Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 10 - 10
1 Feb 2020
Clark A Hounat A MacLean A Jones B Blyth M
Full Access

We report on the 5 year results of a randomized study comparing TKR performed using conventional instrumentation versus electromagnetic computer-assisted surgery. This study analysed patient reported outcome measures (PROMs) at 5 years utilising the American Knee Society Score (AKSS), Oxford Knee Score (OKS), the Short Form 36 score and range of motion (ROM). Of the 200 patients enrolled 125 completed 5 year follow up, 62 in the navigated group and 63 in the conventional group. There were 28 deceased patients, 29 withdrawals and 16 lost to follow-up. There was improvement in clinical function in most PROMs from 1-5 year follow up across both groups. OKS improved from a mean of 26.6 (12–55) to 35.1 (5–48). AKSS increased from 75.3 (0–100) to 78.4 (−10–100), SF36 from 58.9 (2.5–100) to 53.2 (0–100). ROM improved by an average 7 degrees from 110 degrees to 117 degrees (80–135). There was no statistically significant difference in PROMs between the groups at 5 years. Patients undergoing revision surgery were identified from the dataset and global PACS. There were no revisions within 5 years in the navigated group and 3 revisions in the conventional group, two for infection and one for mid-flexion instability, giving an all cause revision rate of 3.06% at 5 years for this group. There appears to be no significant advantage in clinical function for patients undergoing TKR for OA of the knee with electromagnetic navigation when compared to conventional techniques. There may be an advantage in reducing early revision rates using this technology


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 374 - 374
1 Sep 2012
Köhler D Pohlemann T Culemann U
Full Access

Background. The suicidal jumper's fracture of the pelvis is a special form of sacrum fractures associated with high energy trauma. The typical H-type fracture pattern runs transforaminal on both sides with a connecting transverse component between S1 and S3. Due to the high-grade instability operative treatment is imperative. Aim of this study was to compare iliosacral double screwing (2×7,3mm canulated screw with 16mm thread) with spinopelvic internal fixation. Methods. Both methods were tested on 6 synthetic and 6 anatomical pelvises. After osteotomy and alternating osteosynthesis stability was tested with a universal testing machine (Zwick) in a simulated two-leg stand. Data were generated by a 3-dimensional computer-assisted ultrasoundsystem (Zebris©) (3 translational datasets x,y,z and 3 ankles). Testing was performed after preload of 50N and two setting cycles of 100N followed by a full load cycle of 150N. ASCII-data were then transferred to SPSS for statistical analysis. Results. Both experimental series showed similar results. There was a tendancy of less displacement when iliosacral screwing was performed. However, no statistical significance could be observed between both techniques. Discussion. Although the spinopelvic internal fixation is a more rigid system, the double screwing may compensate this as it interacts in the center of the fracture. We therefore think that iliosacral double screwing is an appropriate technique for stabilisation of this special fracture type. The possibility of percutaneous osteosynthesis and of its performance in a supine position, this procedure provides essential advantages for the operative treatment of polytraumatized patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 214 - 214
1 Sep 2012
Beaulé P White C Lopez-Castellaro J Kim P
Full Access

Introduction. Although femoral neck fractures remain a concern in short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. This study aimed to evaluate the migration pattern of a cobalt chrome, beaded acetabular component for a metal on metal hip resurfacing. Methods. 130 patients underwent metal on metal hip resurfacing: 66 hips in 60 patients had sufficient films to be included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the procedures were performed for osteoarthritis. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement. Results. At a mean follow up 25.3 months (24–36 months), each hip had an average of 5.1 radiographs for analysis. 12.5% of the cups showed more than 1 mm migration in the medial-lateral axis and 45.3% more than 1 mm in the vertical axis. 23% of the cups showed a combined migration of greater than 2 mm in the observation period. Two of these cases required revision for aseptic loosening at 34 months. Discussion and Conclusion. Previous studies have shown EBRA to have an excellent sensitivity and positive predictive value for mid to long term cup failure. This data raises concern about the initial stability if this acetabular component. Continued follow-up is needed to monitor the longer term survival of this implant


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 342 - 342
1 Sep 2012
Migaud H Marchetti E Combes A Puget J Tabutin J Pinoit Y Laffargue P
Full Access

Introduction. The same cup orientation is classically applied to all cases of hip replacement (45° abduction, 20° anteversion). We hypothesize that this orientation must be adapted to the patient's hip range of motion. We tested this hypothesis by means of an experimental study with respect to hip range of motion, comparing the classical orientation (45° and 20°), and the orientation obtained with computer-assisted navigation. Material and Methods. The experimental model included a hemipelvis equipped with a femur whose mobility was controlled for three configurations: stiff (60°/0°, 15°/10°, 10°/10°), average (80°/10°, 35°/30°,35°/25°), mobile (130°/30°, 50°/50°, 45°/35°). The hemipelvis and the cup holder were equipped with an electromagnetic system (Fastrack ™) to measure cup orientation. The Pleos™ navigation system (equipping the hemipelvis, the femur, and the cup holder) guided the cup orientation by detecting the positions risking impingement through a kinematic study of the hip. Nine operators each performed 18 navigation-guided implantations (162 hip abduction, anteversion, and range of movement measurements) in two series scheduled 2 months apart. Results. The model used herein showed intra and interobserver reliability. Compared to the navigation-assisted surgery, the arbitrary orientation gave a mean anteversion error of only 1° ± 6° (−12 to +19°) but 5° ± 8° (−26° to +13°) for abduction. However, 16% of the errors were more than 10° in anteversion (1/2 in the mobile configuration) and 11% of the errors were more than 15° in abduction (for the most part in the mobile configuration). With arbitrary orientation, the errors consisted in excess anteversion and insufficient abduction. Discussion and Conclusion. The experimental model developed was reliable and can be used to evaluate different prosthetic configurations. This study emphasizes that the ideal arbitrary cup orientation cannot be applied to all hips. All the surgeons are very reproducible but the only way to integrate the range of motion in there ‘own way to do’ in vitro, is to use a navigation system witch can guide the surgeon so as to reduce the risk of impingement and instability


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 340 - 340
1 Sep 2012
Migaud H Marchetti E Bocquet D Krantz N Berton C Girard J
Full Access

Introduction. The prosthetic impingement occurs if the range of motion of the hip exceeds implant mobility or in case of component malorientation. This retrieval study was designed to assess the frequency and the risk factors of this phenomenon. Material and Methods. The frequency and the severity of the impingement were calculated from a continuous series of 311 cups retrievals collected between 1989 and 2004 by a single surgeon. The reason for retrieval was loosening (131 cases), infection (43 cases), instability (56 cases), osteolysis (28 cases), unexplained pain (48 cases) and prosthetic impingent (5 cases all with hard bearings). The notching at the cup rim was assessed twice by two examiners with optic magnification. The risk factors were analyzed from clinical charts by univariate and cox multihazard. Results. Among the 311 cups explants, the frequency of impingement was 59.2% (it was severe in 11%, the notching exceeding 3 millimeters). The impingement was the reason for removal in only 1.6%, meaning that it was mainly unexpected (98.4 percent). The impingement was more frequent when revisions were performed because of instability (notching 80%), when the sum of hip motion exceeded 200 degrees (sum of motion in the 6 degrees of freedom of the hip) (notching 66%). The other risk factors were: use of heads with skirts, liner with an elevated rim, and head-neck ratio below 2, younger age at surgery. The multivariate analysis identified only two independent factors: 1) the use of skirted heads (Odd ratio 3.2 (1.2–15.3)), 2) and revision because of instability (Odd ratio 4.2 (1.1–16.2)). In contrast different classical factors were not correlated with impingement on retrieval: cup inclination, the duration before retrieval, the indication for primary prosthetic replacement. Discussion and Conclusion. This study underlines the impingement is common when assessing cup retrievals (over 50 percent). One should be aware of impingement when performing hip replacement in patients having a high range of motion. This situation may require prostheses with a high head-neck ratio, as well as use of computer-assisted surgery. One should avoid liners with elevated rim as well as heads with skirts to prevent dislocation, particularly when other risk factors are detected


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 55 - 55
1 Sep 2012
Martin A Cip J Mayr E Benesch T Waibel R Von Strempel A Widemschek M
Full Access

Background. Computer-assisted navigation systems for total knee arthroplasty (TKA) were introduced to improve implantation accuracy and to optimize ligament balancing. Several comparative studies in the literature confirmed an effect on the component position and other studies could not confirm these results. For ligament balancing most studies found no significant influence on the clinical outcome using a navigation system for TKA. In the literature there were no reports of mid-term results after navigated TKA. With our study we wanted to show if the use of a navigation system for TKA will have an influence on the component's position and on the clinical results at 5-year follow up. Methods. We enrolled 200 patients in a prospective randomized study with a minimum follow up of 5 years. 100 TKA were operated on without using a navigation system (Group A) and 100 surgeries (Group B) were done with computer assistance. Radiological investigation by standard radiographs including a long-leg X-ray was performed with a follow up rate in Group A of 86.2% versus 80.2% in Group B. We measured the mechanical axis of the leg, lateral distal femoral angel (LDFA), medial proximal tibial angle (MPTA), tibial slope and the alpha-angle of the patella. Clinical investigation was performed with a follow up rate in Group A of 85.7% versus 79.8% in Group B including the parameters for the range of motion (ROM), ligament balancing, anterior drawer test, feeling of instability, anterior knee pain, effusion, WOMAC Score, Insall Score and HSS Knee Score. Results. In both groups there was no aseptic loosening or difference in TKA survival rate (Group A 95.4% versus Group B 98.85% 5-year survival rate, p = 0.368). With the navigation technique the mechanical axis of the limb in the frontal plane was improved (p = 0.015; Group B: 1.67 ° ± 1.6° versus 2,44 ° ± 2.2 ° in Group A). 90% of the Group B and 81% of the Group A were within 3 ° varus/valgus deformity of the mechanical axis of the limb (p = 0.157). The accuracy of tibial slope was higher in the Group B (p = 0.001). More patients of the Group B (95% versus 79%) were within a deviation of 3 °, −7 ° tibial slope (p = 0.007). The mean deviation of 90 ° LDFA was higher (p = 0.034) in the Group A (1.89 ° versus 1.36 ° in Group B). Mean deviation of 90 ° MPTA, mean MPTA, mean LDFA and patella alpha angle were similar in both groups (p 0.253). There was no difference in ROM, ligament balancing, anterior drawer test, anterior knee pain or feeling of instability (p 0.058). Insall Knee Score total (181 Group A/191 Group B) and HSS Knee Score total (91 Group A/93 Group B) was higher with the navigated procedure in Group B (p 0.026). WOMAC total and HSS grades were similar in both groups (p 0.070). Conclusions. The accuracy of the mechanical axis of the limb and the tibial slope was higher with the navigated procedure. TKA survival rate and clinical outcomes were similar in both groups at 5-year follow up


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 378 - 386
1 Mar 2011
Foruria AM de Gracia MM Larson DR Munuera L Sanchez-Sotelo J

Our aim was to determine the effect of the initial pattern of fracture and the displacement of fragments on the outcome of proximal humeral fractures treated conservatively. We followed 93 consecutive patients prospectively for one year. Final movement and strength were compared with those of the contralateral side. The final American Shoulder and Elbow Society score and the Disabilities of Arm, Shoulder and Hand and Short-Form 36 questionnaires were compared with those provided by the patient on the day of the injury. Radiographs and CT scans with three-dimensional reconstruction were obtained in all patients. The pattern of the fracture and the displacement of individual fragments were analysed and correlated with the final outcome. There were two cases of nonunion and six of avascular necrosis. The majority of the fractures (84 patients; 90%) followed one of the following four patterns: posteromedial (varus) impaction in 50 patients (54%), lateral (valgus) impaction in 13 (14%), isolated greater tuberosity in 15 (16%), and anteromedial impaction fracture in six (6%). Head orientation, impaction of the surgical neck and displacement of the tuberosity correlated strongly with the outcome.

In fractures with posteromedial impaction, a poor outcome was noted as the articular surface displaced inferiorly increasing its distance from the acromion. A poorer outcome was noted as a fractured greater tuberosity displaced medially overlapping with the posterior articular surface. Lateral impaction fractures had a worse outcome than other patterns of fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1201 - 1207
1 Sep 2009
Lefaivre KA Starr AJ Barker BP Overturf S Reinert CM

We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta.

There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (sd 6.5). All but one patient had iliosacral screws implanted, 18 had screws in the anterior column, six had plates at the symphysis pubis and 12 had anterior external fixators. The mean maximum horizontal or vertical displacement was improved from 30.8 mm (sd 2.7) to a mean of 7.1 mm (sd 0.7). The reduction was assessed as excellent in ten patients, good in 18, and fair in the remainder. There was no significant influence on the quality of the reduction caused by obesity (p = 0.34), the type of fracture (p = 0.41) or delay to surgery (p = 0.83).

The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring.