Abstract
Introduction
Segmental bone defect is a challenging problem. We report our experience of bone transport by hexapod external fixator in patients with segmental defects if the tibia.
Method
We report herein 15 patients with segmental bone defect of tibia who completed their treatment protocol. All patients were treated had bone transport with Taylor Spatial Frame from 2012 to 2017. All were treated by the senior author NH. Parameters measured included age, sex, diabetes, smoking, diagnosis, method of fixation prior to treatment use of a free flap, bone defect size, frame-time, external fixation index.
Results
Mean age at the time of frame application was 42.7 years. Mean follow-up after frame removal was 23.7 months. Three were diabetic, one smoked and one quit smoking during treatment. Seven had Gustilo-Anderson 3B (47%) and 5 Gustilo-Anderson 3A (33%) open fractures. Three (20%) had closed fractures. Nine (60%) had internal fixation with plate in eight and IM nail in one. Ten patients (67%) had soft tissue defect that required a free flap in seven, local flap in two and skin graft in one. Mean transport was 62 mm. Mean external fixator time and latency were 350.1 and 12 days, respectively. Mean External fixator, distraction and maturation indices were 2.1, 0.52 and 1.43 month per centimeter, respectively. Ten Extra- procedures were required in 7 patients. There were no docking site procedures, non-union of regenerate, adjunctive stabilization after frame removal, recurrence of bone infection and recurrence of deformity.
Conclusions
Segmental resection and transport by TSF is an effective method to achieve length, alignment and eradicate infection. Although our cohort had longer external fixator indices than similar studies, the complication rate was low.