The Oxford medial unicompartmental knee replacement has been shown to provide good long-tern results in numerous studies with survivorship at 10 years ranging from 82% to 100%. This prospective study describes the survival of 265 Oxford unicompartmental knee replacements implanted in one centre from 1995-2009. 8 were lost to follow up. 40 of the 265 knees were revised. For operation performed from1995-1999 the risk of revision at 5 years was 10%, operations from 2000-2004 the risk of revision was 15% and from 2005-2009 the risk of revision at 5 years was 36%. This study demonstrates that since 2005 there has been a significant increase in
Background. A number of studies have reported on the
Hip resurfacing arthroplasty is an established and effective intervention for osteoarthritis of the hip in the young active patient, relying on the principle of femoral bone-stock preservation. A recognised mode of failure is neck thinning leading to radiological evidence of neck collapse and clinical failure. We report on a series of these slow-neck-failure patients and highlight the increased incidence of this phenomenon in post-menopausal female patients. This is a single operator, single implant series; 172 cases were identified from databases at our institution. 76 were female, mean (SD) age 52 (7) years. 96 were male, mean (SD) age 51(12) years. 15 (8.7%) patients required revision. 12 (80%) were female, 9 (75%) of these were due to slow neck failure. In the men one patient developed ALVAL requiring removal of his bilateral hip resurfacings, the other failure mode was
Component malalignment has long been implicated in poor implant survival in Total Knee Arthroplasty (TKA). Malalignment can occur in orientation of bony cuts, and in component cementation/implantation. Several systems exist to aid bony cut alignment (navigation, shape matching), but final implantation technique is common to all TKA. Correction of errors in bony cut alignment at cementation/implantation by surgeons has been described. Changes in alignment at this stage are likely to result in asymmetrical cement penetration, which is implicated in
Distal clavicle fractures have a significant non-union rate, and are often managed operatively. Many of the fixation devices used have a high complication rate or require removal. An arthroscopic technique using the Tightrope device (Arthrex) has been used in our institution. We aimed to describe our initial results. Eighteen cases were identified retrospectively, and the notes and radiographs reviewed. Twelve patients were male, six female, with mean age 33 years. All fractures were displaced, lateral to the coraco-clavicular ligament complex: six showed marked comminution. Mean follow-up was thirteen weeks. Fifteen fractures united, with a mean radiological time to union of 8 weeks (range 6-13 weeks). There were three surgical complications. In one, the clavicular button was not seated correctly on bone, and
The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.Aims
Methods
Background. Pseudotumours have been associated with metal-on-metal (MoM) hip replacements. We define it as a solid mass which may have cystic components that is neither neoplastic nor infectious in aetiology. The cause of a pseudotumour is not fully understood but could be due to excessive wear, metal hypersensitivity or due to an as-yet unknown cause. Aim. We present the retrieval analysis of
Background. Metal on metal hip resurfacing has become popular worldwide for younger patients because of perceived advantages in function and ease of revision, due to bone conservation. Joint Registry data have shown increased risk of
In a prospective, randomised trial, we compared the use of three Ullevaal hip screws with that of two Hansson hook-pins in 278 patients with fractures of the femoral neck. Background factors were similar in both groups. Follow-up was for two years. There were no significant differences between the groups in length of time of surgery, hospital stay, general complications, mortality, pain or walking ability. Likewise, the rates of
The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded.Aims
Methods
Introduction. Femorotibial malalignment exceeding ±3° is a recognised contributor of
Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population. This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit
The aims of this study were to determine the cumulative ten-year
survivorship of hips treated for acetabular fractures using surgical
hip dislocation and to identify factors predictive of an unfavourable
outcome. We followed up 60 consecutive patients (61 hips; mean age 36.3
years, standard deviation (Aims
Patients and Methods
Radiological evidence of post-traumatic osteoarthritis
(PTOA) after fracture of the tibial plateau is common but end-stage arthritis
which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and
outcomes of, total knee arthroplasty after fracture of the tibial
plateau and to compare this with an age and gender-matched cohort
of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight
men) with a mean age of 65 years (40 to 89) underwent TKA at a mean
of 24 months (2 to 124) after a fracture of the tibial plateau.
Of these, 24 had undergone ORIF and seven had been treated non-operatively.
Patients were assessed pre-operatively and at 6, 12 and >
60 months
using the Short Form-12, Oxford Knee Score and a patient satisfaction
score. Patients with instability or nonunion needed total knee arthroplasty
earlier (14 and 13.3 months post-injury) than those with intra-articular
malunion (50 months, p <
0.001). Primary cruciate-retaining implants
were used in 27 (87%) patients. Complication rates were higher in
the PTOA cohort and included wound complications (13% Total knee arthroplasty undertaken after fracture of the tibial
plateau has a higher rate of complications than that undertaken
for primary osteoarthritis, but patient-reported outcomes and satisfaction
are comparable. Cite this article:
Early total hip replacement (THR) for acetabular
fractures offers accelerated rehabilitation, but a high risk of heterotopic
ossification (HO) has been reported. The purpose of this study was
to evaluate the incidence of HO, its associated risk factors and
functional impact. A total of 40 patients with acetabular fractures
treated with a THR weres retrospectively reviewed. The incidence
and severity of HO were evaluated using the modified Brooker classification,
and the functional outcome assessed. The overall incidence of HO
was 38%
(n = 15), with nine severe grade III cases. Patients who underwent
surgery early after injury had a fourfold increased chance of developing
HO. The mean blood loss and operating time were more than twice
that of those whose surgery was delayed (p = 0.002 and p <
0.001,
respectively). In those undergoing early THR, the incidence of grade
III HO was eight times higher than in those in whom THR was delayed
(p = 0.01). Only three of the seven patients with severe HO showed
good or excellent Harris hip scores compared with eight of nine
with class 0, I or II HO (p = 0.049). Associated musculoskeletal
injuries, high-energy trauma and head injuries were associated with
the development of grade III HO. The incidence of HO was significantly higher in patients with
a displaced acetabular fracture undergoing THR early compared with
those undergoing THR later and this had an adverse effect on the
functional outcome. Cite this article:
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
In a series of 450 patients over 70 years of age with displaced fractures of the femoral neck sustained between 1995 and 1997 treatment was randomised either to internal fixation or replacement. Depending on age and level of activity the latter was either a total hip replacement or a hemiarthroplasty. Patients who were confused or bed-ridden were excluded, as were those with rheumatoid arthritis. At ten years there were 99 failures (45.6%) after internal fixation compared with 17 (8.8%) after replacement. The rate of mortality was high at 75% at ten years, and was the same in both groups at all times. Patient-reported pain and function were similar in both groups at five and ten years. Those with successfully healed fractures had more hip pain and reduction of mobility at four months compared with patients with an uncomplicated replacement, and they never attained a better outcome than the latter patients regarding pain or function. Primary replacement gave reliable long-term results in patients with a displaced fracture of the femoral neck.
Using a prospective database of 1309 displaced acetabular fractures gathered between 1980 and 2007, we calculated the annual mean age and annual incidence of elderly patients >
60 years of age presenting with these injuries. We compared the clinical details and patterns of fracture between patients >
60 years of age (study group) with those <
60 years (control group). We performed a detailed evaluation of the radiographs of the older group to determine the incidence of radiological characteristics which have been previously described as being associated with a poor patient outcome. In all, 235 patients were >
60 years of age and the remaining 1074 were <
60 years. The incidence of elderly patients with acetabular fractures increased by 2.4-fold between the first half of the study period and the second half (10% (62) The proportion of elderly patients presenting with acetabular fractures increased during the 27-year period. The older patients had a different distribution of fracture pattern than the younger patients, and often had radiological features which have been shown in other studies to be predictive of a poor outcome.
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed. At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.