Aims. There are concerns regarding initial stability and early periprosthetic fractures in
Introduction. Failed operated intertrochanteric fractures (with screw cutout, joint penetration, varus collapse, nonunion, or femoral head avascular necrosis) pose treatment dilemmas. The ideal approach is re-osteosynthesis with autologous bone grafting. When the femoral head is unsalvageable, conversion to a prosthetic hip replacement is necessary. Materials/Methods. Thirty-seven patients with failed dynamic hip screw fixation (and unsalvageable femoral heads) were treated with
We studied the pattern of . 99m. Tc-methylene diphosphonate uptake around uncemented femoral components in 44 asymptomatic hip arthroplasties, performing isotope scans at intervals from 4 to 48 months after operation. We used phase-III images obtained with a high-resolution gamma camera and measured the activity in various zones using a specially designed computer program. The components studied at 4, 6, 9 and 12 months were coated with hydroxyapatite (HA) and those studied at 18, 24, 36 and 48 months were not coated. We found a statistically significant fall in activity between four and six months around HA-coated prostheses in all five femoral periprosthetic zones. After six months activity was relatively uniform, but remained higher than that in normal femoral bone at 48 months in non-coated prostheses. We discuss the application of these patterns in the evaluation of painful
We have analysed the clinical results of a
We present the case of a 65-year-old man who developed a malignant fibrous histiocytoma at the lesser trochanter five months after a
Introduction. Iatrogenic proximal femur hoop-stress fracture is a recognised complication of
Background:. Historically, performing a successful hip joint replacement in patients aged fewer than 30 years has been an orthopedic challenge. The newer generation of prostheses and surgical techniques has the potential to increase the longevity of implants. The purpose of this study was to evaluate the outcomes of
Introduction: It is not uncommon situation, in a hip fracture patient treated with dynamic hip screw(DHS) system, that the hip arthroplasty should be done after removal of DHS. However multiple screw holes and postplating osteopenia under the barrel plate will be created in the proximal femur resulting adverse mechanical effects. Purpose: The authors analysed the micromotion of femoral stem and the stress concentration of proximal femur in hip replacement performed after removal of DHS using finite element analysis. Methods: For simulation of femoral cortical defects after removal of 4-holed DHS system, four Φ4.5 mm cortical screw holes on medial and lateral cortices of the femur and one Φ12mm lag screw. One 20mmx90mm weakened cortical bone area on lateral cortex was made for simulation of the postplating osteopenia created under the barrel plate. After meshing with eight node linear hexahedron, nonlinear contact analysis was done using ABAQUS 5.8 package system. For the postplating osteopenia we decreased the bony strength of cortical bone up to 20%. Results: In one leg stance, the maximal micromotions at metal to bone interface were around 150&
#13211; (142.3-160.6&
#13211;) even in the osteoporotic femur. However, in stair climbing, it increased over 150&
#13211; (170.1-191.1&
#13211;) even in the non-osteoporotic intact femur. The maximal micromotions were 170.1&
#13211; in intact non-osteoporotic femur and 191.1&
#13211; in osteoporotic DHS removed femur in a stair climbing. The pattern of stress distribution on the surface of the femur was changed showing distal transfer of the point with maximal stress from the proximal medial area to the stem tip area. The maximal stress increased up to 89% at the lag screw hole. Conclusion: This study suggests that the femoral stem for primary
Undersizing of an uncemented femoral stem is a post-operative description of a radiograph with unclear clinical importance. It may not always translate into a suboptimal clinical outcome. To describe a novel classification system of undersizing in a fully hydroxyapatite coated femoral implant, assess if it could be reliably reported between observers, and describe a simple way to assess the degree of undersizing on an AP radiograph.Introduction
Aim
Cementless femoral stems must be correctly sized and well-seated to obtain satisfactory biological fixation. The change in sound that occurs during impaction of the femoral broach is said to indicate good fit, but this has not been widely studied. We set out to find whether the presence or absence of these sound changes could predict correct sizing. We recorded the sound generated during femoral broaching for 105 cementless total hip arthroplasties using the Corail stem. Four cases were excluded, leaving 101 recordings for analysis. There were 36 male patients and 65 female patients, with a mean age of 69.9 years (Aims
Patients and Methods
There were 78 Crowe I &
II, and 18 Crowe III &
IV hips. The more dysplastic hips required the versatility of the SROM stems to avoid excessive lengthening or femoral osteotomy. These cases also had significantly more inferior reconstruction of the hip centre, and medialisation of the hip centre. Complications occurred in 8/106 (8%) of cases, the mean time to occurrence being 25 months. The majority were dislocations 7 (7%). There were no sciatic nerve palsies. Revision was required for 5 cups and 1 stem. Clinical evaluation showed all patients were living at home and 85% had no activity restrictions. Mean Harris Hip Score was 92/100. None or mild thigh pain only was reported in 90% of cases. In 98% of cases patients were satisfied with their outcome. Radiographic evaluation showed stem ingrowth occurred in all cases. Minor osteolysis was apparent in 6% of cases. Spot welds were identified in 76% of cases. One case demonstrated pedestal formation.
We examined a group of 26 patients (28 hip joints) with postdysplastic osteoarthritis who were operated in 1995 and 1996. The Zweymüller Bicon prosthesis was used in all cases. Only patients with dysplasia Type B and C according to Eftekhar were included. By the method of Ranawat and Pagnana, the true acetabular region and the approximate femoral head centre were determined on preoperative and postoperative radiographs. The patients were controlled in 1999 with HHS. Antero-posterior radiographs of the pelvis and lateral radiographs of the acetabulum according to Zweymüller were made in all hips. In most of the operated hip joints the true center of the rotation differed from the ideal centre, with the maximal difference being 18 mm cranially. Cranial placement of the cup occurred more frequently in Type C. No patient was reoperated, and as determined by radiographs, there were no indications of loosening in the acetabular and femoral components. The Zweymüller Bicon total hip joint endoprosthesis is suitable in most cases of postdysplastic osteoarhritis of the hip. No special or individual implant was necessary in 1995 and 1996. Good primary stability and a good result was achieved in all cases. We consider this type of hip implant as especially useful in CDH osteoarthritis.
Since 1964, 3573 uncemented Ring total hip replacements of all types have been performed; 194 (5.4%) have required revision for infection, loosening or breakage. Of these, 102 were available for review; 81 had satisfactory results five years after operation. These results are better than many of those reported after revision of cemented hip replacements. It is suggested that the absence of cement makes revision easier because bone erosion rarely occurs.
Conversion of immovable hip to a total hip arthroplasty provides a solution, improving function, reducing back and knee pain, and slowing degeneration of neighboring joints associated with hip dysfunction while the mobilization by total hip arthroplasty is rather uncommon and challenging surgery. Since 1998 we have performed 28 uncemented total hip arthroplasties for arthrodesed or ankylotic Hip. Among them 25 hips in 24 patients (four males and 20 females) with minimum of six months follow-up were evaluated. Thirteen hips were arthrodesed and twelve hips were ankylotic. One patient had arthrodesed hip in one side and ankylotic one in the other side. The mean age at the surgery was 63 (42 to 80). Two patients were Jehovah's witnesses. All 13 arthrodeses had been performed at other hospitals due to developmental dysplasia (11 hips), tuberculous coxitis (one hip), and infection after osteotomy (one hip). The underlying disease for the ankylosis was tuberculous coxitis for one hip and dysplastic osteoarthritis for 12 hips. Spongiosa Metal Cup (GHE, ESKA Orthodynamics AG, Lübeck, Germany) was used for 21 hips (screw fixation was added for two hips), Alloclassic Cup (Zimmer GmbH, Winterthur, Switherland) for one hip, Bicon Plus Cup (Smith & Nephew AG, Rotkreuz, Switherland) for one hip, and Müller's Reinforcement Ring (Zimmer GmbH, Winterthur, Switherland) for two hips. The bearing couple was ceramic on ceramic (Biolox forte, Ceramtec AG, Prochingen, Germany) for 14 hips, ceramic on polyethylene for eight hips, and metal on metal for three hips. Spongiosa Metal Stem (GHE, ESKA Orthodynamics AG, Lübeck, Germany) was used for 15 hips, SL Plus Stems (Smith & Nephew AG, Rotkreuz, Switherland) for nine hips, and Alloclassic Stem (Zimmer GmbH, Winterthur, Switherland) for one hip. All surgeries were carried out through an anterolateral approach. Twelve hips required the adductor tenotomy against the stiffness. The average follow-up period was 3.7 (0.5 to 10.6) years.Introduction
Materials and methods
We found the ABG cementless hip has excessive acetabular wear and premature failure due to osteolysis. In 60 patients implanted at mean age 56 years, 66 hips (mean follow up 48 months), 7 were revised and 7 have severe acetabular osteolysis. In some this is entirely asymptomatic. There was significant association with osteolysis, length of follow up and wear but no correlation between wear and acetabular component position, age, liner thickness, and use of ceramic or CoCr heads. We recommend regular lifelong radiological review of these hips and suspension of use of this prosthesis until a wider review is undertaken.
Delayed sciatic nerve palsy is uncommon after primary hip replacement. Two kinds of sciatic palsy have been reported with regard to the time of onset: early palsy related to wound haematoma or lumbosacral nerve elongation which occurs between surgery and 18 days, is more frequent than delayed palsy, occurring between 10 and 32 months, which is usually caused by cement extrusion or heat produced by cement polymerisation. We present two cases of delayed, transient sciatic nerve palsy arising at three weeks and four months after primary cementless arthroplasty, respectively, without haematoma and with a normal lumbar spine. These palsies were possibly caused by excessive tension from minor limb lengthening of 2 cm to 4 cm required to achieve leg-length equality. As the initial symptoms were limited to calf pain and mild numbness in the foot, surgeons should be aware of this mode of onset, particularly when it is delayed after hip replacement. Both patients recovered fully by 12 months after surgery so we did not undertake surgical exploration of the nerve in either patient.
We have studied the role of computerised axial tomography in the assessment of the acetabulum before an uncemented Mittelmeier arthroplasty was performed in 20 patients. In the absence of gross anatomical abnormality, computerised tomography did not provide additional information, but in eight patients it was useful in determining adequacy of acetabular depth, anterior acetabular cover, and thickness of the anterior and posterior walls. In these patients, the CT scans provided information which was not available from plain radiographs and greatly assisted in pre-operative planning.