INTRODUCTION: Intervertebral degeneration is characterised by instability due to permanent decrease in the stiffness of the intervertebral segment and concentration of stress upon the posterior portion of the disc, and by morphologic changes in the posterior elements due to posterior displacement of loading, notably enlargement of the lamina and zygapophyseal joints. These changes lead to reduction in the cross-sectional area of the vertebral canal. In order to counterbalance these changes, an implant has been developed with an interspinous blocker and an artificial ligament made of Dacron. This obviates the need for a permanent fixation in the vertebral bone, avoiding the risk of loosening. Inhibition of hyperextension limits narrowing of the posterior canal, resulting in an increase in its cross-sectional area of up to 40%. A first-generation implant for nonrigid stabilisation of lumbar segments was developed in 1986 with a titanium interspinous blocker. Following an initial observational study in 1988 and a prospective controlled study from 1988 to 1993, more than 300 patients have been treated for degenerative lesions with significant resolution of residual low back pain with no serious adverse effects. After careful analysis of the points that could be improved,a second-generation,improved implant called the ‘Wallis implant’ was developed with a redesigned blocker made of PEEK (polyetheretherketone), a more resilient material. METHODS: Biomechanical studies were used to verify the effectiveness of this implant in increasing intervertebral stiffness, reducing mobility, and unloading the facet joints and the posterior portion of the disc. A prospective multicenter international observational study was begun a year ago. RESULTS: Preliminary results confirm the clinical efficacy of this treatment on low back pain and nerve root symptoms, especially in recurrent disc herniation and canal stenosis. DISCUSSION: Nonrigid intervertebral fixation with the Wallis implant clearly appears to be a useful technique in the management of initial forms of degenerative intervertebral lumbar disc disease. The method should rapidly assume a specific role along with total disc prostheses in the new step-wise surgical strategy to obviate definitive fusion of degenerative intervertebral segments. Moreover, dynamic stabilisation with the Wallis system is totally reversible and leaves all other options open. Wallis is recommended for patients with lumbar disc disease who have: (i) discectomy for massive herniated disc leading to substantial loss of disc material, (ii) a second discectomy for recurrence of herniated disc, (iii) discectomy for herniation of a transitional disc with sacralization of L5, (iv) degenerative disc disease at a level adjacent to a previous fusion or prosthesis, (v) isolated disc resorption, notably with concomitant type-1 Modic changes, associated with low back pain, or (vi) symptomatic narrow canal treated by resection of the superior aspect of the laminae.
Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.Aims
Methods
Purpose: Instability of the injured elbow early after repair can lead to recurrent dislocation or failed fixation. Complementary immobilisation increases the risk of stiffness. The purpose of this study was to assess the contribution of
We examined the effect of periosteal devascularisation upon the early healing of osteotomies of sheep tibiae held in an instrumented external fixation system with an axial stiffness of 240 N/mm. At 14 days, cortical blood flow measured by the microsphere technique was 19.3 ml/min/100g in the well-vascularised osteotomies, but only 1.7 ml/min/100g in the devascularised osteotomies, despite an increase in medullary flow (p less than 0.0005). Delay in healing of the devascularised osteotomies was suggested by an in vivo monitoring system and confirmed by post-mortem mechanical testing. We suggest that the osteogenic stimulus of
Pain, stiffness, instability and degenerative arthritis are common sequelae of complex fracture-dislocations of the proximal interphalangeal (PIP) joint. Operations were carried out to obtain stability, followed by application of a dynamic external fixator in 20 patients with a mean age of 29 years. This provided stability and distraction, and allowed controlled passive movement. Most (70%) of the patients had a chronic lesion and the mean time from injury to surgery was 215 days (3 to 1953). The final mean range of movement was 12 to 86°. Complications included redislocation and septic arthritis, which affected the outcome. Four pin-track infections and two breakages of the hinge did not influence the result. The PIP Compass hinge is a useful adjunct to surgical reconstruction of the injured PIP joint.
Femoral neck fractures account for half of all hip fractures and are recognized as a major public health problem associated with a high socioeconomic burden. Whilst internal fixation is preferred over arthroplasty for physiologically younger patients, no consensus exists about the optimal fixation device yet. The recently introduced implant Femoral Neck System (FNS) (DePuy Synthes, Zuchwil, Switzerland) was developed for
Nearly one quarter of ankle fractures have a recognized syndesmosis injury. An intact syndesmosis ligament complex stabilizes the distal tibio-fibular joint while allowing small, physiologic amounts of relative motion. When injured, malreduction of the syndesmosis has been found to be the most important independent factor that contributes to inferior functional outcomes. Despite this, significant variability in surgical treatment remains. This may be due to a poor understanding of normal dynamic syndesmosis motion and the resultant impact of static and
Three Cannulated Screws (3CS), Dynamic Hip Screw (DHS) with antirotation screw (DHS–Screw) or with a Blade (DHS–Blade) are the gold standards for fixation of unstable femoral neck fractures. Compared to 3CS, both DHS systems require larger skin incision with more extensive soft tissue dissection while providing the benefit of superior stability. The newly designed Femoral Neck System (FNS) for
INTRODUCTION. The elimination of motion and disc stress produced by spinal fusion may have potential consequences beyond the index level overloading the spinal motion segments and leading to the appearance of degenerative changes. So the “topping-off” technique is a new concept instructing
Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide. All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age.Aims
Methods
The ideal management of acute syndesmotic injuries in elite athletes is controversial. Among several treatment methods used to stabilize the syndesmosis and facilitate healing of the ligaments, the use of suture tape (InternalBrace) has previously been described. The purpose of this study was to analyze the functional outcome, including American Orthopaedic Foot & Ankle Society (AOFAS) scores, knee-to-wall measurements, and the time to return to play in days, of unstable syndesmotic injuries treated with the use of the InternalBrace in elite athletes. Data on a consecutive group of elite athletes who underwent isolated reconstruction of the anterior inferior tibiofibular ligament using the InternalBrace were collected prospectively. Our patient group consisted of 19 elite male athletes with a mean age of 24.5 years (17 to 52). Isolated injuries were seen in 12 patients while associated injuries were found in seven patients (fibular fracture, medial malleolus fracture, anterior talofibular ligament rupture, and posterior malleolus fracture). All patients had a minimum follow-up period of 17 months (mean 27 months (17 to 35)).Aims
Methods
Introduction. Ankle fusion presents a difficult problem in the presence of infection, inadequate soft tissue, poor bone stock and deformity. Nonunion and infection remains a problem even with internal fixation. Ilizarov frame provides an elegant solution to the problem with stable remote fixation while allowing lengthening, deformity correction and weight bearing. Patients and methods. Twenty-one consecutive patients were studied. The mean age at onset of disease was 52 years (range 4-70). Mean duration of the problem was 59.9 months (6-372). Aetiology included traumatic arthritis in 5, traumatic arthritis with osteomyelitis in 1, failed ankle fusion in 8, septic arthritis in 1, infected ankle fracture nonunion in 1, avascular necrosis of talus in 1, congenital deformity in 3 and failed ankle arthroplasty in 1. 15 patients had deformity of the ankle at the time of presentation. 15 of the 21 patients had either clinical or radiological evidence of infection. Treatment principles involved local excision, deformity correction with good alignment and soft tissue management. Static Compression was achieved with an Ilizarov frame while
The results obtained with a lightweight dynamic axial fixator in the treatment of fractures are reported. The apparatus comprises a single bar with articulating ends which clamp self-tapping screws and can be locked at an angle appropriate for axial alignment. A telescopic facility allows ready conversion from rigid to
In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years. A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years.Aims
Methods
We enrolled 34 normal volunteers to test the hypothesis that there were two types of movement of the wrist. On lateral radiographs two distinct patterns of movement emerged. Some volunteers showed extensive rotation of the lunate with a mean range of dorsiflexion of 65°, while others had a mean range of 50°. The extensive rotators were associated with a greater excursion of the centre of articulation of the wrist. It is suggested that
We describe a technique for slow, progressive, symmetrical distraction of the growth plate using a lightweight
Introduction and Aims: Eight thousand Duraloc 300 cups were implanted worldwide in 2002. To our knowledge, no 10-year results have been published to date. We undertook this study to ascertain whether this optimism was justified. Method: One hundred consecutive total hip replacements using a Duraloc 300 cup were reviewed at a minimum of 10 years. Post-operative x-rays were analysed for cup placement and interface gaps. Follow-up films were analysed for lucent lines, osteolysis, wear and migration. Kaplan-Meier survivorship analysis was performed. Results: All components were found to be stable with no evidence of loosening or migration. The mean rate of wear was 0.12mm per year. Three hips developed pelvic osteolysis in zone 2 at the level of the apex hole, of which two have successfully undergone a bone grafting procedure and one patient is awaiting surgery. Conclusion: The Duraloc 300 cup has excellent 10-year results with no cases of loosening. There was a low incidence of pelvic osteolysis. Cementless
Introduction: We prospectively followed all hip fracture patients admitted between 2004–2006, identified cases where the intention was to treat conservatively and compared their functional outcome and mortality with a similar cohort treated surgically over the same period. Methods: We recorded length of hospital stay, place of discharge, pre and post-fracture mobility and residence, 30 day and 1 yr mortality, re-admission and delayed surgery. The group treated surgically was recruited and matched for age, gender, pre and post fracture mobility, mental confusion and independence with the conservatively treated group. Results: 25 patients were treated conservatively. 22 patients treated surgically over the same period were recruited. The mean hospital stay was 13 days in both groups. There were 4 extracapsular (3 displaced) and 21 intracapsular fractures (5 displaced) in the conservative arm and 11 extracapsular and 9 intracapsular fractures in the surgically treated arm. 4 patients from the conservative treatment group underwent late surgery 20 days – 2 months after the index event. Surgically treated group had 11