Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A
Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A
We compared the rate of revision of two classes of primary anatomic shoulder arthroplasty, stemmed (aTSA) and stemless (sTSA) undertaken with cemented all polyethylene glenoid components. A large national arthroplasty registry identified two cohort groups for comparison, aTSA and sTSA between 1. st. January 2011 and 31. st. December 2020. A sub-analysis from 1 January 2017 captured additional patient demographics. The cumulative percentage revision (CPR) was determined using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from
The 2021 Australian Orthopaedic Association National Joint Replacement Registry report indicated that total shoulder replacement using both mid head (TMH) length humeral components and reverse arthroplasty (RTSA) had a lower revision rate than stemmed humeral components in anatomical total shoulder arthroplasty (aTSA) - for all prosthesis types and diagnoses. The aim of this study was to assess the impact of component variables in the various primary total arthroplasty alternatives for osteoarthritis in the shoulder. Data from a large national arthroplasty registry were analysed for the period April 2004 to December 2020. The study population included all primary aTSA, RTSA, and TMH shoulder arthroplasty procedures undertaken for osteoarthritis (OA) using either cross-linked polyethylene (XLPE) or non-cross-linked polyethylene (non XLPE). Due to the previously documented and reported higher revision rate compared to other anatomical total shoulder replacement options, those using a cementless metal backed glenoid components were excluded. The rate of revision was determined by Kaplan-Meir estimates, with comparisons by
Strategy regarding patella resurfacing in total knee replacement (TKR) remains controversial. TKR revision rates are reportedly influenced by surgeon procedure volume. The study aim was to compare revision outcomes of TKR with and without patella resurfacing in different surgeon volume groups using data from the AOANJRR. The study population included 571,149 primary TKRs for osteoarthritis. Surgeons were classified as low, medium, or high-volume based on the quartiles of mean primary TKR volume between 2011 and 2020. Cumulative percent revision (CPR) using Kaplan-Meier estimates of survivorship were calculated for the three surgeon volume groups with and without patella resurfacing.
The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the long-term survival of this stem and analyze patients who underwent aseptic revision to understand the causes and risk factors for failure. A retrospective review was undertaken of all patients who received a primary total hip arthroplasty with an Accolade® TMZF stem at a high-volume arthroplasty center. The causes and timing of revision surgery were documented and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to minimize loss to follow-up. Survivorship analysis was performed with use of the Kaplan-Meier curves to determine the overall and aseptic survival rates at final follow-up. Patient and implant factors commonly associated with aseptic failure were extracted and
Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from
Total hip arthroplasty (THA) is an effective treatment for symptomatic hip osteoarthritis (OA). Computer-navigation technologies in total knee arthroplasty show evidence-supported survivorship advantages and are used widely. The aim of this study was to determine the revision outcome of hip commercially available navigation technologies. Data from the Australian Orthopaedic Association National Joint Replacement Registry from January 2016 to December 2020 included all primary THA procedures performed for osteoarthritis (OA). Procedures using the Intellijoint HIP® navigation were identified and compared to procedures inserted using ‘other’ computer navigation systems and to all non-navigated procedures. The cumulative percent revision (CPR) was compared between the three groups using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from
Background. Treatment of staphylococcal prosthetic joint infection (PJI) usually consists of surgical debridement and prolonged rifampicin combination therapy. Tailored antimicrobial treatment alternatives are needed due to frequent side effects and drug-drug interactions with rifampicin combination therapy. We aimed to assess the effectiveness of several alternative antibiotic strategies in patients with staphylococcal PJI. Methods. In this prospective, multicenter registry-based study, all consecutive patients with a staphylococcal PJI, treated with DAIR or one-stage revision surgery between January 1. st. , 2015 and November 3. rd. , 2020, were included. Patients were treated according to a predefined protocol for PJI. Antimicrobial treatment strategies differed between centers, which was accepted and used as pseudorandomization. Depending on the hospital patients were admitted to, they were treated with either a long-term rifampicin strategy (consisting of 12 weeks rifampicin combination therapy) ore one of several short-term rifampicin strategies, consisting of only five days of rifampicin combination treatment, started immediately postoperative, followed by clindamycin, flucloxacillin or vancomycin monotherapy. Patients were stratified in different groups, depending on the used antimicrobial strategy.
During total knee arthroplasty (TKA), a tourniquet is often used intraoperatively. There are proposed benefits of tourniquet use including shorter duration of surgery, improved surgical field visualization and increased cement penetration which may improve implant longevity. However, there are also cited side effects that include increased post-operative pain, slowed recovery, skin bruising, neurovascular injury and quadriceps weakness. Randomized controlled trials have demonstrated no differences in implant longevity, however they are limited by short follow-up and small sample sizes. The objective of the current study was to evaluate the rates of revision surgery among patients undergoing cemented TKA with or without an intraoperative tourniquet and to understand the causes and risk factors for failure. A retrospective cohort study was undertaken of all patients who received a primary, cemented TKA at a high-volume arthroplasty centre from January 1999 to December 2010. Patients who underwent surgery without the use of a tourniquet and those who had a tourniquet inflated for the entirety of the case were included. The causes and timing of revision surgery were recorded and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to reduce the loss to follow-up. Survivorship analysis was performed with the use of Kaplan-Meier curves to determine overall survival rates at final follow-up. A
Total hip arthroplasty (THA) is one of the most successful and effective treatments for advanced hip osteoarthritis (OA). Over the last 5 years, Canada has seen a 17.8% increase in the number of hip replacements performed annually, and that number is expected to grow along with the aging Canadian population. However, the rise in THA surgery is associated with an increased number of patients at risk for the development of an infection involving the joint prosthesis and adjacent deep tissue – periprosthetic joint infections (PJI). Despite improved hygiene protocols and novel surgical strategies, PJI remains a serious complication. No previous population-based studies has investigated PJI risk factors using a time-to-event approach and none have focused exclusively on patients undergoing THA for primary hip OA. The purpose of this study is to determine risk factors for PJI after primary THA for OA using a large population-based database collected over 15 years. Our secondary objective is to determine the incidence of PJI, the time to PJI following primary THA, and if PJI rates have changed in the past 15 years. We performed a population-based cohort study using linked administrative databases in Ontario, Canada in accordance with RECORD and STROBE guidelines. All primary total hip replacements performed for osteoarthritis in patients aged 55 or older between January 1st 2002 – December 31st 2016 in Ontario, Canada were identified. Periprosthetic joint infection as the cause for revision surgery was identified with the International Classification of Diseases, 10th Edition (ICD-10), Clinical Modification diagnosis code T84.53 in any component of the healthcare data set. Data were obtained from the Institute for Clinical Evaluative Sciences (ICES). Demographic data and outcomes are summarized using descriptive statistics. We used a
Population-based studies from the United States have reported that sarcoma patients living in rural areas or belonging to lower socioeconomic classes experience worse overall survival; however, the evidence is not clear for universal healthcare systems where financial resources should theoretically not affect access to standard of care. The purpose of this study was to determine the survival outcomes of soft-tissue sarcoma (STS) patients treated in Ontario, Canada over 23 years and determine if the patient's geographic location or income quintile are associated with survival. We performed a population-based cohort study using linked administrative databases of patients diagnosed with STS between 1993 – 2015. The Kaplan-Meier method was used to estimate 2, 5, 10, 15 and 20-year survival stratified by age, stage and location of tumor. We estimated survival outcomes based on the patient's geographic location and income quintile. The Log-Rank test was used to detect significant differences between groups. If groups were significantly different, a
Displaced femoral neck fractures can have devastating impacts on quality of life and patient function. Evidence for optimal surgical approach is far from definitive. The Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemi-Arthroplasty (HEALTH) trial aimed to evaluate unplanned secondary procedures following total hip arthroplasty (THA) versus hemi-arthroplasty (HA) within two years of initial surgery for displaced femoral neck fractures. Secondary objectives evaluated differences in patient function, health-related quality of life, mortality, and hip-related complications HEALTH is a large randomized controlled trial that included 1,495 patients across 81 centers in 10 countries. Patients aged 50 years or older with displaced femoral neck fractures received either THA or HA. Participants were followed for 24 months post-fracture and a Central Adjudication Committee adjudicated fracture eligibility, technical placement of prosthesis, additional surgical procedures, hip-related complications, and mortality. The primary analyses were a
Introduction. Infection remains a serious complication following primary total hip arthroplasty (THA). Many factors including primary diagnosis, comorbidities and duration of procedure are known to influence the rate of infection. Although the association between patient and surgical factors is increasingly well understood, little is known about the role of the prosthesis. This analysis from the Australian Registry (AOANJRR) was undertaken to determine if revision for infection varied depending on the type of bearing surface used. Methods. Three different bearing surfaces, ceramic on ceramic (CoC), ceramic on cross-linked polyethylene (CoXP) and metal on cross-linked polyethylene (MoXP) were compared. The study population included all primary THA undertaken for OA using these bearing surfaces and reported to the AOANJRR between 1999 and 2013. Kaplan-Meier survivorship curves were compiled with revision for infection as the end point. Hazard Ratios (HR) from
Purpose. Due to the aging population, an increasing proportion of elderly patients with soft tissue sarcoma are presenting to cancer centers. This population appears to have a worse prognosis but the reasons for this has not been studied in depth. The purpose of this study is to examine the effect of age on the outcome of patients with extremity and trunk soft tissue sarcoma. Method. This is a multicenter study including 2071 patients with median age at operation of 57 years (1st quartile–3rd quartile: 42–70). The endpoints considered were local recurrence and metastasis with death as a competing event.
Introduction. National Institute for Health and Clinical Excellence (NICE) guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractured neck of femur (NOF) in cognitively intact patients who were independently mobile prior to the injury. The National Joint Registry for England and Wales (NJR) has collected data on THRs performed since 2003. This retrospective cohort study explores risk factors independently associated with implant failure and perioperative mortality. Methods. NJR data recording a THR performed for acute fractured NOF between 2003 and 2010 were analysed.
Total knee replacement (TKR) is one of the most successful procedures in orthopaedic surgery. Although originally limited to more elderly and less active individuals, the inclusion criteria for TKR have changed, with ever younger, more active and heavier patients receiving TKR. Initially, tibial components were cemented all-polyethylene monoblock constructs. Subsequent long-term follow-up studies of these implants have demonstrated excellent durability in survivorship studies out to 20 years. Aseptic loosening of the tibial component was one of the main causes of failure in these implants. Polyethylene wear with osteolysis around well-fixed implants was rarely (if ever) observed. Cemented metal-backed nonmodular tibial components were subsequently introduced to allow for improved tibial load distribution and to protect osteoporotic bone. Long-term studies have established that many one-piece nonmodular tibial components have maintained excellent durability. Eventually, modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80s mainly to facilitate screw fixation for cementless implants. These designs also provided intra-operative versatility by allowing interchange of various polyethylene thicknesses, and also aided the addition of stems and wedges. Other advantages included the reduction of inventory, and the potential for isolated tibial polyethylene exchanges. Since the late 1980's, the phenomena of polyethylene wear and osteolysis have been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of synovitis, progressive osteolysis, and severe polyethylene wear remain unclear, but there is no question that it was associated with the widespread use of both cementless and cemented modular tibial designs. Mayo Data: Modular versus All Polyethylene Tibial Components in Primary TKA: The study population included 10,601 adult (>18 years) patients with 14,524 primary TKR procedures performed at our institution between 1/1/1988 and 12/31/2005. Mean age was 68.7 years and 55% were female. Overall revision rates and revisions for loosening, wear/osteolysis were compared across different designs using
Purpose. The optimal sequencing of radiotherapy (RT) with surgery in soft-tissue sarcomas (STS) remains undefined. We assessed the impact of RT sequencing on overall survival (OS), cause-specific survival (CSS), local failure, and distant failure. Methods. A retrospective analysis was conducted using the National Oncology Database, a proprietary database of aggregated tumour registries owned by Impac. (r). Medical Systems (Sunnyvale, CA). Eligible sites were soft tissues of the head/neck, thorax, abdomen, pelvis, extremities, trunk, and peritoneum. Only patients with known stage and grade were included. Prognostic factors were identified with multivariate analysis (MVA) using the
Introduction. Following in-depth analysis of the market leading brand combinations in which we identified implant influences on risk of revision, we compared revision in patients implanted with different categories of hip replacement in order to find implant with the lowest revision risk, once known flawed options were removed. Methods. All patients with osteoarthritis who underwent a hip replacement (2003–2010) using an Exeter-Contemporary (cemented), Corail-Pinnacle (cementless), Exeter-Trident (Hybrid) or a Birmingham Hip resurfacing (BHR) were initially included within the analysis. Operations involving factors that were significant predictors of revision were excluded.
Based on numerous national registries, cemented hip replacements have globally better long-term results than uncemented hip replacements. For example, following data have been published in national registries:. These registries demonstrated clearly that cemented fixation should be definitively preferred than uncemented fixation… Despite this evidence, uncemented fixation is more and more used in the majority of the countries performing total hip replacements. A recent paper analysed the Swedish situation and may give some reasons for explaining this paradox. A