Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 120 - 120
4 Apr 2023
Joumah A Cowling P
Full Access

Though retear rates following rotator cuff repair are well established, we set out to review current literature to determine when early retears occurred (defined as <12m following surgery), and examine which pre- and post-operative variables might affect outcome.

Pubmed, Medline, and CINAHL were searched for literature published from 2011 to 2021 using specific search terms. The inclusion criteria were studies reporting retear rates within 12 months of initial surgical repair. Exclusionary criteria were studies that included partial thickness tears, and studies that did not use imaging modalities within 12 months to assess for retears. PRISMA guidelines were followed, identifying a total of 10 papers.

A combined total of 3372 shoulders included (Mean age 56 −67 years). The most common modality used to identify early retears were ultrasound scan and MRI. 6 of the 10 studies completed imaging at 0-3 months, 6 studies imaged at 3-6 months and 6 studies imaged at 6-12 months. Across all studies, there was a 17% early retear rate (574 patients). Of these, 13% occurred by 3 months, whilst the peak for retears occurred at 3-6 months (82%) and 5% occurred at 6-12 months. The risk of retear was higher in larger tears and extensive tendon degeneration. All studies apart from one documented a return to work/sport at 6 months post-operatively. Postoperative rehabilitation does not appear to alter retear rate, although data is limited with only 1 of 10 studies allowing active range of movement before 6 weeks. Retorn tendons had poorer functional outcomes compared to intact tendons at 12m following initial repair.

The majority of early retears occur at 3-6 months and this time period should be prioritised both in rehabilitation protocols and future research. Age, tear size, and tendon degeneration were found to influence likelihood of early retears.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 91 - 91
1 Aug 2012
Joyce T Lord J Langton D Nargol A
Full Access

Introduction. Total hip prostheses which use a ceramic head within a metal liner are a relatively recent introduction. As such, survivorship rates from independent centres alongside explant analysis are rare. The early experience with this novel ceramic-on-metal (CoM) bearing couple is reported. Methods and Materials. All CoM hips implanted between 2008 and 2009 at a single hospital by a single surgeon were reviewed. Radiographs were analysed using EBRA software to determine acetabular cup inclination and anteversion angles. Blood metal ion concentrations were measured using inductively coupled plasma mass spectroscopy (ICPMS). Explants were measured for bearing surface and taper wear using a high precision co-ordinate measuring machine. The roughness of the articulating surfaces was measured with a non-contact profilometer. Results. In 54 patients 56 CoM hips were implanted. Mean (range) age was 64 years (34-87). There were 41 females and 15 males. Patients were followed-up for a mean of 1.5 years. Three hips were revised at mean of 1.2 years (2 female, 1 male) with a further 3 listed for revision under 1.5 years giving an overall failure rate of 10.7%. All these patients reported with pain. X-rays of failed devices showed a characteristic pattern of femoral stem loosening. Serum cobalt and chromium were less than 2 micrograms/L. Explant analysis of the three revised hips showed wear at the liner rim in each case. In two of these cases the wear extended completely around the circumference. The wear volumes were 4.1, 2.0 and 2.3mm3 respectively. The ceramic heads were unworn but some transfer of metal could be seen visually. There was no significant wear or deformation at the taper junctions. Typical ceramic head roughness values were 3nm Ra and so most of the surface area of the heads remained in a pristine condition. Discussion. The very high early failure rate using COM is concerning. Explant analysis suggests equatorial contacts with propagation of high frictional forces distally. These forces may have caused early loosening of the femoral stems. Orthopaedic surgeons need to be aware of this new mechanism of failure which is associated with low metal ions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 19 - 19
2 Jan 2024
Li R Zheng J Smith P Chen X
Full Access

Device-associated bacterial infections are a major and costly clinical challenge. This project aimed to develop a smart new biomaterial for implants that helps to protect against infection and inflammation, promote bone growth, and is biodegradable. Gallium (Ga) doped strontium-phosphate was coated on pure Magnesium (Mg) through a chemical conversion process. Mg was distributed in a graduated manner throughout the strontium-phosphate coating GaSrPO4, with a compact structure and a Ga-rich surface. We tested this sample for its biocompatibility, effects on bone remodeling and antibacterial activities including Staphylococcus aureus, S. epidermidis and E. coli - key strains causing infection and early failure of the surgical implantations in orthopaedics and trauma. Ga was distributed in a gradient way throughout the entire strontium-phosphate coating with a compact structure and a gallium-rich surface. The GaSrPO4 coating protected the underlying Mg from substantial degradation in minimal essential media at physiological conditions over 9 days. The liberated Ga ions from the coatings upon Mg specimens inhibited the growth of bacterial tested. The Ga dopants showed minimal interferences with the SrPO4 based coating, which boosted osteoblasts and undermined osteoclasts in in vitro co-cultures model. The results evidenced this new material may be further translated to preclinical trial in large animal model and towards clinical trial. Acknowledgements: Authors are grateful to the financial support from the Australian Research Council through the Linkage Scheme (ARC LP150100343). The authors acknowledge the facilities, and the scientific and technical assistance of the RMIT University and John Curtin School of Medical Research, Australian National University


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 20 - 20
17 Nov 2023
van Duren B France J Berber R Matar H James P Bloch B
Full Access

Abstract. Objective. Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. Methods. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants. Results. At a mean of 8.4 years follow-up, 308 implants underwent revision equating to 3.58 revisions per 1000 implant-years. The lowest risk of revision was noted in the ATTUNE cohort with 2.98 per 1000-implant-years where the PFC and All Other Implant groups were 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision across all cemented implants with 76% (65/88) of involving loosening of the tibia. Survival analysis comparing the ATTUNE cohort to the PFC and All Other Cemented Implant cohorts showed no significant differences for: all-cause revision, aseptic loosening, or tibial loosening (p=0.15,0.77,0.47). Radiolucent lines were detected in 4.6%, 5.8%, and 5.0% of the ATTUNE S+, standard ATTUNE, and PFC groups respectively. These differences were not significant. Conclusion. This study represents the largest non-registry review of the original and S+ ATTUNE TKR in comparison to its predicate design as well as other cemented implants. There appears to be no significant increased revision rate for all-cause revision or aseptic loosening. Radiographic analysis also showed no significant difference in peri-implant radiolucency. It appears that concerns of early loosening may be unfounded. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 94 - 94
1 Mar 2021
Gallo J Kudelka M Radvansky M Kriegova E
Full Access

Precision medicine tailoring the patient pathway based on the risk, prognosis, and treatment response may bring benefits to the patients. To identify risk factors contributing to the early failure of treatment (development of events of interest) and when possible to change the prognosis via modifying these factors may improve the outcome and/or lower the risk of complications. There is an emerging goal to identify such parameters in total knee arthroplasty (TKA) thus lower the risk of revision surgery. The goal of this study was to identify factors explaining the risk for early revision of TKA using an artificial intelligence method appropriate for this task. We applied a patient similarity network (PSN) for the identification of risk factors associated with early reoperations (n=109, 5.8%) in patients with TKA (n=1885). Next, an algorithm based on formal concept analysis was developed to support the patient decision on how to change modifying personal characteristics with respect to the estimated probability of reoperations. The early reoperations were less frequent in women (4.4%, median time to reoperation 4.5 mo) than in men (8.2%, 10 mo), reaching the highest incidence in younger men (10.9%)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 77 - 77
1 Mar 2021
Wang J Roberts S McCarthy H Tins B Gallacher P Richardson J Wright K
Full Access

Abstract. Objectives. Meniscus allograft and synthetic meniscus scaffold (Actifit. ®. ) transplantation have shown promising outcomes for symptoms relief in patients with meniscus deficient knees. Untreated chondral defects can place excessive load onto meniscus transplants and cause early graft failure. We hypothesised that combined ACI and allograft or synthetic meniscus replacement might provide a solution for meniscus deficient individuals with co-existing lesions in cartilage and meniscus. Methods. We retrospectively collected data from 17 patients (16M, 1F, aged 40±9.26) who had ACI and meniscus allograft transplant (MAT), 8 patients (7M, 1F, aged 42±11) who underwent ACI and Actifit. ®. meniscus scaffold replacement. Other baseline data included BMI, pre-operative procedures and cellular transplant data. Patients were assessed by pre-operative, one-year and last follow-up Lysholm score, one-year repair site biopsy, MRI evaluations. Results. In the MAT group, the final post-operative evaluation was 7±4.5 years. The mean pre-operative Lysholm score was 49±17, rose to 66.6±16.4 1 year post-op and dropped to 58±26 at final evaluation. Four of the 17 patients had total knee replacements (TKRs) at average 6.4 years after treatment. In the Actifit. ®. group, the final post-operative assessment was 5.6±2.7years. The pre-operative Lysholm score was 53.7±21.3, increasing to 72.8±15.2 at 1 year and 70.4±27.6 at final clinical follow-up. None of the patients in the Actifit® group had received TKRs. Conclusions. Both MAT and Actifit. ®. groups were effective in improving patients symptoms and knee function according to one-year post-operative assessments. However, the knee function of patients in MAT group dropped at final follow-up, whereas the Actifit® group maintained their knee function. These preliminary findings warrant further investigations, to include more patients and alongside comparisons to ACI alone and allograft/Actifit. ®. alone as comparator groups before accurate conclusions may be drawn on the comparative efficacy of each technique. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 28 - 28
1 Jan 2019
Mawdesley A Tyson-Capper A Kirby J Tipper JL
Full Access

Increased revision rates and early failure of Metal-on-Metal (MoM) hip replacements are often due to adverse reaction to metal debris (ARMD). Cobalt is a major component of MoM joints and can initiate an immune response via activation of the innate immune receptor Toll-like receptor 4 (TLR4). This leads to increased secretion of inflammatory cytokines/chemokines e.g. CCL3 and CCL4. The aim of this study was to evaluate whether TLR4-specific neutralising antibodies can prevent cobalt-mediated activation of TLR4. MonoMac 6 (MM6) cells, a human macrophage cell line, were treated with two different TLR4-specific monoclonal antibodies followed by 0.75mM of cobalt chloride (CoCl2). Lipopolysaccharide (LPS), a known TLR4 agonist was used as a positive control. Enzyme-linked immunosorbent assay (ELISA) was used to assess CCL3/CCL4 protein secretion and real time- polymerase chain reaction (RT-PCR) allowed quantification of CCL3/CCL4 gene expression. MM6 cells treated with cobalt and LPS up-regulate CCL3 and CCL4 gene expression and protein secretion. MM6 cells pre-treated with both monoclonal antibodies prior to stimulation with 0.75mM CoCl2 for 16 hours demonstrated significant inhibition of both CCL3 and CCL4 secretion as well as gene expression (both p=<0.0001). One of the antibodies failed to inhibit chemokine expression and secretion in LPS treated cells. This study identifies for the first time the use of TLR4-specific monoclonal antibodies to prevent cobalt activation of TLR4 and subsequent inflammatory response. This finding demonstrates the potential to exploit TLR4 inhibition in the context of MoM joint replacements by contributing to the development of novel therapeutics designed to reduce the incidence of ARMD


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 39 - 39
1 Jan 2019
Williams D Metcalfe A Madete J Whatling G Kempshall P Forster M Holt C
Full Access

One of the main surgical goals when performing a total knee replacement (TKR) is to ensure the implants are properly aligned and correctly sized; however, understanding the effect of alignment and rotation on the biomechanics of the knee during functional activities is limited. Cardiff University has unique access to a group of local patients who have relatively high frequency of poor alignment, and early failure. This provides a rare insight into how malalignment of TKR's can affect patients from a clinical and biomechanical point of view to determine how to best align a TKR. This study aims to explore relationship clinical surgical measurements of Implant alignment with in-vivo joint kinematics. 28 patient volunteers (with 32 Kinemax (Stryker) TKR's were recruited. Patients undertook single plane video fluoroscopy of the knee during a step-up and step-down task to determine TKR in-vivo kinematics and centre of rotation (COR). Joint Track image registration software (University of Florida, USA) was used to match CAD models of the implant to the x-ray images. Hip-Knee-Ankle (HKA) was measured using long-leg radiographs to determine frontal plane alignment. Posterior tibial slope angle was calculated using radiographs. An independent sample t-test was used to explore differences between neutral (HKA:-2° to 2°), varus (≥2°) and valgus alignment (≤-2°) groups. Other measures were explored across the whole cohort using Pearson's correlations (SPSS V23). There was found to be no statistical difference between groups or correlations for HKA. The exploratory analysis found that tibial slope correlated with Superior/Inferior translation ROM during step up (r=−0.601, p<0.001) and step down (r=−.512, p=0.03) the position of the COR heading towards the lateral (r=−.479, p=0.006) during step down. Initial results suggest no relationship between frontal plane alignment and in-vivo. Exploratory analyses have found other relationships that are worthy of further research and may be important in optimizing function


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 48 - 48
1 Mar 2012
Beaulé PE
Full Access

The renewed interest in the clinically proven low wear of the metal-on-metal bearing combined with the capacity of inserting a thin walled cementless acetabular component has fostered the reintroduction of hip resurfacing. As in other forms of conservative hip surgery, i.e. pelvic osteotomies and impingement surgery, patient selection will help minimize complications and the need for early reoperation. Patient Selection and Hip Resurfacing. Although hip resurfacing was initially plagued with high failure rates, the introduction of metal on metal bearings as well as hybrid fixation has shown excellent survivorships of 97 to 99% at 4 to 5 years follow-up. However, it is important to critically look at the initial published results. In all of these series there was some form of patient selection. For example, in the Daniel and associates publications, only patients with osteoarthritis with an age less than 55 were included with 79% of patients being male. Treacy and associates stated that: “the operation was offered to men under the age of 65 years and women under the age of 60 years, with normal bone stock judged by plain radiographs and an expectation that they would return to an active lifestyle, including some sports”. However in the materials and methods, although the mean age is 52 years, the range is from 17 to 76 years including some patients with rheumatoid arthritis as well as osteonecrosis. Obviously, some form of patient selection is needed; but how one integrates them is where the Surface Arthroplasty Risk Index (SARI) is useful. With a maximum score of 6, points are assigned accordingly: femoral head cyst >1cm: 2 points; patient weight <82kg: 2 points; previous hip surgery: 1 point; UCLA Activity level >6: 1 point. A SARI score >3 represented a 4 fold increase risk in early failure or adverse radiological changes and with a survivorship of 89% at four years. The SARI index also proved to be relevant in assessing the outcome of the all cemented McMinn resurfacing implant (Corin¯, Circentester, England) at a mean follow-up of 8.7 years. Hips which had failed or with evidence of radiographic failure on the femoral side had a significantly higher SARI score than the remaining hips, 3.9 versus 1.9. Finally, one must consider the underlying diagnosis when evaluating a patient for hip resurfacing. In cases of dysplasia, acetabular deficiencies combined with the inability of inserting screws through the acetabular component may make initial implant stability unpredictable. This deformity in combination with a significant leg length discrepancy or valgus femoral neck could compromise the functional results of surface arthroplasty, and in those situations a stem type total hip replacement may provide a superior functional outcome. In respect to other diagnoses (osteonecrosis, inflammatory arthritis), initial analyses have not demonstrated any particular diagnostic group at greater risk of earlier failure. The only reservation we have is in patients with compromised renal function since metal ions generated from the metal-on-metal bearing are excreted through the urine and the lack of clearance of these ions may lead to excessive levels in the blood. Surgical Technique. Because resurfacing has not been within the training curriculum of orthopaedic surgeons for the last 2 decades, there will most likely be a learning curve in the integration of this implant within clinical practice. This data was confirmed for hip resurfacing when looking at the Canadian Academic Experience where in the first 50 cases of five arthroplasty surgeons only a 3.2% failure rate was noted of which 1.6% were due to neck fracture. Femoral neck fracture can occur because of significant varus positioning as well as osteonecrosis of the femoral head due to either disruption of the blood supply or over cement penetration. Finally, abnormal wear patterns leading to severe soft tissue reactions are being increasingly recognized and are related to either impingement or vertically placed acetabular components. Although impingement has long been recognized after total hip arthroplasty to limit range of motion and in extreme cases to hip instability, the risk after hip resurfacing may be greater since the femoral head-neck unit is preserved. Beaulé and associates have reported that 56% of hips treated by hip resurfacing have an abnormal offset ratio pre-operatively, with the two main diagnostic groups presenting deficient head-neck offset being osteonecrosis and osteoarthritis both of which have been associated with femoroacetabular impingement in the pre arthritic state. Conclusion. Although patients with a high activity level are likely to put their hip arthroplasties at risk for earlier failure, limiting a patient's activity because of fear of revision with a stem type hip arthroplasty has been shown to negatively impact the quality of life at long term follow-up. Thus hip resurfacing arthroplasty plays a significant role in the treatment of hip arthritis by permitting a return to full activities or what the patient perceives as his/her full capacities to do so, permitting them to enjoy a better quality of life without fearing a major hip revision


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 10 - 10
1 May 2017
Mawdesley A Anjum S Lawrence H Deehan D Kirby J Tyson-Capper A
Full Access

Background. Increased revision rates and early failure of Metal-on-Metal (MoM) hip replacements are often due to adverse reaction to metal debris (ARMD). ARMD describes numerous symptoms in patients such as pain, osteolysis and soft tissue damage. Cobalt is a major component of MoM joints and can initiate an immune response via activation of the innate immune receptor Toll-like receptor 4 (TLR4). This leads to increased secretion of inflammatory cytokines e.g. interleukin-8 (IL-8). This study investigates whether TLR4-specific antagonists inhibit the inflammatory response to cobalt using IL-8 gene expression and protein secretion as a marker of TLR4 activation. Methods. MonoMac 6 (MM6) cells, a human macrophage cell line, were treated with TLR4-specific antagonists followed by 0.75mM of cobalt chloride. Lipopolysaccharide (LPS), a known TLR4 agonist was used as a positive control. Enzyme-linked immunosorbent assay (ELISA) was used to assess IL-8 protein secretion and real time- polymerase chain reaction (RT-PCR) allowed quantification of IL-8 gene expression. Results. MM6 cells treated with cobalt and LPS up-regulate IL-8 gene expression and protein secretion (n=3). The addition of TLR4-specific antagonists significantly inhibits this up-regulation suggesting the observed effects are TLR4-mediated. MM6 cells stimulated with cobalt (0.75mM) for 16 hours demonstrated a 27-fold increase in IL-8 gene expression (p-value = < 0.0001). When pre-treated with 10μg/ml of a TLR4-specific antagonist fold increase decreased to 6-fold (p-value = < 0.0001). IL-8 secretion decreased from 5000pg/ml to 3000pg/ml (p-value = < 0.0001). Conclusion. TLR4-specific antagonists inhibit cobalt-mediated IL-8 gene expression and protein secretion in MM6 cells. This finding demonstrates the potential to exploit this inhibition in the context of MoM joint replacements by contributing to the development of novel therapeutics designed to improve MoM implant longevity, reduce the incidence of ARMD and prevent subsequent revision surgery


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 93 - 93
1 Apr 2017
Karaaslan A Karakaşlı A Ertem F Aycan H
Full Access

Background. Intramedullary nailing is a widely accepted treatment method for femoral fractures. Failure of locking screws is often a threatening complication, particularly on comminuted fractures. For comminuted fractures, the locking nails are load-bearing devices. The load transfer between fractured fragments is made through especially the locking screws for these load bearing situations. Nonunion, malunion, delayed union, shortening, and nail migration are the expected results if early failure of locking screws is present with comminuted fractures. In this study our aim was to compare the bending resistance of titanium and stainless steel locking screws. Methods. We tested 60 locking screws in six groups (titanium, stainless steel, unthreaded, low threaded and high threaded) in a steel tube that has 30 mm inner diameter, which imitates the lesser trochanter level. We determined the yield points at three-point bending tests that permanent deformation started in the locking screws using an axial compression testing machine. Results. The three-point bending resistance of 5 mm low threaded titanium locking screws (bending at 1413 N loading) was 46.5 % less than the three-point bending resistance of 5 mm low threaded stainless steel locking screws (bending at 2171 N loading) (p < 0.001). Five mm stainless steel locking screws are 29–57 % more resistant to three-point bending deformation than titanium ones. Conclusions. Therefore, stainless steel locking screws instead of titanium ones must be preferred in comminuted femur shaft fractures. In intramedullary nailing of comminuted or long oblique femur fractures, a locking screw should be 5 mm low threaded or unthreaded stainless steel or 5 mm unthreadedtitanium. Five mm high threaded titanium or stainless steel screws must not ever be used as a locking screw. Level of Evidence. 5. Disclosure. Authors declare that there is no conflict of interest related to the present study


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 13 - 13
1 Mar 2013
Matthies A Racasan R Bills P Panagiotidou A Blunt L Skinner J Blunn G Hart A
Full Access

Material loss at the head-stem taper junction may contribute to the high early failure rates of stemmed large head metal-on-metal (LH-MOM) hip replacements. We sought to quantify both wear and corrosion and by doing so determine the main mechanism of material loss at the taper. This was a retrospective study of 78 patients having undergone revision of a LH-MOM hip replacement. All relevant clinical data was recorded. Corrosion was assessed using light microscopy and scanning electron microscopy, and graded according to a well-published classification system. We then measured the volumetric wear of the bearing and taper surfaces. Evidence of at least mild taper corrosion was seen in 90% cases, with 46% severely corroded. SEM confirmed the presence of corrosion debris, pits and fretting damage. However, volumetric wear of the taper surfaces was significantly lower than that of the bearing surfaces (p = 0.015). Our study supports corrosion as the predominant mechanism of material loss at the taper junction of LH-MOM hip replacements. Although the volume of material loss is low, the ionic products may be more biologically active compared to the particulate debris arising from the bearing surfaces


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 12 - 12
1 Mar 2013
Bolland B Roques A Maul C Cook R Wood R Tuke M Latham J
Full Access

The poor outcome of large head metal on metal total hip replacements (LHMOMTHR) in the absence of abnormal articulating surface wear has focussed attention on the trunnion / taper interface. The RedLux ultra-precision 3D form profiler provides a novel indirect optical method to detect small changes in form and surface finish of the head taper as well as quantitative assessment of wear volume. This study aimed to assess and compare qualitatively tapers from small and large diameter MOMTHR's. Tapers from 3 retrieval groups were analysed. Group 1: 28mm CoCr heads from MOMTHRs (n=5); Group 2: Large diameter CoCr heads from LHMOMTHRs (n=5); Gp 3 (control): 28mm heads from metal on polyethylene (MOP) THRs; n=3). Clinical data on the retrievals was collated. RedLux profiling of tapers produced a taper angle and 3D surface maps. The taper angles were compared to those obtained using CMM measurements. There was no difference between groups in mean 12/14 taper angles or bearing surface volumetric and linear wear. Only LHMOMs showed transfer of pattern from stem trunnion to head taper, with clear demarcation of contact and damaged areas.3D surface mapping demonstrated wear patterns compatible with motion or deformations between taper and trunnion in the LHMOM group. These appearances were not seen in tapers from small diameter MOM and MOP THRs. Differences in appearance of the taper surface between poorly functioning LHMOMTHRs and well functioning MOP or MOM small diameter devices highlight an area of concern and potential contributor to the mode of early failure


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 62 - 62
1 Aug 2013
Soon V Chirputkar K Gaheer R Corrigan N Picard F
Full Access

Component malrotation in total knee arthroplasty (TKA) is a reason for early failure and revision. Assessment of possible component malrotation using computed tomography (CT) might be useful when other differentials have been excluded. The aims of our study were to determine the proportion of symptomatic patients with component malrotation on CT, and review the subsequent management of such patients. A retrospective review of case notes was performed locally for all patients who had a CT scan for a painful TKA. Measurements of the femoral and tibial component rotations were done according to the standard Berger protocol, giving net degrees of either external rotation (ER) or internal rotation (IR). Any subsequent surgery was noted, and patients were followed up as per local practice. Between 2007 and April 2012, 69 knees in 68 patients had CT scans. There were 25 males and 43 females, and mean age at primary surgery was 65.03 years. The mean femoral component rotation for all knees was 0.1° ER (range 7.0° ER – 6.7° IR), and the mean tibial component rotation for all knees was 19.1° IR (6.6° ER – 37.0° IR). No statistically significant difference was found comparing the mean femoral and tibial component rotations between patients with and without further surgery. Further surgery was performed on 39 (56.5%) knees. Overall, there were ten cases (14.5%) of isolated femoral malrotation, 26 tibial malrotation (37.7%), and two cases (2.9%) had malrotation of both components. Out of these 38 cases, secondary surgery was performed in 22 knees (57.9%), of which a satisfactory outcome was achieved in fifteen cases (68.1%). It is impossible to establish component malrotation as the only cause of pain following TKA, however, our study does show that the Berger protocol has its uses when other causes have been excluded


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 41 - 41
1 Mar 2012
Beaulé PE
Full Access

Femoral neck fractures remain the leading cause of early failure after metal-on-metal hip resurfacing. Although its' exact pathomechanism has yet to be fully elucidated, current retrieval analysis has shown that either an osteonecrotic event and/or significant surgical trauma to the femoral head neck junction are the leading causes. It is most likely that no single factor like patient selection and/or femoral component orientation can fully avoid their occurrence. As in osteonecrosis of the native hip joint, a certain cell injury threshold may have to be reached in order for femoral neck fracture to occur. These insults are not limited to the surgical approach, but also include femoral head preparation, neck notching, and cement penetration. Although some have argued that the posterior approach does not represent an increased risk fracture for ON after hip resurfacing because of the so-called intraosseous blood supply to the femoral head, to date, the current body of literature on femoral head blood flow in the presence of arthritis has confirmed the critical role of the extraosseous blood supply from the ascending branch of the medial circumflex, as well as the lack of any substantial intraosseous blood supply. Conversely, anterior hip dislocation of both the native hip joint as well as the arthritic hip preserves femoral head vascularity. The blood supply can be compromised by either sacrificing the main branch of the ascending medial femoral circumflex artery or damaging the retinacular vessels at the femoral head-neck junction. Thus an approach which preserves head vascularity, while minimizing soft tissue disruption would certainly be favorable for hip resurfacing. This presentation will review the current state of knowledge on vascularity of the femoral head as well as surgical techniques enhancing its preservation


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 741 - 744
1 May 2005
Beaulé PE Krismer M Mayrhofer P Wanner S Le Duff M Mattesich M Stoeckl B Amstutz HC Biedermann R

Studies on the migration of an implant may be the only way of monitoring the early performance of metal-on-metal prostheses. The Ein Bild Roentgen Analyse - femoral component analysis (EBRA-FCA) method was adapted to measure migration of the femoral component in a metal-on-metal surface arthroplasty of the hip using standard antero-posterior radiographs. In order to determine the accuracy and precision of this method a prosthesis was implanted into cadaver bones. Eleven series of radiographs were used to perform a zero-migration study. After adjustment of the femoral component to simulate migration of 3 mm the radiographs were repeated. All were measured independently by three different observers. The accuracy of the method was found to be ± 1.6 mm for the x-direction and ± 2 mm for the y-direction (95% percentile). The method was validated using 28 hips with a minimum follow-up of 3.5 years after arthroplasty. Seventeen were sound, but 11 had failed because of loosening of the femoral component. The normal (control) group had a different pattern of migration compared with that of the loose group. At 29.2 months, the control group showed a mean migration of 1.62 mm and 1.05 mm compared with 4.39 mm and 4.05 mm in the failed group, for the centre of the head and the tip of the stem, respectively (p = 0.001). In the failed group, the mean time to migration greater than 2 mm was earlier than the onset of clinical symptoms or radiological evidence of failure, 19.1 versus 32.2 months (p = 0.001) and 24.8 months (p = 0.012), respectively. EBRA-FCA is a reliable and valid tool for measuring migration of the femoral component after surface arthroplasty and can be used to predict early failure of the implant. It may be of value in determining the long-term performance of surface arthroplasty


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 9 - 9
1 Apr 2014
Marsh A Nisar A El Refai M Meek R Patil S
Full Access

When performing total hip replacements in patients with hip dysplasia, acetabular augmentation may be required to prevent early component failure. Preoperative radiographic templating may help estimate acetabularcomponent coverage but has not previously been shown to predict the need for augmentation. We developed a simple method to estimate the percentage of acetabular component coverage from pre-operative radiographs (True: False cup ratio). We aimed to evaluate whether this couldpredict the need foracetabular augmentation at primary total hip replacement for patients with dysplastic hips. We reviewed all patients with hip dysplasia who underwent a primary total hip replacement from 2005–2012. Classification of hip dysplasia (Crowe), centre edge angle (CEA), Sharp and Tonnis angles were determined on pre-operative radiographs for each patient. Templating was performed on anteroposteriorand lateral view hip radiographs to determine the likely percentage of acetabular component coverage using the True: False cup ratio. Patients requiring acetabular augmentation at time of primary total hip arthroplasty were noted. 128 cases were reviewed, 31 (24%) required acetabularaugmentation. Comparison between augmented and non-augmented cases revealed no difference in the mean CEA (p = 0.19), Sharp angles (p = 0.76) or Tonnis angles (p = 0.32). A lower True Cup: False Cup ratio was observed in the augmented groupcompared to the non-augmented group(median = 0.68 vs 0.88, p < 0.01). Preoperative templating can help predict which dysplastic hips are likely to require acetabular augmentation at primary total hip replacement


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 130 - 130
1 Jul 2014
Schneider K Zderic I Gueorguiev B Richards R Nork S
Full Access

Summary. Biomechanically, a 2° screw deviation from the nominal axis in the PFLCP leads to significantly earlier implant failure. Screw deviation relies on a technical error on insertion, but in our opinion cannot be controlled intraoperatively with the existing instrumentation devices. Background. Several cases of clinical failure have been reported for the Proximal Femoral Locking Compression Plate (PFLCP). The current study was designed to investigate the failure mode and to explore biomechanically the underlying mechanism. Specifically, the study sought to determine if the observed failure was due to technical error on insertion or due to implant design. Methods. To exclude patient and fracture type related factors, an abstract foam block model simulating an unstable pertrochanteric fracture was created for three study groups with six specimens each (n=6). Group 1 was properly instrumented according to the manufacturer's guidelines. In Group 2 and 3, the first or second screw was placed in a posterior or anterior off-axis orientation by 2° measured in the transversal plane, respectively. Each construct was tested cyclically until failure using a test setup and protocol simulating complex axial and torsional loading. Radiographs were taken prior to and after the tests. Force, number of cycles and failure mode were compared. Results. The 2° screw deviation from the nominal axis led to significantly earlier construct failure in Group 2 and 3. The failure mode consisted of loosening of the off-axis screw due to disengagement with the plate, resulting in loss of construct stiffness and varus collapse of the fracture. Conclusions. In our biomechanical test setup, a screw deviation of only 2° from the nominal axis consistently led to the failure mode observed clinically. In our opinion, screw deviation mostly relies on technical error on insertion. But, proper screw insertion may be difficult or impossible with the existing instrumentation devices, especially as it cannot be controlled or guaranteed intraoperatively


Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives

The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic.

Methods

We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs.


Bone & Joint Research
Vol. 6, Issue 11 | Pages 631 - 639
1 Nov 2017
Blyth MJG Anthony I Rowe P Banger MS MacLean A Jones B

Objectives

This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.

Methods

A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.