Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 57 - 57
1 Mar 2017
Ul Islam S Carter P Fountain J Afzaal S
Full Access

Implant choice was changed from cemented Thompson to Exeter Trauma Stem (ETS) for treatment of displaced intra-capsular neck of femur fractures in University Hospital Aintree, Liverpool, United Kingdom (a major trauma center), following the NICE guidelines that advised about the use of a proven femoral stem design rather than Austin Moore or Thompson stems for hemiarthroplasties. The aim of our study was to compare the results of Thompson versus ETS hemiarthroplasty in Aintree. We initially compared 100 Thompson hemiarthroplasties that were performed before the start of ETS use, with 100 ETS hemiarthroplasties. There was no statistically significant difference between the two groups in terms of patients' demographics (age, sex and ASA grade), intra-operative difficulties/complications, post op medical complications, blood transfusion, in-patient stay and dislocations. The operative time was statistically significantly longer in the ETS group (p= .0067). Worryingly, the 30 days mortality in ETS group was more than three times higher in ETS group (5 in Thompson group versus 16 in ETS group. P= .011). To corroborate our above findings we studied 100 more consecutive patients that had ETS hemiarthroplasty. The results of this group showed 30 day mortality of 8 percent. However the operative time was again significantly longer (p= .003) and there was 18 percent conversion to bipolar hemiarthropalsty. Moreover there was statistically significant increased rate of deep infection (7%, p = .03) and blood transfusion (27%, p = .007). This we feel may be due to longer and more surgically demanding operative technique including pressurised cementation in some patients with significant medical comorbidities. Our results raise the question whether ETS hemiarthoplasty implant is a good implant choice for neck of femur fracture patients. Randomised control trials are needed to prove that ETS implant is any better than Thompson hemiarthroplasty implants in this group of patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 31 - 31
1 Sep 2012
Hossain M Andrew G
Full Access

Introduction. Following National patient safety alert on cement use in hip fracture surgery, we investigated the incidence and pattern of 72 hours peri-operative mortality after hip fracture surgery in a District General Hospital. Methods. We reviewed all patients who had hip fracture surgery between 2005-April, 2010. We recorded demographic variables, type of fracture, implant used, medical co-morbidity, seniority of operating surgeon and anaesthetist, peri-operative haemodynamic status, time and cause of death. Results. Over a 64 month period 15 cases were identified. Peri-operative death (PAD) was 1% (15/1402). 4/15 patients died intra-operatively. PAD was highest following Exeter Trauma Stem (ETS) implantation (5/85, 6%) and nil following Bipolar arthroplasty, Austin-Moore arthroplasty (AMA) or Cannulated screw fixation. PAD following total hip arthroplasty was 4% (1/25), Thompson's hemi-arthroplasty 2% (3/191), and Dynamic Hip Screw fixation 1% (6/695). Overall mortality after cemented implant was 2%. ETS implantation led to significantly increased peri-operative mortality compared to AMA (p=0.004). Operations were performed by both trainees (12) and Consultants (3). Both trainees (9) and Consultants (6) anaesthetised the patients. None of the patients belonged to ASA I or II (ASA III 6 and IV 9). All patients had significant cardio-vascular or pulmonary co-morbidity (Ca Lung 2, pulmonary fibrosis 1, end stage COAD 1, AF 6). Cemented implant insertion was followed by immediate haemodynamic collapse and death in 4/15, intra-operative haemodynamic instability in 1/15 and peri-operative instability in 5/15. Post-mortem was performed in 5/15: 2/5 were Pulmonary Embolism (PE), 2/5 bronchopneumonia and 1/5 Myocardial infarction (MI). 4/15 had suspected MI and 1/15 suspected PE. Conclusion. There was 1% risk of peri-operative death after hip fracture surgery. This risk was increased following cemented hemiarthroplasty and highest after ETS implantation. Risk was exacerbated in patients with pre-existing cardiovascular morbidity and independent of the seniority of the surgeon or the anaesthetist


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 4 - 4
1 Apr 2013
Kassam A Griffiths S Higgins G
Full Access

Recent NICE guidelines have suggested abandoning the Thompson hemiarthroplasty (TH) in favour of a ‘proven prosthesis’ such as the Exeter Trauma Stem (ETS). This is controversial because of significant cost implications and limited research assessing outcomes of the ETS. The aim of this study was to assess the treatment of intracapsular neck of femur fractures with the TH. Between 2002 and 2006 (minimum 5 year follow-up), 431 cemented TH's were performed. Death rate at 1 year and 5 years were 26.0% and 67.7% respectively. Dislocation (1.4%) and infection (0.2%) rates were low and revision rate was 1.2%. Comparison was made to Bipolar hemiarthroplasties over the same period (total 194). These had lower rates of dislocation (0.5%) and infection (0.5%) with a significantly higher (3.6%) revision rate. We feel that the TH remains the current gold standard treatment for intracapsular fractures, in appropriate patients, due to low complication and revision rates. Modern implants may provide better function or longevity, but there is no evidence in the literature to support abandoning the TH. Surgeons should assess patients and decide on its use, despite NICE guidelines, as it remains a cost effective treatment method, particularly for older, less mobile and cognitively impaired patients