As patient data continues to grow, the importance of efficient and precise analysis cannot be overstated. The employment of Generative Artificial Intelligence (AI), specifically Chat GPT-4, in the realm of medical data interpretation has been on the rise. However, its effectiveness in comparison to manual data analysis has been insufficiently investigated. This quality improvement project aimed to evaluate the accuracy and time-efficiency of Generative AI (GPT-4) against manual data interpretation within extensive datasets pertaining to patients with orthopaedic injuries. A dataset, containing details of 6,562 orthopaedic trauma patients admitted to a district general hospital over a span of two years, was reviewed. Two researchers operated independently: one utilised GPT-4 for insights via prompts, while the other manually examined the identical dataset employing Microsoft Excel and IBM® SPSS® software. Both were blinded on each other's procedures and outcomes. Each researcher answered 20 questions based on the dataset including injury details, age groups, injury specifics, activity trends and the duration taken to assess the data. Upon comparison, both GPT-4 and the manual researcher achieved consistent results for 19 out of the 20 questions (95% accuracy). After a subsequent review and refined prompts (prompt engineering) to GPT-4, the answer to the final question aligned with the manual researcher's findings. GPT-4 required just 30 minutes, a stark contrast to the manual researcher's 9-hour analytical duration. This quality improvement project emphasises the transformative potential of Generative AI in the domain of medical data analysis. GPT-4 not only paralleled the accuracy of manual analysis but also achieved this in significantly less time. For optimal accurate results, data analysis by AI can be enhanced through human oversight. Adopting AI-driven approaches, particularly in orthopaedic data interpretation, can enhance efficiency and ultimately improve patient care. We recommend future investigations on large and more varied datasets to reaffirm these outcomes.
The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.Aims
Methods
Two-stage exchange arthroplasty is traditionally used to treat periprosthetic hip infection. Nevertheless, particularly in high-risk patients, there has been increased attention towards alternatives such as 1.5-stage exchange arthroplasty which takes place in one surgery. Therefore, we sought to compare (1) operative time, length-of-stay (LOS), transfusions, (2) causative organism identification and polymicrobial infection rates, (3) re-revision rates and re-revision reasons, (4) mortality, and determine (5) independent predictors of re-revision. Retrospective chart review of 71 patients who underwent either 1.5- (n=38) or 2-stage (n=33) exchange hip arthroplasty at a single institution (03/2019-05/2023). Demographics, surgical, inpatient, and infection characteristics were noted. Main outcomes evaluated were re-revision rates, re-revision reasons, mortality, and cause of death. Independent predictors of re-revision were assessed utilizing logistic regression. Mean follow: 675 days (range, 23–1,715). Demographics were not significantly different except for a higher proportion of 1.5-stage patients classified as American-Society-of-Anesthesiologists (ASA) status 3 or 4 (84.2 vs. 48.5%, p=0.002). Length of follow-up was significantly longer in the 2-stage group (924.4 vs. 458 days, p<0.001) as well as operative time (506 vs. 271 minutes, p<0.001). In the 1.5-stage group, there was a higher proportion of polymicrobial infections (23.7 vs. 3.0%, p=0.016), re-revision rates (28.9 vs. 9.1%, p=0.042) and periprosthetic infections as a cause of revision (90.9 vs. 0%, p=0.007). Mortality rates were not significantly different, and no patient died for causes related to infection. Type of surgery (1.5-stage vs. 2-stage) was the only independent predictor of re-revision (odds-ratio 4.0, 95% confidence-interval 1.02–16.16, p=0.046). Our data suggests that patients who undergo 1.5-stage exchange arthroplasty have a significantly higher re-revision rate (mostly due to infection) when compared to 2-stage patients. We acknowledge potential benefits of the 1.5-stage strategy, especially in high-risk patients since it involves single surgery. However, higher re-revision rates must be considered when counseling patients.
Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis.Aims
Methods
In the early 2000s hip resurfacing became an established bone conserving hip arthroplasty option particularly for the fit and active patient cohort. The performance of second-generation metal-on-metal bearings had led to the reintroduction of hip resurfacing. The Birmingham Hip resurfacing (BHR) was introduced in 1997. This was followed by a number of different designs of the hip resurfacing. The Durom hip resurfacing was introduced in 2001. These two designs had different metallurgical properties, design parameters particularly clearance and different implantation techniques. Data from joint registries show that both prosthesis perform well. Our objective was to perform a retrospective survival analysis comparing the Birmingham to the Durom hip resurfacing and analyse the mode of failures of the cases revised.Introduction
Objectives
Hip fractures are associated with poor outcomes and high mortality rates of 30%. The current gold standard to measure bone fragility is a Dual-Energy X-ray Absorptiometry (DEXA) scan measuring bone mineral density. Yet DEXA under-diagnoses bone fragility by 50% (1). To combat the burden of bone fragility, this experimental study combined ultrasound (US) with a sophisticated computational algorithm, namely full wave inversion (FWI), to evaluate femoral bone structure. The aims were to assess the association of bone structure between the proximal femoral diaphysis and femoral neck; secondly to evaluate whether transverse ultrasound could assess bone structure of the proximal femoral diaphysis. Bone structure of 19 ex vivo human femora was assessed by micro-CT analysis (mean age 88.11 years, male:female 13:6)(Nikon HMXST 225). Using ImageJ/BoneJ, three 10.2mm subsections of proximal diaphysis and femoral neck underwent analysis: the total bone volume fraction, cortical parameters (bone volume fraction, porosity, thickness) and trabecular parameters (porosity, thickness, spacing and connectivity). A unique US prototype was developed to analyse fifteen femoral diaphyseal subsections using two P4-1 transducers with a novel tomography sequence (Verasonics, Matlab ver R2019a, FWI TRUST protocol).
Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs). In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.Aims
Methods
Some patients presenting with hip pain and instability and underlying acetabular dysplasia (AD) do not experience resolution of symptoms after surgical management. Hip-spine syndrome is a possible underlying cause. We hypothesized that there is a higher frequency of radiological spine anomalies in patients with AD. We also assessed the relationship between radiological severity of AD and frequency of spine anomalies. In a retrospective analysis of registry data, 122 hips in 122 patients who presented with hip pain and and a final diagnosis of AD were studied. Two observers analyzed hip and spine variables using standard radiographs to assess AD. The frequency of lumbosacral transitional vertebra (LSTV), along with associated Castellvi grade, pars interarticularis defect, and spinal morphological measurements were recorded and correlated with radiological severity of AD.Aims
Methods
The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach. A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups.Aims
Methods
Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL measurements may differ by > 10° from CT scan measurements but the reasons for this discrepancy are poorly understood. Anteversion measurements from CTL radiographs and CT scans are compared to identify spinopelvic parameters predictive of inaccuracy. THA patients (n = 47; 27 males, 20 females; mean age 62.9 years (SD 6.95)) with preoperative spinopelvic mobility, radiological analysis, and postoperative CT scans were retrospectively reviewed. Acetabular component anteversion was measured on postoperative CTL radiographs and CT scans using 3D reconstructions of the pelvis. Two cohorts were identified based on a CTL-CT error of ≥ 10° (n = 11) or < 10° (n = 36). Spinopelvic mobility parameters were compared using independent-samples Aims
Methods
Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement.Aims
Methods
The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.Objectives
Patients and Methods
Femoroacetabular impingement (FAI) causes pain
and chondrolabral damage via mechanical overload during movement
of the hip. It is caused by many different types of pathoanatomy,
including the cam ‘bump’, decreased head–neck offset, acetabular
retroversion, global acetabular overcoverage, prominent anterior–inferior
iliac spine, slipped capital femoral epiphysis, and the sequelae
of childhood Perthes’ disease. Both evolutionary and developmental factors may cause FAI. Prevalence
studies show that anatomic variations that cause FAI are common
in the asymptomatic population. Young athletes may be predisposed
to FAI because of the stress on the physis during development. Other
factors, including the soft tissues, may also influence symptoms and
chondrolabral damage. FAI and the resultant chondrolabral pathology are often treated
arthroscopically. Although the results are favourable, morphologies
can be complex, patient expectations are high and the surgery is
challenging. The long-term outcomes of hip arthroscopy are still
forthcoming and it is unknown if treatment of FAI will prevent arthrosis.
The purpose of this study was to define immediate post-operative ‘quality’ in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.