ligament tensioning/balancing, the femur was prepared. Thicknesses of the medial and lateral posterior condylar resections were measured and the difference between the two measurements was calculated. When placed into relation with the line formed by the distance between the midpoints of the distal condyles (reference line), the difference in the condylar resections gives the height of a right triangle. The arc tangent function was then used to calculate the resultant angle (external rotation) formed from the reference line and the hypotenuse. The average, range and standard deviation of the external rotation values was found. External rotation averaged 6.9° (+/−2.8°) and ranged from 0.6° to 12.8°. Fifty-four percent of femoral components were sized 3, 4 or 5. The external rotation values in this study were 4° and 2° larger, respectively, than the typical 3° and 5° discrete values that are common to measured resection systems. External rotation values are higher on average, when ligament tensioning/balancing is employed with this novel system compared to measured resection systems. Also, the standard deviation and range suggests that true femoral rotation varies greatly between patients. This finding suggests that limiting the surgeon to discrete rotation values may be at odds with where the femur “desires” to be, given soft tissue considerations for each patient. Future work includes determining whether there is a functional difference between measured resection and this ligament tensioning/balancing approach. The accuracy of the ligament balancing system was assessed by applying equal tension on the ligaments using a tensioning bolt and torque wrench in flexion and extension after the bone resections had been made. The resulting flexion and extension gaps were then measured to determine rectangular shape and
Survivors of infantile meningococcal septicaemia often develop progressive skeletal deformity as a result of physeal damage at many sites, particularly in the lower limb. Distal tibial physeal arrest typically occurs with sparing of the distal fibular physis leading to a rapidly progressive varus deformity. There have been reports of isolated cases of this deformity, but to our knowledge there have been no papers which specifically describe the development of the deformity and the options for treatment. Surgery to correct this deformity is complex because of the patient’s age, previous scarring and the multiplanar nature of the deformity. The surgical goal is to restore leg-length
The technique involves inserting the femoral and acetabular components anterior to the posterior capsule and short rotators and posterior to the gluteus medius and minimus through an incision in the superior capsule. The surgery is performed with the femoral component instrumented before femoral neck osteotomy and head removal. The femur remains steady during the femoral instrumentation. Leverage retractors around the neck are easy to hold and to maintain exposure. The integrity of the capsule is used to assess length and offset. During the procedure the hip is never disarticulated, and the leg is never placed outside of the range of motion envelope of the normal hip. The technique has found astonishingly few users over the past ten years. Many surgeons are not aware of this technique and clinical results are scarce. The purpose of this paper is recall it to memory, to compare it with other less invasive procedures, and to report on some remarkable clinical results including stability, leg length and offset
There is enough evidence to show that navigation improves precision of component placement and consistent and accurate restoration of limb alignment, allowing the surgeon to achieve the desired neutral or kinematic alignment. Computer-assisted TKA provides excellent information regarding gap
Background. Humeral retroversion is variable among individuals, and there are several measurement methods. This study was conducted to compare the concordance and reliability between the standard method and 5 other measurement methods on Twodimensional (2D) computed tomography (CT) scans. Methods. CT scans from 21 patients who underwent shoulder arthroplasty (19 women and 2 men; mean age, 70.1 years [range, 42 to 81 years]) were analyzed. The elbow transepicondylar axis was used as a distal reference. Proximal reference points included the central humeral head axis (standard method), the axis of the humeral center to 9 mm posterior to the posterior margin of the bicipital groove (method 1), the central axis of the bicipital groove –30° (method 2), the base axis of the triangular shaped metaphysis +2.5° (method 3), the distal humeral head central axis +2.4° (method 4), and contralateral humeral head retroversion (method 5). Measurements were conducted independently by two orthopedic surgeons. Results. The mean humeral retroversion was 31.42° ± 12.10° using the standard method, and 29.70° ± 11.66° (method 1), 30.64°± 11.24° (method 2), 30.41° ± 11.17° (method 3), 32.14° ± 11.70° (method 4), and 34.15° ± 11.47° (method 5) for the other methods. Interobserver reliability and intraobserver reliability exceeded 0.75 for all methods. On the test to evaluate the
The outcome of total hip replacement (THR) is potentially affected by the body mass index (BMI) of the patient. We studied the outcome of 2026 consecutive primary cementless THRs performed for osteoarthritis. The mean follow-up was 6.3 years (0 to 11.71) and no patient was lost to follow-up for survival analysis. The patients were divided into two groups according to their BMI as follows: non-obese (BMI <
30 kg/m. 2. ) and obese (BMI ≥ 30 kg/m. 2. ). The obese patient undergoing surgery was found to be significantly younger (p <
0.001). The log-rank test for
We describe the application of a non-invasive extendible endoprosthetic replacement in skeletally-mature patients undergoing revision for failed joint replacement with resultant limb-length inequality after malignant or non-malignant disease. This prosthesis was developed for tumour surgery in skeletally-immature patients but has now been adapted for use in revision procedures to reconstruct the joint or facilitate an arthrodesis, replace bony defects and allow limb length to be restored gradually in the post-operative period. We record the short-term results in nine patients who have had this procedure after multiple previous reconstructive operations. In six, the initial reconstruction had been performed with either allograft or endoprosthetic replacement for neoplastic disease and in three for non-neoplastic disease. The essential components of the prosthesis are a magnetic disc, a gearbox and a drive screw which allows painless lengthening of the prosthesis using the principle of electromagnetic induction. The mean age of the patients was 37 years (18 to 68) with a mean follow-up of 34 months (12 to 62). They had previously undergone a mean of six (2 to 14) open procedures on the affected limb before revision with the non-invasive extendible endoprosthesis. The mean length gained was 56 mm (19 to 107) requiring a mean of nine (3 to 20) lengthening episodes performed in the outpatient department. There was one case of recurrent infection after revision of a previously infected implant and one fracture of the prosthesis after a fall. No amputations were performed. Planned exchange of the prosthesis was required in three patients after attainment of the maximum lengthening capacity of the implant. There was no failure of the lengthening mechanism. The Mean Musculoskeletal Tumour Society rating score was 22 of 30 available points (18 to 28). The use of a non-invasive extendible endoprosthesis in this manner provided patients with good functional results and restoration of leg-length