Introduction. Simultaneous correction of knee varus malalignment with medial open wedge high tibial osteotomy (MOWHTO) combined with anterior cruciate ligament (ACL) surgery aims to address symptomatic unicompartmental osteoarthritis in addition to restore knee stability in order to improve outcomes. The aim of this study is to present at least 5 years results of 32 patients who underwent simultaneous knee realignment osteotomy with ACL surgery. Methods. Patients with symptomatic instability due to chronic ACL deficiency or failed previous ACL surgery together with a varus malalignment of ≥6°, previous medial meniscectomy and symptomatic medial compartment pain who were treated with MOWHTO combined with ACL surgery were enrolled. ACL surgery was performed with the anatomical single bundle all-inside technique using TightRope. ®. RT (Arthrex, Naples, FL, USA) and MOWHTO using TomoFix. ®. medial high tibia plate (DePuy Synthes, Raynham, MA, USA) in all cases. Patients were evaluated preoperatively and at 6 months, 12 months and annually postoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Oxford Knee Score (OKS) and Euroqol's Visual Analogue Score (VAS) for pain. Results. 32 patients (22 men and 10 women) with a mean age of 41.2 years and mean BMI of 28.6 kg/m. 2. , underwent the combined procedures. Tibiofemoral neutral re-alignment was achieved in all patients with HTO. Complete subjective and objective scores have been obtained in 84.4% of patients with at least 5 years of follow-up (mean 8.7 years). An improvement in total KOOS of 27.1 points (p<0.003), OKS of 15.1 (p<0.003) and VAS for pain of 24.7 points (p<0.001) were detected. No ACL reconstruction failure was noted. Complications consisted of one superficial wound infection and one delayed union. Plate removal was needed in 20 (62.5%) patients due to pes anserinus pain. Conclusions. Simultaneous restoration of coronal knee axis by applying HTO and stability by ACL reconstruction/revision were reported to offer excellent improvement in
Autologous micro-fragmented adipose tissue (MFAT) for the treatment of symptomatic knee osteoarthritis (OA) is gaining interest although there is still a lack of supportive data on safety and clinical efficacy. This study primarily aimed to identify patient- and pathology-related parameters to tighten patient selection criteria for future clinical MFAT application. Secondly, the overall (1) therapeutic response rate (TRR), (2) short-term clinical effect, (3) effect durability and (4) therapeutic safety was investigated at a minimal follow-up of 1 year. Sixty-four subjects (91 knees) with symptomatic knee OA (mild-severe on MRI) were enrolled in a prospective single-centre case series. Ethical approval was obtained from the local and academic ethical committee (#B300201733775). After liposuction, the adipose tissue was mechanically processed in a Lipogem® device which eventually produced 6–9cc MFAT. Subjects were clinically assessed by means of the KOOS, NRS, UCLA and EQ-5D at baseline and 1, 3, 6 and 12 months after injection. Adverse events were meticulously recorded. The TRR was defined according to the OMERACT-OARSI criteria. A baseline MRI was scored following the MOAKS system. Paired sample t-tests, independent t-test and Fischer's exact test were applied on appropriate variables. Multiple regression models were fit separately for patient-and pathology-specific factors. Significance level was set at α=0.05. The overall TRR was 66% at 3 months and 50% at 12 months after injection. Subgroup analysis revealed that specifically patients with no-mild bone marrow lesions (BML) had a TRR of 88% at 3 months and 75% at 12 months after MFAT injection. Therapy responders at these timepoints improved with 29.3±14.1 points and 30.8±15.3 points on KOOS pain, while non-responders deteriorated mildly. All clinical scores were significantly higher at follow-up compared to baseline (p<0.05). BMI (factor 0.17, p=0.002) and age (factor −0.48, p=0.048) were prognosticators for the TRR% at 1 month and for absolute KOOS pain improvement at 6 months, respectively. Posterior horn lesions (PHL) in the medial meniscus (p<0.001) and bone marrow lesions (p=0.003) were negative prognosticators for the TRR at respectively 6 and 12 months post-injection. An inflammatory reaction (pain, swelling or stiffness) to MFAT was reported in 79% knees and resolved spontaneously within 16.6±13.5 days after administration. The study showed a durable and satisfying TRR (up to 75% at 1 year in selected patients without BML) and clinical improvement after a single intra-articular injection with autologous MFAT. The availability of an index knee MRI is mandatory to select MFAT patients, preferably with no or mild BML and without PHL of the medial meniscus. High BMI and younger age are associated with better
The use of a tourniquet during total knee arthroplasty (TKA) is controversial. Return to function and pain are believed to be affected by the use of a tourniquet. The hypothesis of this study was that use of a tourniquet (T) would delay postoperative functional recovery and increase pain as compared to no tourniquet use (NT). 200 patients were recruited for this prospective, double-blinded, randomized controlled trial. All surgeries were performed by one of two fellowship trained arthroplasty surgeons at our institution. Patients were randomized to either undergo TKA with T or NT and blinded to group allocation. An otherwise standardized perioperative protocol was followed. The primary outcome measures were functional assessment testing using the timed up-and-go (TUG) and stair-climb (SC) tests and visual analog scale pain (VAS-P) scores. Secondary outcome measures included blood loss and range-of-motion (ROM). Patients completed outcomes measures preoperatively, in hospital, and postoperatively at 4–6 weeks and 6–8 months. Minimal detectable change (MDC) and Student's T-test, alpha of p < 0.05, were used to determine significance. No significant differences were seen in postoperative TUG, SC, VAS-P, or ROM at any time point. NT patients were seen to have significantly more calculated blood loss (means: T 1,370.04mL, NT 1,743.85mL; p < 0.001), without a significant increase in transfusion events. Tourniquet use during TKA significantly decreases blood loss and does not adversely affect
The study looked at
Financial and human cost effectiveness is an increasing evident outcome measure of surgical innovation. Considering the human element, the aim is to restore the individual to their “normal” state by sparing anatomy without compromising implant performance. Gait lab studies have shown differences between different implants at top walking speed, but none to our knowledge have analysed differing total hip replacement patients through the entire range of gait speed and incline to show differences. The purpose of this gait study was to 1) determine if a new short stem femoral implant would return patients back to normal 2) compare its performance to established hip resurfacing and long stem total hip replacement (THR) implants. 110 subjects were tested on an instrumented treadmill (Kistler Gaitway, Amherst, NY), 4 groups (short-stem THR, long-stem THR, hip resurfacing and healthy controls) of 28, 29, 27, and 26 respectively. The new short femoral stem patients (Furlong Evolution, JRI) were taken from the ongoing Evolution Hip trial that have been tested on the treadmill with minimum 12months postop. The long stem total hip replacements and hip resurfacing groups were identified from out 800 patient gait database. They were only chosen if they were 12 months postop and had no other joint disease or medical comorbidities which would affect gait performance. All subjects were tested through their entire range of gait speeds and incline after having a 5 minute habituation period. Speed intervals were at 0.5kms increments until maximum walking speed achieved and inclines at 4kms for 5, 10, 15%. At all incremental intervals of speed, the vertical component of the ground reaction forces, center of pressure and temporal measurements were collected for both limbs with a sampling frequency of 100Hz. Body weight scaling was applied to correct for mass differences and a symmetry index to compare the implanted hip to the contralateral normal hip. All variables for each subject group were compared to each other using an analysis of variance (ANOVA) with Tukey post hoc test with significance set at α=0.05. The four experimental groups were reasonably matched for demographics and the implant groups for PROMs. Hip resurfacing had a clear top walking speed advantage, but when assessing the symmetry index on all speeds and incline, all groups were not significantly different. Push-off and step length was statistically less favourable for the short/long THR group (p=0.005–0.05) depending on speed/incline. The primary aim of this study was determine if implant design affected gait symmetry and performance. Interestingly, irrespective of implant design, symmetry with regards to weight acceptance, impulse, push-off and step length was returned to normal when comparing to healthy controls. However individual implant performance on the flat and incline, showed inferior (p<0.05) push-off force and step length in the short stem and long stem THR groups when compared to controls. Age and gender may have played a part for the short stem group. It appears that the