Tibial nonunion represents a spectrum of conditions
which are challenging to treat, and optimal management remains unclear
despite its high rate of incidence. We present 44 consecutive patients
with 46 stiff tibial nonunions, treated with hexapod external fixators
and
We present a series of ten hypertrophic nonunions in which bony alignment and length were restored and union induced by external fixation and callus
Objective:. To assess efficacy of pulsed ultrasound for accelerating regenerate consolidation. Design:. A multicentre two arm patient and assessor double blind RCT. Setting:. Four UK centres (Edinburgh, Belfast, Liverpool, Bristol). Participants:. 62 skeletally mature adults undergoing distraction osteogenesis of 2.5–10cm at the proximal tibia. Patients with metabolic bone disorders were excluded. Interventions:. A metaphysial corticotomy was created and an Ilizarov frame applied. After 7 days,
We conducted a multicentre two arm double blind randomised controlled trial to assess efficacy of pulsed ultrasound for accelerating the rate of bone healing. Sixty-two skeletally mature adults undergoing limb lengthening, of between 2.5cm to 10cm by distraction osteogenesis, at the proximal tibia using an Ilizarov frame were randomised to either an active or a placebo (control) ultrasound device. Primary outcome measure was time ready for removal of frame after adjusting for
Several low energy osteotomy techniques are described in the literature but there is limited evidence comparing healing indices. We present a retrospective review of two techniques to evaluate an optimum method. Method:. Two cohorts of patients underwent osteotomy of the tibia using a Gigli saw (n=15) or DeBastiani corticotomy (n=12) technique. Indications for surgery included limb lengthening and bone transport for defect reconstruction with a minimal
A systematic literature review of distraction osteogenesis (DO) for the primary reconstruction of bone defects following resection of primary malignant tumours of long bones (PMTLB) is presented. Fewer than 50 cases were identified. Most reports relate to benign tumours or secondary reconstructive procedures. The outcomes of our own series of 7 patients is also presented (4 tibiae, 3 femora). All patients had isolated bone lesions without metastases and were assessed through the hospital sarcoma board. Mean follow-up was 59 months (17–144). Mean age was 42 years. Final histologic diagnoses were 3 chondrosarcoma, 2 malignant fibrous histiocytoma, 1 adamantinoma and 1 malignant intraosseous nerve sheath tumour. Mean bone defect after resection was 13.1cm (10–17) and bone transport was the reconstruction method in all. There was one local recurrence of tumour six months post-resection, necessitating amputation. Mean frame index for remaining cases was 30.9 days/cm (15.7–41.6). Complications included pin infection, docking site non-union, premature corticotomy union, soft-tissue infection and minor varus deformity. Six cases remain tumour-free with united, well-aligned bones and good long-term function. We conclude DO provides an effective biologic reconstruction option in select cases of PMTLB.
Aims. The aim of this double-blind prospective randomised controlled
trial was to assess whether low intensity pulsed ultrasound (LIPUS)
accelerated or enhanced the rate of bone healing in adult patients
undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone
transport by distraction osteogenesis were randomised to treatment
with either an active (n = 32) or a placebo (n = 30) ultrasound
device. A standardised corticotomy was performed in the proximal
tibial metaphysis and a circular Ilizarov frame was used in all
patients. The rate of
Aims. To investigate a treatment algorithm of various Ilizarov methods in managing infected tibial non-union. Patients and Methods. A consecutive series of 76 patients with infected tibial non-union were treated with one of four Ilizarov protocols, consisting of; monofocal
Aims. The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral locked plate and a six-pin monorail
fixator on its anteromedial surface. A corticotomy was performed
at the appropriate level. During the third stage, i.e. at the end
of the
Aim. Simultaneous application of Ilizarov frames and free muscle flaps to treat osteomyelitis or infected non-unions is currently not standard practice in the UK, in part related to logistical issues, surgical duration and challenging access for microvascular anastomosis. We present the outcomes for 56 such patients. Methods. Retrospective single centre consecutive series between 2005–2017. We recorded comorbidities, Cierny-Mader and Weber-Cech classification, the Ilizarov method used, flap and anastomosis used, follow-up duration, time to union and complications. Results. 56 patients (55 tibiae and 1 forearm) were included (mean age 48 years). Thirty-four cases had osteomyelitis (20/34 Cierny-Mader Stage IV) and 22 had an infected non-union (14/22 Weber-Cech Type E or F). Forty-six patients had a segmental defect after resection. Monofocal compression was used in 14, monofocal
Limb length deficiency, secondary to trauma or infection, is a common reason for referral to our tertiary service. After experiencing troubles with the Intramedullary Skeletal Kinetic Distractor (ISKD), we changed implant to the magnet operated Precice nail. We evaluated the safety and reliability of this novel device and compared it to our early ISKD results. To minimise variables, we selected femurs only. In total, we reviewed medical and radiographic records of 20 cases (8 ISKD, 12 Precise) from 2010–2015. At each postoperative visit, the accuracy and precision of
The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN). The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.Aims
Methods
The aims of this study were to identify means to quantify coronal plane displacement associated with distal radius fractures (DRFs), and to understand their relationship to radial inclination (RI). From posteroanterior digital radiographs of healed DRFs in 398 female patients aged 70 years or older, and 32 unfractured control wrists, the relationships of RI, quantifiably, to four linear measurements made perpendicular to reference distal radial shaft (DRS) and ulnar shaft (DUS) axes were analyzed: 1) DRS to radial aspect of ulnar head (DRS-U); 2) DUS to volar-ulnar corner of distal radius (DUS-R); 3) DRS to proximal capitate (DRS-PC); and 4) DRS to DUS (interaxis distance, IAD); and, qualitatively, to the distal ulnar fracture, and its intersection with the DUS axis.Aims
Methods
Abstract.
Aim and Purpose of the study. The authors evaluate the efficacy of athrodiatasis as possible alternative to arthrodesis or arthroplasty in the treatment of ankle arthritis in young patients. They present the long term results (average 19 years) of a small series of patients (10 cases) treated with a monolateral transarticular external fixator associated to different open or athroscopic procedures. Material and Methodology. The patients have been revaluated with the Kitaoka scoring scale associated to the x-ray evaluation. The authors will compare these results with those reported for the same series at an early evaluation (2,5 y of follow up) and with those published in literature. Discussion. Arthrodiatasis of the ankle with
Introduction.
Introduction. Segmental bone defect is a challenging problem. We report our experience of bone transport by hexapod external fixator in patients with segmental defects if the tibia. Method. We report herein 15 patients with segmental bone defect of tibia who completed their treatment protocol. All patients were treated had bone transport with Taylor Spatial Frame from 2012 to 2017. All were treated by the senior author NH. Parameters measured included age, sex, diabetes, smoking, diagnosis, method of fixation prior to treatment use of a free flap, bone defect size, frame-time, external fixation index. Results. Mean age at the time of frame application was 42.7 years. Mean follow-up after frame removal was 23.7 months. Three were diabetic, one smoked and one quit smoking during treatment. Seven had Gustilo-Anderson 3B (47%) and 5 Gustilo-Anderson 3A (33%) open fractures. Three (20%) had closed fractures. Nine (60%) had internal fixation with plate in eight and IM nail in one. Ten patients (67%) had soft tissue defect that required a free flap in seven, local flap in two and skin graft in one. Mean transport was 62 mm. Mean external fixator time and latency were 350.1 and 12 days, respectively. Mean External fixator,
Introduction. Since 2001 we use the flexible intramedullary nailing (FIN) in bone lengthening in children. This study estimates results of EF+FIN association considering the duration of external fixation and complications. Materials and Methods. Since 2001 we performed 294 bone lengthenings (338 segments of UL and LL) in 250 children 3 to 16 years old (11.01±0.23 in average). The length discrepancy was congenital in 163 cases, the sequelae of trauma or osteomyelitis were observed in 87 patients. In group I (195 cases) the Ilizarov fixator alone was applied, in group II the Ilizarov fixator (91 cases) or TSF® (8cases) were combined with FIN. The healing index was compared between the groups of the same etiology with similar type of
We assessed factors which may affect union in 32 patients with nonunion of a fracture of the diaphysis of the femur and 67 comparable patients whose fracture had united. These included gender, age, smoking habit, the use of non-steroidal anti-inflammatory drugs (NSAIDs) the type of fracture (AO classification), soft-tissue injury (open or closed), the type of nail, the mode of locking, reaming v non-reaming, infection, failure of the implant,
We present the results of 13 patients who suffered severe injuries to the lower leg. Five sustained a traumatic amputation and eight a Gustilo-Anderson type IIIC open fracture. All were treated with debridement, acute shortening and stabilisation of the fracture and vascular reconstruction. Further treatment involved restoration of tibial length by callus