Dislocation after Total Hip Arthroplasty (THA) is a frequent cause of revision and patients with intrinsic risk factors have been identified. The use of dual mobility (DM) cup has shown great efficiency in preventing dislocation, with questions regarding selective or absolute use. The aim of this study was to compare the outcome of single mobility THA (SM-THA) and DM-THA, when used for selected patients. This retrospective continuous cohort study evaluated 490 patients of whom 275 received SM-THA and 215 received DM-THA. There were 304 primary osteoarthritis (62%), 121 femoral neck fractures (24%) and 65 other indications (14%). The surgical approach was anterior (AA) in 79% and posterior (PA) in 21% of cases. In the DM-THA group, 189 patients (87%) presented at least one dislocation risk factor compared to 128 patients (46%) in the SM-THA group. The primary outcome was revision for all causes, with or without implant removal. Secondary outcomes included length of hospital stay. There was no difference in all cause revision at two years follow up with 9 procedures (3.2%) in SM-THA group and 11 in DM-THA group (5.1%) (p=0.3). There were 3 dislocations in SM-THA group (3 AA) and 3 in DM-THA group (2 PA and 1 AA) (p=0.4). The length of stay was significantly longer in DM-THA group with 7 days (2–12) compared to 4 days (1–7) in SM-THA group (p=0.001). SM-THA and DM-THA are two complementary devices in the management of patients requiring primary THA. SM-THA is a safe option for patients without dislocation risk factors, especially when using AA. The identification of such factors is important to select patients requiring DM-THA and provide reproducible outcomes in a University Hospital practice including various levels of surgeon experience.
The gold standard treatment of hip dysplasia is a peri-acetabular osteotomy (PAO). Labral tears are seen in the majority of patients presenting with hip dysplasia and diagnosed using Magnetic Resonance Imaging (MRI). The goal was to (1) evaluate utility/value of MRI in patients undergoing hip arthroscopy at time of PAO, and (2) determine whether MRI findings of labral pathology can predict outcome. A prospective randomized controlled trial was conducted at tertiary institutions, comparing patients with hip dysplasia treated with isolated PAO versus PAO with adjunct hip arthroscopy. This study was a subgroup analysis on 74 patients allocated to PAO and adjunct hip arthroscopy (age 26±8 years; 89.2% females). All patients underwent radiographic and MRI assessment using a 1.5-Tesla with or 3-Tesla MRI without arthrography to detect labral or cartilage pathology. Clinical outcome was assessed using international Hip Outcome Tool-33 (iHOT). 74% of patients (55/74) were pre-operatively diagnosed with a labral tear on MRI. Among these, 41 underwent labral treatment (74%); whilst among those without a labral tear on MRI, 42% underwent labral treatment (8/19). MRI had a high sensitivity (84%), but a low specificity (56%) for labral pathology (p=0.053). There was no difference in pre-operative (31.3±16.0 vs. 37.3±14.9; p=0.123) and post-operative iHOT (77.7±22.2 vs. 75.2±23.5; p=0.676) between patients with and without labral pathology on MRI. Value of MRI in the diagnostic work-up of a patient with hip dysplasia is limited. MRI had a high sensitivity (84%), but low specificity (44%) to identify labral pathology in patients with hip dysplasia. Consequently, standard clinical MRI had little value as a predictor of outcome with no differences in PROM scores between patients with and without a labral tear on MRI. Treatment of labral pathology in patients with hip dysplasia remains controversial. The results of this subgroup analysis of a prospective, multi-centre RCT do not show improved outcome among patients with dysplasia treated with labral repair.
Residual Legg-Calve-Perthes (LCP) deformities represent one of the most challenging disorders in hip reconstructive surgery. We assessed mid-term PRO A longitudinal cohort study was performed on 31 hips with complex LCP deformities undergoing combined SD/PAO. Treatment included femoral head reshaping, trochanteric advancement and relative neck lengthening, management of intra-articular lesions and PAO. Twenty-seven (87.1%) had minimum 5-year follow up. Average age was 19.8 years with 56% female and 44% having previous surgery. At a mean 8.4 years, 85% (23/27) of the hips remain preserved (no conversion to THA). The survivorship estimates at 5 and 10 years were 93% and 85%, respectively. The median and interquartile range for mHHS increased from 64 [55–67] to 92 [70–97] (p<0.001), the WOMAC-pain improved from 60 [45–75] to 86 [75–100] (p= 0.001). An additional 19% (n=5) reported symptoms (mHHS <70) at final follow-up. UCLA activity score increased from a median of 8 [6–10] to 9 [7–10] (p=0.207). Structural correction included average improvements of acetabular inclination 15.3o ± 7.6, LCEA 20.7° ± 10.8, ACEA 23.4° ± 16.3, and trochanteric height 18 mm ± 10 mm (all, p<0.001). Complications occurred in two (7%) patients including one deep and one superficial wound infection. At intermediate follow-up of combined SD/PAO for complex LCP deformities, 85% of hips are preserved. This procedure provides reliable deformity correction, major pain relief, improved function and acceptable complication/failure rates.
This matched cohort study aims to (a) assess differences in spinopelvic characteristics of patients having sustained a dislocation following THA and a control THA group without dislocation; (b) identify spinopelvic characteristics associated with risk of dislocation and; (c) propose an algorithm to define the optimum cup orientation for minimizing dislocation risk. Fifty patients with a history of THA dislocation (29 posterior-, 21 anterior dislocations) were matched for age, gender, body mass index, index diagnosis, and femoral head size with 100 controls. All patients were reviewed and underwent detailed quasi-static radiographic evaluations of the coronal- (offset; center-of-rotation; cup inclination/anteversion) and sagittal- reconstructions (pelvic tilt, pelvic incidence, lumbar lordosis, pelvic-femoral-angle, cup ante-inclination). The spinopelvic balance (PI-LL), combined sagittal index (CSI= Pelvic-femoral-angle + Cup Anteinclination) and Hip-User-Index were determined. sagittal index (CSI= Pelvic-femoral-angle + Cup Anteinclination) and Hip-User-Index were determined. Parameters were compared between the two groups (2-group analysis) and between controls and per direction of dislocation (3-group analysis). There were marginal coronal differences between the groups. Sagittal parameters (lumbar-lordosis, pelvic-tilt, CSI, PI-LL and Hip-User-Index) differed significantly. PI-LL (>10°) and standing pelvic tilt (>18°) were the strongest predictors of dislocation risk (sensistivity:70%/specificity:70%). All hips with a standing CSI<195° dislocated posteriorly and all with CSI>260° dislocated anteriorly. A CSI between 200–245° was associated with significantly reduced risk of dislocation (OR:6; 95%CI:2.5–15.0; p<0.001). In patients with unbalanced and/or rigid lumbar spine, standing CSI of 215–245° was associated with significantly reduced dislocation risk (OR:10; 95%CI:3.2–29.8; p<0.001). PI-LL and standing pelvic-tilt determined from pre-operative, standing, lateral spinopelvic radiograph can be useful screening tools, alerting surgeons of patients at increased dislocation risk. Measurement of the pelvic-femoral angle pre-operatively provides valuable information to determine the optimum, cup orientation associated with reduced dislocation risk by aiming for a standing CSI of 200–245°.
Different techniques have been described to address massive bone loss of the acetabulum in revision hip surgery. aMace has gained popularity as it provides customization aiming to restore hip centre and provide good initial stability in cases of large non-contained defects. It takes into account quality of host bone. Its porous defect filling scaffold provides an excellent surface for osteointegration. Our aim was to assess the short and mid-term outcomes of patients who underwent revision surgery using aMace system. Ethical approval was obtained. A retrospective study included all patients who had aMace between June 2013 and October 2022 allowing for a minimum of 12-months follow-up. Patients’ demographics, indication, bone-loss severity, reconstruction details, re-operation, complications, mortality, pain and function were assessed. 52 cases were performed by 13 surgeons with median 51 months follow-up. Median age was 72.7 years. 86.5% were female. Average BMI was 25.3. Average ASA grade was 3. 65% were classified as Paprosky IIIB and 32% were IIIA. 73% were found to have poor bone quality on CT. Main indication for aMace was massive bone loss/discontinuity secondary to aseptic loosening in 88.5%. 77% underwent single-stage revision. 53.8% had 2 or more previous revisions. 71% underwent stem revision in the same setting. 77% received a dual mobility bearing. Re-operation rate was 5.7% for instability and femoral PPF. LLD was reported in 9.6%. Permanent Sciatic nerve palsy occurred in 3.8% of the cases. 30-days mortality was 1.9%. Statistically significant post-op improvements in pain and mobility were reported (p<0.001). None of the acetabular components have been revised. Our study shows satisfactory surgical outcomes with a relatively low complication rate and significant pain and mobility improvements in the early to mid-term stages. We recommend these costly cases to be done in highly specialist centres adopting MDT approach.
Trabecular metal (TM) augments are a relatively
new option for reconstructing segmental bone loss during acetabular
revision. We studied 34 failed hip replacements in 34 patients that
were revised between October 2003 and March 2010 using a TM acetabular
shell and one or two augments. The mean age of the patients at the
time of surgery was 69.3 years (46 to 86) and the mean follow-up
was 64.5 months (27 to 107). In all, 18 patients had a minor column
defect, 14 had a major column defect, and two were associated with
pelvic discontinuity. The hip centre of rotation was restored in
27 patients (79.4%). The Oxford hip score increased from a mean
of 15.4 points (6 to 25) before revision to a mean of 37.7 (29 to
47) at the final follow-up. There were three aseptic loosenings
of the construct, two of them in the patients with pelvic discontinuity.
One septic loosening also occurred in a patient who had previously
had an infected hip replacement. The augments remained stable in
two of the failed hips. Whenever there was a loose acetabular component
in contact with a stable augment, progressive metal debris shedding
was evident on the serial radiographs. Complications included another
deep infection treated without revision surgery. Good clinical and
radiological results can be expected for bone-deficient acetabula
treated by a TM cup and augment, but for pelvic discontinuities
this might not be a reliable option. Cite this article:
To analyze the evolution of “Tsukayama type IV” infections (unexpected positive intraoperative cultures in hip arthroplasty -THA- exchange because of supposedly mechanical failure) treated with an extended protocol of combined oral antibiotics. Prospective cohort: 14 patients, 66.9+/−10.9 years (40–85), 11 males (78.6%). Eleven suffered isolated cup exchange: 6/14 first cup-exchange, 4/14 second (one with a 1st Slooff impaction-grafting reconstruction and 2 with a 2nd Slooff reconstruction), 1/14 third cup-exchange. Two were operated of isolated stem exchange. One patient received a complete exchange. Cultures identified 10 epidermidis (5 methicillin-resistant -MR-), 4 aureus (3 MR), 1 Propionibacterium, 1 Enterococcus, 1 Escherichia, 1 Streptococcus, 1 Corynebacterium, and 1 Ruminococcus. Patients received 2 oral combined intracellular and biofilm-effective antibiotics for 6 months: ciprofloxacin (8 patients), rifampin (6), amoxicillin-clavulanic (3), levofloxacin (2), clindamycin (3), trimethoprim-sulfamethoxazole (2), fosfomicin (2). Follow-up: 4.5+/−4.3 years (1–14). Healing: absence of clinical, serological and radiographic signs of infection along all followup. Infection reappeared in 1/14 patients (7.1%) with pain, distance limitation and elevated ESR&CRP; patient rejected surgery and was treated with a 2nd cycle of oral antibiotics, disappearing symptoms and serological abnormality along the following 7 years. The other 13 cases maintained normal ESR&CRP along follow-up. At the end of follow-up, 4/14 hips remain asymptomatic and with no limitation of function, 11/14 present no pain, 10/14 walk over 1Km without support, 1/11 uses a cane, 1/14 two crutches, and 2/14 a walker. In conclusión, oral combined antibiotics may be a useful alternative therapy for Tsukayama type IV hip arthroplasty infections.
Dislocation is a serious complication to be avoided in total hip arthroplasty (THA) and its incidence risk increases in revision surgery.
Although there are various pelvic osteotomies for acetabular dysplasia of the hip, shelf operations offer effective and minimally invasive osteotomy. Our study aimed to assess outcomes following modified Spitzy shelf acetabuloplasty. Between November 2000 and December 2016, we retrospectively evaluated 144 consecutive hip procedures in 122 patients a minimum of five years after undergoing modified Spitzy shelf acetabuloplasty for acetabular dysplasia including osteoarthritis (OA). Our follow-up rate was 92%. The mean age at time of surgery was 37 years (13 to 58), with a mean follow-up of 11 years (5 to 21). Advanced OA (Tönnis grade ≥ 2) was present preoperatively in 16 hips (11%). The preoperative lateral centre-edge angle ranged from -28° to 25°. Survival was determined by Kaplan-Meier analysis, using conversions to total hip arthroplasty as the endpoint. Risk factors for joint space narrowing less than 2 mm were analyzed using a Cox proportional hazards model.Aims
Methods
To identify factors influencing clinicians’ decisions to undertake a nonoperative hip fracture management approach among older people, and to determine whether there is global heterogeneity regarding these factors between clinicians from high-income countries (HIC) and low- and middle-income countries (LMIC). A SurveyMonkey questionnaire was electronically distributed to clinicians around the world through the Fragility Fracture Network (FFN)’s Perioperative Special Interest Group and clinicians’ personal networks between 24 May and 25 July 2021. Analyses were performed using Excel and STATA v16.0. Between-group differences were determined using independent-samples Aims
Methods
Aims. The aims of this study were to compare the diagnostic test characteristics
of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI)
alone, and ultrasound combined with MARS-MRI for identifying intra-operative
pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients
undergoing revision surgery. . Methods. This retrospective diagnostic accuracy study involved 39 patients
(40 MoMHRs). The time between imaging modalities was a mean of 14.6
days (0 to 90), with imaging performed at a mean of 5.3 months (0.06
to 12) before revision. The prevalence of intra-operative pseudotumours
was 82.5% (n = 33). Results. Agreement with the intra-operative findings was 82.5% (n = 33)
for ultrasound alone, 87.5% (n = 35) for MARS-MRI alone, and 92.5%
(n = 37) for ultrasound and MARS-MRI combined. The diagnostic characteristics
for ultrasound alone and MARS-MRI alone reached similar sensitivities
(90.9% vs 93.9%) and positive predictive values
(PPVs; 88.2% vs 91.2%), but higher specificities
(57.1% vs 42.9%) and negative predictive values
(NPVs; 66.7% vs 50.0%) were achieved with MARS-MRI.
Ultrasound and MARS-MRI combined produced 100% sensitivity and 100%
NPV, whilst maintaining both specificity (57.1%) and PPV (91.7%). For the identification of a pseudotumour, which was confirmed
at revision surgery, agreement was substantial for ultrasound and
MARS-MRI combined (κ = 0.69), moderate for MARS-MRI alone (κ = 0.54),
and fair for ultrasound alone (κ = 0.36). Discussion. These findings suggest that ultrasound and/or MARS-MRI have a
role when assessing patients with a MoMHR, with the choice dependent
on local financial constraints and the availability of ultrasound
expertise. However in patients with a MoMHR who require revision,
combined imaging was most effective. Take home message:
This study aimed to assess the effect of flexion and external rotation on measurement of femoral offset (FO), greater trochanter to femoral head centre (GT-FHC) distance, and neck shaft angle (NSA). Three-dimensional femoral shapes (n=100) were generated by statistical shape modelling from 47 CT-segmented right femora.
The study sought to determine the results of labral restoration among patients over age 60 compared to a cohort of younger adults. 21 consecutive patients over age 60 undergoing labral repair with minimum one-year follow-up were compared to a contemporaneous group of 21 patients age 18–55 matched for gender, degree of chondral damage, and associated FAI or dysplasia. Follow-up averaged 18.9 months (12 to 24 months). The study group averaged 63.2 years (61 to 71); with 20 FAI and one dysplasia. 19 had acetabular articular damage (2 grade IV, 11 grade III, 5 grade II, 1 grade I) and 6 had femoral changes (1 grade IV, 5 grade 3). The control group averaged 35.8 years (20 to 54). Average improvement among the study group was 28.1 points modified Harris Hip Score (mHHS) and 37.5 points iHOT; and among the control group, 21.2 points mHHS and 37.1 points iHOT. There was no statistically significant difference between the two groups in the amount of improvement, with statistically and clinically significant improvement noted in both. Two study group patients underwent total hip arthroplasty (THA) at average 10 months with one control group THA at 11 months. All three converted to THA had combined grade IV acetabular and grade III femoral damage. There were no repeat arthroscopies and no complications in either group. We conclude that patients over age 60 can benefit from arthroscopic labral repair with improved outcomes, modest rates of conversion to THA, and small risk of complication. Results are comparable to younger adults.
Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies. Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.Aims
Methods
The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.Aims
Methods
The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed.Aims
Methods
Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.Aims
Methods
Unknown femur orientation during X-ray imaging may cause inaccurate radiographic measurements. The aim of this study was to assess the effect of 3D femur orientation during radiographic imaging on the measurement of greater trochanter to femoral head centre (GT-FHC) distance. Three-dimensional femoral shapes (n=100) of unknown gender were generated using a statistical shape model based on a training data of 47 CT segmented femora. Rotations in the range of 0° internal to 50° external and 50° of flexion to 0° of extension (at 10 degree increments) were applied to each femur. A ray tracing algorithm was then used to create 2D images representing radiographs of the femora in known 3D orientations. The GT-FHC distance was then measured automatically by identifying the femoral head, shaft axis and tip of greater trochanter. Uniaxial rotations had little impact on the measurement with mean absolute error of 0.6 mm and 3.1 mm for 50° for pure external rotation and 50° pure flexion, respectively.
This study aimed to evaluate sagittal spinopelvic alignment (SSPA) in the early stage of rapidly destructive coxopathy (RDC) compared with hip osteoarthritis (HOA), and to identify risk factors of SSPA for destruction of the femoral head within 12 months after the disease onset. This study enrolled 34 RDC patients with joint space narrowing > 2 mm within 12 months after the onset of hip pain and 25 HOA patients showing femoral head destruction. Sharp angle was measured for acetabular coverage evaluation. Femoral head collapse ratio was calculated for assessment of the extent of femoral head collapse by RDC. The following parameters of SSPA were evaluated using the whole spinopelvic radiograph: pelvic tilt (PT), sacral slope (SS), pelvic incidence (PI), sagittal vertical axis (SVA), thoracic kyphosis angle (TK), lumbar lordosis angle (LL), and PI-LL.Aims
Methods
Some patients presenting with hip pain and instability and underlying acetabular dysplasia (AD) do not experience resolution of symptoms after surgical management. Hip-spine syndrome is a possible underlying cause. We hypothesized that there is a higher frequency of radiological spine anomalies in patients with AD. We also assessed the relationship between radiological severity of AD and frequency of spine anomalies. In a retrospective analysis of registry data, 122 hips in 122 patients who presented with hip pain and and a final diagnosis of AD were studied. Two observers analyzed hip and spine variables using standard radiographs to assess AD. The frequency of lumbosacral transitional vertebra (LSTV), along with associated Castellvi grade, pars interarticularis defect, and spinal morphological measurements were recorded and correlated with radiological severity of AD.Aims
Methods