Abstract
Introduction
Failed operated intertrochanteric fractures (with screw cutout, joint penetration, varus collapse, nonunion, or femoral head avascular necrosis) pose treatment dilemmas. The ideal approach is re-osteosynthesis with autologous bone grafting. When the femoral head is unsalvageable, conversion to a prosthetic hip replacement is necessary.
Materials/Methods
Thirty-seven patients with failed dynamic hip screw fixation (and unsalvageable femoral heads) were treated with cementless hip arthroplasty (13 underwent Bipolar Arthroplasty, 24 had Total Hip Arthroplasty) over a 5-year period (Dec 2005 to Nov 2010). Seven needed a modified trochanteric split, and the rest were managed by standard anterolateral approach. Abductor mechanism was reconstructed using strong nonabsorbable sutures (ethibond 5) or stainless steel wires. The calcar was partially reconstructed using remnant femoral head and cerclage wiring in a few cases.
Results
Clinico-radiological assessment was done at three, six, 12 months and yearly thereafter over an average 36 months (range, three to 60 months). Stem loosening, lysis, subsidence and trochanteric union were studied. At last follow-up, one patient had died, and there were two instances each of stem subsidence and trochanteric nonunion. Clinical results using Harris hip scores were good or excellent.
Conclusion
Management of nonsalvageable femoral heads after failed intertrochanteric fracture fixation is possible with cementless hip arthroplasty. Successful outcomes depend on functional abductor reconstruction, fracture and femoral shaft penetration prevention. Autograft, allograft or head/neck replacement components are necessary sometimes.