Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 9 - 9
1 Jul 2014
O'Neill B Fox C Molloy A Moore D
Full Access

The purpose of this study was to review the outcomes and complications of all circular external fixators (frames) used for the management of acute lower limb trauma in our institution over a twenty year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 68 fractures in 63 patients. There were 11 femoral fractures and 57 tibial fractures. All fractures were classified using the AO Classification system, and most fractures were Type C fractures. We used an Ilizarov frame in 53 patients and a Taylor Spatial Frame in 15 patients. The mean time in frame was 365 days for a femoral fracture and 230 days for a tibial fracture. There were five tibial non-unions giving an overall union rate of 93%. Factors associated with non-union included high energy trauma and cigarette smoking. The vast majority of lower limb fractures can be treated using ‘conventional’ methods. Complex fractures which are not amenable to open reduction and internal fixation or cast immobilisation can be treated in a frame with excellent results. The paucity of published reports regarding the use of frames for complex trauma reflects the under-utilisation of the technique


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 14 - 14
1 Jul 2014
O'Neill B Breathnach O Moore D
Full Access

The purpose of this study was to review the outcomes and complications of all circular external fixators (frames) used for the management of sterile and infected fracture non-unions in the lower limb in our institution over a twenty year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 76 non-unions in 76 patients. There were 22 femoral non-unions and 54 tibial non-unions. Five femoral non-unions and 12 tibial non-unions were confirmed infected. The mean time in frame was 281 days for a sterile non-union and 457 days for an infected non-union. There was a union rate of 87% for sterile non-unions and 71% of infected non-unions at cessation of treatment. Factors associated with persistent non-union included cigarette smoking, soft tissue complications, and excessive pin-site toilet by the patient. Lower-limb fracture non-unions can be extremely difficult to treat. The patients included in our study had previously undergone more traditional treatments in an attempt to establish union. The results presented demonstrate that circular frames are an excellent treatment modality in non-unions resistant to other forms of treatment. We would recommend this as a first line treatment for patients at higher risk of developing fracture non-union


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1427 - 1432
1 Oct 2012
Chassanidis CG Malizos KN Varitimidis S Samara S Koromila T Kollia P Dailiana Z

Periosteum is important for bone homoeostasis through the release of bone morphogenetic proteins (BMPs) and their effect on osteoprogenitor cells. Smoking has an adverse effect on fracture healing and bone regeneration. The aim of this study was to evaluate the effect of smoking on the expression of the BMPs of human periosteum. Real-time polymerase chain reaction was performed for BMP-2,-4,-6,-7 gene expression in periosteal samples obtained from 45 fractured bones (19 smokers, 26 non-smokers) and 60 non-fractured bones (21 smokers, 39 non-smokers). A hierarchical model of BMP gene expression (BMP-2 > BMP-6 > BMP-4 > BMP-7) was demonstrated in all samples. When smokers and non-smokers were compared, a remarkable reduction in the gene expression of BMP-2, -4 and -6 was noticed in smokers. The comparison of fracture and non-fracture groups demonstrated a higher gene expression of BMP-2, -4 and -7 in the non-fracture samples. Within the subgroups (fracture and non-fracture), BMP gene expression in smokers was either lower but without statistical significance in the majority of BMPs, or similar to that in non-smokers with regard to BMP-4 in fracture and BMP-7 in non-fracture samples. In smokers, BMP gene expression of human periosteum was reduced, demonstrating the effect of smoking at the molecular level by reduction of mRNA transcription of periosteal BMPs. Among the BMPs studied, BMP-2 gene expression was significantly higher, highlighting its role in bone homoeostasis.