Introduction. To determine the advantages and risks of plating after lengthening (PAL) of tibia in children and adolescents. Materials and Methods. 35 consecutive tibial lengthenings were done for limb length discrepancy (LLD) in 26 patients. Gradual lengthening by an external fixator from a tibial (usually diaphyseal) osteotomy was followed by internal fixation with a lateral tibial submuscular plate. The mean age at the time of the lengthening was 10.3 years (4.8 – 16.8 years). The aetiology for LLD was congenital in 21, acquired in 3, and developmental in 2 patients. The mean follow-up was 4.3 years (8 months – 9.9 years). Results. The mean lengthening was 5cm (3–8.6cm) or 19.1% (10.8 – 35.2%) of the initial length of tibia. It took 78.8 days to reach the target length at a lengthening rate of 0.75mm/day. The mean time to plate substitution after cessation of lengthening was 24.7days/109 days after osteotomy. This led to an average external fixation index (EFI) of 23.1days/cm. Optimisation of this technique by judicious estimation of timing of plate substitution would reduce the EFI.
To study the incidence of delayed consolidation of regenerate in children undergoing correction or lengthening of lower limb deformities using an external fixator. Between 2006 and 2011, 150 patients with lower limb deformities (excluding feet) were treated in our unit using external fixators. A retrospective review of our prospective database was carried out to identify patients with poor regenerate formation requiring bone grafting. Patients with acute fractures, pseudarthrosis of the tibia due to neurofibromatosis and those above the age of eighteen were excluded. An independent observer reviewed the medical records and radiographs. Eleven patients with ages ranging from 2 years 5 months to 17 years 5 months (mean average 9 years 9 months) formed the basis of our study – 3 males and 8 females. Factors that were associated with this complication include age greater than twelve years (10 patients), lack of weight bearing (6 patients), previous fixator (5 patients) and smoking (5 patients). The regenerate was deficient in nine tibial segments and two femoral segments. Six of the deficient tibial regenerates were at a proximal site whilst three were distal. There was no significant difference in length gained between these sites (p < 0.5). The mean time to regenerate bone grafting was 7 months. Time to healing following bone grafting was 2.5 months.Purposes of the Study
Methods and Results
Introduction. The use of vascularised fibula grafts is an accepted method for reconstructing the distal femur following resection of malignant childhood tumours. Limitations relate to the mismatch of the cross-sectional area of the transplanted fibula graft and thel ocal bone, instability of the construct and union difficulties. We present midterm results of a unique staged technique—an immediate defect reconstruction using a double-barrel vascularised fibula graft set in in A-frame configuration and a subsequent intramedullary femoral lengthening. Materials & Methods. We retrospectively included 10 patients (mean age 10 y)with an osteosarcoma of the distal femur, who were treated ac-cording to the above-mentioned surgical technique. All patients were evaluated with regards to consolidation of the transplanted grafts, hypertrophy at the graft-host junctions, leg length discrepancies, lengthening indices, complications as well as functional outcome. Results. The mean defect size after tumour resection was 14.5 cm, the mean length of the harvested fibula graft 22 cm, resulting in a mean (acute) shortening of 4.7 cm (in 8 patients).
Introduction. Acetabular revision surgery is challenging due to severe bone defects. Burch-Schneider anti-protrusion cages (BS cage: Zimmer-Biomet) is one of the options for acetabular revision, however higher dislocation rate was reported. A computed tomography (CT)-based navigation system indicates us the planned direction for implantation of a cemented acetabular cup during surgery. A large diameter femoral head is also expected to reduce the dislocation rate. The purpose of this study is to investigate short-term results of BS cage in acetabular revision surgery combined with the CT-based navigation system and the use of large diameter femoral head. Methods. Sixteen hips of fifteen patients who underwent revision THA using allografts and BS cage between September 2013 and December 2017 were included in this study with the follow-up of 2.7 (0.1–5.0) years. There were 12 women and three men with a mean age of 78.6 years (range, 59–61 years). The cause of acetabular revision was aseptic loosening in all hips. The failed acetabular cup was carefully removed, and acetabular bone defect was graded using the Paprosky classification. Structural allografts were morselized and packed for all medial or contained defects. In some cases, solid allograft was implanted for segmental defects. BS cage was molded to optimize stability and congruity to the acetabulum and fixed with 6.5 mm titanium screws to the iliac bone. The inferior flange was slotted into the ischium. The upside-down trial cup was attached to a straight handle cup positioner with instrumental tracker (Figure 1) and placed on the rim of the BS cage to confirm the direction of the target angle for cement cup implantation under the CT-based navigation system (Stryker). After removing the cement spacer around the X3 RimFit cup (Stryker) onto the BS cage for available maximum large femoral head, the cement cup was implanted with confirming the direction of targeting angle. Japanese Orthopedic Association score (JOA score) of the hip was used for clinical assessment. Implant position, loosening, and consolidation of allograft were assessed using anterior and lateral radiographies of the pelvis. Results. Fifteen hips had a Paprosky IIIB defect, and one hip had a pelvic discontinuity. JOA score significantly improved postoperatively. No radiolucent lines and no displacement of BS cage could be found in 9 of 15 hips.
The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device. This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies.Aims
Methods
Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator. A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.Aims
Patients and Methods
We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.
Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.