Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator cuff repair. The study was designed as a retrospective comparative study on prospectively collected data from a consecutive cohort of patients. All patients who underwent arthroscopic revision rotator cuff repair for symptomatic failure of previous posterosuperior rotator cuff repair were considered eligible for the study. Symptomatic failure had been diagnosed according to clinical examination and confirmed by magnetic resonance imaging (MRI). Structural integrity had been assessed on MRI and classified according to Sugaya classification. Only patients affected by stage IV-V were considered eligible. Tear reparability was confirmed during arthroscopy. Only patients with a minimum 2 years follow-up were included. Patients were divided in two groups. In group 1 (control group) a standard arthroscopic revision and microfractures of the greater tuberosity were performed; in group 2 (experimental group), microfractures of the greater tuberosity and a ECM patch graft were used to enhance tendon repair, followed by postoperative PC injections. Minimum follow-up was 12 months. Primary outcome was the Constant-Murley score (CMS) normalized for age and gender. Subjective outcome was assessed with the Disabilities of the Arm, Shoulder and Hand (DASH) score in its short version (Quick-DASH). Tendon integrity was assessed with MRI at 6 months after surgery. Comparison between groups for all discrete variables at baseline and at follow-up was carried out with the Student's t-test for normally distributed data, otherwise Mann-Whitney U-test was used. Within-group differences (baseline vs follow-up) for discrete variables were analyzed by paired t-test, or by Wilcoxon signed-rank test in case of data with non-normal distribution. Differences for categorical variables were assessed by chi-squared test. Significance was considered for p values < 0.05. Forty patients were included in the study (20 patients for each group). The mean follow-up was 13 ± 1.6 months. No patients were lost at the follow up. Comparison between groups did not show significant differences for baseline characteristics. At follow-up, mean CMS was 80.7 ± 16.6 points in group 1 and 91.5 ± 11.5 points in group 2 (p= 0.022). Mean DASH score was 28.6 ± 21.6 points in group 1 and 20.1 ± 17.4 points in group 2 (p= 0.178). Post-operative MRI showed 6 healed shoulders in Group 1 and 16 healed shoulders in Group 2 (p<0.004). No postoperative complications were reported in both groups. The combination of microfractures of the greater tuberosity, ECM patch graft, and subsequent PC subacromial injections is an effective strategy in improving tendon healing rate.
Surgical debridement for medial epicondylitis (ME) is indicated for patients with refractory ME. The clinical efficacy of simple debridement has not been studied sufficiently. Moreover, authors experienced surgical outcome of ME was not as good as lateral epicondylitis. In this regard, authors have combined the atelocollagen injection in the debridement surgery of ME. The purpose of study was to compare clinical outcomes between simple debridement and debridement combined with atelocollagen injection in the ME. Twenty-five patients with refractory ME and underwent surgical debridement were included in the study. Group A (n=13) was treated with isolated debridement surgery, and group B (n=12) was treated with debridement combined with 1.0 mL of type I atelocollagen. Pain and functional improvements were assessed using visual analogue scale, Mayo Elbow Performance Score (MEPS) and quick Disabilities of the Arm, Shoulder and Hand (DASH) scale respectively before surgery, at 3, 6 months after surgery and at the final follow-up. Demographic data did not show significant difference between two groups before surgical procedures. Both groups showed improvement in pain and functional score postoperatively. However, at the 3 months after surgery, group B showed significantly better improvement as compared to group A(VAS 3.1 / 2.0, MEPS 71/82 qDASH 29/23). At the 6 months after surgery and final follow-up, both groups did not show any difference. Surgical debridement combined with atelocollagen is effective treatment option in refractory ME and showed better short-term outcomes compared to isolated surgery.
Summary. From a large 3D Caucasian bone data base, female population had significantly larger acetabular anatomical anteversion angle and combined acetabular-femoral anteversion angle than that of male population. There was no significant difference in femoral neck anteversion angles between the groups. Introduction.
Critical size bone defects are frequently caused by accidental trauma, oncologic surgery, and infection. Distraction osteogenesis (DO) is a useful technique to promote the repair of critical size bone defects. However, DO is usually a lengthy treatment, therefore accompanied with increased risks of complications such as infections and delayed union. Herein, we developed an innovative intramedullary biodegradable magnesium (Mg) nail to accelerate bone regeneration in critical size bone defect repair during DO. We observed that Mg nail induced almost 4-fold increase of new bone formation and over 5-fold of new vessel formation at 2 weeks after distraction. Mg nail upregulated the expression of calcitonin gene-related peptide (CGRP) in the new bone as compared with the DO alone group. We further revealed that blockade of the sensory nerve by overdose capsaicin blunted Mg nail enhanced critical size bone defect repair during the DO process. Moreover, inhibitors/antagonist of CGRP receptor, FAK, and VEGF receptor blocked the Mg nail stimulated vessel and bone formation. In summary, we revealed, for the first time, a CGRP-FAK-VEGF signaling axis linking sensory nerve and endothelial cells, which may be the main mechanism underlying Mg-enhanced critical size bone defect repair when combined with DO, suggesting a great potential of Mg implants in reducing DO treatment time for clinical applications.
Lesions in the joint surface are commonly treated with osteoarticular autograft transfer system (OATS), autologous cell implantation (ACI/MACI), or microfracture. Tissue formed buy the latter commonly results in mechanically inferior fibrocartilage that fails to integrate with the surrounding native cartilage, rather than durable hyaline cartilage. Fractional laser treatment to make sub-millimeter (<500 µm) channels has been employed for tissue regeneration in the skin to facilitate rejuvenation without typical scarring. Additionally, we have pioneered a means to generate articular cartilage matrix from chondrocytes—dynamic Self-Regenerating Cartilage (dSRC). Combining these two approaches by performing fractional laser treatment of the joint cartilage and treating with dSRC is a new paradigm for joint surface restoration. This approach was refined in a series of in vitro experiments and tested in swine knee defects during a 6-month study in 12 swine. dSRC are generated by placing 107 swine knee chondrocytes into sealed 15-mL polypropylene tubes and cultured on a rocker at 40 cycles per minute for 14 days at 37°C. The chondrocytes aggregate and generate new extracellular matrix to form a pellet of dSRC. Channels of approximately 300-500 µm diameter were created by infrared laser ablation in swine cartilage (in vitro) and swine knees (in vivo). The diameter and depth of the ablated channel in the cartilage was controlled by the light delivery parameters (power, spot size, pulse duration) from a fractional 2.94 µm Erbium laser. The specimens were evaluated with histology (H&E, safranin O, toluidine blue) and polarized-sensitive optical coherence tomography for collagen orientation. We can consistently create laser-ablated channels in the swine knee and successfully implant new cartilage from dSRC to generate typical hyaline cartilage in terms of morphology and biochemical properties. The neocartilage integrates with host cartilage in vivo. These findings demonstrate our novel combinatorial approach for articular cartilage rejuvenation.
The growing number of non-union fractures in an aging population has increased the clinical demand for tissue-engineered bone. Electrical stimulation (ES) has been described as a promising strategy for bone regeneration treatments in several clinical studies. However the underlying mechanism by which ES augments bone formation is still poorly understood and its use in bone tissue engineering (BTE) strategies is currently underexplored. Additive manufacturing (AM) technologies (Fused Deposition Modeling/3D Printing) have been widely used in BTE due to their ability to fabricate scaffolds with a high control over their structural and mechanical properties in a reproducible and scalable manner. Thus, in this work, we combined AM methods with conductive biomaterials and ES to enhance the osteogenic differentiation of human bone marrow-derived mesenchymal stem/stromal cells (hBMSCs) envisaging improved BTE strategies. First, we started by developing AM-based electro-bioreactor devices containing medical-grade electrodes (stainless steel and Ti6Al4V) to apply ES to monolayer 2D cultures and 3D cell-seeded scaffolds. Computer modeling(Finite Element Analysis-FEA) was employed to predict the magnitude/distribution of electrical fields within the ES devices and along the different conductive scaffolds. Prior to scaffold culture, 5 different ES protocols were tested in terms of their ability to promote hBMSCs proliferation and osteogenic differentiation in 2D cultures. The best performance ES protocol was then used in two different AM-based BTE strategies: 1) Two different conductive scaffolds (conductive poly lactic acid (PLA) and titanium) were seeded with hBMSCs and cultured for 21 days under osteogenic medium conditions with and without ES and their biological performance was evaluated in comparison to non-conductive standard PLA scaffolds; 2) Different PEDOT:PSS-based coating solutions were screened to obtain PEDOT:PSS/Gelatin-coated 3D polycaprolactone (PCL) scaffolds with a high(11 S.cm-1) and stable electroconductivity. When cultured under ES, PEDOT:PSS/Gelatin-PCL scaffolds enhanced significantly hBMSCs osteogenic differentiation and mineralization(calcium deposition), highlighting their potential for BTE applications.
Re-rupture rates after rotator cuff repair remain high because of inadequate biological healing at the tendon-bone interface. Single-growth factor therapies to augment healing at the enthesis have so far yielded inconsistent results. An emerging approach is to combine multiple growth factors over a spatiotemporal distribution that mimics normal healing. We propose a novel combination treatment of insulin-like growth factor 1 (IGF-1), transforming growth factor β1 (TGF-β1) and parathyroid hormone (PTH) incorporated into a controlled-release tyraminated poly-vinyl-alcohol hydrogel to improve healing after rotator cuff repair. We aimed to evaluate this growth factor treatment in a rat chronic rotator cuff tear model. A total of 30 male Sprague-Dawley rats underwent unilateral supraspinatus tenotomy. Delayed rotator cuff repairs were then performed after 3 weeks, to allow tendon degeneration that resembles the human clinical scenario. Animals were randomly assigned to: [1] a control group with repair alone; or [2] a treatment group in which the hydrogel was applied at the repair site. All animals were euthanized 12 weeks after rotator cuff surgery and the explanted shoulders were analyzed for biomechanical strength and histological quality of healing at the repair site. In the treatment group had significantly higher stress at failure (73% improvement, P=0.003) and Young's modulus (56% improvement, P=0.028) compared to the control group. Histological assessment revealed improved healing with significantly higher overall histological scores (10.1 of 15 vs 6.55 of 15, P=0.032), and lower inflammation and vascularity. This novel combination growth factor treatment improved the quality of healing and strength of the repaired enthesis in a chronic rotator cuff tear model. Further optimization and tailoring of the growth factors hydrogel is required prior to consideration for clinical use in the treatment of rotator cuff tears. This novel treatment approach holds promise for improving biological healing of this clinically challenging problem.
Hyaluronic acid (HA) is an effective option for the treatment of osteoarthritis (OA) patients due to several properties such as normalization of the mechanical and rheological properties of the synovial fluid and amelioration of OA symptoms and joints function by promoting cartilage nutrition. Since OA progression is also significantly related to oxidative stress and reactive oxygen species (ROS), sodium succinate (SS) is envisioned as a promising compound for cartilage treatment by providing antioxidant defense able to normalize intracellular metabolism and tissue respiration via mitochondrial mechanism of action. The scope of this study was to investigate on an in vitro inflammatory model the efficacy of Diart® product, a combination of HA and SS. Donor-matched chondrocytes and synoviocytes were obtained from KL 3–4 OA patients undergoing total knee replacement. At passage 4, inflammation was promoted with 1 ng/ml IL-1B for 48 hours in absence and presence of Diart® at 1:3 dilution rate. Nitric oxide (NO) from cell culture supernatant was measured by Griess reaction. Mitochondrial and cytoplasmatic ROS evaluation was assessed by flow cytometry with MitoSox and dichlorodihydrofluorescein diacetate (DCFDA) assays. Gene expression of inflammation/oxidative stress-related transcripts (MMP1/MMP3/INOS/COX2) was evaluated by qRT-PCR using TBP as reference.Introduction and Objective
Materials and Methods
Osteoporosis of the pelvis and femur is diagnosed in a high proportion of lower-limb amputees which carries an increased fracture risk and subsequently serious implications on mobility, physical dependency and morbidity. Through the development of biofidelic musculoskeletal and finite element (FE) models, we aim to determine the effect of lower-limb amputation on long-term bone remodelling in the hip and to understand the potential underpinning mechanisms for bone degradation in the younger amputee population. Our models are patient specific and anatomically accurate. Geometries are derived from MRI-scans of one bilateral, above-knee, amputee and one body-matched control subject. Musculoskeletal modelling enables comparison of muscle and joint reaction-forces throughout gait. This provides the loading scenario implemented in FE. FE modelling demonstrates the effect of loading on the amputated limb via a prosthetic socket by comparing bone mechanical stimulation in amputee and control cases.Abstract
Objectives
Methods
Simultaneous correction of knee varus malalignment with medial open wedge high tibial osteotomy (MOWHTO) combined with anterior cruciate ligament (ACL) surgery aims to address symptomatic unicompartmental osteoarthritis in addition to restore knee stability in order to improve outcomes. The aim of this study is to present at least 5 years results of 32 patients who underwent simultaneous knee realignment osteotomy with ACL surgery. Patients with symptomatic instability due to chronic ACL deficiency or failed previous ACL surgery together with a varus malalignment of ≥6°, previous medial meniscectomy and symptomatic medial compartment pain who were treated with MOWHTO combined with ACL surgery were enrolled. ACL surgery was performed with the anatomical single bundle all-inside technique using TightRope® RT (Arthrex, Naples, FL, USA) and MOWHTO using TomoFix® medial high tibia plate (DePuy Synthes, Raynham, MA, USA) in all cases. Patients were evaluated preoperatively and at 6 months, 12 months and annually postoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Oxford Knee Score (OKS) and Euroqol's Visual Analogue Score (VAS) for pain.Introduction
Methods
Osteoarthritis (OA) is a joint degenerative disease leading to chronic pain and disability, thus resulting in a major socioeconomic health burden. OA, which has long been believed to be a cartilage disease, is now considered a whole-joint disorder affecting various anatomical structures, including subchondral bone. Hyaluronic Acid (HA) is commonly used as intra-articular viscosupplementation therapy for its mechanical features and biological effects. Bisphosphonates (BPs) are antiresorptive agents inhibiting recruitment and maturation of osteoclast precursors and activity of mature osteoclasts in the bone. Pre-clinical evidences in the literature, show that intra-articular BPs could impact on OA progression, slowing down or reversing it. The combination of HA biological and mechanical role and Alendronate (ALD) antiresorptive effect could be an interesting strategy for OA treatment. This study describes the synthesis and characterization of FID-134, a new chemical derivative of HA conjugated with ALD by means of a covalent bond, cleavable in physiological condition. FID-134 was synthesized starting from 500 kDa HA: chemical structure and functionalization degree with ALD were investigated by NMR and ICP-OES. Kinetics of ALD release from FID-134 was determined in TRIS buffer at 37°C and compared to a simple mixture of HA+ALD. 20mg/mL formulations of FID-134 and HA+ALD were investigated for viscoelastic properties, in absence and presence of Ca2+ ions. The cytotoxicity of FID-134 and free ALD were tested on Saos-2 osteoblasts (ATCC HTB-85) and on primary bovine chondrocytes (PBC) at day 1, 3 and 7. The efficacy of FID-134 was assessed in an inflammatory arthritis FID-134 structure was confirmed by NMR and the 20% mol/mol functionalization degree was determined by ICP-OES. Only about 50% of total bound ALD was released from FID-134 within 7 days, resulting slower compared to HA+ALD mixture. In presence of Ca2+ ions, viscoelastic properties of FID-134 dramatically improved, while HA+ALD formulation remained unaffected. The cytotoxicity of ALD was evident at 100 μM on Saos-2 and PBC after 3 days, while no cytotoxicity was observed at 7 days with FID-134. In the cartilage explant model, a strong collagen release was detected in inflammatory conditions after 3 weeks; this tendency was reversed, and collagen release halved when FID-134 was added to the biopsies. The synthesized HA-ALD adduct, FID-134, opens the door for a new approach for OA treatment. The results suggest that FID-134 could be beneficial in cartilage degradation and in restoration of subchondral bone function. Finally, local administration and controlled BP release would likely overcome the drawbacks of ALD oral administration, such as unspecific features and long-term toxic side effects.
Low back pain (LBP), caused by intervertebral disc (IVD) degeneration represents one of the most significant socioeconomic conditions facing Western economies. Novel regenerative therapies, however, have the potential to restore function and relieve pain. We have previously shown that stimulation of adipose-derived stem cells (ASCs) with growth differentiation factor-6 (GDF6) promotes differentiation to nucleus pulposus (NP) cells of the IVD, offering a potential treatment for LBP. The aims of this study were to i) elucidate GDF6 cell surface receptor profile and signalling pathways to better understand mechanism of action; and (ii) develop a microparticle (MP) delivery system for GDF6 stimulation of ASCs. GDF6 receptor expression by ASCs (N=6) was profiled through western blot, immunofluorescence (IF) and flow cytometry. Signal transduction through Smad1/5/9 and non-Smad pathways following GDF6 (100ng/ml) stimulation was assessed using western blotting and confirmed using pathway specific blockers and type II receptor sub-unit knockdown using CRISPR. Release kinetics of GDF6 from MPs was calculated (BCA assay, ELISAs) and ASC differentiation to NP cells was assessed. BMPR profiling revealed high BMPR2 expression on ASCs. GDF6 stimulation of ASCs resulted in significant increases in Smad1/5/9 and Erk phosphorylation, but not p38 signalling. Blocking GDF6 signalling confirmed differentiation to NP cells required Smad phosphorylation, but not Erk. GDF6 release from MPs was controlled over 14days
Experimental simulation is the gold standard wear testing method for total knee replacements (TKR), with reliable replication of physiological kinematic conditions. When combined with a computational model, such a framework is able to offer deeper insight into the biomechanical and wear mechanisms. The current study developed and validated a comprehensive combined experimental and computational framework for pre-clinical biomechanics and wear simulation of TKR. A six-station electro-mechanical knee simulator (SimSol, UK), capable of replicating highly demanding conditions with improved input kinematic following, was used to determine the wear of Sigma fixed bearing curved TKRs (DePuy, UK) under three different activities; standard-walking, deep-squat, and stairs-ascending. The computational model was used to predict the wear under these 3 conditions. The wear calculation was based on a modification of Archard's law which accounted for the effects of contact stress, contact area, sliding distance, and cross-shear on wear. The output wear predictions from the computational model were independently validated against the experimental wear rates. The volumetric wear rates determined experimentally under standard-walking, deep-squat, and stairs-ascending conditions were 5.8±1.4, 3.5±0.8 and 7.1±2.0 [mm3/mc] respectively (mean ± 95% CI, n=6). The corresponding predicted wear rates were 4.5, 3.7, and 5.6 [mm3/mc]. The coefficient of determination for the wear prediction of the framework was 0.94. The wear predictions from the computational model showed good agreement with the experimental wear rates. The model did not fully predict the changes found experimentally, indicating other factors in the experimental simulation not yet incorporated in the framework, such as plastic deformation, may play an additional role experimentally in high demand activities. This also emphasises the importance of the independent experimental validation of computational models. The combined experimental and computational framework offered deeper insight into the contact mechanics and wear from three different standard and highly demanding daily activities. Future work will adopt the developed framework to predict the effects of patients and surgical factors on the mechanics and wear of TKR.
Autologous chondrocyte implantation (ACI) is contra-indicated in a joint rendered unstable by a ruptured anterior cruciate ligament (ACL). We present our experience of ACI repair with ACL reconstruction Patients underwent arthroscopic examination and cartilage harvesting of the knee. A second operation was undertaken approximately six weeks later to repair the ruptured ACL with hamstring graft or Bone patella-Bone (BPB) and to implant the chondrocytes via formal arthrotomy. Three groups were assessed: Group 1: Simultaneous ACL Reconstruction and ACI; Group 2: Previous ACL Reconstruction with subsequent ACI repair; Group 3: Previously proven partial or complete ACL rupture, deemed stable and not treated with reconstruction with ACI procedure subsequently. Patients then underwent a graduated rehabilitation program and were reviewed using three functional measurements: Bentley functional scale, the modified Cincinnati rating system, and pain measured on a visual analogue scale. All patients also underwent formal clinical examination at review.Introduction
Methods
Fusion is a fundamental procedure in spine surgery. Although autogenous grafts have ideal bone graft characteristics, their use may remain limited due to various morbidities. Even though ceramic based synthetic bone grafts are used commonly at present, in order to enhance their efficacy, their combined use with other materials has been investigated. The use of carbon nanotubes (CNTs) together with synthetic bone grafts such as hydroxyapatite (HA) has contributed to positive developments in bone tissue engineering. The aim of the present study was to investigate the effect of CNTs/ HA- tricalcium phosphate (TCP) composite prepared in posterolateral spinal fusion model.Background context
Purpose
open tibia fractures are best treated in an orthopaedic-plastic surgical multidisciplinary setting. Open fractures of the leg represent a severe trauma. It is often stated that combining the skills of Plastic and Orthopaedic surgeons can optimise the results of limb salvage in complex limb injury. The multidisciplinary approach, shared between plastic and orthopaedic surgeons, is likely to provide the optimal treatment of these injuries, although this mutidisciplinary simultaneous treatment is not routinely performed. Given the relatively low incidence of these traumas, a multicentric recruitment of these patients can contribute in providing an adequately numerous cohort of patients to be evaluated through the long process of soft tissue and bone healing following an open tibia fracture. We compared three centres with different protocols for management of these challenging cases.Summary
Introduction
Due to its avascular nature, articular cartilage exhibits a very limited capacity to regenerate and to repair. Although much of the engineered cartilage grafts so far proposed have successfully shown to mimic the morphological and biochemical appearance of hyaline cartilage, they are generally mechanically inferior to the natural tissue1. In this study a new bioreactor device was realized to test innovative scaffolds under physiological stimulation (i.e. perfusion fluid flow and dynamic compression), with the aim to produce a more functional engineered tissue construct for articular applications. The computer-controlled bioreactor system has been properly designed to simultaneously provide static or dynamic compression and/or continuous perfusion to 3D engineered constructs, reproducing the physiological loads to which the articular cartilage is subjected. The specifically designed bioreactor comprises a chamber where the grafts are accommodated, a porous piston connected to a linear stepper motor (Dings, Model 34-2080-4-300), which controls its movement to provide mechanical stimulation and a peristaltic pump (Watson-Marlow, Model 323S), connected by joints and pipes to the culture chamber to ensure a continuous media perfusion. As piston for compression, a sintered stainless steel filter (43% of porosity) was adopted to allow the perfusion of the culture media during physical stimulation. The culture chamber is composed by a hollow cylinder (30 mm × 40,5 mm) and a base realized as a single object. They are made in polycarbonate for its characteristics of transparency and infrangibility and linked to a Nylon cover through four brass tie rods unscrewable from above. The chamber has been designed to accommodate simultaneously different constructs of any size and shape and stimulate them with perfusion and/or dynamic compression. A finites elements program was used to mimic the effects of perfusion and compression regime on the scaffolds cultured within the bioreactor chamber. The bioreactor was properly designed and developed. Particular attention has been paid to the implementation of a simple, compact and economical system. It was then tested by using different polymeric porous scaffolds (PVA, collagen, Gelatin grafts, both porous and not) cultured with mesenchymal cells up to two weeks. The system has been validated in terms of sterility, experimental reproducibility and ease to use. The structural stability of grafts over time has been observed; moreover cells adhesion, proliferation and matrix production under different chemical-physical stimuli conditions is under investigation. We have realized a novel bioreactor system representing an artificial articular niche, where a dynamic compression combined with fluid perfusion allows to functionally and mechanically validate tissue substitutes, besides investigating the response of engineered cartilaginous tissues to physical stimuli mimicking the natural cartilage micro-environment. Such bioreactor may be in fact adopted as a sort of articular simulator for promoting and standardizing the new tissue formation in vitro, preconditioning cell fate through the application of proper artificial stimuli. Moreover, they can be valid tools to investigate physiological processes and novel therapeutic approaches avoiding controversial animal models.
Autologous Chondrocyte Implantation (ACI) is frequently used to treat chondral defects in the knee with a good long-term outcome. This is contraindicatd in meniscal deficient knees. Allogenic Menicsal Transplantation (AMT) has been shown to give good symptomatic relief in meniscus deficient knees. However this is contraindicated in advanced cartilage degeneration. We hypothesized that combination of these two might be a solution for bone-on-bone arthritis in young individuals. We studied a consecutive series of 12 patients who underwent combined ACI and AMT between 1998 and 2005. Pre operative and post operative comparisons of lysholm scores were recorded. Magnetic Resonance Imaging was performed to assess the integration ACI & AMT. Arthroscopy was performed at one year for assessment and obtain biopsy for histological examination.Background
Methods
Glenoid loosening, still a main complication for shoulder arthroplasty, was suggested to be related implant design, surgical aspects, and also bone quality. However, typical studies of fixation do not account for heterogeneity in bone morphology and density which were suggested to affect fixation failure. In this study, a combination of cyclic rocking horse tests on cadaver specimens and microCT-based finite element (microFE) analysis of specimens of a wide range of bone density were used to evaluate the effects of periprosthetic bone quality on the risks of loosening of anatomical keeled or pegged glenoid implants. Six pairs of cadaveric scapulae, scanned with a quantitative computer tomography (QCT) scanner to calculate bone mineral density (BMD), were implanted with either cemented anatomical pegged or keeled glenoid components and tested under constant glenohumeral load while a humeral head component was moved cyclically in the inferior and superior directions. Edge displacements were measured after 1000, 4000 and 23000 test cycles, and tested for statistical differences with regards to changes or implant design. Relationships were established between edge displacements and QCT-based BMD below the implant. Four other specimens were scanned with high-resolution peripheral QCT (82µm) and implanted with the same 2 implants to generate virtual models. These were loaded with constant glenohumeral force, varying glenohumeral conformity and superior or inferior load shifts while internal stresses at the cement-bone and implant-cement interfaces were calculated and related to apparent bone density in the periprosthetic zone.Introduction
Methods